| Sl. No. | Item Description |
| 1 | Civil Work:Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. DSR 15.7.4 |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. :Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). DSR 15.2.2 |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. DSR 15.3 |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. :Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). DSR 15.2.1 |
| 5 | Earth work in excavation by Mechanical means ( Hydraulic excavator) manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and remming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within lead of 50m. All kind of soil. DSR 2.8.1 |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DSR 15.60 |
| 7 | Preparation of sub grade including trenching rough dressing of soil, final dressing of earth to give level and camber, watering, rolling with a road roller and compaction of bed complete in all respect to the entire satisfaction of Engineer in Charge. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) DSR 4.1.10 |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand). DSR 6.1.1 |
| 10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. DSR 2.25 |
| 11 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2 |
| 12 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) DSR 6.13.1 |
| 13 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level DSR 5.33.1 |
| 14 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level DSR 5.33.2 |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform DSR 5.9.3 |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ). DSR 5.9.4 |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR 5.9.5 |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, piers, abutments, pillars, posts and struts DSR 5.9.6 |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form work for : Edges of slabs and breaks in floors and walls Under 20 cm wide. DSR 5.9.16.1 |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.6 |
| 22 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22A.6 |
| 23 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.DSR 2.27 |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.DSR 8.31 |
| 25 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR 11.26.1 |
| 26 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. DSR 11.27 |
| 27 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite stone slab colour black, Cherry/Ruby red: Area of slab over 0.50 sqm DSR 8.2.2.2 |
| 28 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge: Granite work. DSR 8.3.2 |
| 29 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. DSR 8.5 |
| 30 | Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : With residual type petroleum bitumen of grade VG -10. DSR 12.15.1 |
| 31 | 10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar with bhusha @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow-dung) and covered with machine moulded tile bricks, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat With machine moulded common burnt clay F.P.S. (non modular) brick tiles of class designation 12.5, conforming to IS 2690. DSR 12.17.1 |
| 32 | Extra for every additional 1 cm thickness of mud phaska.. DSR 12.18 |
| 33 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase. DSR 12.21.1 |
| 34 | Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand): Stone ware spout. DSR 12.37.1 |
| 35 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) DSR 13.1.1 |
| 36 | 6 mm cement plaster of mix : 13.16.1 1:3 (1 cement : 3 fine sand). DSR 13.16.1 |
| 37 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand):Flush / Ruled/ Struck or weathered pointing DSR 13.31.1 |
| 38 | Finishing Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer. DSR 13.43.1 |
| 39 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.80 |
| 40 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification Two or more coats on new work. DSR 13.42.1 |
| 41 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).DSR 13.46.1 |
| 42 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. DSR 12.50 |
| 43 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete : 0.80 mm thick with zinc coating not less than 275 gm/m2. DSR 12.7.1 |
| 44 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion : Powder coated aluminium (minimum thickness of powder coating 50 micron). DSR 21.1.1.2 |
| 45 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron). DSR 21.1.2.2 |
| 46 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. DSR 9.20.1 |
| 47 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood. DSR 9.27.1.1.2 |
| 48 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing 30 mm thick pre laminated PVC door shutters DSR 9.120.2 |
| 49 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm). DSR 21.3.1 |
| 50 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm. DSR 9.96.1 |
| 51 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm. DSR 9.96.2 |
| 52 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm DSR 9.97.2 |
| 53 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm. DSR 9.97.4 |
| 54 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm. DSR 9.100.1 |
| 55 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm. DSR 9.100.2 |
| 56 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper. DSR 9.101.2 |
| 57 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete.DSR 9.84 |
| 58 | Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately). DSR 9.168 |
| 59 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. DSR 9.171 |
| 60 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete: 125 mm. DSR 9.165.1 |
| 61 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. DSR 10.25.2 |
| 62 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete DSR 10.2 |
| 63 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work DSR 13.61.1 |
| 64 | Credit of serviceable bricks |
| 65 | Credit of brick bat |
| 66 | Public Health WorkProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low levels white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS 7231 with all fitting and fixtures complete including cutting and marking good the wall and floors wherever required etc. complete in all respect. |
| 67 | W.C. pan with ISI marked white solid plastic seat and lid. |
| 68 | Providing and fixing in best Indian make C.P. jet complete in all respects. |
| 69 | Providing and fixing CP brass bib cock of approved quality conforming to IS:8931. 51 mm nominal bore. |
| 70 | Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm without white PVC automatic flushing cistern but with fitting, standard size C.P. brass flush pipe, speaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556 C.I. trap with outlet grating and other coupling in C.P brass including painting of fitting complete in all respect. |
| 71 | Single half stall urinal with 5 litrer PVC automatic flushing cistern |
| 72 | Providing and fixing white china ware star colour wash basin complete with CP central hol mixture Mak Nova of Equivalent as pers specification of EIC |
| 73 | Providing and fixing wash basin C.I brackets 15mm C.P. brass pillar taps 32mm C.P. brass waste of standard pattern, i/e painting of fitting and brackets, cutting and making good walls wherever require. |
| 74 | White Vitreous China wash basin size 630x450mm with a pair of 15 mm C.P. brass pillar taps. |
| 75 | Providing and fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore. |
| 76 | Providing and fixing best Indian make looking mirror 5mm thick including the cost of PVC beeding all around, water proof PVC sheet/6mm thick hard board fixied screws and cheats with CP brass screws & warsher complete |
| 77 | Providing and fixing plain bend of required degree100 mm dia Sand cast iron S&S as per IS - 1729 |
| 78 | Providing and fixing plain bend of required degree. 75 mm dia Sand cast iron S&S as per IS -1729 |
| 79 | Providing and fixing collar 100 mm Sand cast iron S&S as per IS - 1729 |
| 80 | Providing and fixing collar 75 mm Sand cast iron S&S as per IS - 1729 |
| 81 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS - 3989 |
| 82 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 20 mm dia nominal bore |
| 83 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 25 mm dia nominal bore |
| 84 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks |
| 85 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 86 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 87 | Providing and fixing 1HP monoblock pump set single phase 240 Volts including the cost of foundation, nuts and bolts complete in all respects make: Crompton/Servo/Kirloskar |
| 88 | Providing and fixing in position best Indian make ISI marked ball cock of 25mm wit brass rod, PVC ball complete in all respects. Make:Viking |
| 89 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal bore |
| 90 | 25 mm nominal bore |
| 91 | Providing and fixing best Indian make (to the approval of the EIC) gun metal ISI peat valve complete in all respect Make: Viking peat valve 20mm (NSI) |
| 92 | Peat Valve 25mm |
| 93 | Providing and fixing G.I Tank Nipple AVR make complete in all respect .Make:- SVW/Unik/AVR 20mm dia nominal bore |
| 94 | 25 mm dia nominal bore |
| 95 | Providing and fixing gun metal non- return valve of approved quality (screwed end 25 mm nominal bore Horizonta |
| 96 | Providing and fixing water meter cover 1’-6”x 1’-0” with frame made out of M.S sheet 18 gauge frame from angle 360mm x30mmx5mm with locking arrangement & painting complete in all respects |
| 97 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc, not exceeding 80 mm dia. |
| 98 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 99 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter |
| 100 | 200 mm diameter |
| 101 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe (C&D) |
| 102 | 200 mm diameter S.W. pipe |
| 103 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 104 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 105 | Making connection of drain or sewer line with existing manhole and making good the walls, floors with C.C. (1:2:4) mix. For pipes 100 to 250 mm diameter |
| 106 | For pipes 300 to 450 mm diameter |
| 107 | Providing and fixing sides supports (CP grab rail heavy duty of size 50mm dia suitable length as per requirements for differently blind persorns complete in all respect |
| 108 | Providing and fixing un-plasticized PVC connection pipe with brass unions. 30 cm length 15 mm nominal bore complete in all respect. |
| 109 | Providing and fixing of of PVC waste pipe 32mm dia |
| 110 | Providing and fixing CP extension nipples of size 15mm and 25mm of reputed Make complete in all respects. |
| 111 | Providing and fixing soil, waste and vent pipes100 mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 112 | Providing and fixing soil, waste and vent pipes100 mm dia Sand cast iron S&S pipe as per IS: 1729 75 mm diameter Sand cast iron S&S pipe as per IS: 1729 |
| 113 | Providing and fixing of IRC Jali 1”x1” angle 25x5 mm with locking arrangement and primer coat complete as per satisfaction of EIC. |
| 114 | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete i/c cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests |
| 115 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fitting with flexible pipe complete in all respect. |
| 116 | 32 mm dia |
| 117 | Providing and fixing of Marble partition for half stall urinal complete in all respect |
| 118 | Providing and fixing toilet paper holder : C.P. brass |
| 119 | Providing and fixing CP brass Soap Dish Holder with fitting arrangement complete in all respect. |
| 120 | Providing and fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore. |
| 121 | Brick work with common clay F.P.S (non modular) bricks of class designation 75 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 122 | CARRIAGE OF MATERIALS By Mechanical Transport including loading,unloading and stacking Lime, moorum, building rubbish |
| 123 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore |
| 124 | 20 mm dia nominal vbore |
| 125 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter 100 mm |
| 126 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter 75 mm |
| 127 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board: 610x460 mm bowl depth 200 mm |
| 128 | Providing and fixing of CP Cup Heavy duty complete in all respect |
| 129 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 130 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in- charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 131 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in- charge Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 132 | Providing & fixing of RCC MH cover & frame HD-20 of size 450x450 mm for chamber as per DSR |
| 133 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type: With common burnt clay F.P.S. (non modular) bricks of class designation 75 |
| 134 | Providing and fixing of boards indicating toilets Gender friendly complete in all respect as per satisfaction of EIC |
| 135 | Writing of awareness slogan regarding Swachh Bharat Abhiyan including preparing the surface with base putty furnishing etc., complete in all respects |
| 136 | Providing and fixing of plastic made items Heavy duty for Public use at Community Toilet |
| 137 | Dust Bin |
| 138 | PVC Mug (1.5 Ltr.) |
| 139 | Dust Bin (5 Ltr.) |
| 140 | Providing and fixing sanitary napkin vending Machine ladies side with 200 refills far as per norms of MOUD for best toilets . complete in all respect including the cost of equipments, Incinerator, battery for sanitary napkin Machine AVM, taxes, Delivery charges, installation charges, Training Charges and warranty |
| 141 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 142 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms |
| 143 | Electrical WorkSupply & laying PVC insulated Aluminum Conductor armoured ISI Marked cable of 3.5 Core 35 mm sq in Trench/Pipe. Supply & laying of ISI marked 3.5 core 35 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Havells/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1 MV CB PIP-25 Part-II (External). The work shall be executed to the entire satisfaction of Engineer-in-Charge. The specification of the cable as below:-i) Conductor – Aluminumii) Core – 3.5iii) Working Voltage – 1100 Viv) Nominal Cross Section – 35mm2 v) Minimum No. of Wire – 7/6 The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 144 | Supply & Laying of DWC pipe 51/63mm without hand bockey:- Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) Without Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930/ IS 16205 complete with fitting and cutting, jointing etc. direct in ground (depth as per the direction of Engineer in charge or upto 75 cm below ground level or cutting the road & laying) including excavation and refilling of digging including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. |
| 145 | Supply & Erection of Exhaust Fan (300mm) 900 RPM of Panasonic/ Havell’s/ Bajaj/ Philips/ Crompton make complete with motor blades along with louver to be installed on existing hole in wall/ glazing with suitable arrangement. The rate includes cost of all labour, carriage to site, testing, commissioning of Exhaust fan & connection to existing light panel. The job shall be executed to the entire satisfaction of Engineer-in-charge. |
| 146 | S/E of Ceiling Fans 1200mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Panasonic- Captor Kraft/ Havell's/ Bajaj/ Philips/ Crompton/ Orient including making connection with 23/.076' flexible wire to be adjacent fan point with regulator. The work shall be executed to the entire satisfaction of Engineer in charge. |
| 147 | Supply & Erection of 1x18/20 watt retrofit LED tube rod Supply & Erection of 1x18 watt retrofit LED tube rod made of aluminium housing with PC diffuser or its equivalent specification Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should be Panasonic/ Phillips/ Wipro/ Osram/ Surya/ Twinkle. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 148 | Providing and Fixing of LED luminarie recess/ surface mounting, Power coated housing made of CRCA sheet or its equivalent of size 2'x2' of 36-40 watt including driver with system Lumens 3600-4000 Im having efficacy of minimum 100 lm/W. THD <10%, PF > 0.95, Having coloured temperature 5700-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Philips/ Wipro/ Osram/ Havells/ Trilux/ Panasonic or its equivalent alongwith connection, testing and commissioning etc. The fitting may be installed at the height of 20 feet. There should be a on site warranty for 5 years. This job also inclusive of all material required at site for entire satisfaction of Engineer-in-charge. |
| 149 | Point wiring in PVC conduit, with modular type switch: Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulted copper conductor single core cable in surface/ recessed PVC Conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. Group-C |
| 150 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer) as required. 8 way (4+24), Double door Make of Panasonic, Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 151 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required complete in all respect. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. |
| 152 | S/F’C series, SP MCB Supply and fixing 6 amps to 32 amps rating, 240 volts ‘C’ series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing and commissioning etc as required. Single pole 16 Amps “C” series Make of Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge. |
| 153 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 154 | Supplying and fixing suitable size G.I. box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 155 | Supply& Erection of PVC insulated 2 core 10mm2 aluminium conductor twin core flat unarmured cable to fixed on the suitable clamp and nuts/ bolts etc make Rolex/ Sunhome/ Polycab/ Shalimar/ Havell's.The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 156 | PVCCON S/F PVC Conduit:Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. |
| 157 | 25 mm |
| 158 | 40 mm |
| 159 | S/E of M.S. bracket make out of M.S Channel of size 7.5mm x6mm & M.S. flat of size 12”x9” welded on the top of the M.S. Channel. The bracket should be painted with the coats of superior quality paint. The job includes all the material, labour including making holes in the bracket to fix the flood light fittings etc, complete in all respect. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 160 | Supply, Installation, Testing and Commissioning of Polycarbonate Junction box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The size in mm should not be less then 155 x 210 x 92 cat. Part no KF1616. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The Jb shall be rated for Degree of Ingress Protection IP 66/67 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded. The JBs shall be comples with requirements of the Standards IEC 60998-1, IEC 60998-2-1, IEC 60670 - 22 & 60670 - 2.5. The manufacturer of Junction Box shall submite a copy of IEC Certificate. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-11, DIV VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested and Glow Wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. The connecting terminal cabke entry should be fixed in junction box for incoming and outgoing. The box shall be Hensel/ Siemens/ Schneider/ ABB or its equivalent make only. Manufacturer should submit routine test certificate for CJB/PJB. The job includes Supply and fixing of MS clamp of reqd. size. The clamps is to be fixed on the backside of the box including welding/ drilling of holes complete in all respect and to be fixed on LT- RCC/ Steel tubular pole/ Wall at as certain height upto the entire satisfaction of Engineer-in-Charge. |
| 161 | S&E of Outdoor type both side openable M.S. Cubical Pedestal of size 900mmx 600mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mm x 100mm x 6mm thick at the bottom of the legs. The front side of the pedestal should be openable with hiunged door provided with Godrej type handle and L-key locking arrangements (with 2 sets of L-key). A 'U' type support made from M.S. sheet of 16 G having width 75mmx 6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. Four No. supporting members each of size 50mm x 6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN, BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. One No. The legs of the pedestal shall be embedded in the 1:2:4 C.C. mixture by digging 1' deep pit of 1' dia.The letter 'M.C.C.' in 4\\" size shall be written on the front door of the Pedestal. The job also included supply and erection one no. wooden plank/ board of size 1’-6’’ x 1’-6’’ and 25mm thick suitable for fixing energy mater including cost of screw, nuts and bolts in cubical pedestal complete in all respect. The pedestal will be housed on RCC foundation, Snowcem and platform of size 900 mm deep (450 mm underground and 450 mm above ground x 610 mm long x 360 mm wide including sufficient number of DWC pipe size of 51/63mm pieces to facility to entire the main cable and the circuit cable. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 162 | S&E of Mouled Case Circuit Breakers (MCCB) of rating 63 Amp with Breaking Cap 16 kA, 415 Volts.Supply & Erection of 3 pole, 16 kA, 63 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 163 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. Make: Havell's/ Panasonic/ Polycab/ Ecko/ KEI |
| 164 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 165 | 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 166 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 167 | G.I. Earth pipe electrode without salt/ Charcoal: Supply and laying of earth electrode made out of ISI marked 'B' class earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, G.I. pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom (without charcoal or coke and salt). The earth electrode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge. |
| 168 | P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. |
| 169 | S/E of Wall fans 400mm sweep without fan regulator of Panasonic- Flora Neo/ Havell's/ Usha/ Baja/ Orient make including making connection with 23/.076’ flexible wire to be adjacent fan point. The job shall be executed to the entire satisfaction of Engineer-in-charge. |
| 170 | S/F modular boxes, base & cover plate: Supplying and fixing following size/modules, G.I. box alongwith modular base & cover plate for modular switches Anchor/ Havell's/ Panasonic/ Philips or it's terminal equivalent make in recess etc as required. |
| 171 | 1 or 2 Module (75mmX75mm) |
| 172 | Supplying and fixing of modular type electronics fan regulator:-Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 173 | S/F brass holderSupplying and fixing brass batten/ angle holder including connection etc as required. |
| 174 | S/F modular type switch/socket: Supplying and fixing following modular switch /socket on the exisiting modular plate & switch box including connections but excluding modular plate Anchor/ Havell's/ Panasonic/ Philips or it's terminal equivalent make in recess etc as required. |
| 175 | 5/6 Amp switch |
| 176 | 3 pin 5/6 Amp socket outlet |
| 177 | S/F call bell/ buzzer: Supplying & Fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. |
| 178 | Providing, Fixing and Commissioning of Split type AC of 1.5 ton, 3 Star Rating. The AC shall be Suitable for 230 +/- 10% volts, 50 Hz Ac supply. The cost of including piping / Electrical Wire between indoor & outdoor up to two meter with sleeve in type insulation I/C M.S brackets/stand for outdoor until as per manufactures standard i.e. for fixing on wall or floor/terrace as per site requirements complete in the entire satisfaction of Engineer-in-charge. The AC EER not less than 3.55 supply with Copper condenser. 1.5 Ton Capacity of nominal cooling capacity 4500 kilo calories/Hr./18000 BTU/Hr. with permissible variation of +/- 10%. Room discharge air flow 650 cfm indoor Nosir level not exceed 50 db. Refrigent 410 A/R32. Machine should have in built gas leak detector. The make should be Carrier/ Hitachi/ Toshiba/ Mitsubishi or its equivalent. There should be warrantee of 3 years in all respect to the entire satisfaction of Engineer-in-charge. |
| 179 | Providing and Fixing of voltage stabilizer 4 KVA for AC of 1.5 Ton and above with MCB, TDR volt meter copper winding input range 180-250 volt single phase including cost of copper wire from stabilizer to AC unit with M.S. Body of 22 gauge sheet powder coated. Make: V-Guard/ Microtek/ Luminous. |
| 180 | Providing and Fixing of MS Stand for Outdoor unit of 1.5 Ton Air Conditioners. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 181 | Providing and fixing of 28 gauge copper piping between indoor & outdoor unit complete with sleeve type Kini insulation including the cost of chasing of brick wall, RCC & repairing the same in good conditions as per site requirement to the size & design of manufacture. size of copper pipe 5/8\\"x3/8\\". The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 182 | Providing & Fixing PVC rigid drain pipe 25mm (3/4\\") dia of Diplast/ finolex make complete in all respects from indoor unit to disposal points as directed by Engineer in charge complete in all respects. |
| 183 | Supply & Erection of PVC Insulated (sheathed) Copper Conductor Cable ISI marked size 3 core 2.5 mm2.Supply & Erection of ISI Marked PVC insulated 3 core 2.5mm2 cable of Copper Conductor (Sheathed) make Finolex/ Lapp/ Polycab/ Cirtina/ Havell's/ left barel/ Panasonic in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size 3 core 2.5 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 184 | Supply & Erection of high power LED 80-90 Watt Flood Light luminaries:High-brightness White LEDs sources with high transmittance LENS on each LEDs, system lumen output of Minimum 8000-9000 lumens, in Maximum 80-90 Watt Max Power System Consumption with 110 lms/Watt system luminous efficacy, 4000 + 275 Kcolor temperature & 70 CRI value for ensuring good quality light output. Life of at least 50,000 hours at 70% lumen maintenance & LED Potted driver efficiency >95% Power factor greater than 0.90, THD<10% & min 4KV surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit mis wiring, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK08 & above, IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 5 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge. The LED Flood light Fixture shall be installed on 12.5 mtr long pole. The luminary should be Wipro/ Bajaj/ Philips/ Crompton/ Osram/ Havells/ Trilex/ Panasonic/ HQ. The detailed specification for supply of 80-90 Watt Max Power LED Flood light luminaries is as under (with 05 years warranty) :- (Drive should be potted, rate include reducer if required)1. Input voltage 150-270VAC/50Hz 2. System Efficacy Minimum 110 Lm/W3. Uniformity Ratio of min to Av illumination Min 0.34. Usage hours 10-12 Hrs/day5. Power Factor 0.956. Life Expectancy Minimum 50,000 Hrs with 70% Lumens 7. Power Consumption of system 80-90 Watt Maximum 8. Lumen output Minimum 8000-9000 Lumens 9. Color temp. 4000 + 275 K 10. LED High Power SMD LED 11. Working Humidity 10% to 90% as 1 to MSL 12. Ingress protection IP-66 |
| 185 | 13. Surge Protection Minimum 4KV14. Coloring Rendering Index >70 15. Total Harmonic Distortion 15%Max 16. Average lighting Beam Angle 120 Deg 17. Make of LED Wipro/ Bajaj/ Philips/ Crompton/ Osram/ Havells/ Trilex/ Panasonic/ HQ. 18. Luminary Casing Pressure die cast aluminum 19. Control of circuit Compatible to LED20. Lamp starting time Should not be more than 10 Sec21. Thermal Management system Good Thermal Management system Management of LED should be provided and LED must be Mounted on heat sink conductive Aluminum with suitable large area Surface by means of fins to disciple Heat to ambient air.22. System Driver more than 85% Efficiency 23. Applicable standard The fixture should confirm to Application BIS/IES standard/IESNA LM8024. Wind pressure capable to with stand 160 MPH wind velocity 25. Manufacturer should produce NABL accredited LM 79 & LM-80 Lab certificate for verifying the above mentioned system Lumen output, system power consumption & system Luminous efficacy. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail