| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 2 | Of area beyond 3 sq. metres |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 4 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 5 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 6 | 100 mm dia pipe |
| 7 | 75 to 80 mm dia pipe |
| 8 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 9 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 10 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 11 | Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) & French (False) mullion (55 mm & above) x (60 mm & above). (Height upto 2.5 metre). |
| 12 | Fixed window/ ventilator with mullion /transom.Using R2 series with frame (39 mm & above) x (39 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre) |
| 13 | Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete. |
| 14 | Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete. |
| 15 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 16 | Upto 5 mm depth and 5 mm width |
| 17 | Providing and fixing glazing in uPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. |
| 18 | With tinted glass panes of 12mm thickness |
| 19 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 20 | Float glass panes5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 21 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 22 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 23 | 1:2:4 (1 Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 25 | Foundations, footings, bases for columns |
| 26 | Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 27 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 28 | Ordinary cement without any pigment |
| 29 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 30 | Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 31 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 32 | Providing and applying two coats of an anti carbonation coating with Dr. Fixit Concrete guard WB or equivalent on the prepared substrate to protect them from the adverse environmental conditions after the surface is properly prepared applying priming coat of Dr. Fixit concrete guard WB or equivlanet brush or sparay diluting in 1:1 proportion with water, the primer coat shall achieve coverage of approx.. 10.00 Sqm/litre. Allow it to day for 2-3 hours before application of finishing coat apply two neat coats of Dr. Fixit concrete guard WB or equivalent without any diluting finishing coat (undiluted) 4.00 sqm/ltr (two or more coats) concrete surface time interval between two coats is 6-8 hours. The technical properties are as follows: (a) Solid content of 71% + 3 as per IS 101 part 8 sec 2.(b) Adhesion to concrete 3N/mm2 as per ASTMD 4541:2017(c) Tensile strength = 2N/mm2 as per ASTMD638:2014(d) Elongation = 200% as per ASTD & 38:2014(e) Tear Strength of 1532 N/mm2 as per ASTD 624:2020 |
| 33 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 34 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface Please Enable Macros to View BoQ information |