| 1 | M&L for brick work with fly ash bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 including demolition of old brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles complete all as specified and directed. |
| 2 | M & L for rendering/plaster by using readymix mixture of thickness 12 mm to 15 mm on newly prepared surface and plastering the wall surface with white cement based polymer modified self curing mortar, all complete as per the direction of Engineer-in-Charge. |
| 3 | M & L for repair to plaster by using readymix mixture of thickness 12 mm to 15 mm and plastering the wall surface with white cement based polymer modified self curing mortar, including taking down cement or cement lime plaster, raking out joints and disposal of rubbish, all complete as per the direction of Engineer-in-Charge. |
| 4 | Complete removal of existing treatment on wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean,free from dust, loose paint etc by skilled labour complete all as specified and directed. |
| 5 | M & L for preparation of newly plastered surfaces of wall and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over and including priming coat complete, as per manufacturer's specification complete all as specified & directed. |
| 6 | M & L for preparation of old plastered surfaces of wall and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over and including priming coat complete, as per manufacturer's specification complete all as specified & directed. |
| 7 | M & L for preparation of new wall surface and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 8 | M & L for preparation of old wall surface and applying one coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 9 | Dismantling timber scantling 40 sq cm and over in framed work in any position. |
| 10 | S & F of second class hard wood timber scantling clean sawn framed and fixed in any position and direction complete all as specified and directed. |
| 11 | S & F of rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W complete all as specified and as directed. |
| 12 | S & F in repair for 0.50 mm thick pre-painted galvalume aluminium zinc alloy coated steel (550 Mpa) corrugated sheet of any colour, double ribbed trapezoidal profile in desired length etc, as in roof covering/cladding to wall, with joints overlapped and fastened with fasteners using hot dipped zinc coated self drilling hexagonal washer head fasteners complete all as specified and directed. |
| 13 | S & F in repair for 0.50 mm thick pre-painted galvalume aluminium zinc alloy coated steel (550 Mpa) plain sheet of any colour, double ribbed trapezoidal profile in desired length etc, as in roof covering/cladding to wall, with joints overlapped and fastened with fasteners using hot dipped zinc coated self drilling hexagonal washer head fasteners complete all as specified and directed. |
| 14 | S & F in repair suspended false ceiling with \\"E\\" grid suspended ceiling grid system of grid size 600 x 600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24 x 0.3mm using 4mm thick high pressure steam cured classic variant E-Board, designer pattern to be placed in the grid suspended by 2mm dia GI wire at distance n. exc 1.2m center to center with butterfly clips complete all as specified and directed. |
| 15 | Taking down chowkhat frame with shutter (without taking out shutter from the frame) n exc 1.50 Sqm and removing from sites complete all as specified and directed. |
| 16 | Taking down chowkhat frame with shutter (without taking out shutter from the frame) exc 1.50 Sqm but n. exc 4 sqm each and removing from site complete all as specified and directed. |
| 17 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 mm2 and resistance to spread of flame of Class A category with property of being mite/borer proof,water/ moisture proof and fire retardant 152 SECTION 8 and including fixing in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge, complete all as specified and directed.Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 18 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 mm2 and resistance to spread of flame of Class A category with property of being mite/borer proof,water/ moisture proof and fire retardant 152 SECTION 8 and including fixing in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge, complete all as specified and directed.Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 19 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and including supplying and fixing with stainless steel butt hinges of 100mm size with necessary full body threaded star headed counter sunk S.S screws, and 4 no. stainless steel butt hinges all as per direction of Engineer-In- Charge. |
| 20 | Supply and Fixed Providing 30mm thick Factory Made Wire Mesh Solid Wpc Prelam Door Shutter with lamination consisting of Density 650 Kg /Cum Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh (G-304) 0.36mm minimum dia of wire and average width of aperture 1.40mm shall be fixed with 15x15 mm square tube inside rails with screwing 8x28mm heat metal zinc coated screws and XPM aluminium Mesh for additional strength and safety purpose. (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity including supplying and fixing to frame with 3 nos. M.S powder coated butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws and 2 mm thick edge moulding tape or 90 degree edge bend finish etc. Complete as per direction of Engineer-in -charge, manufacturer's specification & drawings. |
| 21 | S & F Stainless Steel Bow handle matte finish fabricated type 150mm long as directed. |
| 22 | S & F 200mm long Stainless steel matte finish ,barrel tower bolts of extruded section complete all as specified and directed. |
| 23 | S & F 250 mm Stainless steel ,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 24 | S & F 300 mm long MS ordinary pattern door spring \\"plate type\\" including roller and roller plate complete all specified and directed. |
| 25 | S & F two (double) legged floor door stopper of aluminum body & tongues with hard drawer steel spring fixed in floor of 140mm complete all as specified and directed. |
| 26 | M & L for premium quality joint free non skid ceramic tiles, coloured, any shade superior quality, 7 to 8mm thick, (square/ rectangular), area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors / skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 and including dismantling of existing tiling including cement mortar bedding (including backing), removing rubbish off the premises complete all as specified and directed. |
| 27 | M & L for joint free glazed coloured GLOSSY tiles, superior quality of size 300 x 450 x 7mm thick/300 x 600 x 7 to 8mm thick, in vertical surfaces etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 and including dismantling of existing tiling including cement mortar bedding (including backing), removing rubbish off the premises complete all as specified and directed. |
| 28 | M & L for machine cut kota stone slab as in flooring 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing with & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed |
| 29 | M & L for machine cut kota stone 20 to 25 mm thick as in steps, risers, skirting, dado etc, bedded and jointed with grey cement slurry and pointed in white cement with admixture of pigment to match the shade of the stone including grinding, rubbing and polishing with & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix stone complete all as specified |
| 30 | S & F in repair Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame 5mm thick PVC sheet fillet of width 35mm for wall fixed 35cm centre to centre on both side horizontal and vertical to make PVC Frame as per specifications and drawing. |
| 31 | M & L preparation of old wood or wood based surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 32 | M&L preparation of new steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 33 | M&L preparation of old steel surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 34 | M & L of preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint all as specified and directed. |
| 35 | S & F in repair 25mm dia fancy type drapery curtain rod made of stainless steel including knobs (Latto) and side brackets complete all as specified and directed. |
| 36 | S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 37 | S & F Anodised aluminium powder coating of any colour (Thickness or powder coating not less than 50 micron) door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, 150mm long (02) suitable handle in each door, hinges, powder coated aluminum snap beading screws etc. complete all as specified |
| 38 | S & F 5mm thickness sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane all as specified and directed |
| 39 | S & F in repair 0.36 mm dia stainless steel grade 304 wire cloth with average width of aperature 1.40 mm and fixed with stainless steel wire staples or moulded beading complete all as specified and directed. |
| 40 | M & L for 50mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels n exc 3 mtr long, including demolition of cement concrete (unreinforced) in ground floor and paving n exc 15cm thickness and below or above ground level complete all as specified and directed. |
| 41 | Demolition of PCC (un-reinforced) in ground floors and pavings not exc. 15 cm thickness below or above ground levels complete all as specified and directed. |
| 42 | M & L hard core of broken stone gauage not exc 63 mm deposited spread and levelled n.exc 15 cm thick watered and rolled /rammed to a true surface all as specified. |
| 43 | M & L cement concrete 75 mm thick 1:3:6 type C-2 using 40 mm graded stone aggregate complete all as specified. |
| 44 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 45 | M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs, coping, benching etc including weathering slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 46 | Taking down carefully copper/aluminium point wiring(light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose,fan regulators, sketch light fittings, and making good the disturbed surface of walls and floors etc as directed. |
| 47 | Taking down carefully main switches DB's/ MCB DB's and making good the disturbed surfaces of walls as directed. |
| 48 | Taking down carefully copper/aluminium sub main wiring/ service connection including teak wood batten/ conduit and making good the disturbed surface of walls as directed. |
| 49 | M&L, Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:-(NOTE: Switch and socket to be measured and paid for separately):- (a) One light/fan point controlled by one switch |
| 50 | (b) One socket outlet point 5 Amp on an independent board |
| 51 | (c) Same as item no 51(b) but on the same board |
| 52 | (e) For one light point controlled by two 2-way switches, with cable 1.5 sqmm |
| 53 | All as item no 51(b) herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15/20 Amp socket out let point on an independent board. |
| 54 | S & F switch piano flush button single pole one way 5 Amp 240 volt complete as directed. |
| 55 | Ditto as item 6 but using 15 Amps complete all as specified. |
| 56 | S&F switch piano flush button single pole two way 5 Amp 240 volt complete as directed. |
| 57 | S & F socket outlet flush type multipurpose 2 in 1 , 3 pin 5 and 15 Amp, 230 volts complete as directed. |
| 58 | S & F socket outlet flush type 5 pin 5 Amps 240 volts complete as directed |
| 59 | S & F ceiling rose surface bakelight two to three terminal complete as directed |
| 60 | S&F fan regulator electronic, step up socket type, 230 volt and conection complete all as directed |
| 61 | M & L for wall mounting study lamp with Pendant Ceiling Rose Lights B22 Hanging lamp Holder kit for Home Decor,Indoor Outdoor Living Room,Home with complimentary E-Bookwith 3/5 w LED Bulb . |
| 62 | S&F LED surface mounted batten light fitting 16W, powder coated die cast/ extruded aluminium or CRCA sheet phosphated and powder coated body construction confirming to IS:10322 (part-I) / IEC 60598-1 with Replaceable high efficiency electronic driver (diver efficiency >85%,) System lumen efficiency >120 lm/Watt suitable for AC 140-270 Volt, 50 Hz, operating temp range -15 deg to 40 deg. The luminarie shall be provided with internal surge protection of 2.5 KV with Short & Open circuit protection, CRI >80, Flicker <5%, the LED shall be have minimum rated life 50000 burning hours with 70% Lumen maintained till life ends, the CCT shall be 5700°K /6000°K/6500°K (ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption shall not exeed rated wattage the luminarie shall confirm to relevant BIS standard and bear a valid BIS trade mark certificate (TC). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing the item inclued internal wiring with suitable size FRLS, PVC insulated copper conductor cable all connection earthing, fixing accessories and is complete in all respect with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all tests required for LED fixtures as BIS shall be submitted. |
| 63 | S&F in repair LED Building security light 24/25 Watt with high power LED source (>110lumen/watt) PDC housing, IP65 and IK 07 with 4 KV inbuilt surge protection potted driver including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories such as bracket of GI pipe light grade 40 mm dia 0.60 mtr long bend to shape as per suitable size along with all accessories, fixed on wall including bolts & nuts. |
| 64 | Supply and Fixing wall/surface mounting luminaires 2x2 feet mm, 35/36 watt, 220 V AC recessed type 6500k , min burning hours 25000 ,CRI 80 with high efficiency PMMA diffuser soft glare free light complete with driver ,holder & LED lamp suitable for roof ceilling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified MAKES shall be group A cat as per latest approvedmake given by HQ CECC |
| 65 | M&L for Four runs of 6 Sq mm as current carrying conductor and one run of 06 Sq mm as earth conductor. Note: - Four runs of 6 sqmm cable and one run of 6 sqmm cable of earth continuity conductor and one run of PVC conduit shall be measured as one unit length. Please Enable Macros to View BoQ information |
| 66 | M&L for Four runs of 6 Sq mm as current carrying conductor and one run of 06 Sq mm as earth conductor. Note: - Four runs of 6 sqmm cable and one run of 6 sqmm cable of earth continuity conductor and one run of PVC conduit shall be measured as one unit length. Please Enable Macros to View BoQ information |