| 1 | Item Description |
| 2 | Providingandfixingpanelled/orpanelledandglazedshutters fordoors,windowsandclerestorywindowsincluding ISI marked bright finished / blackenamelled M.S butt hinges with necessary screwsexcludingpanellingandorglazing,whichwillbepaidforseparatelybutincludingthewoodenbeadingof20×12mmfor fixingpanellingandor glazingasperdirection of Engineer-In-Charge. Gamair Wood 35 mm thick shutters |
| 3 | Providing and fixing ISI marked flush door shuttersconforming to IS: 2202 (Part I) decorative type, core ofblock board construction with frame of 1st class hardwood and well matched teak 3 ply veneering withvertical grains or cross bands and face veneers onboth faces of shutters. 35 mm thick including ISI marked Stainless Steel butthinges with necessary screws. |
| 4 | Providing and fixing IS : 1341markedM.S. heavyweight butt hinges with necessary screws etc.complete : 125 × 90 × 4.00 mm |
| 5 | Providing and fixing IS : 1341markedM.S. heavyweight butt hinges with necessary screws etc.complete : 75 × 60 × 3.10 mm |
| 6 | Providingandfixing ISImarkedoxidisedM.S. towerboltblackfinish, (Barrel type)withnecessaryscrewsetc. complete : 250x10 mm |
| 7 | Providing and fixing IS : 3564marked aluminiumextruded section body tubular type universalhydraulicdoor closerwithdoublespeedadjustmentwith necessary accessories and screws etc. complete. |
| 8 | Providing and fixingbright finishedbrass 100mmmortice latchand lockwith6 levers anda pair oflever handleswith necessary screws etc. complete(best make of approved quality) |
| 9 | Providing and fixing aluminiumhandles ISImarkedanodised(anodiccoatingnot lessthangradeAC10asper IS : 1868) transparentordyedtorequiredcolouror shade with necessary screws etc. complete : 125 mm |
| 10 | Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded builtup standard tubular sections/ appropriate Z sectionsand other sections of approved make conforming toIS: 733 and IS : 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up ofgaps at junctions, i.e. at top, bottom and sides withrequired EPDM rubber/neoprene gasket etc. Aluminiumsections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleatangle, aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as perarchitectural drawing and the direction ofEngineerincharge. (Glazing and paneling and dashfasteners to be paid for separately) : For fixed portion of approved quality: Anodised aluminium (anodised transparent or dyed torequired shade according to IS: 1868, Minimum anodiccoating of grade AC 15). |
| 11 | Providing and fixing glazing of approved quality inaluminium doors, windows, ventilator, shutters andpartition etc. with EPDM rubber / neoprene gasket etc.complete as per architectural drawing and the directionof Engineer-in-charge (Cost of snap beading shall be paidin basic item) : With float glass panes of 5.5 mm thickness ( weight not lessthan 13.75 kg / sqm ) |
| 12 | Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., includingcutting, hoisting, fixing in position and applying apriming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 13 | Providing and fixing precoated galvanised iron profilesheets (size, shape and pitch of corrugation as approvedby Engineer-in-charge) 0.50 mm (+ 0.05 %) total coatedthickness with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primeron both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25microns minimum to avoid scratches duringtransportation and should be supplied in single lengthupto 12 metre or as desired by Engineer-in-charge. Thesheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, completeupto any pitch in horizontal/ vertical or curvedsurfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shapewherever required and as per direction of Engineer-incharge. |
| 14 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering --All work upto plinth level: 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brickaggregate 40 mm nominal size) |
| 15 | Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts includingspreading in horizontal layers, watering, grading torequired slope, ramming, consolidating and compactingeach layer by using plate compactor or by any suitablemethod complete. |
| 16 | Providing and laying 1st class quality ceramic floor tilesin different sizes (thickness to be specified by themanufacturer) of 1st quality conforming to IS : 156222017 of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid over 20 mm thick cementmortar 1:4 (1 cement : 4 fine sand), Jointing with greycement slurry @ 3.3 kg/sqm including pointing the jointswith white cement and matching pigment etc. allcomplete as per direction of the Engineer in-charge. 300 mm x 300 mm in all shades and designs Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles |
| 17 | Repairs to plaster of thickness 12 mm to 20 mm inpatches of area 2.5 sqm and under including cutting thepatch in proper shape and preparing and plastering thesurface of the walls complete including disposal ofrubbish to the dumping ground with all leads and liftsincluding finishing even and smooth and curingcomplete as per direction of the Engineer in charge: With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 18 | Distempering with 1st quality washable acrylicdistemper of approved brand and manufacture and ofrequired shade on old work ( one or more coats ), togive an even shade as required complete as perdirection of the Engineer in charge. |
| 19 | Finishing walls with acrylic smooth exterior paint ofrequired shade of approved brand and manufacture onold work ( one or more coats ) including preparation ofsurface as required complete as per direction of theEngineer in charge. |
| 20 | Painting with synthetic enamel paint ( one or morecoats ) of required colour of approved brand andmanufacture on old work to give an even shadeincluding preparation of surface as required completeas per direction of the Engineer in charge. |
| 21 | Floor painting with floor enamel paint ( one or morecoats ) of approved brand and manufacture of requiredcolour on old work to give an even shade includingpreparation of surface as required complete as perdirection of the Engineer in charge. |
| 22 | Providing and fitting fixing of A.C Machine (Godrej/Saamsung/Blu Star/Haier/LG Make/ Hitachi) split type 1.5 ton capacity alongwith accessories like industrial socket, electric wire etc. complete as per direction of the Engineer-in-charge |
| 23 | Providing and fixing in wall lining flat pressed threelayer (medium density) particle board or graded woodprelaminated one side decorative lamination on otherside balancing lamination Grade I,Type II, IS : 12823marked including priming coat on unexposed surface,with necessary fixing arrangement and screws etc.complete. 25 mm thick |
| 24 | Providingwoodwork in framesof doors,windows,clerestorywindowsandotherframes,wroughtframedand fixed in position : Local Teak Wood |
| 25 | Supplying, fittin & fixing stainless steel letters (Golden Colour Finish) of 10 inch height and proportionate widh, with proper alognment and good finishing, including all necessary accessories such as screws, adhesives, fasteners, fixtures, etc. complete as per direction of the engineering-in- charge. (Dy. Director of Fisheries, Gomati District) |
| 26 | Steel tubular resting chair (with cushioned seat and back with arm) (Godrej 7B) |
| 27 | steel table full secretariat laminated sheet top three drawers with automobile locking device to the right side and a cupboard with one drawer to the left side stotage unit size H20''Xw25''(60''X30''X30'') Please Enable Macros to View BoQ information |