| 1 | Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed surfaces complete all as specified and as directed. |
| 2 | M&L for point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLSH copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC conduit & PVC casing capping 20/25/32/40 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC switch board on existing wall surface for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall complete all as specified and as directed. Note: - (i) Rate quoted shall include provision of blank plates as per site requirement (No extra payment will be made for the same) |
| 3 | All as per Item No 2 here-in-before but for one 5 pin socket outlet 5 Amps on independent board with 1.5 Sqmm complete all as specified and as directed. |
| 4 | All as per Item No 2 here-in-before but One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size complete all as specified and as directed. |
| 5 | All as per Item No. 2 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 4 Sqmm copper cable FRLSH & 4 Sqmm FRLSH copper cable for earth continuity wire complete all as specified and as directed. |
| 6 | S&F for switch piano flush type 6 Amp single pole one way complete all as specified and as directed. |
| 7 | S&F for socket flush type 6 Amp 5 Pin complete complete all as specified and as directed. |
| 8 | S&F for switch socket combination 5 Pin 6 Amp universal complete all as specified and as directed. |
| 9 | S&F for switch socket combination 5 Pin, 6/15 Amp universal complete all as specified and as directed. |
| 10 | S & F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed. |
| 11 | S & F call bell, ding dong AC 230 volts, single pole complete all as specified and as directed. |
| 12 | S & F bell push, flush type, 5 amp complete all as specified and and directed. |
| 13 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all complete and as directed. |
| 14 | S&F sub main wiring with 2 run of 4.0 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLSH working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC conduit & casing/caping (20/25/32/40 mm width) including size 4.0 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB\\"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface complete all as specified and as directed. ( NOTE :- Two runs of 4.0 Sqmm pvc wire, one run of 4.0 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit |
| 15 | S&F sub main wiring with 2 run of 6.0 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLSH working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC conduit & casing/caping (20/25/32/40 mm width) including size 6.0 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB\\"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface complete all as specified and as directed. ( NOTE :- Two runs of 6.0 Sqmm pvc wire, one run of 6.0 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit |
| 16 | S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. |
| 17 | S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. |
| 18 | S&F VTPN distribution board with provision of MCCB as incommer, double door suitable for mounting MCB's/Isolators, 415 Volt,4 way with built in 160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed.Note: Incoming cable to VTPN DB to be clamped to wall incl. necessary conduit and streamlined. Also any kind of dismantling of sheet metal enclosure accompanied by brickwork to make good disturbed surfaces is deemed to be included in quoted price. |
| 19 | S & F MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 16KA complete all as specified and as directed. |
| 20 | S & F MCB, SP, 240V, 40 Amps and ' B ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed. |
| 21 | S & F MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed. |
| 22 | S & F MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , all as specified and as directed. |
| 23 | Supply and fix ceiling fan regulator electronic Step type, solid state, 120W, 2 module, 240 volts, complete all as specified and as directed. |
| 24 | S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket complete all as directed . |
| 25 | S&F in repair for wall mounted LED 4 feet 20 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 26 | S&F in repair for wall mounted LED 2 feet 10 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 27 | S & F conical/globe shaped post top lantern LED type 40 Watt 230 V AC outdoor type with decorative top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete incl. fittings viz. tube bends, tubes, etc to mount complete all as specified and as directed. |
| 28 | Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 29 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 30 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level, connected to earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI wire protected by 20 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 40 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I complete all as specified and as directed. |
| 31 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 8 mm galvanised iron or steel wire, complete all specified & directed by Engr-in-Charge. |
| 32 | S & F in repair GI Street Light Pipe with 105-135 deg bend, 32-40 mm diameter and length not less than 01 meter incl. fixing accessories such as saddles, holderbats, clamps, nut-bolts, etc. & one coat of primer, two coat of Aluminium paint complete, all as specified and as directed. |
| 33 | Supply & Fixing in repair of LED street light fitting 35 W, 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, surge protection, complete, all as specified and directed. |
| 34 | Supply, Installation, Testing & Commissioning of outdoor type LT Distribution Panel 415 V, 3-ph, 50 Hz of size not less than 0.6 (H) x 0.6 (W) x 0.4 (D) made out of CRCA sheet 3.15 mm thick outdoor totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, weather and waterproof having copper busbars of capacity 250 A for R,Y,B and Neutral with heat proof colour code and mounted on insulators, stickering of switchgears, danger notice plate, including connecting incoming and outgoing cables with 40 x 40 x 6 mm angle legs of length not less than 70 cm fixed to necessary PCC 1:3:6 foundation on ground comprising the following:-Incoming(a) MCCB 200A, 4P, 415 V, 50 Hz, Adjustable type with rupturing capacity of 36 KA -01 No. Make:L&T/ Havells/ Schneider/C&S electric(b) LED Indicating lamps (R,Y,B) - 01 set. Make: C&S/Neptune/L&T/Vaisnavo(c) Digital Three Phase VIF Meter with VLN, VLL, I1, I2, I3, F measurement -01 No. Make: L&T, Schneider, C&S electric(d) Socket outlet 2 in 1, 3 pin, 6 and 6A flush type-01 No.(e) MCB 6A, 'C' curve with breaking capacity 10kA-03 Nos.(f) CT 200/05, 5VA, cl-1.0-01 Set (03-ph)Outgoing(a) 04 Nos. threaded busbar (03 thread on each strip) of current carrying capacity 250A each with heatproof colour code for R, Y, B & N.(Note: Cost includes necessary power/control wiring connections, lugs/gland/spreader links other accessories necessary for LT Panel construction) |
| 35 | Supply, Installation, Testing & Commissioning of outdoor type LT Distribution Panel 415 V, 3-ph, 50 Hz of size not less than 0.6 (H) x 0.6 (W) x 0.4 (D) made out of CRCA sheet 3.15 mm thick outdoor totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, weather and waterproof having copper busbars of capacity 200 A for R,Y,B and Neutral with heat proof colour code and mounted on insulators, stickering of switchgears, danger notice plate, including connecting incoming and outgoing cables with 40 x 40 x 6 mm angle legs of length not less than 70 cm fixed to necessary PCC 1:3:6 foundation on ground comprising the following:-Incoming(a) MCCB 160A, 4P, 415 V, 50 Hz, Adjustable type with rupturing capacity of 36 KA-01 No. Make:L&T/ Havells/ Schneider/C&S electric(b) LED Indicating lamps (R,Y,B) - 01 set. Make: C&S/Neptune/L&T/Vaisnavo(c) Digital Three Phase VIF Meter with VLN, VLL, I1, I2, I3, F measurement -01 No. Make: L&T, Schneider, C&S electric(d) Socket outlet 2 in 1, 3 pin, 6 and 6A flush type-01 No.(e) MCB 6A, 'C' curve with breaking capacity 10kA-03 Nos.(f) CT 200/05, 5VA, cl-1.0-01 Set (03-ph)Outgoing(a) 04 Nos. threaded busbar (03 thread on each strip) of current carrying capacity 200A each with heatproof colour code for R, Y, B & N.(Note: Cost includes necessary power/control wiring connections, lugs/gland/spreader links other accessories necessary for LT Panel construction) |
| 36 | Supply, Installation, Testing & Commissioning of outdoor type LT Distribution Panel 415 V, 3-ph, 50 Hz of size not less than 0.6 (H) x 0.6 (W) x 0.4 (D) made out of CRCA sheet 3.15 mm thick outdoor totally enclosed with front & rear opening, hinged doors alongwith suitable locking arrangements, weather and waterproof having copper busbars of capacity 125 A for R,Y,B and Neutral with heat proof colour code and mounted on insulators, stickering of switchgears, danger notice plate, including connecting incoming and outgoing cables with 40 x 40 x 6 mm angle legs of length not less than 70 cm fixed to necessary PCC 1:3:6 foundation on ground comprising the following:-Incoming(a) MCCB 100A, 4P, 415 V, 50 Hz, Adjustable type with rupturing capacity of 16 KA-01 No. Make:L&T/ Havells/ Schneider/C&S electric(b) LED Indicating lamps (R,Y,B) - 01 set. Make: C&S/Neptune/L&T/Vaisnavo(c) Digital Three Phase VIF Meter with VLN, VLL, I1, I2, I3, F measurement -01 No. Make: L&T, Schneider, C&S electric(d) Socket outlet 2 in 1, 3 pin, 6 and 6A flush type-01 No.(e) MCB 6A, 'C' curve with breaking capacity 10kA-03 Nos.(f) CT 100/05, 5VA, cl-1.0-01 Set (03-ph)Outgoing(a) 04 Nos. threaded busbar (03 thread on each strip) of current carrying capacity 125A each with heatproof colour code for R, Y, B & N.(Note: Cost includes necessary power/control wiring connections, lugs/gland/spreader links other accessories necessary for LT Panel construction) |
| 37 | S & F in repair On Load Changeover Switch 4P, 400 A, 415 V AC, 50 Hz Open Execution Item conforming to IS / IEC: 60947- 3 complete all as specified and as directed. |
| 38 | S&F in repair MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 36 KA (Rotary Handle/Extended Rotary Handle/Toggle Type) complete all as specifies and as directed. |
| 39 | S&F in repair MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA (Rotary Handle/Extended Rotary Handle/Toggle Type) complete all as specifies and as directed. |
| 40 | S&F in repair MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA (Rotary Handle/Extended Rotary Handle/Toggle Type) complete all as specifies and as directed. |
| 41 | S&F in repair MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA (Rotary Handle/Extended Rotary Handle/Toggle Type) complete all as specifies and as directed. |
| 42 | Dismantling complete ceiling fan (of size 1200/1400/1500 mm sweep-single phase IM or BLDC based) alongwith down rod, canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out stator, motor winding, ball bearings, gun metal bush, PCB etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufractures design and directed and re-assembling (b) New spare parts (i.e) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, shaft, PCB, twin twisted copper cable shall be measured and paid separately under relevant item. However, cost of AC connector/DC connector for BLDC ceiling fans shall deemed to be included in the quoted price of current serial. |
| 43 | Taking down carefully ceiling fan, sealing cable end, dismantling blades and body casing for repair/replacement of microcontroller PCB/any other accessories of BLDC fan, reassembling the same after repair and hanging back the fan to ceiling complete, all as specified and directed.Note: Spare parts will be measured under relevant serial. |
| 44 | Supply and fixing ceiling fan shackle kit complete with fan rod nut-bolts, hook nut-bolts in rubber bushing and lock pin suitable for ceiling fan 1200/1400 mm sweep complete all as specified and as directed. |
| 45 | Supply and fixing bearing number of 6201/6202/6203/6204 as required, Make : SKF/NBC or Equivalent |
| 46 | Supply and fixing condenser 2.5 Mfd complete all as specified and as directed. |
| 47 | Supply and fixing condenser 3.15 Mfd complete all as specified and as directed. |
| 48 | Supply and fixing PVC holder for condenser housing complete all as specified and as directed. |
| 49 | Supply and fixing twin core twisted copper flexible wire/cable of size 0.5 sqmm, single core complete all as specified and as directed. |
| 50 | Supply and fixing only gun metal bush complete all as specified and as directed. |
| 51 | Supply and Fix MS ceiling fan shaft suitable for 1200/1400/1500 mm sweep fans, complete all as specified and as directed. |
| 52 | Supply & Fix BLDC Ceiling Fan (1200 mm/1400mm sweep) microcontroller based PCB compatible upto 18 Pole Stator, 90–305V AC Input Voltage with advanced protection features viz. overcurrent, short circuit, and surge protection up to 6kV, Power Rating-28 W to 35 W incl. PCB casing, complete all as specified and directed. |
| 53 | S & F BLDC Ceiling Fan Rotor Magnet Ring upto 18 Pole suitable for Sweep Size 1200 mm to 1400 mm, complete all as specified and directed. |
| 54 | Shifting of existing one light/fan point wiring alongwith LED light fittings after making necessary alteration to path of PVC FRLSH cable encapsulated in caping casing incl. necessary cutting of caping casing-PVC cable set, provisioning of additional caping-casing alongwith accessories for mounting, clips/hooks for mounting LED fittings, etc. complete, all as specified and directed. Please Enable Macros to View BoQ information |