| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/ APAR/Grandly eq. standard make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit, (cutting the wall and making good the same in case of recessed conduit including painting as required with cement plaster, wall putty , paint, complete)with modular switch ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.), modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/Anchor/ APAR/Grandly equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit.(cutting the wall and making good the same in case of recessed conduit including painting as required with cement plaster, wall putty , paint, complete) |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Leiva /ABB Tvisha make make.) |
| 4 | Wiring for lighting circuits/ 6- 10 amp power plugwith 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/Apar/Grandly equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit (cutting the wall and making good the same in case of recessed conduit including painting as required with cement plaster, wall putty , paint, complete) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.) |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/ APAR/Grandly equivalent as directed by engineer incharge.), single core cable in surface/ recessed medium class PVC conduit as required.(cutting the wall and making good the same in case of recessed conduit including painting as required with cement plaster, wall putty , paint, complete) |
| 8 | (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 9 | (a ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | ( b )2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 11 | ( b )4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 12 | (f) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete |
| 14 | Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends. |
| 15 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 16 | Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.) |
| 17 | Sub Head-2 - Fixtures and Fittings |
| 18 | Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium body and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Wipro/Havell/ Helonix make / sample to be approved before installation.. |
| 19 | Supply installation testing and comm. of flood light ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell ( JETA QUANTO PLUS MONO 50 W) /Wipro/Crompton make. |
| 20 | 50 WATT |
| 21 | 100 WATT |
| 22 | S/F testing and comm. Of 20 Watt 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with THD<10%.( commercial series) Philips / Trulux/ wipro/ Havell make/ eq. standard make as directed by engineer incharge. |
| 23 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 3 star rated, ceiling fan ( Atomberg/USHA/Orient /Bajaj/Crompton/equivalent make as directed by engineer incharge,) with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 24 | Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tivsha/schneider Livia /Havell Coral make. |
| 25 | Supply installation testing and comm. Of 200mm -250mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections. |
| 26 | Supply installation testing and comm. Of 400mm sweep exhaust fan Heavy duty industrial type steel body of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections. |
| 27 | Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 28 | 6 way (4 + 24), Double door TPN |
| 29 | 10 way, Double door ( 8+2) SPN |
| 30 | S/F testing and comm. Of MCBs 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABB ./L&T equivalent make as directed by engineer incharge. |
| 31 | a) 6-32 Amp SP MCB |
| 32 | b) 40-63amp DP MCB |
| 33 | c) 40-63amp TPN MCB |
| 34 | Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 35 | Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by8- 10 SWG G.I wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound. |
| 36 | S/L , testing and commissioning of PVC XLPE insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 37 | a)95 sq.mm 3.5 core |
| 38 | b)50 sq.mm 3.5 core |
| 39 | b)16 sq.mm 4 core |
| 40 | Earth work excavation for cable trench, 2 ft deep with an average breadth of 1.5ft and refilling of trench with excavated earth after laying of cable and ramming it properly excluding cost of cable. |
| 41 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 42 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 43 | Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical. Ceasefire/ equivalent make as desired by engineer incharge. |
| 44 | SERVO STABILISER : Supply, installation, testing, and commissioning of 10 kVA servo-controlled automatic voltage stabilizer with a digital microprocessor-based controller, conforming to IS 9815. The stabilizer shall be copper wound (EC grade), oil cooled with minimum 100 litres of insulating oil as per IS 335:2018 (UN type), and of the unbalanced type with a bypass arrangement. It shall operate within an input voltage range of 240–485 V (P-P) and 138.5–380 V (P-N), and provide a stable output voltage of 415 V AC ±1%. The unit shall have an overload capacity of up to 120% and operate at a frequency of 50 Hz with deviation as per IS. It shall include all necessary protection mechanisms as detailed in the technical specifications (Annexure A) and be supplied along with appropriately rated cables on both input and output sides. Make: Hindustan Power Products, PureVolt New Delhi, Jindal electric Faridabad, Servocon, Electric Field, Sen & Pandit Systems, Moto line Electronics, Chinar, Cosco , Power Bank (AMPLE) India, Baid Power Services Pvt ltd. Automatic Electric (AE) ,Fiji Electronics Pvt Ltd |
| 45 | a) 0-500V moving iron type voltmeter with selector switch. |
| 46 | b) A three phase change over switch to read voltage on incoming and output side |
| 47 | c) indicating lights 6 No two numbers for each of the motorised units, one for lower limit and other for higher limit. |
| 48 | d) six push button control for movement operation of three motorised dimmer units two for each unit i.e one for raise operation and one for lower operation under the conditions of adjustment of auto/mannual selector switch (DPDT) |
| 49 | e) Single phase Preventer ( contactor Switch of required rating) Legrand make. |
| 50 | f) six potential meter resistance with lock meter two for each phase control, one for sensitivity and other for level control. |
| 51 | g) two sets of indication lamps three numbers each to indicate output and input indication |
| 52 | h) 20 % over load bearing capacity for one hour. |
| 53 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel , duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) |
| 54 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 55 | Normal INCOMING: |
| 56 | (a) 100 amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make. |
| 57 | b) 4 No. of Aluminium Bus Bar of 200 Amp. |
| 58 | c)Digital meters and phase indicators -1 set. |
| 59 | d) Off load Change over switch 100 Amp for generator.Front operated. |
| 60 | e) 4 No. of Aluminium Bus Bar of 200 Amp. |
| 61 | c)Digital meters and phase indicators -1 set. |
| 62 | Inverter Incommer |
| 63 | (a) 32 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make. |
| 64 | (b) 100 Amp 2 strip bus bar |
| 65 | c)Digital meters and phase indicators -1 set. |
| 66 | OUTGOING: |
| 67 | c) 40-63amp DP MCB |
| 68 | c) 40-63amp TPN MCB |
| 69 | c) space for 16 way MCB's |
| 70 | Supply and errection of 9.0 mt long(410SP-33) steel tubular poles, sawaged type conforming to IS-2713, (Part-II) ,planting depth 1.5 mt .Pole shall have 2 no bolts welded at a distance of 3 mt. from bottom of pole and suitable holes shall be drilled in pole for service connection and lum. earth wires. |
| 71 | Supply and fixing of four arm bracket ( square type 2.5'x2.5') for mounting the luminaire on the top of the pole fabricated out of 75 mm diameter M.S. pipe welded and supported with a triangular MS gasset plate 6mm thick , with a provision of cast iron cap. |
| 72 | Supply and installation of Spiral Earthing through 10 swg GI wire and GI pipe 2ft. after driving in ground up to a depth of 3' in the ground from the base of the pole. |
| 73 | Providing of service connection and earthings to luminaire from the junction box in 1.5 mm PVC insulated, multicolour copper wire . |
| 74 | Painting of pole with one coat of red oxide and two coats of Al. paint. |
| 75 | Erection of metallic pole 8.0 metre and upto 10.0 metre in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation , refilling and concrete jaketing above ground etc. as required. |
| 76 | Supply, installation , testing and commissioning of LED based Flood light, housing made up of pressure die cast aluminum Alloy with effective thermal management,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of greater than 120 lumen/Watt and a minimum system lumen output of 18000 lumens and maximum system wattage of 150 Watts.The fixture shall have a CRI of minimum 70, SDCM<5. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=07 with toughened glass cover.The fixture driver should have an operating voltage range of 140-270 V, inner surge protection of >=4KV, PF >0.95 and THD<10% at full load. Driver should cut off at high voltage of 320volt for safety. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics. Manufacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Philips/ Havell ( Jeta Aris)/ Wipro/ Eq, standard make ( sample to be approved before installation) |
| 77 | S/L , testing and commissioning of, XLPE Insulated, PVC Alluminium un-armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 78 | a) 16 sq.mm 2 core |
| 79 | CCTV System ( Having STQC Compliance) |
| 80 | Supply, Installation, Testing and Commissioning of 4MP IP IR Outdoor Motorized Varifocal Bullet /dome Camera {4MP @25/30fps @1440P (2560×1440) with 2.7 to 4 mm ~12 to 13.5 mm or better Varifocal Motorized lens } having following specifications and features etc:- |
| 81 | Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video |
| 82 | Image Sensor: 1/2.8\\" or better Progressive Scan CMOS, get color image even at night condition (Minimum Illumination: 0.006 Lux @ F1.4, AGC ON, 0 lux with IR or better) |
| 83 | True Day & Night High Performance Mechanical IR cut filter with auto switch |
| 84 | Integrated IR Source (Auto, Manual) – Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night |
| 85 | Imaging: 1/3s to 1/30000s electronic shutter support |
| 86 | Auto Gain Control, White Balance – Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking |
| 87 | Compression (Minimum): Video – H.265 or better, Audio – G.711U/A, G.711Mu, G.726, AAC, G.723 |
| 88 | Wide Dynamic Range: WDR (120 dB or more) |
| 89 | Digital Noise Reduction: DNR (3D) On/Off |
| 90 | Video Streaming & Frame Rates: Triple streaming, configurable Main stream: 4MP (2560×1440) @25/30fps, Sub streams minimum: 720P @25/30fps |
| 91 | Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser |
| 92 | Edge Analytics: Tripwire, Intrusion, Motion Detection |
| 93 | Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade |
| 94 | Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB and shall be supplied with minimum 128GB memory card |
| 95 | Recording Management: Format SD, overwrite, storage management, video to NAS device |
| 96 | Alarm Trigger: Motion/tampering detection, network disconnection detection, IP conflict detection, memory card state detection, memory space detection |
| 97 | Network Protocol: SFTP, IPv6, IPv4, DNS, RTCP, NTP, RTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast |
| 98 | System Capability: ONVIF, Camera shall support open source VMS |
| 99 | Ethernet: 1 RJ45 10/100 Ethernet port |
| 100 | Audio: It should support 1 × Built-In Mic and 1/1 Alarm In/Out for External Mic and Speakers as per site requirement |
| 101 | Power Input: The camera should support simultaneous dual power input – 12 VDC (via power adapter) and PoE (802.3af) to ensure continuous operation in the event of a failure in one power source |
| 102 | Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE |
| 103 | Housing/Enclosure: IP67 weather proof, IK10, Metallic body |
| 104 | Operating Condition: Ambient Temperature: –05°C to 50°C, humidity 95% (max) non-condensing |
| 105 | IR life: 40000 hours or higher |
| 106 | Video Bit rate: 32 KBPS – 8 MBPS or better |
| 107 | Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 108 | The item includes supply of camera, mounting bracket, GI clamps, fasteners, connectors, glands, sealing, alignment, focusing, integration with recording system, testing, commissioning and handing over complete in all respects as required at site. |
| 109 | Supply, Installation, Testing & Commissioning of Outdoor PTZ , 4 MP IP IR motorized PTZ (4MP @25/30fps or better) camera, Triple streaming , configurable on resolution Main stream: 4MP@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.5-135mm or better with Automatic & manual Focus Adjustment provisions, 30x Optical zoom and 12x Digital zoom with angle of viewH : 57˚–2.4˚, m, PAN Travel: Pan: 0° ~ 360° endless; Manual Pan: 300° /s, Preset : 300° /s, Tilt Travel: Tilt: 0-90°, auto flip 180°, Manual Tilt: 200° /s, Preset : 300° /s conforming to the following minimum specifications: |
| 110 | IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR |
| 111 | Image Sensor: 1/2.8\\" or better Progressive Scan CMOS |
| 112 | Signal System: PAL/NTSC |
| 113 | Minimum Illumination: 0.008 Lux @ F1.6, AGC ON, 0 lux with IR, or better |
| 114 | Imaging: 1/1s to 1/30000s, Auto Gain Control, White Balance – Auto, Back Light Compensation, Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features |
| 115 | On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both |
| 116 | Signal to Noise Ratio: >50 dB |
| 117 | Event Notification: Through Relays, E-Mails or FTP |
| 118 | Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source Inbuilt IR LED's with effective distance. The camera should have IR LED’s and cover distance up to 300 meter or above |
| 119 | Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it |
| 120 | Pre/Post Event Buffering: The camera should support atleast 5 seconds of pre & post event buffering |
| 121 | Presets: 300 Presets |
| 122 | Video Compression (Minimum): H.265 or better, H.264 |
| 123 | Audio Compression: G.711U/A, G.711Mu, G.726, AAC, G.723 |
| 124 | Wide Dynamic Range: WDR (120 dB or more), HLC & BLC |
| 125 | Digital Noise Reduction: DNR (2D+3D) On/Off |
| 126 | Image Setting: Rotate Mode, ROI, EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser |
| 127 | Profile Management: User configuration import, export |
| 128 | Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution |
| 129 | Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB and shall be supplied with minimum 128GB memory |
| 130 | Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login |
| 131 | Edge based Video Analytics & Alarm Trigger: Motion/tampering detection, network disconnection detection, IP conflict detection, memory card state detection, memory space detection, Tripwire, Intrusion, Object Abandon/Missing, SMD, Face Detection |
| 132 | Network Protocol: SFTP, IPv6, IPv4, DNS, NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS |
| 133 | System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & credentials should be valid on the date of technical evaluation) |
| 134 | VMS: Camera shall support open source VMS |
| 135 | Connectivity: 1 × LAN RJ-45 (10/100Base-T) |
| 136 | Audio Support: Audio Interface – The camera should have 1/1 Audio In/Out to connect External Mic and Speaker |
| 137 | Audio Compression: PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2, G.722.1 |
| 138 | Alarm In/Out: 7/2 Ch In/Out |
| 139 | Power Input: The camera should support simultaneous dual power input – DC/AC (via power adapter) and PoE (802.3af) to ensure continuous operation in the event of a failure in one power source |
| 140 | Power Requirement: 24 VDC, 2.5 A (±25%), PoE+ (802.3at) |
| 141 | Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection |
| 142 | Operating Condition: Ambient Temperature: –05°C to 50°C, humidity 95% (max) non-condensing |
| 143 | IR life: 40000 hours or higher |
| 144 | Video Bit rate: 32 KBPS – 8 MBPS or better |
| 145 | Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 146 | The item includes supply of PTZ camera, wall/pole mount bracket, GI clamps, connectors, glands, sealing, alignment, programming of presets, integration with recording system, testing, commissioning and handing over complete in all respects as required at site. |
| 147 | Managed Gigabit Ethernet PoE network switch : Supply, installation, testing and commissioning of Layer-2 managed Gigabit Ethernet PoE network switch suitable for IP CCTV surveillance system complete in all respects conforming to the following minimum specifications: |
| 148 | 24 × 10/100/1000 Mbps RJ45 PoE ports |
| 149 | Minimum 2 × Gigabit SFP uplink ports for optical fiber connectivity |
| 150 | PoE standard IEEE 802.3af/at with minimum total PoE power budget 370 W or higher |
| 151 | Non-blocking switching capacity suitable for full port load operation |
| 152 | MAC address table ≥ 8K entries |
| 153 | VLAN support (802.1Q), port isolation and loop prevention |
| 154 | QoS, bandwidth control and IGMP snooping for video traffic optimization |
| 155 | STP/RSTP network redundancy support |
| 156 | Web based and CLI management interface |
| 157 | Surge and lightning protection on all ports |
| 158 | Rack mountable metal enclosure with internal power supply |
| 159 | Operating temperature –10°C to +55°C or better |
| 160 | Compatible with IP cameras, NVR and optical fiber SFP modules |
| 161 | The item includes supply of switch, rack mounting, configuration, IP addressing, integration with cameras/NVR, testing, commissioning and handing over complete in all respects as required at site. |
| 162 | Network Video Recorder : Supply, installation, testing and commissioning of standalone embedded Network Video Recorder suitable for IP based CCTV surveillance system complete in all respects conforming to the following minimum specifications: |
| 163 | 16 channel IP camera input support |
| 164 | Recording resolution up to 4MP/5MP or higher per channel |
| 165 | Video compression H.265+/H.265/H.264 |
| 166 | Minimum incoming bandwidth 160 Mbps or higher |
| 167 | HDMI & VGA simultaneous video output |
| 168 | Minimum 2 SATA ports supporting surveillance hard disk (8TB or higher each) |
| 169 | Live view, recording, playback, backup and remote monitoring capability |
| 170 | Motion detection, event recording and alert notification support |
| 171 | Gigabit Ethernet network interface |
| 172 | USB ports for backup and mouse control |
| 173 | Compatible with ONVIF compliant IP cameras and PTZ control through network |
| 174 | Mobile viewing and CMS software support |
| 175 | The item includes supply of NVR, installation in rack, configuration, camera integration, recording setup, testing, commissioning and handing over complete in all respects as required at site. |
| 176 | Hard Disk Drive : Supply, installation, testing and commissioning of surveillance grade Hard Disk Drive suitable for continuous CCTV recording complete in all respects conforming to the following minimum specifications: |
| 177 | Storage capacity: 8 Terabyte |
| 178 | Form factor: 3.5 inch |
| 179 | SATA Interface: SATA III (6 Gb/s) or higher |
| 180 | Designed for 24×7 surveillance operation |
| 181 | Workload rating suitable for video recording (minimum 180 TB/year or better) |
| 182 | Optimized for multi-camera streaming and NVR applications |
| 183 | Rotational speed 5400/7200 RPM with cache buffer ≥ 256 MB |
| 184 | Support for simultaneous recording from multiple HD cameras |
| 185 | Low power consumption and heat optimized for rack mounted recorders |
| 186 | Compatible with standard CCTV NVR systems |
| 187 | The item includes supply of HDD, installation inside NVR, formatting, recording configuration, testing and commissioning complete in all respects as required at site. |
| 188 | LED display monitor : Supply, installation, testing and commissioning of 42 inch LED display monitor suitable for CCTV surveillance monitoring complete in all respects conforming to the following minimum specifications: |
| 189 | Screen size: 42 inch LED backlit display |
| 190 | Full HD resolution 1920 × 1080 or higher |
| 191 | Aspect ratio 16:9 wide screen |
| 192 | Brightness minimum 250 cd/m² or better |
| 193 | Viewing angle ≥ 170° |
| 194 | Refresh rate 60 Hz or higher |
| 195 | Inputs: HDMI, VGA and audio support |
| 196 | Continuous 24×7 operation suitable for surveillance monitoring |
| 197 | Low power consumption and wall/desk mountable design |
| 198 | Compatible with NVR and computer workstation display output |
| 199 | The item includes supply of monitor, power cord, mounting arrangement, connection with NVR/workstation, testing, commissioning and handing over complete in all respects as required at site. |
| 200 | UPS system : Supply, installation, testing and commissioning of true online double conversion UPS system suitable for CCTV control room equipment complete in all respects conforming to the following minimum specifications: |
| 201 | Capacity: 2 KVA / 1600 W or higher |
| 202 | Technology: True online double conversion |
| 203 | Input voltage range: 160–300 V AC or wider |
| 204 | Output voltage: 230 V AC ±1% pure sine wave |
| 205 | Output frequency: 50 Hz ±0.5% |
| 206 | Efficiency ≥ 90% in normal mode |
| 207 | Overload, short circuit and surge protection |
| 208 | LCD display for load, battery status and fault indication |
| 209 | Automatic bypass facility |
| 210 | Intelligent battery management with deep discharge protection |
| 211 | External SMF tubular/VRLA battery bank providing minimum 2 hours backup for connected load |
| 212 | Audible and visual alarms |
| 213 | The item includes supply of UPS, battery bank, interconnecting cables, earthing, installation, charging, load testing, commissioning and handing over complete in all respects as required at site. |
| 214 | 19\\" Racks : Supply, installation, testing and commissioning of 19” floor standing equipment rack suitable for housing CCTV networking and recording equipment complete in all respects conforming to the following minimum specifications: |
| 215 | 9 U standard 19 inch rack mount enclosure |
| 216 | Heavy duty CRCA steel construction with powder coated finish |
| 217 | Front toughened glass lockable door and rear metal lockable door |
| 218 | Removable side panels with locking arrangement |
| 219 | Ventilation fan units with air vents for heat dissipation |
| 220 | Adjustable mounting rails for equipment installation |
| 221 | Cable entry provision from top and bottom with gland plates |
| 222 | Earthing stud with earthing wire |
| 223 | Power Distribution Unit (PDU) with minimum 6 universal sockets |
| 224 | Suitable for installation of NVR, switches, LIU and other accessories |
| 225 | The item includes supply of rack, PDU, fan units, mounting hardware, installation of equipment inside rack, cable dressing, earthing, testing, commissioning and handing over complete in all respects as required at site. |
| 226 | Octagonal pole : Supply, erection, testing and commissioning of hot dip galvanized octagonal pole suitable for mounting CCTV cameras complete in all respects conforming to the following specifications: |
| 227 | Height: 9 meter above ground level |
| 228 | Construction: Octagonal tapered pole made from sheet steel, continuously welded |
| 229 | Galvanization: Hot dip galvanized as per relevant standards (minimum 70 micron coating or better) |
| 230 | Base plate: Suitable thick MS base plate with anchor bolt arrangement |
| 231 | Foundation: RCC foundation including excavation, PCC bed, reinforcement, concreting and curing complete |
| 232 | Anchor bolts: Minimum 4 Nos high tensile foundation bolts with nuts and washers |
| 233 | Cable entry provision inside pole with inspection door |
| 234 | Camera mounting brackets and clamps provided at top |
| 235 | Earthing arrangement connected to pole body |
| 236 | Two coats of synthetic enamel paint over primer (if required over GI surface markings) |
| 237 | The item includes supply of pole, transportation, excavation, foundation concrete, erection, alignment, grouting, painting, mounting of camera brackets, earthing, testing and handing over complete in all respects as required at site. |
| 238 | Power cable: Supply, laying, testing and commissioning of 3 core × 2.5 sqmm copper conductor un-armoured power cable suitable for outdoor electrical supply to CCTV equipment complete in all respects conforming to the following specifications: |
| 239 | Conductor: Stranded annealed copper conductor |
| 240 | Size: 3 Core × 2.5 sqmm |
| 241 | Insulation: XLPE insulated |
| 242 | Sheathing: PVC inner & outer sheath |
| 243 | Voltage grade: 1.1 kV |
| 244 | Conforming to relevant IS standards |
| 245 | Suitable for underground / surface / conduit laying |
| 246 | Including laying in trench/pipe/wall, dressing on poles, clamping with saddles, termination using brass glands and lugs, ferruling, insulation testing with megger and identification at both ends |
| 247 | The item includes supply of cable, accessories, termination, testing, commissioning and handing over complete in all respects as required at site. |
| 248 | Surge protection device : Supply, installation, testing and commissioning of modular type surge protection device suitable for protection of CCTV equipment against lightning and transient over-voltage complete in all respects conforming to the following minimum specifications: |
| 249 | Type-2 SPD suitable for single phase 230 V AC supply |
| 250 | Nominal discharge current (In) ≥ 5 kA and maximum discharge current (Imax) ≥ 10–20 kA or better |
| 251 | Voltage protection level suitable for electronic equipment |
| 252 | DIN rail mounted modular design |
| 253 | Visual indication for healthy/fault status |
| 254 | Replaceable protection cartridge |
| 255 | Suitable for installation inside distribution board / control panel |
| 256 | Conforming to relevant IEC/IS standards |
| 257 | Including connection with phase, neutral and earth, proper earthing termination, testing and commissioning complete |
| 258 | The item includes supply of SPD, mounting, wiring, testing and handing over complete in all respects as required at site. |
| 259 | CAT 6 LAN Cable : Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed Steel/PVC conduit as required. 1 run of cable. |
| 260 | Supply of factory made Cat6 Patch cords (1-3)m : The Cat 6 patch cords shall be factory manufactured, tested, and certified for use in high-speed data transmission networks, conforming to ANSI/TIA-568.2-D and ISO/IEC 11801 standards for Category 6 performance. The patch cords shall consist of 4-pair 24 AWG stranded copper conductors with high-quality insulation and outer sheath made of PVC or LSZH (Low Smoke Zero Halogen), suitable for indoor applications. They shall support data transmission up to 1 Gbps with a bandwidth of 250 MHz, ensuring low insertion loss, minimal return loss, and controlled crosstalk (NEXT, FEXT) within specified limits. Each patch cord shall be terminated at both ends with factory-moulded RJ45 connectors (8P8C) with 50-micron gold-plated contacts to ensure reliable connectivity, durability, and resistance to corrosion. The connectors shall be provided with snagless or moulded strain relief boots to prevent cable damage and facilitate easy insertion and removal. The patch cords shall be wired as per T568A or T568B standards with proper pair twisting maintained up to the termination point. The cords shall be available in various standard lengths (e.g., 0.5 m, 1 m, 2 m, 3 m, etc.) and color-coded for easy identification and cable management. They shall be 100% factory tested for continuity, wire mapping, and performance parameters, and shall comply with RoHS standards |
| 261 | 1 Mtr |
| 262 | 3 Mtr |
| 263 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 264 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 265 | 63 mm dia (OD-63 mm & ID-51 mm nominal) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail