| 1 | Complete removal of existing water proofing treatment from top of roof and canopies/ chajjas of buildings including removing the debris outside of MD land and earthing strip, electric cable. (Refixing earthing strip and cable at the same place after execution of water proofing treatment) complete all as specified and directed. |
| 2 | M&L for 15 mm thick screed bed in CM (1:4 ) on green suface of concrete surface |
| 3 | M&L for 25 mm thick (average thickneness) PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in roof padding as directed by Engr-in-Charge. |
| 4 | M & L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed. |
| 5 | M&L for applying bitumin primer @ 0.30 ltr/Sqm conforming to IS 3384 use in waterproofing treatment and laying APP polymer membrane minimum weight 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric ( wt. not less than 150 gms/ sqm ) land on primer surface by force application complete all as specified & finish and sealing all the over laps of 75 mm in length side and 100 mm on the width side of membrane by torching the same all as per manufacturer instruction. |
| 6 | Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water remove Dust, debries/ rubbish etc., complete all as specified and as directed. |
| 7 | M&L Rendering 15mm thick in Cement Mortar 1:4 (External) on Brick Walls or on Concrete Surfaces in two Coats, 1st Coat of 10mm thick in C:M 1:6 and 2nd Coat of 5mm thick in C:M 1:4 including mixing of liquid WPC for IInd layer @100 ml in each bag of cement , Plastered Surfaces finished Even and fair complete all as specified and as directed. NOTE : Integral Water Proofing Compound shall be Measured and Paid separately as ‘Supply only’ under relevant Items. |
| 8 | Supply only liquid water proofing compound |
| 9 | S&F GI wire netting 0.9mm dia and 12 mm mesh lathing to wood or metal studding, joists etc in walls, ceilings, stanchions, beams etc including all laps, cutting and waster, fixed in repairs in patches n exc 5.0 sqm each, including taking down old and jointing new to old as reqd. |
| 10 | M&L for preparation of new plasterd surfaces and applying two coats of exterior emulsion paint (in camouflage pattern as approved by the GE) over a coat of primer all as specified and directed by EIC using any one of following material or equivent:-Make BrandNerolac SurakshaAsian ACEBerger Walmasta-7D 2456 |
| 11 | M&L for preparation of plastered or unplastered old decorated external surfaces of walls by Vaccum Based sanding machine and applying one coats of exterior emulsion paint in camouflage pattern as approved by the GE, all as specified and directed using any one of following material :-Make BrandNerolac SurakshaAsian ACEBerger Walmasta -7D2456 |
| 12 | M&L for rendering 5 mm thick cement plaster in C:M 1:3 on ceiling surface finished even and fair complete all as specified and as directed. |
| 13 | M&L preparing new plastered Surfaces of Ceiling and applying Three Coats of White Wash, complete all as specified and as directed. |
| 14 | M&L for preparation of old treated surface of ceilings and applying one coats of white wash complete all as specified and directed by EIC. |
| 15 | M&L for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and fair all as specified. |
| 16 | M&L for preparing new surfaces of walls and applying 2mm thick wall care putty finished even and smooth and applying two coat of distemper oil emulsion complete all as specified and directed. |
| 17 | M & L for complete removal of existing treatment from old decorated plastered surfaces of walls by Vaccum based sand machine complete all as specified, removal of nails etc and filling cracks/holes by applying 2 mm thick wall care putty finished even and smooth and applying two coat of oil emulsion distempher white or coloured by auto roller complete all as specified and directed by EIC. |
| 18 | M&L for preparation of old painted sufaces of any description, over 10 cm in width or girth, not otherwise described and applying one coats of synthetic enamel paint on wooden surfaces on roof coverings in camouflage pattern (as approved by GE) , complete all as specified and as directed. |
| 19 | Demolition Cement Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed. |
| 20 | Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron all as specified and as directed |
| 21 | M&L for Providing and injecting chemical emulsion for Antitermite Treatment Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area |
| 22 | M&L for Antitermite Treatment Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) |
| 23 | M&L for Antitermite Treatment Treating the top surface of filled earth at the rate of 5 litres of emulsion per squaremetre of surface |
| 24 | M&L for Antitermite Treatment Treating the soil under plinth protection at the rate of 5 litres of emulsion per squaremetre of surface area |
| 25 | M&L Cement Concrete C2 1:3:6 (40mm graded aggregate), 75mm thick as in Plinth Protection, etc., laid in alternate bays, finishing Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 26 | Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade 'B' complete all as specified and as dircted |
| 27 | Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards /Blankets/Slabs, any description and any thickness including Cover Fillets, Cornices, etc., complete all as specified and as directed. |
| 28 | S&F for false ceiling of perforated particle board/tiles 60X60 cm in size and 12mm thick fixed with nails to timber frame work or with staples on snap grid fixed with screws all as specified and directed. |
| 29 | S&F for anodised aluminium snap grid frame work for false ceiling all as specified and directed . |
| 30 | M&L for providing 12mm thick Gyp boards in ceilings fixed to ceiling sections with screws @ 300mm centre to centre and making good joints Gypsum binder including preparing the surfaces of ceiling boards and applying 2 coats of acrylic oil emulsion distemper with GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre, intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofits at approxly 900mm centre to centre with GI cleats, GI suspenders and steel expansion fasteners with and including ceiling section of 0.55mm thick having kurled web of 50 mm and flange of 26 mm each side with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre all as specified as directed. |
| 31 | M&L for false ceiling corners with designed angular shape of size 100x100mm with POP fixed on 6mm thick fibre board with 20x20mm, 0.55mm thick galvanised sections fixed at intervals not more than 750mm complete al as specified and directed by Engr-in-Charge |
| 32 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 33 | Demolition of stone masonry built in cement mortar including all quoins arches pillars etc but excluding ashlar facing works , dressed stone and precast concrete article. |
| 34 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises |
| 35 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete . |
| 36 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surface |
| 37 | M&L for 40 mm thick PCC 1:2 :4 type B-0 (using 12.5 mm graded stone aggregate) as in DPC or coping to horizontal or vertical surfaces incl necessary form work. |
| 38 | M&L for M-25 (Design Mix)Cement concrete as in foundation, including rafts footings, footing, foundation beams plinth beam and bases of columns and mass concrete. |
| 39 | Use and waste of formwork to coloumns rough finished surfaces or concrete square, retangular etc |
| 40 | M&L for providing reinforced cement concrete M-25 (Design Mix) Columns pillars, piers, posts and struts. |
| 41 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also spays between floors and beams, etc. |
| 42 | M&L for providing reinforced cement concrete M-25 (20 mm graded aggregates) Beams, cantilevers, bressummers, lintels over 1.5m span. |
| 43 | M&L for Use and waste of formwork to soffits of suspended slabs such as roofs slabs, floor slabs, landings and similar work n.exc 200 mm thick (Horizontal or sloping) |
| 44 | M&L for providing reinforced cement concrete M-25 (Design Mix) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 45 | S&F MS TMT bars 10 mm dia and over cut to length bent to shape required incl, cranking bending spirally for hooping for column hooking ends binding with and incl MS wire (annealed) not less than 0.9 mm dia |
| 46 | S&F MS TMT bars 5 mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.complete all as specified and as directed |
| 47 | M&L for MS TMT bars 6 to 8mm , cut to length bent to shape required, and binding with MS wire not less than 0.9mm dia. |
| 48 | M&L for block masonry with precast cement concrete type 1:3:6 (20mm graded aggregate) solid blocks exc 10cm in width and setting in cement mortar 1:6. |
| 49 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM-1:6 complete all as specified. |
| 50 | M&L for Glazed Ceramic coloured Tiles, 350X250X7mm/ 450X350X7mm thick in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed. |
| 51 | M&L for Vitrified Ceramic tiles light shade 9-10 mm thick Colour (square/rectangular) polished, area of each tiles exc .18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including Screed Bed 15 mm thick in Cement Mortar (1:6) complete all as specified and as directed. |
| 52 | All as per item No.51 above but as on vertical surfacesbut in CM (1:3) 10mm thick rendering. |
| 53 | Taking up or down Steel Tubing 15mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 54 | Taking up or down Steel Tubing 20mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 55 | S&F 20mm CPVC pipes ISI marked with all fittings fixed with solvent cement complete to walls and ceilings or laid in floors of following sizes: (SDR-13.5 of plain CPVC) |
| 56 | S&F 25mm CPVC pipes ISI marked with all fittings fixed with solvent cement complete to walls and ceilings or laid in floors of following sizes: (SDR-13.5 of plain CPVC) |
| 57 | S&F in repairs wash down water closet (pedestal pattern) complete whitecomplete all as specified and directed. |
| 58 | S&F in repair vitreous china squatting pan `Orissa’ pattern, size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with ‘P’ or ‘S’ trap including provision of lime concrete bedding complete all specified and directed. |
| 59 | S&F in repairs 10 ltr capacity PVC valve less symphonic action type flushing cistern, white ,with inlet ball valve, float and handle including bracket and 32 mm dia HDPE flush pipe and connected to squat pattern /pedestal pattern water closet (Flush shall be fixed at suitable height for smooth functioning ) complete all specified and directed. |
| 60 | S&F in repair plastic water closet(EWC) seat cover white closed pattern with flat bottom and cover incl mild steel chromium plated hinging device complete all as specified. |
| 61 | Supply and fixing in repair Health faucet (ABS Body) mild steelchromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including makingconnections and fixed in position complete in all respect as specifiedHealth faucet including 1.00m flexible pipe with brass nuts for EWC, as approved complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F in repair Vitreous China half stall urinals bowel type (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 secuing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement, with brackets flush pipe grating and union fo dischage pipe |
| 63 | S&F in repair vitreous china wash basin white, flat back 580x 450 mm excluding taps, waste, chain plug and porcelain stopper incl bracket |
| 64 | S&F in repair of Table top rectangle shaped white Matte Basin WHB area (Jaquar Designer Range) cart Part No JDS WHM 25907N ,fixed in repair, complete all as specified |
| 65 | S&F in repairs Waste coupling of PTMT 32 mm for wash basin and min wt 45 or 60gms complete all as specified |
| 66 | S&F in repair waste pipe of polyethylene of low or high density or PVC ,32 mmdia for urinal/wash basin/ flush tank fixed in repairs. complete all as directed by Engr-in-charge. |
| 67 | S&F in repair Grating square 150 mm size of PTMT(Minimum weight 100gms)all as directed by the Engr-in-Charge |
| 68 | M&L for granite (of any colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform, counter for wash basin, flooring , urinal partition and all other similar works over a screed bed of 20mm 1:6(CM) complete all as specified and directed. |
| 69 | M&L for Cutting chases, in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and as directed. |
| 70 | M & L for Rounding to edges of stone slabs one edge,such as in steps, cooking platform, and other similar situations all as per specified and directed. |
| 71 | S&F in repairs PVC connection 15mm bore with PTMT nuts and 600mm long. |
| 72 | S&F in repair 15mm dia Bib taps, cast copper alloy fancy type chromium plated, screwed for iron pipe or for brass ferrule and fixed |
| 73 | S&F in repair 15mm bore pillar tap swan neck type, cast copper alloy, with capstan heads, fancy type chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 74 | S&F in repair Angle Valve 15 mm bore chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions complete all as specified |
| 75 | S&F in repair CP Soap Dish Holder Make :Jaguar or equivalent make of Parriware /Hindware(Cart Part No : CPA-1131) |
| 76 | S&F in repair Toilet Roll Holder with flap fixed to walls with chromium plated screws complete all as directed. |
| 77 | S&F in repair brass chromium plated tubular towel rail 20 mm dia `D’ type 60 cm long between flanges |
| 78 | S & F in repair Gun-metal, globe or gate valves, 20mm with iron wheel head, screwed both ends for iron pipe and fixed. |
| 79 | S&F in repair 6mm thick frame less bevelled edge mirror fixed with steel stud as per direction of Engineeer in -charge . |
| 80 | M&L in repair PVC (SWR) Nahni trap of 75 mm with grating incl jointing and waste pipe fixed in cement concrete type B1 (1:2:4) |
| 81 | M&L for PVC (SWR) gulley trap 125/110 mm setting and jointing with solvent cement |
| 82 | Supply and fixing Rotational moulded polythelene water storage tank of 750 litre capacity ISI marked, cylindrical vertical with closed top including dismantling existing water tank and removing to store of following capacity. (Make - Sintex / Euro / Cera) |
| 83 | S&F in repair brass ball valve high pressure with polyethylene float and ply nut complete screwed for iron pipe or for brass ferrule and fixed bore of pipe 20 mm size |
| 84 | Dismantling of cast iron,PVC or reinforced concrete pipes bore of pipe 100mm dia jointed in cement mortar and taking out of trenches, if required all as directed by Engr-in-charge following |
| 85 | S&F 75mm PVC SWR pipes single socketed, in any length with rubber ring joints laid in trenches or in floors |
| 86 | S&F 75mm PVC SWR pipes single socketed, in any length with rubber ring joints fixed to wall complete all as specified |
| 87 | S&F 110mm PVC SWR pipes single socketed, in any length with rubber ring joints laid in trenches or in floors |
| 88 | S&F 110mm PVC SWR pipes single socketed, in any length with rubber ring joints fixed to wall complete all as specified |
| 89 | S&F 75mm bore PVC SWR bends of any radius complete all as spcified. |
| 90 | S&F 110 mm bore PVC (SWR) vent cowl, complete all as specified |
| 91 | M&L for PVC (SWR) branch piece single (single ‘Y’) equal or unequal with oval access door suitable for 75mm bore pipe with access door. |
| 92 | M&L for PVC (SWR) branch piece double (double ‘Y’) equal or unequal with oval access door suitable for 75mm bore pipe with access door. |
| 93 | M&L for PVC (SWR) branch piece single (single ‘Y’) equal or unequal with oval access door suitable for 110mm bore pipe with access door. |
| 94 | M&L for PVC (SWR) branch piece double (double ‘Y’) equal or unequal suitable for 110mm bore pipe with access door. |
| 95 | M&L for PVC (SWR) branch piece Single (Single’T') equal or unequal suitable for 110mm bore pipe. |
| 96 | M&L for PVC (SWR) branch piece Single (Single’T') equal or unequal suitable for 75mm bore pipe. |
| 97 | Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqm each. |
| 98 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 99 | S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing |
| 100 | Taking down Chowkaht or frame (without taking off shutter from frame) n.exc. 1.50 Sqm. |
| 101 | S & F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 102 | S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete all as specified |
| 103 | S&F Galvanised mild steel wire cloth,0.56mm nominal dia of wire and average width of aperture 1.00mm all as specified. |
| 104 | S & F tinted sheet glass 5.50mm thick, selected quality and glazing with rubber beading in squares NOT exc 0.5 sq. m in each pane for fixing in aluminium sliding windows. (Note:- Rubber beading measured and paid separatelly) |
| 105 | Demolition of cement concrete in ground floor and pavings n.exc 15cm thick below or above ground level and removing demolised material out of Military station. |
| 106 | M&L for Cement concrete type B-2,1:4:8 (40mm graded aggreate) 100 mm thick as in sub -floors ,sub- bases ,floors and pavings,etc.. |
| 107 | M&L for 150 mm thick PCC in 1:4:8 type D2(using 40 mm graded stone aggregate) as in sub base of floor finished even and fair complete as specified. |
| 108 | M&L for 120 mm thick PCC in 1:2:4 type B2(using 40 mm graded stone aggregate) as in sub base of floor finished even and fair complete as specified. |
| 109 | M&L for 30 mm thick PCC in 1:2:4 type B1(using 20 mm graded stone aggregate) as in floor finished even and smooth usinf extra cement complete as specified. |
| 110 | M&L for PCC in 1:2:4 type B1(using 20 mm graded stone aggregate) 50 mm thick and finishing cement conc. Surface in sub base. |
| 111 | Providing, cement concrete 1:2:4 type B-0(using 12.5 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates. |
| 112 | M&L for sand filling under floors in foundations and for laying Interlocking paver blocks including watering and consolidation complete all as specified and as directed by Engr-in-Charge.. |
| 113 | M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement & pigment complete all as specified and directed. |
| 114 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 115 | S&F in Mild steel, plain, blacksheet 1.00 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded,seams, including bending or turning up, mitred angles, etc. as required. |
| 116 | S&F Framed work as in doors or gates of angle or other ection with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. |
| 117 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 118 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing boltsposts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 119 | M&L for applying two coat of synthetic enamel paint on new steel surface over a coat of red oxide incl preparation of surface of any description over 10 cm width or girth.. |
| 120 | M&L for Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement icluding forming moulds etc in surface channel and drains. |
| 121 | M&L for cement concete type B-2,1:2:4 mix (using 40 mm grade aggregate) as in surface channels and drains including necessary form work complete. |
| 122 | Removal of damaged concrete along with loose damaged and cracked concrete/cover concrete at all specified locations up to beyond the corroded steel reinforcements to a depth of 10 mm min behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer , pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement and removal and disposal of debris within owners premises including all plant and machineries. Note : Rates quoted for all items should include all necessary scaffolding , staging etc. complete all as specified and as directed. HSE Guidelines : Recommende to wear tightlifting dust -resistant goggles and mask during breaking and surface grinding works etc. |
| 123 | M & L for Cleaning as directed & specified all rust/ scales/corrosion from reinforcement bars using rust remover Reebaklens RR- Rust remover, cleaning and etching agent supplied in 1/2, 1 and 5 Litre containers, having Specific Gravity 1.16 - 1.22 @ 25°C. Reebaklens RR cleaning agent is a combination of acid based material, corrosion inhibitors and dispersing agents and is supplied as a clear green solution.Application of Reebaklens RR with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours followed by cleaning the surface with wire brush and washing surface with fresh water as required to exposed reinforcement bars complete as specified.Note : Rates quoted for all items should include all necessary scaffolding , staging etc complete all as specified and as directed. HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. |
| 124 | M & L for corrosion protection by applying Nitozinc Primer- Two component epoxy zincrich primer supplied in 1 and 5 Litre pack, two component system based on metallic zinc and epoxy resin which on mixing gives a grey coloured liquid. An Anti corrosive coat contents Active 'Zinc-rich' system which combats corrosion by electro chemical means. having specific gravity of 1.75, Adhesive bond strength > 1.5 N/mm2 Solid content- 60 %, 40 microns DFT, Fully dry/Recoatable- 45 minutes to 1 hour.Typical application includes surface preparations by cleaning steel surface to a bright condition paying particular attention to the back of exposed steel bars, mixed two components slow speed heavy duty drill fitted with a paddle, applying unbroken coat with suitable brush and allow to dry, after 30 mins apply second coat to ensure complete cover to exposed steel/ rebar etc complete. Total Dry film thickness is 40 microns. HSE Guidelines : Nitozinc Primer and Nitofl or Sol should not come in contact with the skin and eyes, or be swallowed. Adequate ventilation should be ensured and inhalation of vapours should be avoided. suitable protective clothing, gloves and eye protection shall be worn. If working in confined areas, suitable respiratory protective equipment must be used. The use of barrier creams, provide additional skin protection. Incase of contact with skin, it shall be rinsed with plenty of water, then cleansed with soap and water. Note : Rates quoted for all items should include all necessary scaffolding , staging etc complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 125 | M & L for corrosion protection by applying Nitozinc Primer- Two component epoxy zincrich primer supplied in 1 and 5 Litre pack, two component system based on metallic zinc and epoxy resin which on mixing gives a grey coloured liquid. An Anti corrosive coat contents Active 'Zinc-rich' system which combats corrosion by electro chemical means. having specific gravity of 1.75, Adhesive bond strength > 1.5 N/mm2 Solid content- 60 %, 40 microns DFT, Fully dry/Recoatable- 45 minutes to 1 hour.Typical application includes surface preparations by cleaning steel surface to a bright condition paying particular attention to the back of exposed steel bars, mixed two components slow speed heavy duty drill fitted with a paddle, applying unbroken coat with suitable brush and allow to dry, after 30 mins apply second coat to ensure complete cover to exposed steel/ rebar etc complete. Total Dry film thickness is 40 microns. HSE Guidelines : Nitozinc Primer and Nitofl or Sol should not come in contact with the skin and eyes, or be swallowed. Adequate ventilation should be ensured and inhalation of vapours should be avoided. suitable protective clothing, gloves and eye protection shall be worn. If working in confined areas, suitable respiratory protective equipment must be used. The use of barrier creams, provide additional skin protection. Incase of contact with skin, it shall be rinsed with plenty of water, then cleansed with soap and water. Note : Rates quoted for all items should include all necessary scaffolding , staging etc complete all as specified and as directed. Please Enable Macros to View BoQ information |