Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKSClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness as per technical clause 201 of MORT&H specifications In area of Light Jungle (By Manual Means) |
| 2 | Dismantling concrete Cement concrete plain1:2:4 mix |
| 3 | Scraping Cement plaster |
| 4 | Removing doors and windows together with the dismantling of walls Doors |
| 5 | Removing doors and windows together with the dismantling of walls Windows |
| 6 | Cement concrete 1:4:8 with brick balast 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 7 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorptions less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. Size 600x600 mm |
| 8 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. |
| 9 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure |
| 10 | 12.5 mm thick cement plaster 1:5 |
| 11 | 20mm thick cement plaster 1:5 in two coat work |
| 12 | Plastering on underside of ceiling 10mm thick cement plaster 1:4 |
| 13 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 14 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 15 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 16 | Repairs to plaster in patches of Area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 Metres lead With cement mortar 1:4 (1 cement:4 sand) Taking area 2.5 sqm |
| 17 | Providing & fixing 32mm thick factory made Internal solid door shutter consisting of solid core particle board of 24mm thickness, lipped with 15mm (5mm x 3) thick x 32mm width on one stiles & top rails & 10mm (5mm x 2) thick x 32mm width on the other stiles & Bottom rails. The panel laminated with 4mm thick termite proof, water proof & fire resistant PVC sheet both side using rubber adhesive on flush door & solvent Cement adhesive on the PVC lipping etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in- charge. |
| 18 | Chowkats of commercial hard wood such as Hollock confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops, bolts for hold fasts etc, complete fixed in position Double Rebate (60mm x 150mm) |
| 19 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 20 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 21 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 22 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 23 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded). |
| 24 | Flush/Ruled/Struck or weathered pointing on tile brick work with cement mortar 1:3 (1 cement :3 fine sand). |
| 25 | Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of Elastobar and Zycoprime/Equivalent after application of Zycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brushable. Apply the paste on surface with brush. Leave the surace for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementatios membrane using mixture of 1 Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed. |
| 26 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 27 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 28 | Providing & fixing 6\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 29 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size ofdoor 851mm to 1000mm) |
| 30 | Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) 30 mm thick |
| 31 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN) |
| 32 | PUBLIC HEALTH WORKSScreed of 50mm thick cement concrete 1:8:16 with stone aggregates to be laid below the topping using mechanical mixer for mixing of material |
| 33 | Cement concrete 1:2:4 With stone ballast or shingle mixing by manual means |
| 34 | Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B- Class including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. 15mm i/d |
| 35 | 20mm i/d |
| 36 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 15mm i/d G.I. Union |
| 37 | 20mm i/d G.I. Union |
| 38 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. 20mm i/d Gun Metal peet valve heavy pattern. |
| 39 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. Through wall 22.86 cm thick |
| 40 | Excavation manually in trenches with straight or open cuttingin built up street/lanes having wall to wall width upto 3 mtr for sewers and manholes to full depth as shown in drawings, including shoring, dressing to corect sections and dewatering of rain water, provision for diversion for traffic, protection of exisiting services i.e. telephone cables, electric lines, water supply lines and gas lines etc night signals, profiles, Pegs, Sight rails, boning rods, fixing and maintenance ofcaution boards, fencing, refilling trenches, watering, dressings and restoration of surface to original level and removal of Surplus Spoils from the Site of Works upto 15 mtr, for all Works other than connections to complete in all respects, For depth not exceeding 2 m. below Ground level All classes of soil except rocky |
| 41 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 160mm o/d pipe |
| 42 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming toI.S.I complete as per standard design. 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 43 | Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda Sewer connections upto 300 mm id |
| 44 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 45 | Extra for providing and fixing C.P. Brass short flush bend 32mm instead of PVC short bend. |
| 46 | Extra for providing and fixing 10 litres capacity Chinaware low level flushing cistern with PVC internal fitting, instead of 10 litres capacity PVC flushing cistern. |
| 47 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. With C.P. Brass nut |
| 48 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 49 | Providing and fixing Stainless steel health faucet complete in all respect. |
| 50 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 550 mm x 400 mm x 815 mm |
| 51 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 52 | Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge) |
| 53 | Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge) |
| 54 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. Vitreous chinaware standard white pedestal for wash hand basin. |
| 55 | Providing and fixing in position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 56 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 57 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 1500mmx600mm or any other size |
| 58 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 59 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in- charge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long |
| 60 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete inall respect. |
| 61 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body foam flow without flange |
| 62 | C.P. brass Bib cock foam flow without flange |
| 63 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Concealed stop cock with flange. |
| 64 | C.P.brass 15mm Angle valve withoutflange |
| 65 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 66 | Providing & fixing in position C.P. copper tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. copper tube connection of size 15 mm x 600 mm with C.P. Brass nut |
| 67 | Single Socket Type B Providing and fixing in position single socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 110mm o/d SWR UPVC pipe lines laid complete |
| 68 | 90mm o/d SWR UPVC pipe lines laid complete |
| 69 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) 110mm o/d |
| 70 | 90mm o/d |
| 71 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 72 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d pipesDoor Cap |
| 73 | Single Tee With Door |
| 74 | Door Elbow 90 Degree (All side socketed) |
| 75 | Vent Cowls |
| 76 | Single Y-Junction |
| 77 | For 90mm o/d pipes Door Cap |
| 78 | Single Tee With Door |
| 79 | Door elbow 90 degree (all side socket) |
| 80 | Vent Cowls |
| 81 | Single Y-Junction |
| 82 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in- charge) in PVC Water storage tanks complete in all respect. G.I. tank nipple 25mm i/d |
| 83 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 84 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 85 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 86 | ELECTRICAL WORKSSURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½\\" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- Wiring fan point (Without fan box) |
| 87 | Wiring light point |
| 88 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring call-bell point |
| 89 | Wiring 6Amp. wall socket point |
| 90 | Wiring 16/20Amp. power plug control point |
| 91 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing thesurface):- Supply and Erection of Computer Point with 8 Module Sheet Metal Box and 8 Module cover plate with 2 Nos. 6A Switch Modular and 3 Nos. 6A Socket (Two Module) covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface). Complete in all respect as per satisfaction of Engineer in Charge at site. |
| 92 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Supply and Erection of Air Conditioner Point with 32A DP Switch, 2 Module Cover Plate with 16A Socket covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface). Complete in all respect as per satisfaction of Engineer in Charge at site. |
| 93 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring Telephone socket point RJ11 (one module) |
| 94 | Wiring Networking socket point RJ45 (one module) |
| 95 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (Un-sheathed) |
| 96 | Overall size 2.5sq.mm (Un-sheathed) |
| 97 | Overall size 4sq.mm (Un-sheathed) |
| 98 | Overall size 6sq.mm (Un-sheathed) |
| 99 | XLPE INSULATED LT CABLES: XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 10sq.mm (2Core) Un-armoured(Loose) |
| 100 | Overall size 16sq.mm (4Core) Un-armoured(Loose) |
| 101 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.) |
| 102 | HEAVY GAUGE WELDED CONDUITPIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD GeneralSpecifications:- Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. |
| 103 | PVC, HDPE PIPES & PVC FLEXIBLEPIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD GeneralSpecifications:- Heavy Gauge PVC Conduit Pipe 25mm dia.(Flushed) |
| 104 | Heavy Gauge PVC Conduit Pipe 32mm dia.(Flushed) |
| 105 | Heavy Gauge PVC Conduit Pipe 40mm dia.(Flushed) |
| 106 | PVC, HDPE PIPES & PVC FLEXIBLEPIPES: Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- PVC Flexible Pipe 25mm dia. |
| 107 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size ofthimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 108 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 109 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 110 | HEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles andbonding to existing earth etc:- SP&N Double Door Distribution Board 12way each |
| 111 | TP&N Horizontal Double Door DistributionBoard 4 way each |
| 112 | SHEET METAL BUS BAR CHAMBERS(COPPER STRIPS): Supply and erection of sheet metal bus- bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus- bar strips of suitable length and cross- sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site: Bus Bar Chamber 63amp., 415volts Overall Dimensions (300mm x 345mm x 120mm) nominal |
| 113 | MCCB's (MOULDED CASE CIRCUITBREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 63/80/100amp., 415volts,≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 114 | MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be S type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 115 | Supply and erection of Copper Chemical Earthing 3 meter long earthing rod typically has a copper-bonded steel rod with a minimum 250-micron copper coating, a diameter ranging from 14mm to 50mm or more, and a high tensile strength of around 90,000 psi. For installation, it is placed in an augured hole, surrounded by earth enhancing compound, and often interconnected with other electrodes using a 25x2mm copper strip or 8mm solid copper conductor, buried at least 500mm deep complete in all respect as per satisfaction of engineer in charge at site. |
| 116 | Supply and Erection of 3 Star Rating Ceiling fan Suitable size 48” (1200mm) Full Aluminium Body, 3 Nos. of Blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delevery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minute and 5 Nos. of speed. The approximate weight of the product should be 4kg and 180gms (without packing) or higher. The product should have a manufacturer's guarantee/ warranty of minimum 2 years. The product should be complete in all respects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fans having connection with PVC insulated PVC sheathed tow single core copper conductor (FR) cable 0.75 SQ MM complete in all respects as desired by the Engineer in charge of work at site.TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB 160amp.) |
| 117 | Supply and Erection of Heavy Duty Exhaust Fan Suitable size 12” (300mm) including Louver shutter, connection & testing complete in all respects as desired by the Engineer in charge of work at site. Exhaust Fan, Blade Sweep : 300 mm (12”), Type of motor : Permanent capacitor induction motor, C75 Rated Voltage : 230 volts, 50 Hz, AC. single Phase, Test voltage : 230 volts, 50 Hz, .AC. I Phase, Frequency : 50 Hz., Capacitor rating : 1.0 F, 400V, 50 Hz, AC., Rated watts at full (load) speed & at 230V. : 27 watts., Current in amps at full speed & at 230 V. : 0.12 Amps., Power factor : 0.9 min., Rated full speed & at 230 V : 1310 rpm., Rated air delivery at 230 V : 800 M3/hr, Rated Service value : 30 m3/hr/watt, No. of blades leaves : Five, Type of blade leaf : Plastic (PP), No of running positions : One position, Class of Insulation : Class “E”, Type of bearings : Oil impregnated self aligned bush bearings. |
| 118 | Supply and Erection of 15 Watt Surface mounted LED edge lit slim downlight with a durable PDC aluminum body and frosted diffuser, it ensures uniform illumination and asleek, modern aesthetic for various applications. Efficacy: 100 Im/Wcomplete in all respects as desired by the Engineer in charge of work at site. The certification and specification of LED Fitting's should be as approved by O/o Advisor (Technical, Govt of Punjab Vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB |
| 119 | Supply and Erection of 40 Watt 1X4 LED Linear Lights have the flexibility and freedom to design the lighting of your workplace any way you deem fit. Linear lights are also available in highefficiency (upto 140 lm/W), UGR & up-down versions complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical, Govt of Punjab Vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 120 | Supply and Erection of 100 Watt LED Flood Light fitting (including LED driver) with pressure die cast aluminium housing with control gear (IP 66 protection), THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fittings should be as approved by O/o Advisor (Technical, Govt of Punjab Vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB |
| 121 | Providing Networking SystemSupply, Installation, Testing & Commissioning of 16-Port Gigabit Unmanaged Switch,10/100/1000Mbps Gigibit Ethernet,16,76W ,External Input 54V 3.7A(200) Input 54V 2.4A(130W)Input 54V 1.66A(90W) ,Metal Desktop, wall & rack mount ,Power, Link/Activity, Fanless, Yes, Yes, Yes,4K, 1MB ,32Gbps ,IEEE 802.3az complaint ,2,088,514 hours, Yes, Yes , 1:3:5:7:8:10:12:15 Weighted Fair Queue (WFQ) Input 54V 1.66A (90W) External ,90W ,0 dBA (Fanless) ,0° to 40°C (32° to 104°F) ,Class A ,11.26 x 4.02 x 1.06 in ,0.88 kg (1.94 lb) .47CFR FCC Part 15, SubpartB, Class A ICES-003:2016 Issue 6, Class A ANSI C63.4:2014,55032:2012+AC:2013, Class A EN 55024:2010 EN 61000-3-2:2014, Class A EN 61000-3-3:2013 ,AS/NZS CISPR 32:2015, Class A, VCCI-CISPR 32:2016, Class A,CNS 13438 ,CB. IE 60950-1:2005(ed.2) + A1:2009 + A2:2013 ,UL/cUL Listed; UL60950-1, 2nd Ed. 2014; CAN/CSA C22.2 No. 60950-1-07, 2nd Ed. 2014,EN 60950-1: 2006+ A11:2009+A1:2010 12:2011 + A2:2013, AS/NZS 60950.1:2015, Lifetime Hardware Warranty ,90 Day's Free remote configuration support Replacement with new box product. |
| 122 | SITC of Token Calling Display System having screen size 4 inches, Voice calling with Bell System, complete key pad Etc, calling display up to 60 meter cable (15 meter length included), serial communication design, Text Color Red Display Shape Rectangle, Power W, Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital, Cash counter, Tehsil, Courts etc, Warranty 1 Year,220 VAC Operating Voltage Character Capacity 3 Character, Power Consumption, Rectangular Metal body. |
| 123 | SITC of CAT 6, 24 Port Fully loaded Patch Panel, Rack Mountable for cable termination. |
| 124 | SITC of CAT 6 one Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps. |
| 125 | SITC of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps. |
| 126 | Supply & installation of 9U Wall mount 19\\" Rack with glass door,lock& key facility 400/450/500mm depth AC Fan having 10 No. mounting hardware, Cable entry/exit provision at top and bottom panel, ventilation slot on top, bottom and side pannels, comply IS standards of racks. |
| 127 | Supply & installation of 1KVA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller,overload protection, overcharding protection, 2 No. 12V 7Ah batteries, wide input range, fanless colling system, transfer time less than 8 ms, Audible Alarm etc. |
| 128 | Supply, Erection, Testing and Commissioning of 3 KVA Double Conversion Online UPS system including batteries 12V 65 ah Amp hrs. True online Pure Sine wave DSP Controlled online UPS with single phase AC input and single phase AC output with inbuilt Isolation transformer of same OEM make at Input Including installation & 2 years warranty. Along with battery rack interconnection cables & 5/7-meter DC wire from UPS to battery bank and other standard accessories of UPS & Battery Bank. UPS is with inbuilt Phase sequence correction & protection feature, TVSS & Cold start feature and emergency power off (EPO) feature & dust filters, manual & automatic bypass inbuilt and UPS should be capable for Parallel operation up to 4 same units with additional optional PRS kit. UPS Rating: KVA 3, Load Power Factor: PF 0.8, Efficiency: 0.9, Nominal DC Voltage: VDC 12Vx no of batteries 8, No of Batteries: 8, End Cell Voltage: 1.75x6: 10.5, DC Watts: = (KVA X 1000 XPF) / (Inv Eff X No. of batt) Watts, DC watts: UPS load DC wattage 444, Backup time: in mins 60, AH Offered: AH rating of SMF battery: 65AH, No of cells/Batteries: 1string of 8 no. of 65AH, Min VAH of bank for 60 min: 1 set of 8 no. of 12V-65AH 10080, Battery AH Wattage: 65AH battery gives Backup calculation: Backup Achieved in min= battery AH wattage x 60 Min/ UPS load DC watts: 33.14 min, Backup achieved more than 60 min backup achieved: on SMF battery bank with 10080VAH on 0.8LPF for 3KVA UPS. This 3kVA double-conversion on-line 2U rackmount UPS provides pure sine wave power to support critical electronics during power disruptions. The SRV comes with IEC 320 C20 input, 6x IEC320 C13 and 1x IEC 320C19 outlets. The On-Line UPS has a intelligent card slot for optional Network Management Card (AP9544, SRVSMB001, VGL9901I) that enables network-based UPS monitoring and management. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The Built-in automatic and manual bypass provide seamless power to the load even in the event of an internal detected fault or error in UPS. The SRV UPS is compatible with replacement battery cartridge APCRBCV202 The UPS is compatible with SRVRK1 rail kit sold separately. The UPS and the built-in lead-acid battery has a 2-year warranty. Ideal for small data centers, manufacturing facilities, computer rooms, network storage devices, telecommunication and health care IT complete in all respect as desired by the Engineer-in-charge of work at site. |
| 129 | COPPER CONDUCTOR CABLE FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulated with star separator, 4 pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E Standard left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge.CAT 6 LAN cable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail