| 1 | Dismantling AC Sheet Roofing without roof timbers including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309) |
| 2 | Dismantling Brick / Stone Masonry in cement mortar walls under 3m high including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications |
| 3 | Earth work excavation for foundation by manual means for RR/Brick and Other step type footings for Load bearing structures in all soils and sub-soil sand to full depth as may bedirected except inrock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10mts and initial lift of 2.00mts. and clearingand levelling the site, etc., complete complyingwith standard specification and as directed by thedepartmental officers |
| 4 | Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly)using 40 mmgauge hard broken jelly for flooring including laying,nsolidating, finishing, renderingthe top surface rough to receive the floor, curing, etc. complete multiplying with standard specificatio nand as directed by the departmental officers.The rate is inclusive of necessary plankingfor panelling wherever necessary and as directed by the departmental officers-Mixing by Manualmeans |
| 5 | Supplying, fabricating and placingin position MildSteel/ Ribbed Tor Steel reinforcement grills of all variety like HYSD/ CTD/ TMT and all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steelreinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 6 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, columnpedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10BG stiffened with welded mild steel angles of size25mmx25mmx3mm for boarding, laid with silver oakjoists of size10cmx5cm & 7.5cmx5cm as support runner ,vertical stiffener, side supportand Top Horizontal stiffener space data bout 60cmto90cm centre tocentreor at suitable intervals etc. complete in all floors complying with standard specifcation.(Payment for centering shall be given after the concrete is laid). |
| 7 | Supplyinganderectingsteelcenteringincludingnecessarysupports ForplanesurfacessuchasrectangularorsquareRCCcolumnsetc.whichrequireonly nominal struttingusing mildsteel sheetsmadeof10gaugethickweldedwithMSanglesize40mmx40mmx5mmandsupportedbySteelAdjustableTelescopicPropsofSize2mx2m(expandableupto3.60m)madewith outer steel pipewith dia 50mm(3.60mmthick) and inner steel pipewithdia 40mm(2.90mmthick).etc..complete inall floors complyingwithstandard specifcation. Steel Adjustable telescopic propsshall be rovided asdirectedby thedepartmentalOfficers. (Payment for centeringshall be given after the concrete is laid). |
| 8 | Supplying and erecting centering for plane surfaces such as RCC Floor/ Roof Beam,Lintels,Cantilever Beams, Bed Blocksetc.. with necessary supports and strutting upto3.60m height inall floors with all cross bracings using M S Sheetsmade of 10 gauge thick welded with MS angle ofSize 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x2m(expandableupto3.60m) and Silver Oak Joists of Size10x5cm spaced at50cm to 60cmc/c andsupported by Steel Adjustable Telescopic Props of Size2mx2m (expandable upto3.60m) made withoutersteelpipewithdia50mm(3.60mmthick)andinnersteelpipewithdia40mm(2.90mmthick)Space dat not more than 50to60cmc/c,etc complete complying with standard specifications. Steeladjustable span and Steel Adjustable telescopic props shall be provided as directed by thedepartmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 9 | Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordancewithIS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC itemsofworkswith minimumcement content of 350 kglm3 andmaximumwater cement ratio of 0.50, including admixture(plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard settingof concrete, improveworkabilitywithout impairingstrengthanddurabilitywithabout (5.0 Cu.m)7730kg.of20mmmachinecrushedstone jellyandwithabout (3.3Cu.m)5156kg. of10 12mmmachinecrushedstonejellyandwithabout(4.79cu.m’)7670kg.ofcrushedstonesand,but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and alsoincludinglaying,vibratingwithmechanicalvibrators,finishing,curing,etc.andprovidingfixtureslike fanclamps intheRCCfloor/ roof slabswherevernecessarywithout claimingextra, etc., completecomplying with standard specificationandasdirected bythe departmental officers.Thecoar seand fineaggregates tobeused should complywith the requirements of ISStandards. (No separate payment will be made by the Department for the excess usage of materials). |
| 10 | a) Upto basement level |
| 11 | b) For Ground Floor |
| 12 | Brickwork in following Cement Mortar using best quality Burnt Clay Brick of size 9”x43/8”x23/4” with class designation of 7.5 conforming to IS1077-1992 for foundation and basementincluding Cost of Mortar Plasticizer curing,etc., complete complying with standard specification andasdirected by the departmental officers. Brickwork shall bedoneasper IS2212-1991adoptingEnglish Bond generally.other type of bondshall bedoneasdirectedby theExecutiveEngineer incharge |
| 13 | a) Upto Basement Level |
| 14 | B)GrounD Floor |
| 15 | Supply and filling in foundation and basement with Well Gravel in layers of not more than15cm.thickwell rammed watered and compactedwith surface vibrator, watered and consolidated etc.complete complying with standard specification and as directed by the departmental officers. |
| 16 | Plastering the surface of walls with CementMortar1:3 (One cement andThreeplasteringsand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kgof cement used,curingetc., complete complyingwithstandardspecificationandasdirectedby the departmentalofficers |
| 17 | Plastering with Cement Mortar 1:5 (OnecementandFivePlasteringsand), 12mm thick in allfloors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. completecomplying with standard specification and as directed by the departmental officers. |
| 18 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gaugeinpures laked lime(nocrushedstonesandtobeused) to the proportion of brick jellyto lime being32:12.5 by volume and laid over the RCC roof slab in asingle layer of requiredslope and finished bybeating the concrete with wooden beaters of approved pattern, keeping the surface constantly wetbysprinkling limejaggery water,etc.,complete as per standard specification and as directed bythedeparmental officers. |
| 19 | Finishing the top of roof with one course of machine pressed tiles of following size ofapproved quality set in CementMortar1:3 (OneCement andThreeCrushedstoneSand) 12mmthick mixed with water proofing compound conformingtoISSat2%byweight ofcementusedandthe joints pointedneatly to full depth of tiles with the same cement mortar mixed with red oxide andwaterproofing compound including curingetc., complete complying with standards pecification andas directed by the departmental officers |
| 20 | Paving the floor with best quality vitrified Tiles of following size and variety conforming IS15622 with water absorbtion less than 0.08%of approved colour and shade laid over cementmortar bed of 20mm thick incement mortar1:3 (one cement and three crushed stones and) withrequired Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standardspecification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works - Vitrified Tiles of Size : Variety : Stainfree Nano polished Vertified tiles 600 x 600 x 8mm |
| 21 | Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thickof approved quality and colour laid in accordancewith IS1443 in Cement Mortar 1:3 (OneCement and Three crushed stones and), with required Cement Slurryand Mortar Plasticizer, 20mmthick and pointed with white cement mixed with colouring pig ment at the rate of 0.40Kg. /sq.m.,curing, etc., complete complying with standard specification andasdirectedby thedepartmentalofficers. ( The make and brando f thetiles should be got approved byExecutive Engineer be fore useon works) |
| 22 | Stainless Steel (SalemStainlessSteel) Door Frame-Box Section using Stainless Steel Platewith following thickness with the size of 100mmx 60mm with are bateof 30/35mm x15mm ononeside of the frame including supplying and fixingd ove tail splayed end stainless steel Hold fast etcincluding dismantling ,making necessary chipping and holes in RCC columns,walls with power drillsto the extent required ,including providing concrete 1:2:4 inside the box curing etc completecomplying withstandard specificationand as directedbythe departmental officers-SSDoor Framewith thickness of 1mm/1.60mm. |
| 23 | Solid Core Flush Shutters with teakply on both side with teak wook lipping alround 35mm thick, Labour wrought and put up in position Shutters for fully panelled doors internal five plywood panels including labour charges for fixing furniture fittings complying with standard drawings and standard specification. SOR PG 42 S N 121 |
| 24 | UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 25 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. |
| 26 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 27 | White washing two coats with freshly burnt white shell lime in all floors including cost of lime,blue powder fevicol typegum,brushes,scaffolding charges,etc.,complete complying with standardspecification and as directed. |
| 28 | Painting New Plastered Wall Surface with Two finishing coats of readymixed (Emulsion)of approved quality and colourover one coat priming coat inall floors including the costof primeretc., complete complying with standard specification and as directed by the departmentalofficers.(Themake, qualityandcolourof paint shouldbe gotapprovedbytheExecutiveEngineerbefore use on works.) |
| 29 | Painting wire on works suchas steel doors,windows, ventilators,windowbars, balustradesetc.,withThree coats of bestapprovedfirstquality and colourof synthetic enamel paint over theexisting red oxide priming coat in all floor excluding cost of priming coat etc., complete complyingwith standard specification and as directed by the departmental officers. (Themake, qualityandcolour of paint should be got approved by the Executive Engineer before use on works.) |
| 30 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall P ipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc.,andfixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatlyetc.,complete. Therateshall be inclusiveof castof removablecast iron grating. ThePVC pipe shall be fixed in wall with special typeof “U”clampat thecentre of thepipelineinadditiontothose for more than 3.0metre pipe length,etc.,complete complying with standard specification and as directed by the departmental officers |
| 31 | 110mm dia PVC Pipe for One Floor |
| 32 | Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigidpipe concealed in wall and ceiling with PVC accessoires inflush with wall with 3mm thick hylum sheet coverwith TW switch box and 5AFTswitch and making good of the concealed portion with suitable colour for PVC concealedlight /fan Point (for electronic regulator) (5 points per coil) |
| 33 | Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitablePVCrigid pipe concealed in wallandceiling with PVC accessoriesinflushwith wall with 150mmx100mmx 113mm TWswitchbox with 3mmthick hylem sheet cover for5A3pinnoninter lockingwall socket with 5Aflushtype switch with continuous earth wire connection of 1.5sq.mm copper wire and making goodof the concealed portion with suitable colour for concealed PVC plug point |
| 34 | Supply and fixing of single box type 4'40Wfluorescent fitting complete with copper chokeand condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting., |
| 35 | Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb ., |
| 36 | Supplyandfixingof1200mm(48\\")ACceilingfancompletewithsteppedelectronic300Wregulatorwith1meterdownrod on the existing clamp , |
| 37 | Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse uniT |
| 38 | Supplyand fixingof 20AFlush typeWall Socket32ADPMCBcompleteset forACPlug in flushwithwallwithearthconnection., |
| 39 | Supply and run of 4x6sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100Vgrade in 32mmdiaGIpipe (Class 'B') suitably bent at both ends with necessary angle iron up right and end supports for mains |
| 40 | Art Works and letter Writing of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors. Please Enable Macros to View BoQ information |