| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group-B |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group-B |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 4 | b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 5 | c) 2X 6 sq. mm + 1X 6 sq. mm earth wire |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm. |
| 7 | b) 25 mm. |
| 8 | c) 32 mm. |
| 9 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 10 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 1 or 2 Module (75mmX75mm) |
| 11 | b) 3 Module (100mmX75mm) |
| 12 | c) 6 Module (125mmX75mm) |
| 13 | d) 8 Module (200mmX75mm) |
| 14 | e) 12 Module (125mmX125mm) |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch |
| 16 | b) 3 pin 5/6 A socket outlet |
| 17 | c) 15/16 A switch |
| 18 | d) 6 pin 15/16 A socket outlet |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way, Double door. |
| 20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole |
| 21 | b) Double pole |
| 22 | c) Single pole and neutral |
| 23 | c) Triple pole and neutral |
| 24 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 25 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 26 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 27 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:- heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 18- 22 Watt with Powder coated die cast /Extruded aluminium Body (Thickness> 1.20 mm) |
| 28 | Supply and fixing of 10 Watt LED lamp with polycarbonate housing and integrated electronic driver as complete as required. |
| 29 | Supply and fixing of 10 Watt bulkhead luminaire (IP 65) with polycarbonate housing on wall surface etc. as complete as required. |
| 30 | Supply and fixing of 18 Watt round/square with CTT 3000/4000/5700/6500, indoor type, 220V, 50 Hz, THD< 10%. PF>= 0.95, IP 20 atleast, CRI> 80, fliker free with LED driver, lumen efficacy>= 120 lm/watt, slim fancy surface / recess LED luminaires with LM79, LM80 testing report and manufacturer nameand specifications engraved/ embossing/ screen printing of housing with inbuilt driver i/c connection etc. as required. |
| 31 | Supplying, installation, Testing & Commissioning of LED Panel light with dimension 2x2 ft (System lumen efficacy ≥105 <120 lm/Watt), of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 22 Watt with Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 32 | Supply and installation of ventilating fans of following sweep sizes i/c connection etc.as required. a) 230 mm. |
| 33 | b) 300 mm. |
| 34 | Supply and installation of exhaust fans of following sweep sizes i/c connection etc.as required. a) 300 mm. |
| 35 | b) 400 mm. |
| 36 | Supply and installation of Geyser of 25 liters capacity i/c connection and testing etc. |
| 37 | Lumpsum credit of dismentled material like M.S./ PVC conduit, switch, socket, wire etc. against item No. 2 Please Enable Macros to View BoQ information |