| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 2 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 3 | 25 mm thick lime Plaster in two coats, backing coat,15mm thick in 1 lime : 2 surkhi mortar and finishing coat, 10mm thick in 1 lime : 2 surkhi mortar on fair side of stone/brick tile walls : Inside room. |
| 4 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 5 | Raking out joints of stone masonry surface to the required width and depth, with due care and precaution by mechanical/manual means including preparing and cleaning the surface for re-pointing / refilling of joints, including disposal of rubbish to the dumping ground within 50 mtrs lead. |
| 6 | Flush point on Brick masonary with lime surkhi mortar (1:1) pointing (outside Rooms). |
| 7 | Providing and laying in situ five course water proofing treatment with APP (Atactic Poly Propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film, 5th top most layer shall be finished with brick tiles of class designation 100 grouted with cement mortar 1:3 (1 cement : 3 Fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). |
| 8 | Tile brick masonry work 5cm thick with common burnt clay non modular tile bricks of class designation 10 in cement mortar 1:3 (1 cement : 3 coarse sand) and curing complete in superstructure above plinth level upto floor five level. |
| 9 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. |
| 10 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below |
| 11 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for Separately): Sal wood |
| 12 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. Pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood 35 mm thick |
| 13 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 14 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 15 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In lime mortar |
| 16 | Tile brick masonry with common burnt clay tile bricks of class designation 10 in foundation and plinth including curing complete in: Lime mortar 1:1:1 (1 lime putty : 1 surkhi : 1 fine sand) |
| 17 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 18 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 19 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate. |
| 20 | 40mm thick fine dressed stone flooring over 20mm (average) thick base of cement mortar 1:5 (1 cement: 5 coarse sand) with joints finished flush and curing complete: White sand stone |
| 21 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) with all leads and lifts carriage complete. |
| 22 | Providing and applying lime kara 1:2 (1 lime cream : 2 zikki powder) grinding mortar with grinding mill / manually (on lime sand / sand plaster base) on ceiling / curved lime plaster in two coats. First coat applying 3 mm to 4 mm thick and curing properly atleast 7 days, second finishing coat done after 7 days of previous coat as per traditional practice (Thickness not more than 6 mm). |
| 23 | Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with: Makrana White Second quality 16 mm |
| 24 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 25 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 26 | Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.) In rows 5 cm apart in either direction |
| 27 | Providing and applying two coats (basic white and terracota) of protect guard colour including applying two coat of primer coat (Imperguard SF) as per approved by architects, on exposed brick work and lime based exterior surface of the building including scaffolding, preparing the surface, watering, curing etc. complete and as directed by the architect and engineer-in-charge. |
| 28 | Supplying and stacking at site dump manure from approved source including carriage complete (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of I.S. designation 20 mm |
| 29 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 30 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement lime mortar 1:1:6 ( 1 cement : 1 lime putty : 6 fine sand) Please Enable Macros to View BoQ information |