Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I |
| 2 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 3 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 4 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing random rubble stone masonry in C.M. (1:4) in foundation and plinth with hammer dressed stone of less than 0.03 M³ in volume and clean coarse sand of F.M. 2 to 2.5 including cost of screening, raking out joints to 20 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 6 | Providing designation 75-B, one BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 7 | Providing designation 75B brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I. |
| 8 | Providing designation 75 A brick work in C.M. (1:3) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints,costs of screening,materials, scaffolding, raking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 9 | Providing designation 125 mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 11 | Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 13 | Suspended floors, roofs, landings, balconies and access platform |
| 14 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Weathered shade, Chhajjas, corbels etc., including edges |
| 16 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). |
| 17 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 18 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 20 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size) |
| 21 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 22 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 23 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note:-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately.) |
| 24 | All works up to plinth level |
| 25 | All works above plinth level upto floor V level |
| 26 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 27 | Extra for R.C.C./B.M.C./R.M.C. work above floor V level for each four floors or part thereof. |
| 28 | Providing Tor steel reinforcement for 8mm. dia rods as per approved -do- TMT Fe 500 (Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)) |
| 29 | Providing Tor steel reinforcement of 10mm.,12mm & 16 mm. dia bars as per approved design and drawing -do- -do- |
| 30 | (a) 10 mm (TMT coil Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 31 | (b) 12 mm (TMT coil Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 32 | (c) 16 mm (TMT coil Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 33 | Providing Tor steel reinforcement of 20mm, 25mm., 28mm, 32mm dia bars as per approved design and drawing -do- -do- |
| 34 | (a) 20/25 mm dia TMT bar Fe 500 {Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 35 | Supplying,fitting and fixing collapisable gate of approved size and make properly fabricated with vertical double channels 20X10X2 mm. at 100mm. Centres and braced with M.S. flat diagonals 20 x 3mm, with top and bottom rails of T. iron 40x40x6mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 36 | Providing & fixing FAN HOOK of 16 mm dia M.S. bar, 1 M long bent to required size and shape, placed in position and fluid in the R.C.C. slab-beam at the time of casting all complete as per building specification and direction of E/I. |
| 37 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 38 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core blended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I |
| 39 | Supplying,fixing and fixing godrej mortice lock in flush door shutters with 4mm. transparent plastic sheet push plate 125x250mm. size on both sides all complete as per direction of E/I. |
| 40 | Providing 12 mm thick waterproof cement plaster (1:3) with clean coarse sand of F.M. including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I |
| 41 | Providing 12mm. cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 42 | Providing 25mm. thick water proof cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 43 | Providing 6mm. Thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 44 | Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I. |
| 45 | Providing 1.5 mm cement punning including curing with all leads & lifts of water, as per building specification and direction of E/I |
| 46 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I. |
| 47 | Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I. |
| 48 | Providing two coats of SYNTHETIC ENAMEL PAINT of approved shade and make over new WOODEN surface including cleaning the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification dirction of E/I. |
| 49 | Providing French spirit polishing over new wooden surface to give desired texture and gloss with approved make and shade of ready mixed French polish including cleaning the surface after removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 50 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 51 | For fixed portion |
| 52 | Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 53 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 54 | Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 55 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 56 | Pre-laminated particle board with decorative lamination on both sides |
| 57 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 58 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 59 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- charge. |
| 60 | With stainless steel cover plate minimum 1.25 mm thickness |
| 61 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 62 | Upto 5 mm depth and 5 mm width |
| 63 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 64 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 65 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 66 | 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 67 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying |
| 68 | a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
| 69 | (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 70 | The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 71 | (WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.) |
| 72 | Water proofing for Old and New Roof Slab: Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a) Surface preparation: Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equivalent. Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm × 150 mm fillet of mortar (Cement: sand – 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concrete beam slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b) 1st Coat: Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet up to 600 mm by brush or roller. After 1st coat of application, 45 gsm Fibre glass cloth to lay when the first layer is still green. 1st coat @1.5 Kg/Sqmt/coat. (c) 2nd Coat: Apply 2nd coat of two component acrylic modified ready to use cementitious material right angle to 1st coat over glass fibre. 2nd coat @0.7 Kg/Sqmt/coat. After 3 days, ponding test 48 hrs. (d) Protection of treated surface with PCC: Provide 25/50mm PCC M-20 (1:1.5:3) with slope 1:120, 2m×2m panels, 6mm gap, IS 2645 integral waterproofing. (e) Groove filling with Polysulphide Sealant (Paid separately). (Terrace) |
| 73 | Providing and applying Thermoflex P-111 /Sika Coolcoat or any other Equivalent compound on Roofs of Slab as per following procedure:- (i)Surface preparation:-Surface of Roof slab should be cleaned with wire brush. Dust particle should be removed and surface should be washed with high water pressure and it should be get dried.(ii)Primer Coat:-Thermoflex P-111 should be diluted with potable water in 1:1 ratio and this Solution should be applied on cleaned and Dry surface with soft brush/ roller . (iii)1st Coat o P-111: After 3 hours of primer coat First coat of P-111 (without any dilution)should be applied with soft brush/ roller .(iv)when the 1st coat is partially dry an acrylic fiber mesh 80 GSM mat should be laid over it and pressed with roller.(v)Second /Final Coat :-2nd coat of P-111 (without any dilution)should be applied after 3 hours of 1st coat of application.It should be allowed to dry for 4 hours. Note :-There should not be any water contact on treated surface till 24 hours of final completion of treatment. (Toilet) |
| 74 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 75 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 76 | Granite stone slab of all colour and texture except black,Cherry/Ruby red |
| 77 | Area of slab upto 0.50 sqm |
| 78 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 79 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 80 | Epoxy |
| 81 | Replacing sand stone slabs in roofing, laid in cement mortar 1:4 (1 cement : 4 coarse sand), including necessary repairs and cement pointing with same mortar complete, including disposal of rubbish to dumping ground, all complete as per direction of Engineer-in-Charge. |
| 82 | Red/ white sand stone slabs 30 to 50 mm thick |
| 83 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 84 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 85 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 86 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 87 | 2.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 88 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 89 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 90 | Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. |
| 91 | 25 mm diameter. |
| 92 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 93 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 94 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 95 | Providing and laying vitrified Cool Roof tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 154557-2007 / 15013006, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Its solar reflective Index ( SRI ) value should be above 78. complete. Size of Tile 300x300 mm x10 mm thick. |
| 96 | Providing and fixing at all height wall panelling with phenol bonded Bamboo Mat board conforming to IS:13958-1994 including providing and fixing to frame work made of 50 mm x 50 mm hard wood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge. |
| 97 | 12 mm thickness |
| 98 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 99 | In 75x75 mm deep chase |
| 100 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 101 | Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : |
| 102 | 15 mm wide and 15 mm deep groove |
| 103 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, settingblocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter forholding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified.The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 170251. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range oftesting limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml |
| 104 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 105 | Granite work |
| 106 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete. |
| 107 | Finishing walls with textured exterior paint of required shade : |
| 108 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 109 | CARRAIGE OF MATERIALS |
| 110 | LOCAL SAND , LEAD - 2P+1K= 3 KM. |
| 111 | COARSE SAND , LEAD - 9P+1K= 10 KM. |
| 112 | STONE CHIPS , LEAD - 21P+1K= 22 KM. |
| 113 | BOULDER, LEAD - 4P+1K= 5 KM. |
| 114 | BRICKS , LEAD- 7P+1K= 8 KM. |
| 115 | Earth carrige upto 5.0 Km |
| 116 | W I R I N G |
| 117 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 118 | Group B |
| 119 | Group C |
| 120 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 121 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 122 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 123 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 124 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 125 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 126 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 127 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 128 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 129 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 130 | 20 mm |
| 131 | 25 mm |
| 132 | 32 mm |
| 133 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 134 | 5/6 amps switch |
| 135 | 3 pin 5/6 amp socket outlet |
| 136 | Telephone socket outlet |
| 137 | TV antenna socket outlet |
| 138 | Bell push |
| 139 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 140 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 141 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 142 | 1 or 2 Module (75mmX75mm) |
| 143 | 3 Module (100mmX75mm) |
| 144 | 4 Module (125mmX75mm) |
| 145 | 6 Module (200mmX75mm) |
| 146 | 8 Module (125mmX125mm) |
| 147 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 148 | 1 or 2 Module |
| 149 | 3 Module |
| 150 | 4 Module |
| 151 | 6 Module |
| 152 | 8 Module |
| 153 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 154 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 155 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 156 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 157 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 158 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 159 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 160 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 161 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 162 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 163 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 164 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 165 | 225 mm sweep |
| 166 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 167 | Group C |
| 168 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 169 | 125 A,36KA,FPMCCB |
| 170 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator |
| 171 | 8 way , Double door |
| 172 | 12 way , Double door |
| 173 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 174 | 4 way (4 + 12), Double door |
| 175 | 6 way (4 + 18), Single door |
| 176 | 8 way (4 + 24), Single door |
| 177 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 178 | 4 way (4 + 12), Double door |
| 179 | 8 way (4 + 24), Double door |
| 180 | 12 way (4 + 36), Double door |
| 181 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 182 | Single pole |
| 183 | Double pole |
| 184 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 185 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 186 | 40 amps |
| 187 | 63 amps |
| 188 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 189 | 100 A |
| 190 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 191 | 40 amps |
| 192 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 193 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 194 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 195 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 196 | CABLE TRAY |
| 197 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 198 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 199 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 200 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required |
| 201 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 202 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 203 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 204 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 205 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 206 | E A R T H I N G |
| 207 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 208 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 209 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 210 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 211 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 212 | L I G H T N I N G C O N D U C T O R |
| 213 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 214 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductorcomplete as required.(For horizontal run) |
| 215 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductorcomplete as required.(For vertical run) |
| 216 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 217 | WIRING FOR LOW VOLTAGE OUTLETS |
| 218 | Supply, Drawing and Testing of 4 pair ,100 Ohm, 24 AWG UTP Cat 6 Cable as per latest amendments of TIA / EIA 568 B.2 specifications for Data / Telephone points in existing MS /PVC conduits including making connections to Information outlets and patch panels with ferruling at both ends for identification with necessary tools for punching ,stripping crimping and testing as required 1 Run Cable |
| 219 | FIRE ALARM NETWORK |
| 220 | INTELLIGENT FIRE ALARM SYSTEM |
| 221 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications |
| 222 | Two Loop Panel. |
| 223 | Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 224 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 225 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 226 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 227 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 228 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 229 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 230 | PUBLIC ADDRESS SYSTEM (For Conference Hall, Offices Areas) |
| 231 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 232 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 233 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 234 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 235 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. |
| 236 | 200/150 MM DIA. DEEP BOREWELL |
| 237 | 200/150 mm dia Deep borewell : Cost of drilling 200 mm X 165 mm X 125m deep brewell in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH Rig machine, all complete including supplying all all materials, tools drilling rig, Air compressure and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicle up to the site. |
| 238 | (a) From 0.00 M to 50.00 M below G.L |
| 239 | (b) From 51.00 M to 125.00 M below G.L |
| 240 | (c) From 125.00 M to 200.00 M |
| 241 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 242 | 200mm Nominal size dia. |
| 243 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 244 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm Dia. |
| 245 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. |
| 246 | Supplying 100mm dia. Submersible pump sets confirming to IS 8034 and motor cvonfirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft ant polypropylene/ norylimpeller. Motor suitable for working on 415 V+10%, 3PH, 50 HZ, AC supply with cable guard, thurst carbon/ fibre bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined no return valve shall be provided with pump. 3 m submersible copper conductor cable in single/ double run and nylon rope as required length shall be provided with each pump. |
| 247 | Submersible pump set 100mm dia (with polypropylene/ Noryl Impeller) |
| 248 | Supplying and fitting of standared make starter pannel board with arrangement of all necessory protection ,including all taxes , royalty etc all complete job as per direction of E/I 5 HP TO 10 HP |
| 249 | Supplying ,fitting & fixing & connecting 3 core 4 sqmm flat copper submerssible cable of Finolex / Hevels make including all taxes ,royalty etc all complete job as per direction of E/I |
| 250 | Supplying and laying /lowering of GI pipe of 50 mm dia including of required fittings solvent etc complete job as per direction of E/I |
| 251 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : |
| 252 | Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern. |
| 253 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 254 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 255 | Providing and fixing , kitchen sink without drain boad 610 X 510 mm bowl depth 200 mm C.I. Brackets, C.P. Brass chain with rubber plug, 40mm C.P brass waste and 40 mm C.P. Brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 256 | Providing and fixing white vitreous water closet squatting pan (indian type ) |
| 257 | Long pattern W.C. Pan of size 580 mm |
| 258 | Providing and fixing white vitreous china pedestal type (European type / wash down type ) waster closet pan. |
| 259 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 260 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 261 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 262 | Providing and fixing P.V.C. waste pipe for wash basin including P.V.C. waste fittings complete. |
| 263 | Semi rigid pipe |
| 264 | 40 mm dia |
| 265 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 266 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 267 | Providing and fixing toilet paper holder : |
| 268 | C.P. brass |
| 269 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 270 | 100 mm inlet and 100 mm outlet |
| 271 | Sand cast iron S&S as per IS - 3989 |
| 272 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 273 | 100 mm dia |
| 274 | 75 mm dia |
| 275 | 50 mm dia |
| 276 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 277 | C.P.V.C. PIPES |
| 278 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 279 | Internal work |
| 280 | 20 mm nominal outer dia Pipes |
| 281 | 25 mm nominal outer dia Pipes |
| 282 | 40 mm nominal outer dia Pipes |
| 283 | 50 mm nominal outer dia Pipes |
| 284 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge |
| 285 | Concealed work, including cutting chases and making good the walls etc. |
| 286 | 20 mm nominal outer dia Pipes |
| 287 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 288 | External work |
| 289 | 25 mm nominal outer dia Pipes |
| 290 | 40 mm nominal outer dia Pipes |
| 291 | 50 mm nominal outer dia Pipes |
| 292 | BRASS FITTINGS |
| 293 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 294 | 20 mm dia nominal bore |
| 295 | 25 mm dia nominal bore |
| 296 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : |
| 297 | 25 mm dia nominal bore |
| 298 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 299 | 30 cm length |
| 300 | 15 mm nominal bore |
| 301 | C.P. BRASS FITTINGS |
| 302 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 303 | 15 mm nominal bore |
| 304 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 305 | 15 mm nominal bore |
| 306 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 307 | 15 mm nominal bore |
| 308 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 309 | 15mm nominal bore |
| 310 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 311 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 312 | With common burnt clay F.P.S. (non modular) bricks |
| 313 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 314 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
| 315 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 316 | Sevices and Accessories on Building |
| 317 | Fire Fighting |
| 318 | Fire Hydrant System |
| 319 | Supply, Installation, Testing & Commissioning of: Single headed, SS/ Gun Metal ISI marked oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63mm dia instantaneous type female outlet complete with Gun Metal cap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type 'A') |
| 320 | Supply, Installation, Testing & Commissioning of: First-Aid Fire Hose Reel wall mounting swinging type complete with drum, bracket, ball valve and 20mm dia.x 30M long high pressure Hose Reel tubing as per IS:444 with Gun Metal shut-off nozzle having 5mm dia. orifice. The Hose Reel shall strictly confirm to IS : 884-1985 |
| 321 | Supply, Installation, Testing & Commissioning of: Non-percolating flexible hose (RRL type-'A') ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneous type SS/ Gun Metal 63 mm dia. IS marked Male and female couplings (IS:903) bound and riveted to hose pipe with Gun Metal rivets and 1.5 mm Gun Metal wire |
| 322 | Supply, Installation, Testing & Commissioning of Gun Metal Fire Brigade connection (Suction collecting head) consisting of 63 mm dia instantaneous type male coupling with built-in check valves and 150 mm dia. flanged outlet complete with bolts, nuts and rubber insertions as required as per IS:904-1983 |
| 323 | Two Way |
| 324 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) heavy class including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. |
| 325 | 150 mm dia IS 1239 |
| 326 | 100 mm dia IS 1239 |
| 327 | 80 mm dia IS 1239 |
| 328 | 50 mm dia IS 1239 |
| 329 | Supply, Installation, Testing & Commissioning of slim seal dual type non-return valves (PN 1.6) complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes. |
| 330 | 150 mm dia |
| 331 | Providing and fixing Slim seal Butterfly valves (PN 1.6) complete with matching flanges rubber insertion, nuts. bolts and washer etc. of following sizes |
| 332 | 150 mm dia nominal bore |
| 333 | FIRE PUMPS, VALVES & ACCESSORIES |
| 334 | Supply, Installation, Testing & Commissioning of cubical type wall mounted Fire Pump Control Panel (For Terrace Pump at Roof) with One Fully Automatic DOL Starter suitable for 900 LPM Pump Motor with over load relay, timer push buttons and Auto/Manual selector switch. |
| 335 | NON SCHEDULE ITEMS |
| 336 | Supply & Installation of RJ-45 Information outlets Jack ABS FR grade with spring loaded collapsible shutters in jack recess suitable for Cat 6 application with terminator caps for tooless termination . |
| 337 | Single Outlet |
| 338 | Supply , Installation and Testing of 4 pair , 100 Ohm, 24 AWG , Cat 6 UTP, flexible , Double ended Patch Cords along with 2 No of RJ 45 connectors with strain relief transparent boots as per TIA /EIA 568 B.2-1 Specifications. |
| 339 | 1 Mtr/3 ft |
| 340 | SITC of 10/100 MBPS Unmanaged Switch |
| 341 | 24 Port |
| 342 | Supply , Installation, Testing and Comissioning of Rack mounted 19\\", Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps. |
| 343 | 24 Ports Patch Panel |
| 344 | Supply , Installation, Testing and Comissioning of Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, one Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable . |
| 345 | 12U(44 mm ) wall mounted |
| 346 | 27U(44 mm ) |
| 347 | CCTV & SURVEILLANCE NETWORK |
| 348 | 2 Megapixel Fixed Lens Camera IR Dome Type: 1/2.8\\"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8mm Fixed lens, 0.028 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, IK10, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, video tampering, UL, CE, FCC certified. |
| 349 | 2 Megapixel Fixed Lens Camera IR Bullet Type: 1/2.8\\"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. |
| 350 | NVR 64 Channel: Connect Up to 16 IP Cameras, Dual OS, Up to 8 Megapixels Resolution, HDMI output with 4k output and VGA output with 2MP Output , Support H.265,H.264, MJPEG, Incoming Bandwidth 160 Mbps, 4 SATA Hard Disks, ANR Technology, 2 SATA interfaces for 2 HDDs and capacity of each HDD upto 6TB, 2 USB at least 1 × USB with 3.0, Serial interface:1 RS-485, 1 RS-232, Alarm I/O 16/4, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. |
| 351 | NVR 64 Channel: Connect Up to 16 IP Cameras, Dual OS, Up to 8 Megapixels Resolution, HDMI output with 4k output and VGA output with 2MP Output , Support H.265,H.264, MJPEG, Incoming Bandwidth 160 Mbps, 4 SATA Hard Disks, ANR Technology, 2 SATA interfaces for 2 HDDs and capacity of each HDD upto 6TB, 2 USB at least 1 × USB with 3.0, Serial interface:1 RS-485, 1 RS-232, Alarm I/O 16/4, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. |
| 352 | 8 Port Network Switch POE: 16 × PoE ports, 1 × RJ45 port, and 1 × SFP fiber optical port, IEEE 802.3at/af standard |
| 353 | 16 Port Network Switch Gigabit POE: 16 × gigabit PoE ports, 1 × gigabit RJ45 port, and 1 × gigabit SFP fiber optical port, IEEE 802.3at/af standard |
| 354 | CAT 6 Connector |
| 355 | Hard Disk 6 TB |
| 356 | Suplly & installation of Computer system as required |
| 357 | Installation/labour charges |
| 358 | Supply, Drawing and Testing of 4 pair ,100 Ohm, 24 AWG UTP Cat 6 Cable as per latest amendments of TIA / EIA 568 B.2 specifications for Data / Telephone points in existing MS /PVC conduits including making connections to Information outlets and patch panels with ferruling at both ends for identification with necessary tools for punching ,stripping crimping and testing as required |
| 359 | Supply and laying of HDMI Cabel |
| 360 | Supply and Laying of RIGID PVC Medium Duty Conduits ISI marked conduits complete with accessories such as bends, junction boxes, pull boxes etc., in recess or on surface including cutting chases in the walls/floors and making good the same complete as required. |
| 361 | 32 mm dia |
| 362 | 25 mm dia |
| 363 | INTERNAL LIGHTING FIXTURES |
| 364 | Providing of IP20 LED batten type light fixture made from CRCA sheet steel housing suitable for moutning LED tube system (integral driver), Power Consumption of 18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K & 6000°K.. |
| 365 | Providing of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. Power Consumption of ≤ 15W / 18W with ~ 1100 / 1250 lumens, System Lumen efficacy of 70 lm / watt output suitable to replace 1x18W / 2x18W / 2x 26W CFL Downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintaned. CCT 3000°K , 4000°K & 6000°K. Fixture shall be CE compliance. Note:- fixture Wattages are |
| 366 | Provide & Fixing of IP66 LED Midbay light with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and High Performance electronic driver ensure Zero Maintenance with 4KV High Surge Protection. Power Consumption of ≤ 70W-100W with ~ 9000-10000 lumens, System Lumen efficacy of 130 lm / watt output , life time of 50000 Burning Hours with 70% of intial Lumen maintaned. CCT 3000°K , 4000°K & 6000°K. Fixture shall be CE compliance. |
| 367 | Provide of Aesthetically Designed linear LED mirror light with a high output PMMA Diffuser for glare free output including making connection testing etc. as required Dimension-300mm |
| 368 | Provide of energy efficient / energy saving direct fit (Retrofit) Inverter LED Bulb . |
| 369 | 12 Watt LED LAMPS |
| 370 | Provide of Heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required. 300 mm Sweep 9 900 RPM) |
| 371 | Provide & Fixing of capacitor start, wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. |
| 372 | 400 mm sweep( oscillating type) |
| 373 | MV CABLES & TERMINATION |
| 374 | Supply,Laying/drawing of XLPE insulated & sheathed cable of 1.1 kV grade with Copper/ Aluminium conductor of approved makeon wall / Cable Tray with GI Saddles ,making necessary connections including testing etc. as required |
| 375 | 50.0 Sq.mm 3.5 core Armoured Al. Cable |
| 376 | 70.0 Sq.mm 3.5 core Armoured Al. Cable |
| 377 | 120.0 Sq.mm 3.5 core Armoured Al. Cable |
| 378 | 4.00 Sq.mm 4.0 core armoured Al. Cable |
| 379 | 10.00 Sq.mm 4.0 core armoured Al. Cable |
| 380 | 16.00 Sq.mm 4.0 core armoured Al. Cable |
| 381 | 10.00 Sq.mm 4.0 core Unarmoured Al. Cable |
| 382 | 16.00 Sq.mm 4.0 core unarmoured Al. Cable |
| 383 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. |
| 384 | 4 Sq.mm 4.0 core armoured Copper. Cable |
| 385 | 6 Sq.mm 4.0 core armoured Copper. Cable |
| 386 | 10 Sq.mm 4.0 core armoured Copper. Cable |
| 387 | 16 Sq.mm 4.0 core armoured Copper. Cable |
| 388 | CABLE TERMINATION |
| 389 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Al.Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. |
| 390 | 50.0 Sq.mm 3.5 core Armoured Al. Cable |
| 391 | 70.0 Sq.mm 3.5 core Armoured Al. Cable |
| 392 | 120.0 Sq.mm 3.5 core Armoured Al. Cable |
| 393 | 4.00 Sq.mm 4.0 core armoured Al. Cable |
| 394 | 10.00 Sq.mm 4.0 core armoured Al. Cable |
| 395 | 16.00 Sq.mm 4.0 core armoured Al. Cable |
| 396 | 10.00 Sq.mm 4.0 core Unarmoured Al. Cable |
| 397 | 16.00 Sq.mm 4.0 core unarmoured Al. Cable |
| 398 | 4 Sq.mm 4.0 core armoured Copper. Cable |
| 399 | 6 Sq.mm 4.0 core armoured Copper. Cable |
| 400 | 10 Sq.mm 4.0 core armoured Copper. Cable |
| 401 | 16 Sq.mm 4.0 core armoured Copper. Cable |
| 402 | Supply, Installation, Testing & Commissioning of LT Panel of cold rolled sheet metal construction, floor mounting, free standing, totally enclosed, dust and vermin proof conforming to IP42 degree of enclosure protection with base channel . The panel shall be as per IEC-61439 Type Tasted Assembly type panel. |
| 403 | SITC of cubical panel made out of CRCA sheet, required hardware, duly painted by either two coats of zinc/ red oxide primer followed by two coats of synthetic enamel paint or powder coating in grey or required shade after rinsing . The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . 3 mm thick sheet for gland. Side walls and cable alley compartments having bolted type doors. double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof with not less than IP-42 (For Indoor Type) Protection. |
| 404 | Note: Panel Shall be Floor Mounted . Panel cable Entry & Exit from Bottom . MCCB are T/M, O/L.S/C, Ics=100%Icu |
| 405 | Note :- Panel shall be made according to panel sld. |
| 406 | INCOMER |
| 407 | MCCB 400Amp FP 36 KA ,T/M, with ROM & Spredders, 1No. |
| 408 | Indicating Lights(Phase-R,Y,B,Contactor Open,Close) 5No. |
| 409 | 6 amps Protective SP MCB’s , 4 Nos. |
| 410 | OUTGOING |
| 411 | 160Amp FP MCCB, 25 KA ,T/M, with ROM & Spredders, 2No. |
| 412 | 63A. FP, MCCB, 10kA - 5 Nos |
| 413 | 40A. FP, MCCB, 10kA - 2 Nos |
| 414 | Bus Bars |
| 415 | 630amps ,TPN,Electrolytic high conductivity Aluminium busbar with colour coded heat shrinkable insulating sleeves. |
| 416 | Miscellaneous |
| 417 | Missll.( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, PVC Channel , MCB Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) |
| 418 | Design, manufacture, supply, installation, testing & commissioning of the following cubicle type weather proof(IP-67), dead front, sheet steel, wall/floor mounted control panels, including anchoring into the wall, wiring terminating from bottom into MCB & earthing, in each panel shall be provided by the electrical contractor. |
| 419 | Note: Panel Shall be Floor Mounted . Panel cable Entry & Exit from Bottom . MCCB are T/M, O/L.S/C, Ics=100%Icu |
| 420 | Note :- Panel shall be made according to panel sld. |
| 421 | INCOMER |
| 422 | 40A. FP, MCCB,16kA - 1 Nos |
| 423 | 40A. FP,300 mA - 1 Nos |
| 424 | Timer |
| 425 | OUTGOING |
| 426 | 40A. FP, MCCB,16kA - 1 Nos |
| 427 | PANELS FOR PUMPS |
| 428 | Design, manufacture, supply, installation, testing & commissioning of the following cubicle type weather proof(IP-67), dead front, sheet steel, wall/floor mounted control panels, including anchoring into the wall, wiring terminating from bottom into MCB & earthing, in each panel shall be provided by the electrical contractor. |
| 429 | All wiring & copper earthing of motors from panel shall be included. |
| 430 | The panel shall be include the following components & accessories. |
| 431 | MCB as per the ratings given bellow, suitable for motor duty and able to withstand fault level of 20KA. |
| 432 | DOL / SD starter as per HP rating |
| 433 | Terminal block for power distribution as required. |
| 434 | Contactor, overload relay with built in single phasing protection (only for DOL & S/D starter) |
| 435 | Phase indicating lights & indicating light for 'ON'/ OFF status. |
| 436 | Digital voltmeter & digital ammeter with selector switches. |
| 437 | Time delay relay for delayed automatic restart of motor. |
| 438 | Wiring for microswitch for stoping the fan at the time of fire |
| 439 | Remote start & stop facilities to be provided for each panel |
| 440 | The number of starter shall be as follow HP rating:- |
| 441 | 1 HP starter for Booster Pump (Three Phase ) |
| 442 | FAÇADE LIGHTING |
| 443 | Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. |
| 444 | Supplying, installation, Testing & Commissioning of of following capacity atfull load (Unity Power Factor) at operating temperature 0 to 40 deg C,Relative humidity 0 to 95%, Online double conversion true sine waveUninterrupted hot swappable (allow for the replacement or addition ofbattery modules without shutting down the entire system) modular PowerSupply (UPS) system with N+1 modules (N denotes total number of moduelsrequird for rated capacity). The UPS shall include a Rectifier, inverter,battery bank suitable for 30 minutes back up (Battery VAH capacity shall notbe less than 1600 VAH per KVA of UPS rating per Hour backup time) on fullload (Battery shall be VRLA, SMF in ABS Container) and Static Bypassswitch alongwith provision for manual bypass, suitable isolation transformerfor additional protection against neutral faults etc. UPS shall have inbuiltphase sequence correction. The UPS systems offered are to be of the latesttechnology with Digital Control Microprocessor based for reliable operationusing Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier &inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design,manufacturing and inspection process should confirm to the relevant Internationalstandards such as IEC/EN/VDE. The operating efficiency of theUPS systems shall be >96% while operating on battery mode and deliveringquality power to the 100% non-linear loads. Current total harmoniceffect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC (inductor (L) and a capacitor (C)) filters shall be included in UPS cost),extreme power factor kit to be included to limit the input power factor (PF) to0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall bekva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7leading power factor loads. UPS shall be suitable for incoming supply AC :3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt,50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output.Non condensing, noise level less than 60db at 1 meter distance, protections:Input Under voltage over voltage, abnormal out voltage, battery overcharging, output over current, short circuit protection, battery deepdischarge protection, 10KV surge. UPS must comply with low voltageelectromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 PartI and Part 2, it shall be a Voltage and Frequency Independent (VFI)-typeUPS. Communication RS232/RS485/SNMP port open protocol for BMSintegration, all hardware & software for iOT Communication as per approvedby Engineering in charge. Required battery racks and interconnectingcopper conductor cables of suitable size and connectors and all requiredaccoseries are inclusive of the cost). This system must provide a means forlogging and alarming of all monitored points plus email notification. Forcedair-cooling with integral inbuilt fans with redundancy (if one fan fail UPSshould be able to handle at least 80% of the load, Noise Level 65 DB at 1meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS:16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch ormore LC Display / LED ) to display : a) Input: Voltage, current, Frequency. b)Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current |
| 445 | d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage.f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (OnLCD/LED): UPS should capture and display up to 3000 events like: Overtemperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit /Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data:No. of power failures / Transfers to Bypass / Total Running time, etc. i) MainsMode of Operation /Battery Mode of Operation / Bypass feeding the load /UPS Fault /Battery charging and discharging, overload, battery voltage andbattery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPSOverload, Fault, Shutdown, Input Over, Under Voltage, Output Over, UnderVoltage, Battery Over, Under Voltage, Over Load and short circuit, OverTemperature. The UPS should have QR code which should containdrawing, test report OEM manual,Geo- Tag of manufacturing location etc. |
| 446 | 30KVA (Each Power module shall be < 10 KVA) |
| 447 | PASSENGER ELEVATOR |
| 448 | Design, Fabrication, Supply, Installation, Testing & Commissioning of Electric Traction Type fully automatic Machine room less (MRL) Heavy Duty Passenger Elevator having SS Enclosure (Grade 304) with AC variable voltage & variable frequency drive unit suitable for operation on 415 +/- 10 % V, 3 Phase, 50 Hz. AC supply, having speed of 1.5 MPS, power operated SS center opening type car & landing doors, electro-magnetic brake system, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, emergency light, intercom suitable for hook up to Facility's EPABX, infrared red sensing door protection for full height (min 2100mm height) & mechanical safety by pressure sensor, reverse phase relay on controller, fire man's switch at ground floor, digital car positions indicator in car with up / down direction indications, light fixtures, ventilation fan, landing sill, main beam in shaft for machine, pit ladder, provision of lighting in elevator shaft etc. complete with all accessories serving different floors in the lift shaft alongwith Automatic Rescue Device. as per RDSO Specifications |
| 449 | i) Elevator Type - Passenger |
| 450 | ii) Stops and Openings- 1 No |
| 451 | iii)Aproximate Travel- 8.4 meters |
| 452 | iv) Travel Speed- 1.0 / 1.1 mps |
| 453 | SOALR PHOTOVOLTAIC POWER PLANT |
| 454 | Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 500 Wp or above, manufactured in India,conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolarPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak wattcapacity, which should not be less than 90% at the end of 10 years and 80% at theend of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 VAC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate ACPower with efficiency not less than 97%, total harmonic distortion less than 3% andsuitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust thevoltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection andtermination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPEinsulated copper conductor 1.1 kV grade armoured power and control cablesbetween solar modules, main power cable to grid supply PCU unit along withsupplying & fixing of necessary channel/conduit lugs and other accessories etc. asrequired. |
| 455 | EV CHARGING STATION |
| 456 | Supplying Installation, Testing and Commissioning of EV charging station As per specifications and in Compliance to relevant IS codes etc. |
| 457 | Light EV AC Charger (Mode-3) Power : 7 kW, Input power supply: 1phase 230 +10% Volt, output supply: 230 Volt AC, Frequency:50 Hz +/-3%, Operational temprature range : -25 to 55 degree C (outdoor), -5 to 55 degree C(Indoor)., RH upto 95%, Charging Device as per IS-17017-22-1 EV-EVSE Communication: as per relevent IS Codes, Bluetooth Low Energy, one Charge Point Plug/ Socket as per IS-60309 and IS-17017-2, Vehicle Inlet/ Connector As per EV manufacturer, suitable for 2 Wheelers and 4 wheelers.Indoor use: at least IP41; Outdoor use: at least IP44. Mechanical Strength :protection of the external enclosure against mechanical impact shall be IK08 according to IEC 62262.O/L,S/C protection. Insulation Resistance > 1 M Ω. Cable Length: 7.5 m. RCD having a rated residual operating current not exceeding 30 mA; Seprate RCD for multiple outputs. Telecommunication port of the EV supply equipment according to IS 13252 (Part 1) : 2010. OCPP(Open charge point protocol) 1.6J upgradble to ocpp 2.0. Device Should follow 17017 series of IS codes in general and the installation of the system shall comply with relevent IS Codes. |
| 458 | (For Internal Drainage Works) |
| 459 | Providing and fixing uPVC RWP pipes (IS: 13592 Class B Heavy Type) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with rubber ring/solvent cement joints,clamps including cutting chase or holes in walls and floors and making good where required.(for rain water pipe inside the building) |
| 460 | 110 mm dia. |
| 461 | 75 mm dia. |
| 462 | Providing and fixing uPVC soil, waste and vent pipe (IS: 13592 Class B) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with solvent cement/rubber rings, including pipe support/angle/channels from ceiling, including cutting chase or holes in walls and floors and making good where required. |
| 463 | 40 mm dia |
| 464 | 50 mm dia |
| 465 | 75 mm dia |
| 466 | 110 mm dia |
| 467 | Providing and laying cement concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm and down gauge) 75 mm in bed and all round C.I. pipes / UPVC pipes. |
| 468 | 150/100/75/50/40/32 mm dia soil & waste pipes under floor including shuttering and centering. |
| 469 | Providing & fixing in position SWR PVC P\\", S\\",Nanhi trap of self cleaning design of following sizes for the embedded areas. Making proper connection with , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. |
| 470 | 110 mm inlet and 110 mm outlet. (Floor traps, P- type only) |
| 471 | 110 mm inlet and 75 mm outlet (Nanhi Trap) |
| 472 | Providing and fixing Cast bronze chrome plated grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar. |
| 473 | 125 mm dia |
| 474 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size). |
| 475 | Fixing in position special angle supports for hanging/Vertical pipes fittings with fastners.Complete as per requirement. |
| 476 | Cutting holes in walls and core cutting in R.C.C. floors/slab and roofs/beams(100mm to 300mm thick R.C.C) for passing drainage/water supply pipe etc. and repairing the hole after insertion of drainage/water supply pipes etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), water proofing chemical, grouting etc. including finishing complete so as to make it leak proof. |
| 477 | For 75mm dia |
| 478 | For 110mm dia |
| 479 | For 160mm dia |
| 480 | Providing & fixing brass/ gun metal lever operated ball valve. Tested to a pressure of 15 Kg / Sqcm. Including flanges/union, nuts, bolts, washer etc. Complete as required. |
| 481 | 20 mm dia |
| 482 | 25 mm dia |
| 483 | 40 mm dia |
| 484 | 50 mm dia |
| 485 | Supply, Installation, Testing & Commissioning of: SS/ Gun Metal 63mm dia short size branch pipes with 20 mm dia nozzle with 63mm instantaneous coupling ISI marked (IS: 903) |
| 486 | Providing & fixing standard fireman's axe with heavy insulated rubber handle. |
| 487 | Supply, Installation, Testing & Commissioning of:M.S. hose door fabricated from 16g M.S. sheet with full glass door and locking arrangement, suitable to accommodate 1 Hydrant landing valve, 1fire hose reel, 2 nos.15m long 63mmdia hose,1-branch pipe. The door shall be painted with one coat of primer and finished stove enamelled \\"Fire Red\\", \\"Fire Hose\\" written on front including suitably mounted on a raised masonry platform as required. (Approx. size 1.2m x .6m x 2.1m ) |
| 488 | Supply, Installation, Testing & Commissioning of: Air cushion tank (air-vessel) 250 mm dia. x 1.0 M high with dished top, made of minimum 6 mm thick M.S. pipe/plate complete with 25 mm dia. Brass Air Valve (Ball valve, pressure gauge type), 25 mm dia. Stop with brass stop cock, nipple, tees, elbow, pipe and all accessories as required incl. fixing brackets. |
| 489 | PORTABLE CHEMICAL FIRE EXTINGUISHERS |
| 490 | Supply and fixing of ISI marked ( IS : 15683 ) ABC (Dry Powder) fire extinguishers cap 10 kg (9Kg) in seamless HP steel cylinders ISI marked and approved by CCE Nagpur fitted with pressure indicating gauge, internal tube squeeze level type valves fully charged with ABC powder and pressurized by Nitrogen complete in all respects including wall suspension bracket. |
| 491 | Supply and fixing of ISI marked (IS:2878) Portable fire Extinguisher, Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1m long & complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling ratio of not more than 0.667and wall suspension bracket. |
| 492 | Capacity 4.5 Kg |
| 493 | Add GST 18 % |
| 494 | Add Labour cess 1% Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail