| 1 | Dismantling old AC sheet corrugated / CGI corrugated sheets,asbestos sheet in roofing any gauge and any thickness including ridge, valley/gutter etc. complete as specified and directed |
| 2 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/ eaves board fixed with selp tapping screw complete all as specified and directed. |
| 3 | S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/eaves board fixed with selp tapping screw complete all as specified and directed. |
| 4 | M & L for taking down roof trusses, coupled rafters or trussed beams with span above 4 mtrs and upto 12 mtrs |
| 5 | S&F Rolled mild steel Roof trusses (framed), trussed purlins crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. GDE Fe410-0 or Fe 310-O |
| 6 | S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates GDE Fe410-0 or Fe 310-O |
| 7 | M&L of two coat of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth incl preparation of surfaces complete all as specified and as directed. |
| 8 | Dismantling wall / ceiling board (fibre pulp insulation) or insulation boards any thickness including cover fillets |
| 9 | S & F Aluminium anodised snap grid frame work for false ceiling of grid size 605 x 605 mm as specified and suspended with Hangers 6 mm dia. G.I. complete all as specified all as specified. |
| 10 | S&F for 4 mm thick Non asbestos fibre cement building board (E- Board) for fixed to Aluminium frame work with screws as in ceiling complete as specified and as directed. |
| 11 | M & L for preparation of new surfaces over ceiling and applying two coats of oil bound distemer over a coat of priming on board complete all as specified and directed. |
| 12 | Demolition of brick work built in cement mortar. |
| 13 | M&L for brickwork with old size subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete as specified and directed |
| 14 | M&L for brickwork with old size subclass `B' bricks, straight or curved on plan exc 6m mean radius in CM (1:6)built in half brick thick wall complete as specified and directed |
| 15 | Taking down plaster on brick or stone wall, etc incl racking out joints hacking for keys scrubbing down with water etc complete all as specified and directed.etc. |
| 16 | M & L 10 mm thick rendering on fair faces of brick work or concrete surface in cm 1:6 to be finished fair and even with out suing extra cement. |
| 17 | M&L for 15 mm thick cement plaster in cement mortar 1:4 as on brick surfaces ,concrete surfaces fins etc complete all as specified and directed |
| 18 | M& L for 2mm thick Wall care putty on wall Surface and preparation of new surface compete all as specified and as directed |
| 19 | M &L for two coat of cement based paint over alkaline primer as per manufactures instruction on external surfaces of walls and preperation of new surfaces complete as specified and directed |
| 20 | M & L two coat of Oil bound distemper over a coat of primer complete in new wall surfaces all as specified and as directed |
| 21 | M & L for two coat of cement based paint over alkaline primer as pewr manufacturer instruction on external surfaces of walls and preperation of old plasterd surface completet all as specified |
| 22 | M & L two coat of Oil bound distemper over a coat of primer in old surfaces complete all as specified and as directed |
| 23 | M & L Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) and preparation of new plastered surface complete all as specified and directed |
| 24 | Taking down chowkat with shutter/without taking off shutter from the frame exe 1.50 Sqm but n.exc 4.00 Sqm each complete all as specified and directed. |
| 25 | S&F Steel door including projecting type hinges, steel handle,complete, with glazing bars, dovetailed or welded complete as specified and directed |
| 26 | M&L Plain cement concrete in bed block and filling of door frame type C-1 1:3:6 (20 mm graded stone aggregate) complete all as specified . |
| 27 | M&L mild steel work as in holdfast and similar works conforming to Fe290 GDE E-165 complete all as specified and as directed. |
| 28 | Taking down chowkat with shutter/without taking off shutter from the frame n exe 1.50 Sqm each complete all as specified |
| 29 | S&F Powder coated aluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge and making good the surface incl taking down the old window complete all as specified . |
| 30 | M&L mild steel work such as grills, guard bars etc and similar work conforming to Fe290 GDE E-165 complete all as specified and as directed. |
| 31 | M&L for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, n exc 10cm width or girth including preparation of new surface & applying one coat of red oxide primer complete all as specified . |
| 32 | Material and labour 75 mm thick PCC 1:3:6 type C2 using 40 mm graded aggregate as in plinth protection finished fair and even w/o using extra cement and making groove of 10mm width at every 3m intervals and at diagonals and filling the joints with bitumen mastic( a mix of bitumen and sand in 1:1 by weight) complete all as specified . |
| 33 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified . |
| 34 | M&L machine cut kota stone slab flooring 20-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over 20 mm thick screed bed or bedding layer of mortar in CM 1:6 for laying kota stone , including rubbing and polishing complete all as specified and as directed |
| 35 | All as per item No. 34 above but as in dado/skirting,riser etc to be cutting required size of the slab over 15 mm thick backing layer of mortar in CM (1:4) complete as specified and directed |
| 36 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully and keep aside serviceable materials for taking credit including making good of the disturbed surfaces, all as specified and directed. |
| 37 | Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site including suitable size of GI boxes of thickness not less than 0.8 mm thick and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan point controlled by one way switch complete all as specified as directed. Note for item Nos.2 to 5: (i) Cost of cutting of wall, if any, for housing of GI box, ceiling rose, etc and also making good the disturbed surfaces are deemed to be included in unit rate.(ii) Cost of GI box of suitable size shall be deemed to be included in the qouted rate . |
| 38 | All as per item No 37 above but for one 3/5 pin 6 Amps socket outlet on the same board with other switches. |
| 39 | All as per item No 37 above but for one 3/5 pin 6 Amps socket outlet on the independent board. |
| 40 | Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 2.5 sqmm (nominal area) for phase, neutral and 2.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site including suitable size of GI boxes of thickness not less than 0.8 mm thick and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan point controlled by one way switch complete all as specified as directed. |
| 41 | Material and labour for switch socket combination multi purpose 2 in 1, 5 Pin,6 and 16 Amps, flush type complete all as specified and as directed. |
| 42 | Materials & labour for switch piano flush button 6 Amps single pole, 1 way complete all as specified and as directed. |
| 43 | Material and labour for switch socket combination 5 Pin, 6 Amps flush type complete all as specified and as directed |
| 44 | Materials and labour for socket out let 5 Pin, 6 Amps flush type complete all as specified and as directed. |
| 45 | Materials and labour for ceiling rose surface bakelite, 65 x 50mm, three terminals complete all as specified and as directed. |
| 46 | Materials and labour for electronic fan regulator (step rotary type), AC 240 volt complete all as specified and as directed. |
| 47 | Supply & fixing MCB DB (Double door) SPN, 12 way sheet steel with bus bar, din rail, neutral link and earth bar including taking down old DB with fitting & fixtures all as specified and directed. |
| 48 | Supply and fix MCB single pole 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete inculding taking down the old unserviceable one all as specified as directed. |
| 49 | Supply and fix MCB single pole & neutral 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete inculding taking down the old unserviceable one all as specified as directed |
| 50 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete including taking down old unserceable light fitting all as specified and directed. |
| 51 | Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100mm C/C both way and two Nos lifting handle made of 12mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete all as specified in electrical plate No 3 of SSR Part-I including taking down old earthing. |
| 52 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver and integrated tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Including taking down old unserceable light fitting complete all as specified and as directed. |
| 53 | Supply and fix LED light fitting, 1x10/12w bulk head luminaries, with LED lamp, etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size, including taking down the old unserviceable fitting complete all as specified and directed |
| 54 | Excavation in trenches not exceeding 1.5 m width or n exc 10 sqm on plan and n.exe 1.5 m in depth for taking out/laying of cable,foundation etc and getting out in soft/loose soil complete all as specified and as directed. |
| 55 | Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil complete all as specified and as directed. |
| 56 | Removing surplus soil to a distance not exceeding 50 mtrs and depositing where directed including spreading, leveling at a level not exceeding 1.5 mtr from the starting point complete all as specified and as directed |
| 57 | Supply, Laying,connecting,testing and commissioning of XLPE insulated and PVC sheathed ,armoured heavy duty UG cable with stranded alluminium conductors 10 sqmm x 2 core,1100 Volt grade, laid in trenches / surface / wall / roof / pole / through pipe including takingdown old u/s cable,compleate all as specified and as directed Note :- (i) Pipe and bricks for cable protection and sand cushioning shall be measured and paid separately as per site . |
| 58 | Material and labour for sand cushioning with clean dry sand in trenches for cable protection complete all as specified and as directed.Note:- Punned depth shall only be measured and paid. |
| 59 | S & F bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed. |
| 60 | Supply and lay GI pipe 50 mm bore (dia) light grade in trenches/road/surface/pole/wall crossing for protection of cable with necessary fittings as required including takingdown old u/s GI pipe complete all as specified and as directed. |
| 61 | Cutting hard standing / road for laying of cable / protection pipe complete all as specified and as directed. |
| 62 | Material and labour for PCC (1:4:8) type D-2 (using 40mm graded aggregate) for filling and making good of disturbed surfaces of road/hard standing etc complete all as specified and as directed |
| 63 | NOTES :-1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule 'A' notes for details. Please Enable Macros to View BoQ information |