| 1 | Taking down of old existing roof treatment / mud phushka / tiles / brick coba from roof surfaces etc including cleaning ,brushing and watering to joints and grooves and throwing the same to a distance exc. 250 mtr and not exc 500 mtr from the roof etc complete all as specified and directed. |
| 2 | M&L for repair of All visible hairline cracks on concrete roof / screed more than 0.50 mm and not giving hollow sound, should be cut and widen in V shape with mechanical cutter in the size (10mm W x 6mm D). Fill cracks with PU sealant / Hybrid Sealant with suitable gun and smoothed with a putty knife or trowel. Allow sealant to cure a minimum (72 Hrs.) 3 days etc complete all as specified & directed. |
| 3 | Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 4 | M&L for Plain cement Concrete 1:2:4 type B-0 ( 12.5 mm graded aggregate) 25 mm thick average as in roof padding including water proofing compound 200ml per 50 Kg of cement etc complete all as specified & directed. Note :WPC shall be measured and paid seperately. |
| 5 | Supply only liquid integral water proofing compound etc complete all as specified and directed. |
| 6 | M&L for apply a bond coat of Pidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on the pre wet surface before application of primer coating on roof where required etc complete all as specified & directed. |
| 7 | M&L for Apply one coat of primer after dilution of water proofing chemicals in the ratio of 1:1 in complete dry condition where moisture contain below 7% (should be checked with moisture meter). Allow the primer coat to dry for 6 to 8 hours. Apply 1st coat of Roof seal Classic or equivalent water proofing chemical without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4 to 6 hours. Apply the second of chemical with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application. Check to see no void surface is left untreated / uncoated.Allow the system to air cure for 7 days minimum etc complete all as specified & directed. |
| 8 | Demolition of brick work or stone masonry including all quoins,arches,pillars etc built in CM complete all as specified & directed. |
| 9 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified & directed. |
| 10 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick built in CM 1:4 complete all as specified & directed. |
| 11 | Taking down cement or cemant lime plaster of any discription on bricks or stone walls/ceiling etc including racking out joints, hacking for kay, scrubbing down with water (upto height of G+2) complete all as specified and directed. |
| 12 | M&L for 10 to 12 mm thick smart care ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer instructions) over exterior surface of wall (upto height G+2) etc complete all as specified & directed. |
| 13 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on new surfaces (upto height G+2) complete all as specified and directed |
| 14 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on old surfaces incl. complete removal of existing treatment (upto height G+2) etc complete all as specified and directed. |
| 15 | Disconnecting existing water tanks setting a side capacity exc 250 & n exc 500 ltrs and repairing,cleaning and removing all scale and dirt etc from tanks and from mouths of circulaiting pipes and cleaning with bleaching powder,hoisting if required/removing and re-fixing in same and writing Date of Cleaning including old or new fitting etc all as directed. |
| 16 | Disconnecting existing water tanks setting a side capacity exc 500 & n exc 1000 ltrs and repairing,cleaning and removing all scale and dirt etc from tanks and from mouths of circulaiting pipes and cleaning with bleaching powder,hoisting if required/removing and re-fixing in same and writing Date of Cleaning including old or new fitting etc all as directed. |
| 17 | S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PVC float valve with epoxy coated Aluminium rod & nipple of 15 mm complete all as specified in SSR Part I including dismantling of storage tank complete all specified & directed |
| 18 | S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PVC float valve with epoxy coated Aluminium rod & nipple of 15 mm complete all as specified in SSR Part I including dismantling of storage tank complete all specified & directed |
| 19 | Taking up or down 20 mm dia steel tubing /PPR pipe connections etc ,including cleaning for Refixing or removal to store complete all as specified and directed. |
| 20 | S&F 20 mm bore GI tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 21 | Taking up or down 15 mm bore steel tubing including fittings and connections, including cleaning for Refixing or removal to store complete all as specified and directed. |
| 22 | S&F 15 mm bore Galvanized Steel tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 23 | S&F in repair 20 mm outer dia gun metal gate valve with iron wheel head both ends screwed complete all as specified and directed. |
| 24 | S&F in repair 20 mm dia PVC float Valves high pressure, with polythene float and fly nut complete,screwed for Iron pipe or brass ferrule complete all as specified and directed. |
| 25 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories. |
| 26 | S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall / floor complete all as specified and directed. |
| 27 | S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed. |
| 28 | S&F 110 mm PVC (SWR) junction single (T single) equal or unequal with acess door. complete all as specified and directed . |
| 29 | S&F in repairs 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed. |
| 30 | S&F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and cement joint including making good disturbe portion to match the existing complete all as specified and directed. |
| 31 | S&F in repairs 100 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturbe portion to match the existing complete all as specified and directed. |
| 32 | S&F PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors, wall including fittings dismantling etc confirming to IS 13592 complete all as specified and directed. |
| 33 | S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 34 | S&F in repairs 75 mm PVC (SWR) junction single (T single) equal or unequal.with access door.complete all as specified and directed . |
| 35 | S&F in repairs clamps out of 50 mm by 5 mm flat iron fixed with suitable bolt / screws securing ends of stays to wall or roof for PVC (SWR) / CI Pipe for 100 mm bore pipe complete all as specified & directed. |
| 36 | S&F in repairs clamps out of 50 mm by 5 mm flat iron fixed with suitable bolt / screws securing ends of stays to wall or roof for PVC (SWR) / CI Pipe for 75 mm bore pipe complete all as specified & directed. |
| 37 | M&L for Providing cement concrete 1:2:4 type B1 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges or water tank staging etc complete all as specified and directed. |
| 38 | M&L for Providing cement concrete 1:2:4 type B0 using 12.5 mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed. |
| 39 | Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed. |
| 40 | S & F powder coated aluminium window and ventilator shutters including frame, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. Please Enable Macros to View BoQ information |