| 1 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying of CI/GI pipes laying in trenches and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning, filling in trenches including, leveling watering and well ramming in layers not exc 25cm in soft/loose soil, complete all as specified and directed by Engr-in-Charge. |
| 3 | Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 4 | Material and labour construction of brick masonary valve pit of size 1200mm x 1200mm x 1200mm (Internal size) thickness of walls shall be 23cm in brick work in cm 1:6 internally plastered in cm (1:6) and externally plastered in cm (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15m offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 as the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge . |
| 5 | Material and labour construction of brick masonary valve pit of size 900mm x 900mm x 900mm (Internal size) thickness of walls shall be 23cm in brick work in cm 1:6 internally plastered in cm (1:6) and externally plastered in cm (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15m offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 as the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge. |
| 6 | Demolition of stone or brick masonry built in cement mortar including all quoins, arches etc. but excluding ashlar facing, dressed stone work etc, complete all as specified and directed. |
| 7 | Material and labour for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 8 | All as per ser item No. 7.00 here in before but except brick complete all as specified and directed by Engr-in-Charge.Note:- Serviceble Old bricks obtain from ser item No 6.00 shall be reused after cleaning. |
| 9 | Material and labour for 15mm thick cement plaster in cement mortar 1:4 on fair faces of brick walls or concrete external surfaces finished even & fair without using extra cement, complete including white wash, complete all as specified and directed by Engr-in-Charge. |
| 10 | Demolition of cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engr-in-Charge. |
| 11 | Material and labour for PCC 1:2:4 type B1 using 20mm graded mechanically crushed stone aggregate as in coping and foundations for DG etc, complete all as specified and directed by Engr-in-Charge. |
| 12 | Supply and fix valve pit cover with angle iron frame size 40mm x 40mm x 6mm , MS sheet cover 3.15mm thickness , MS sliding bollt and pad locking arrangement alongwith painting of pit cover etc including taking out old or damaged valve pit cover, complete all as specified and directed by Engr-in-Charge. |
| 13 | Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for crossing of water pipe line GI/DI size upto 200mm dia, complete all as specified and directed by Engr-in-Charge. |
| 14 | Supply, fixing and testing in replacement of Contactor capacity range 250A, 3P, 440V, Electric Pump rating 90 KW , Discharge 171 Cum/Hrs ( Model No LC1E250) Amps alongwith all connected items( lugs etc properly) complete all as per specified and directed by Engr -in-Charge. |
| 15 | Supply and fix in replacement for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 25mm x 6mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 16 | Supply and fix in replacement for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 25mm x 6mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |