| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. Excavation work by mechanical means /manual means upto 1.5 m. |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in:1:4 (1 cement : 4 sand) |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in:1:6 (1 cement : 6 sand) |
| 11 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in super structure above plinth level up to floor v level in all shapes and size in:1:4 (1 cement : 4 sand) |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in super structure above plinth level up to floor v level in all shapes and size in:1:4 (1 cement : 4 sand) |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | 12 mm cement plaster of mix : 1: 6 (1 cement : 6 coarse sand) |
| 16 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement : 6 coarse sand) |
| 17 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. |
| 18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 19 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm. |
| 20 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 21 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 22 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.complete. |
| 23 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 24 | Supply & fixing of flush doors commercial quality conforming to IS 2202 Part-1 (1983) including fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks handles, springs and other fitting but excluding their supply and including painting with two coats of black japan paint on iron fitting of necessary fitting with departmentally. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 35 mm Thick Single leaf |
| 25 | Supply & fixing of flush doors commercial quality conforming to IS 2202 Part-1 (1983) including fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks handles, springs and other fitting but excluding their supply and including painting with two coats of black japan paint on iron fitting of necessary fitting with departmentally. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 35 mm Thick Double leaf |
| 26 | Supply & fixing of flush doors commercial quality conforming to IS 2202 Part-1 (1983) including fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks handles, springs and other fitting but excluding their supply and including painting with two coats of black japan paint on iron fitting of necessary fitting with departmentally. both side laminated |
| 27 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Providing & fabricated of hold fast for chaukhats of doors and windows. |
| 28 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Z-Section steel windows (openable) |
| 29 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 2nd class teak wood beading 62X19 mm |
| 30 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . |
| 31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 lit/10 sqm) |
| 32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 33 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 34 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 35 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 36 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 37 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 38 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortarof mix 1:4 (1 cement :4 coarse sand) admixed with waterproofing compound conforming to IS : 2645 and approved byEngineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 39 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 40 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending |
| 41 | Providing and fixing wooden Glass partition with book rack/book shelf, made of seasoned hardwood/plywood board as per approved design, including frame work, shelves, side panels, back panel, necessary screws, nails, adhesive, edge beading, polishing/laminate finish, labour, tools, carriage and all complete as directed by Engineer-in-Charge. |
| 42 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 43 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 44 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, buttresses and cantilevers. |
| 45 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. |
| 46 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 47 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. |
| 48 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Felxible pipe a) 32mm dia |
| 49 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 50 | Providing & fixing 60x2cm. C.P. brass towelrail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screw. ESSCO AEC-1111 |
| 51 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 52 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. (Internal Work) Expansion on Wall 32 mm dia nominal bore. (medium duty) |
| 53 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. 32 mm diameter pipe. |
| 54 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes |
| 55 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 40 mm nominal outer dia Pipes |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 58 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110mm diameter |
| 59 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm |
| 60 | Providing & fixing CPVC pipes complete with CPVC fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. a) 25mm dia nominal bore (medium duty) |
| 61 | Providing & fixing CPVC pipes complete with CPVC fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. 15mm dia nominal bore |
| 62 | Providing & fixing CPVC pipes complete with CPVC fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. b) 20mm dia nominal bore |
| 63 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. a) 15mm nominal bore |
| 64 | Providing & fixing CP brass short body of approved quality conforming to IS 8931 a) 15mm nominal bore |
| 65 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15mm nominal bore |
| 66 | Providing and fixing gun metal gate valve with wheel of approved quality. 25 mm nominal bore |
| 67 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete a) 20 mm nominal bore |
| 68 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. |
| 69 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work a) 100 mm dia meter |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work b) 150 mm diameter |
| 71 | Providing and fixing square mouth UPVC S.W.R. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. a) 150 x 110 mm. size P type With Sewer bricks conforming to IS : 4885 |
| 72 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80X50cms including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 150 (i) For Sewer Line |
| 73 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80X50cms including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 150 Extra for depth of man hole size 90x80 cm |
| 74 | Point wiring in PVC conduit, with piano type switch :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 75 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 76 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 77 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 78 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 79 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 80 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 81 | S/F light plug point piano type accessories :- Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 82 | S/F power plug point piano type accessories :- Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 83 | Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 poles and earth metal enclosed plug top along with 20 amps. \\"C\\" curve, SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. |
| 84 | S/F modular type electronic fan regulator :- Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 85 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 20 mm. |
| 86 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 25 mm. |
| 87 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 32 mm. |
| 88 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole |
| 89 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 90 | S/F DP MCB Isolator Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 40 Amps |
| 91 | S/F DP MCB Isolator Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 63 Amps |
| 92 | S/F TP MCB Isolator Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 63 amps. |
| 93 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps. |
| 94 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps. |
| 95 | Supplying and fixing following way, SP&N, sheet steel, MCB distribution board, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) 6 way, Double door |
| 96 | Supplying and fixing following way, horizontal type TP&N, sheet steel MCB distribution board, 415 V on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 4 way (4 + 12), Double door |
| 97 | Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/ coke and salt as required. |
| 98 | Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 99 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 100 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required. |
| 101 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 102 | Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription single red colour on FRLSont side as required. |
| 103 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 104 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable |
| 105 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 5/6 A switch |
| 106 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 107 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 108 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 109 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 110 | Supplying and fixing Internet Socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 111 | Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 112 | Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 113 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 114 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 115 | Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. |
| 116 | Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 2X22 watt suitable for upto 2X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. |
| 117 | Supply of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. |
| 118 | Supply of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 230 mm sweep |
| 119 | Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.2mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel : Incoming : One (1) No300Amp. 4 pole MCCB Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-300A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 300 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 63 Amps TPN MCB - 3No. 40 Amps TPN MCB -3No. 32 Amps TPN MCB - 2 No. 63 Amps TPN MCB - 1No. Spare 40 Amps TPN MCB - 1No. Spare |
| 120 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core |
| 121 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 sq. mm 3-1/2 core |
| 122 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 16 sq. mm 4 core |
| 123 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 35 sq. mm (35mm) |
| 124 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1.50m to 3.00M |
| 125 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 3.00 m to 4.50 m |
| 126 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster. |
| 127 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 128 | Providing and fixing 150 mm S.C.I. tee at the inlet and outlet of septic tank. |
| 129 | Providing & fixing 75mm dia vent pipes. |
| 130 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 131 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter |
| 132 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.L.D. -2.5- Circular shape 450mm internal diameter |
| 133 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 15 |
| 134 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. |
| 135 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter |
| 136 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) upto haunches of S.W. Pipes including bed concrete as per standard design. 100mm diameter S.W. Pipe |
| 137 | Supply and stacking of graded stone aggregate of 45-90mm size |
| 138 | Supply and stacking of stone chippings of 11.20mm size |
| 139 | Supply and stacking of moorum at site |
| 140 | onstructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slabwith 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 finesand : 10 graded stone aggregate 40 mm nominal size), inside Plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarsesand), finished smooth with a floating coat of neat cement on wallsand bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep forsingle pipe line : With common burnt clay F.P.S. (non modular) bricks ofclass designation 15 |
| 141 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitablemethod prescribed in IS: 2800 (part I), including collecting samples fromdifferent strata, preparing and submitting strata chart/ bore log, includinghire & running charges of all equipments, tools, plants & machineriesrequired for the job, all complete as per direction of Engineer -in-charge,upto 90 metre depth below ground level. 300 mm dia |
| 142 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 143 | Supply and fixing of nylon jali around the slotted pipes complete as required. |
| 144 | Transport of boring tools other required equipments and installation at site. |
| 145 | Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter |
| 146 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design 100mm dia SW pipe |
| 147 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type |
| 148 | Supply & installation of Split Direct Expansion Air Conditioners Suitable for operation on A/C supply single phase 50HZ 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitor, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High Wall Chorded/ Cordless) Suitable Capacity 3 Core sheathed/ PVC copper cable and a battery operated wireless remote unit. BEE 5STAR EER 3.4 (1.5 TR) MR |
| 149 | Supply & installation of Split Direct Expansion Air Conditioners Suitable for operation on A/C supply single phase 50HZ 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitor, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High Wall Chorded/ Cordless) Suitable Capacity 3 Core sheathed/ PVC copper cable and a battery operated wireless remote unit. BEE 5STAR EER 3.4 (2.0 TR) MR |
| 150 | Supply and installation Voltage Stabilizer Brand Make V-Guard at proper completion at site |
| 151 | Providing and supplying Executive Table for E-Cabin of size 1800 mm × 900 mm × 750 mm high, made of pre-laminated particle board/MDF with all necessary fittings, complete as directed by Engineer-in-Charge. |
| 152 | Providing and supplying Executive Chair for E-Cabin, high back revolving chair with cushioned seat and back, complete. |
| 153 | Providing and supplying Librarian Table of size 1800 mm × 900 mm × 750 mm high, made of pre-laminated particle board/MDF with drawers and storage unit, complete. |
| 154 | Providing and supplying Librarian Chair, high back revolving chair with armrest and cushioned seat, complete. |
| 155 | Providing and supplying Visitor/Guest Chair for Librarian, cushioned seat with powder-coated steel frame, complete. |
| 156 | Providing and supplying Student Reading Table for 4 students, size 2400 mm × 1200 mm × 750 mm high, made of pre-laminated board with edge banding and necessary supports, complete. |
| 157 | Providing and supplying Student Chair, overall size approximately 450 mm × 450 mm × 850 mm high, complete. |
| 158 | Providing and supplying Steel Almirah of size 900 mm wide × 450 mm deep × 1980 mm high, with 4 shelves, locking arrangement and powder-coated finish, complete. |
| 159 | Providing and supplying Librarian Steel Almirah of size 900 mm wide × 450 mm deep × 1980 mm high, with shelves and locking arrangement, complete. |
| 160 | Providing, supplying, installing, testing and commissioning of floor-mounted Interactive Touch Screen Kiosk complete with minimum 43-inch Full HD LED display, 10-point multi-touch capacitive touch technology, Intel i5 processor or higher, 8 GB RAM, 256 GB SSD, Windows operating system, inbuilt speakers, LAN/Wi-Fi connectivity, USB ports, powder-coated MS enclosure, tempered glass protection, power supply unit, all required accessories, software integration, wiring, fixing arrangements and commissioning for online information display and public interaction, complete in all respects as directed by Engineer-in-Charge.\\" |
| 161 | Supply, Installation, testing and commissioning of Dome Camera (I.P.) Full HD image with a 1/2.7\\" 2 megapixel sensor or full HD 4 MP 20 fps image with a 1/3\\" 4 megapixel sensor. |
| 162 | Supply, Installation Hard disk Surveillance 8 TB |
| 163 | Supply, Installation RACK 12 U |
| 164 | Supply, Installation D.Link |
| 165 | Supply, Installation LED Screen 50\\" |
| 166 | Supply, Installation patch panel 24 port/fiber |
| 167 | Supply, Installation Sfp Model |
| 168 | Supply, Installation Fiber Cabin |
| 169 | Supply, Installation CAT6 UTP cable 305 mtr |
| 170 | Supply, Installation Online UPS with 30 Min Backup |
| 171 | Supply, Installation HDMI Cable 10 Meter |
| 172 | Supply, Installation Supply & Installation of CAT 6A Cable |
| 173 | Supply, Installation Connector RJ-45 |
| 174 | Supply, Installation Cable Laying charges (Per Meter) |
| 175 | Installation Charge of Camera |
| 176 | S/F of Surface mount box with I/O Cat 6 and UTP jack D-Link complete in all respect Make Dlink/Amp |
| 177 | S/I of Patch cord CAT6 UTP Make Dlink/Amp |
| 178 | S/I/T/C of 24 port category 6e SL Series patch Panel Make Dlink/Amp with active and passive components,punching, complete in all respect |
| 179 | Supplying, installing, testing and commissioning of 24 10/100/1000BASE-T PoE-plus |
| 180 | Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. |
| 181 | Mapping of Network Nodes & LAN Diagram |
| 182 | SITC of WIFI Modem suitable to cover atleast 25m distance having compatibility to connect atleast 40-50 devices without any distortion in signal etc as required. |
| 183 | Providing, Supplying, Installing, Testing and Commissioning of Sensor Based Automatic Entrance System complete with automatic door operator, motion sensors, safety sensors, controller, power supply unit, wiring, fixing accessories and all necessary components required for satisfactory operation of the system complete in all respects Make/Model and technical specifications shall be as approved by Engineer-in-Charge |
| 184 | Supply, installation, testing and commissioning of recessed LED panel light fitting of size 600 mm × 600 mm, minimum 36 Watt, complete with driver, accessories, fixing arrangement in false ceiling, connection with existing wiring and testing complete as required. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail