| 1 | WOOD WORK Factory manufactured solid flush door fixed inposition iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position(Code : IS 2202-1(1999). ((a)) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-((iv)) 35mm thick |
| 2 | Deodar wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles bolts hasp with staple but including the labour for fixing them ((a)) 30mm thick |
| 3 | Deodar wood doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position ((a)) Panelled, glazed or glazed and panelled.((iii)) 30mm thick |
| 4 | (i)) Wire gauze deodar wood door shutter without springs housed in chowkats (Single Leaf)(i) 35 mm thick |
| 5 | (i)) Deodar wood cup board chowkats including iron hold facts, iron hinge, corner, straps, wooden knobs or handles fixed in position (Size 45 x 60mm) |
| 6 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete ((c)) I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 7 | MAINTENANCE OF BUILDINGS AND FURNITURE Renewing glass panes with putty and nails wherever necessary ((b)) Glass panes weighing 10.75 Kg/sqm |
| 8 | CLEARING OF GLASS PANES BOTH SIDES |
| 9 | WHITE WASHING, DISTEMPERING, PAINTING & POLISHING Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 10 | Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade |
| 11 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 12 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 13 | Painting one coat with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint. |
| 14 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 15 | DISMANTLING Scraping ((a)) White wash and colour wash |
| 16 | Cement plaster |
| 17 | Dismantling concrete Reinforced cement concrete |
| 18 | Stripping and stacking slate or tiles of a roof. |
| 19 | PLASTERING & POINTING 12.5 mm thick cement plaster 1:4 |
| 20 | BRICK WORK (i)) First class burnt brick work laid in cement sand mortar 1:3 in first storey upto 4 metres above plinth level. |
| 21 | STEEL AND IRON WORKSupplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 22 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 23 | FLOORING & DADOS Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.(a) Size 600x600 mm |
| 24 | 20mm thick grey polished skirting or dado consisting of bottom layer of 16mm thick cement sand plaster 1.3 and finished 3mm thick topping of neat cement rubbed and polished including rounding of junction with floors. |
| 25 | HOISTING, ROOFING AND WATER PROOFINGProviding and Fixing ceiling at height upto 4 mtr consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge. |
| 26 | COMMON SCHEDULE OF RATES (RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copperconductor single core FR cable(ISI marked) overall 1.5sq.PVC insulated copper conductor single-core FR cable (ISI marked), 1 sq. mm, 1100V grade, laid in heavy-gauge PVC conduit pipe of 20mm/25mm dia (ISI marked) recessed in walls, complete with powder-coated/anodized concealed metal boxes (1.6mm thick with brass lugs) suitable for required modular accessories including step-type electronic fan regulator (2-module, 100W), bell push, 6A 2/3-pin universal shuttered socket, 16/20A combined/universal shuttered socket, 6/10A switches, 16/20A switches with indicator, frame plates, PVC connectors (for fan box and call bell), steel hooks, 1.6mm thick hexagonal sheet metal fan box, circular junction boxes (4-way PVC 1½” deep for walls and CI 3” deep for ceilings), bonding to earth with PVC insulated copper conductor single-core FR cable (ISI marked) 1 sq. mm, 1100V grade for 6A wall socket and plug control points, including all petty materials, cutting and filling of chases, and finishing the surface complete.((i) a) Wiring fan point (Without fan box) |
| 27 | ((ii)) Wiring light point |
| 28 | PROVIDING & FIXING OF 15 WATT (ORIENT/HAVELLS) IN FALSE CEILING AS PER DEPARTMENT DESIGN AND SPECIFICATION |
| 29 | CONCRETE Cement concrete 1:2:4 mixing by manual means |
| 30 | HORTICULTURE Supply and installation of garden bench Chair type garden bench with L-shaped sides made of reinforced concrete (M-30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation |
| 31 | SANITARY INSTALLATIONS Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (B) Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete |
| 32 | (29) 110mm o/d SWR UPVC pipe lines laid complete |
| 33 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.((i)) Triple Layer Tanks Please Enable Macros to View BoQ information |