| 1 | Taking down cement plaster, any description, on brick or blockor stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and as directed. |
| 2 | M&L for rendering 15 mm thick in CM 1:6 over block or stone masonary, concrete surfaces, finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 3 | M&L for 15 mm thick rendering on stone block or masonary wall surfaces in CM 1:4 finished fair and even complete all as specified and as directed. |
| 4 | M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed. |
| 5 | M & L for preparation of newly plastered surface on walls and applying two coat of acrylic weather proof paint (Exterior grade) over a coat of primer complete all as specified and directed. |
| 6 | Taking down chowkat or frames n.exc 1.5 sqm with shutters without taking off shutters from the frame and removing to store complete all as specified and as directed. |
| 7 | Taking down chowkat or frames exc 1.5 sqm & n exc 4 sqm with shutters without taking off shutters from the frame and removing to store complete all as specified and as directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 9 | M&L Virified Ceramic tiles light shade 8 to 9 mm thick (square/rectangular) polished/Matt/Glossy, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in epoxy grout and including 15 mm thick screed bed in CM 1:4, complete all as spcified and directed. |
| 10 | All as above but on vertical surface as in skirting/Dados over 8 to 9 mm thick plaster cm 1:4 complete all as specified and as directed. |
| 11 | M& L for applying Cement putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete as all specified and directed. |
| 12 | S&F in repair 150 mm long floor door stopper of a brass body and tongu with hard drawn steel spring, fixed in floor complete all as specified and as directed. |
| 13 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 14 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 15 | S&F (concealed / open)20 mm outer dia CPVC pipes & fittings SDR 13.5 pipes & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl drilling to holes in walls and fixing clamps as required complete all as specified complete with fitting including taking down existing GI tubing 15mm bore complete all as specified and as directed. |
| 16 | S&F (concealed / open) 25mm outer dia CPVC pipes & fittings SDR 13.5 pipes & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl drilling to holes in walls and fixing clamps as required complete all as specified complete with fitting including taking down existing GI tubing 15mm bore complete all as specified and as directed. |
| 17 | Demoltion of stone slabs and tiles of any description of thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed. |
| 18 | S&F Machine cut kota stone slab flooring/slab 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complet as specifed and directed |
| 19 | M&L for 20mm thick Granite jet Black (of any type) work (table rubbed and polished) in cooking plateform, Jambs cill and like set in cement mortar (1:4) inlcuding pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including rounding of exposed edges of slab smoothly and polished complete all as specified and directed. |
| 20 | S&F in repair vitreous china Counter/ Table top Wash hand basin (White) of size (570x420x195 mm) mm complete all as specified and as directed. (Cat No. FLS-WHT-5601) Make: (Make : Jaquar) |
| 21 | S&F Exposed Part Kit of Single Lever Basin Mixer Wall Mounted chrome finish consisting of Operating Lever, Cartridge Sleeve, Wall Flange, Nipple & Spout 15 mm nominal bore complete all as specified and as directed. (Cat No.ARI-CHR-39233NK) (Make : Jaquar) |
| 22 | S&F 32 mm dia brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed. |
| 23 | S&F in repair Bib taps , cast copper alloy screwed down high pressure with crutch or butter fly handle fancy type long body CP for 15mm dia bore GI Pipe or for brass ferrule and fixed complete all as specified Cat No FUS-CHR-29037. (Make : Jaquar) Jaquar) |
| 24 | S&F in repair Stop valves, fancy type chromium plated ISI marked , cast copper alloy, screwed down high pressure for 15 mm bore dia GI tubing pipe, high pressure, with crutch butter fly handle complete all as specified and as directed. Cat part No VGP81053 (Make : Jaquar) |
| 25 | S&F stainless steel health faucet witrh 1 Mtr tube and hoock complete all as specified and directed. Confirming to Cat part No ALD573 of jaguar completed all as specified |
| 26 | S&F PVC connections 15 mm dia and 450 mm long with brass nuts complete all as specified and as directed. |
| 27 | S&F in SS Cockroach trap for floor trap incl fixed in complete all as specified and as directed. |
| 28 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and as directed. |
| 29 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 50 mm bore complete all as specified and as directed. |
| 30 | S&F in repair PVC (SWR) bends any radius 75mm bore complete all as specified and as directed. |
| 31 | S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint fixed to wall complete all as specified and as directed. |
| 32 | S&F in repair PVC (SWR) bends any radius 110mm bore complete all as specified and as directed. |
| 33 | M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth by cleaning, sand papering,brushing etc , filling in cavities and cracks etc with approved filler and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and as directed. |
| 34 | M & L for preparation of old decorated surface on walls and applying two coat of acrylic weather proof paint (Exterior grade) over a coat of primer complete all as specified and directed. |
| 35 | M & L existing treatment on old walls and applying two coat of plastic emulsion paint complete all as specified and directed. |
| 36 | M & L existing treatment on old ceiling and applying two coat of plastic emulsion paint complete all as specified and directed. |
| 37 | S&F in repair towel rack stainless steel 600 mm long shelf with lower hangers complete all as specified and as directed and approved by Engneer -in Charge CAT NO CAN-CHR-1181S (Make : Jaquar) |
| 38 | S&F in repair chromium plated shower roses 200x200 mm size with or without swivel joints of standard size including fixing to 15mm steel pipe or union complete all as specified directed and approved by Engneer -in Charge Cat No-276017 (Make : Jaquar). |
| 39 | S & F of Corner Glass Shelf (with Bracket) CAT NO ACN-1173 JAGUAR or equivalent incl all fittings and accessories complete all as specified and as directed. |
| 40 | S&F Soap dish of chromium plated or stainless steel fixed to wall with chromium plated brass screws complete all as specified and as directed. CAT NOCAN11151N. (Make : Jaquar) |
| 41 | S&F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and as directed. Cat No-CAN-CHR-1151N (Make : Jaquar) |
| 42 | S & F in repair Stainless steel curtain rods 25mm dia fancy type with required supports, and open/end brackets complete all as specified and directed. |
| 43 | S&F Factory made single extruded WPC (Wood Polymer Co mposite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprisingof virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp-ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance tospread of flame of Class A category withproperty of being termite/borer proof,water/ moisture proof and fire retardant complete all as specified and as directed. |
| 44 | S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgen polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. |
| 45 | S&F Brass, sliding door bolt 300 mm with sand or die-cast brass has staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and as directed. |
| 46 | S&F brass Handle fabricated type polished of Size 150 mm complete all as specified and as directed. |
| 47 | S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed. |
| 48 | Demolition of pre-cast concrete block masonry built in cement mortar of any description in any position complete all as specified and as directed. |
| 49 | M&L for precast cement concrete block masonry with solid blocks of PCC (1:3:6) (using 20mm graded stone aggregate in the proportion as directed) exc 10cm in width and set and jointed in Cement Mortar (1:6) complete all as specified and directed. |
| 50 | M&L Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finishcomplete all as specified and as directed. |
| 51 | S&F in PVC Wire wire cloth 0.50 mm nominal dia of wire and average width of aperture 1.18 mm, complete all as specified and as directed. |
| 52 | S & F powder coated anodised Aluminium alloy sections sliding windows with frames 92 X29.6 X1.10mm , 3 track sliding shutters duly fitted with neoprene beading, glazing clips, two shutters tinted glass panes 4.80 mm nominal thickness one shutter with stainless steel wire cloth 0.45mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed. Note : Making all edges i.e. cill and jamb good by cement mortar 1:3 |
| 53 | S&F powder coated aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified and as directed. |
| 54 | S&F in repair brass 4 Levers Mortice lock, vertical type size 100 mm, complete all as specified and as directed. |
| 55 | M&L in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and as directed. |
| 56 | Dismantling plain or corrugated steel sheeting any gauge thickness including Nanital or similar pattern roof covering complete all as specified and as directed. |
| 57 | S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 58 | S&F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 59 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 60 | M&L for false ceiling work of galvenised MS ceiling grid system 'UNLOCK\\" comprising of main runner 38mmx24mmx0.35mm cross tee 38mmx24mmx0.25mm and GI suspenders 4mm dia fixed to ceiling with and including supply and fixing water proof laminated gypsum ceiling board of size 600x600x 8 mm thick complete all as specified and directed and fixed as per manufacturers instructions complete all as specified and directed. |
| 61 | Supply and Fix in repairs, seamless ceiling with using 12mm thick, factory made gypsum fiber board, fixed on GI frame work for seamless ceiling suitable for suspended system with and including applying two coats of oil bound distemper over a coat of primer to give even and smooth finish without showing any joints complete all as specified and directed. |
| 62 | S & F Vitreous China Urinal, Half stall type,white with Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) including PVC connection , bottle trap 32mm complete all as specified and directed. |
| 63 | S&F Smart Mirror Size 750 mm dia glass thickness 5mm thick light changing mode warm light, cool white,natural white complete all as specified and as directed. |
| 64 | S&Fsingal piece slim concealed cistern body with installation kit (without Flush Complete approved and directed. Cart Part No- JCS-4200 (Make : Jaquar) |
| 65 | S&F Rimless Blind Installation Wall Hung WC with UF soft slime seat cover Hinges Accessories set size 345 x495 x 365 mm approved and directed. Cart Part No- ARS-WHT39953BIUFSM (Make : Jaquar) |
| 66 | Providing and fixing wooden glazed Sliding door of Size 1.00 x 2.00 mtr (Approx) with shutter made of 30 mm thick block board single-piece sheet both faces laminated with approved quality paper based decorative laminate fixed with approved adhesive including edge lipping with matching laminate, the shutter shall be provided with glazing panel fitted with 5 mm thick frosted glass fixed with wooden beading, the door shall be hung on heavy duty alluminium sliding track /channel of approved make with nylon/ball bearing rollers,stoppers and all necessary fittingsfor smooth operation providing and fixing 18 mm thick plywood pelmet laminated on exposed face with matching paper-based laminate to conceal the sliding arrangement including 200 mm long concealed handle of approved make,screws fasteners,hardware and complete all as specified and as directed. |
| 67 | M&L for 18/19 Block boards, grade 2 quality, interior grade, commercial type , fixed with screws to timber frame work as in cub board ,WHB Counter, shutters/selves and the like, etc.complete all as specified and directed. |
| 68 | M&L teak wood ply 3 mm thick finished to block board etc including prelamination of surfaces and providing decorative polish (Melamine/PU/Synthetic deco polish) complete all as specified and directed. |
| 69 | M&L for preparing old painted surfaces of steel and iron surfaces over 10 cm in width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and as directed. |
| 70 | Dismantling Prelaminated particle boarding, any description, fixed in any position with screws complete all as specified and as directed. |
| 71 | S&F WPC (Wood Polymer Composite) solid wall lining consisting of 9 mm thick any coulour and any pattern WPC sheet inclusive of solvent cement and fixing at site on WPC frame complete all as specified and as directed. |
| 72 | M&LSurface Preparation of wall must be thoroughly cleaned, free of dust, grease etc and washed well with water. The surface to be checked for cracks, hollowness and loose plastered areas etc if any. All loose plaster and cracks larger than 10 mm width to be repaired with polymer modified mortar using Dr. Fixit Pidicrete URP. The cracks up to 5 mm to be treated with Dr. Fixit Crack-X Paste and the larger ones up to 10 mm with Dr. Fixit Crack-X Shrinkfree. and priming After the proper surface preparation and curing of repaired areas wash the surface well and maintaining it in saturated surface dry condition proceed for priming using Dr. Fixit Primeseal diluted in 2:1 ratio with water (2 parts Primeseal diluted with 1 part water). Maintain the spreading rate of 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs and coating Brush apply one coats of Dr. Fixit Raincoat Waterproof Coating without any dilution Maintain the spreading rate of 3.5-4.0 sq mtr per litre / coat application to achieve about 120-130 microns DFT. The second coat of Dr. Fixit Raincoat Classic Topcoat to be apply with interval of 6-8 hours without any dilution. Maintain the spreading rate of 7-8 sq mtr per litre / coat application to achieve about 50-60 microns DFT. |
| 73 | M&L for complete removal of existing roof treatment incl brushing and applying neat cement slurry with 3 Kg/Sqm of cement complete all as specified and directed. |
| 74 | M&L for averaging 25mm thick PCC of type B-1, 1:2:4 (20mm graded stone aggregate) for padding incl water proofing compund complete all as specified and directed. |
| 75 | M&L Rendering 10 mm thick of CM 1:4 on concrete roof surfaces is to be finished even and smooth without using extra cement with mixing water proofing compound @3% by weight. complete all as specified and as directed. |
| 76 | M&L for water proofing treatment to roof surfaces as under :-Surface Preparation Roof substrate must be washed with water to remove all dirt, dust, chalking and waste products.Stagnant water due to undulation in the roof surface should be marked and repaired with PMM. All joints / corners / penetration points, rainwater outlets, marble / tile strip joints should be grouted with PMM.WATERPROOFING APPLICATION All joints / corners / penetration points, rainwater outlets, marble / tile strip joints and parapet wall and floor junction joint (corner rounding) over the length shall be treated prior to all application of Dr. Fixit Roofseal Classic by reinforcing minimum layer of 50 – 100 mm width, with 45gsm glass fibre mesh cut to size, embedded in between the two coats of Dr. Fixit Roofseal Classic to provide additional strength to the treatment. Allow the coating to dry for 4- 6 hrs. before application of second. Apply a coat of Dr. Fixit Roofseal Classic (diluted with water in the ratio 2:1) as Self-Priming 9 - 10 Sq.mtr / litre. Allow coating to dry for 4 hours prior to applying first coat & second coat. pply two coats of Dr. Fixit Roofseal Classic @ 2.0 - 2.2 Sq.mtr / litre / coat, with the same application coverage. Application direction of second coat should be perpendicular to that of the first coat without water dilution to deliver a DFT of 450– 500 micron. |
| 77 | S&F 30 mm thick flush shutters,solid core construction, with block board core and plywood face panels, commercial type on both sides covered with decorative face veneer with lipping/frame to match on one sides complete all as specified and as directed. |
| 78 | S&F Powder coated Aluminium frame for doors, windows, ventilators and partition with or more rebates incl. jointing cleat for fixing etc. complete all as specified and as directed. |
| 79 | S&F sheet glass 4 mm thick ordinary quality and glazing with oil putty or rubber beads complete all as specified and as directed. |
| 80 | M& L 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 81 | M&L Durastone / Endura heavy duty vitrified tiles not less than 12mm thick (square/rectangular) area of each tile n.exc 0.36 sqm, in in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 82 | Dismantilng wrought iron or mild steel work of any description not otherwise provided for all as specifed and directed. |
| 83 | M&L for framed brackets of angles or tees with web and franges cut to shape, drilled and countersunk for screw incl bending and welding angles, as necessary gusset plate plates, reviting etc 10 kg each brackets confirming to Fe 290 Gde E-165. |
| 84 | M& L of Preparation of old decorated surfaces and applying one coat of Terracota Paint on Floor and Wall Surfaces complete as all specified and directed. |
| 85 | M/L for two coat of enamel paint( Ist quality) over a coat of red oxide primer on new steel surface including preparation of surface over 10Cm width or girth complete all as specified and as directed. |
| 86 | M&L for PCC (1:4:8) type D-2, (using 40 mm graded stone aggregate), as in sub base for floor, finished even and rough complete all as specified and directed. |
| 87 | M&L for Form work to sides and soffits of floor or roof RCC beam sides of lintel beam flat rough finish surfaces to receive the plaster, complete all as specified and as directed. |
| 88 | M&L for Form work to soffits of suspended slabs such as roof slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), rough finish surfaces complete all as specified and as directed. |
| 89 | M&L for Form work to edges of concrete flats, floor and roofs not exceeding 20cm wide (horizontal or sloping), rough finish surfaces complete all as specified and as directed. |
| 90 | M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in roof, landings, balconies, canopies and in shelves etc; complete all as specified and as directed. |
| 91 | M&L for mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns , beam and slab hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed. |
| 92 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders → |
| 93 | Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc complete all as specified and as directed. |
| 94 | Taking down main switches from DBs with sheet metal enclosure 08/04 way SPN/TPN DBs etc complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 95 | Taking down main switches from DBs with sheet metal enclosure 08/04 way SPN/TPN DBs etc complete all as specified and as directed. Please Enable Macros to View BoQ information |