| 1 | Earth work in excavation of foundation trenches in ordinary soil except sheet rock and boulders (requiring blasting) including dressing and leveling the bed upto the required depth and depositing the excavated materials away form the site with all leads and lifts. T & P shoring and shuttering if required etc. complete as directed by engineer- in charge. |
| 2 | Supplying and filling in foundation and ditches with sand well watered and rammed in layers not exceeding 23 cm in depth with all lead and lift including cost, conveyance, loading and unloading , royalties and taxes of all materials and cost of all labour, sundries. T & P required for the work etc complete in all respect as per direction of Engineer incharge. |
| 3 | Providing & laying plain cement concrete 1:3:6 ( 1 cement 3 coarse and 6 graded stone aggregate fo 40 mm nominal size) in foundation and pinth including cost of hoisting, lowering laying concrete, ramming , watering and curing etc. complete to required levels laid in layers not exceeding 15cm thick including cost. Conveyance, loading and unloading, royalties and taxes all materials and cost of all labours, sundnes, T & P required for the work complete including dewatering if required as epr instruciton of Engineer-in- charge. |
| 4 | i. Providing , lifting hoisting laying Reinforced cement concrete of M20 grade in column footings , as per approved designs and drawings having a munimum compressive strength ( in work test) 200 Kg./ Square cm in 15cm. Cubes at 28 days after mixing and tests conducted in accordance with I.S. 416 using 12mm to 20 mm size black hard crusher broken granite stone ships of approved quality from approved quarry washed and cleaned (20mm size not to exceeds 25%) to be mixed in concrete mixture with ordinary protland cement (OPC) including noisting, lowering lying an dcompacting concrete by susing vibrators, watering and curing for 28 days centering and shuttering and finishing the exposed surface smooth proving grooves or beads wherever necessary including cost conveyance, loading and unloading royalities and taxes of all materials and cost of all labours sunones , T & P required fo rthe work ect complete in all respect excluding cost and conveyance of HYSD/MS steel and binding wires , and labour charges for straightaining, cutting , bending etc of M.S. rods of for steel and binding (a) Column Footing |
| 5 | (b) Column upto pinth |
| 6 | c. Plinth beam |
| 7 | Cold twisted steel reinforcemtn for RCC work including cutting bendingstragntening and binding with 18swg black annealed wire and placing in posting complete. |
| 8 | R R stone masonry (1:6) cement mortar for foundation and plinth. |
| 9 | GROUND FLOOR:Providing, lifting, hoisting laying Reinforced cement concrete of M20grade in column footings s per approved designs and drawings having a minimum compressive strength ( in work test) 200 kg/Square cm. in 15 cm cubes at 28 days afterr mixing and tests conducted in accordance with I.S. 416 using 12 mm to 20 mm size black hard crusher broken grantie stone chips of approved quality from approved quarry washed and cleaned (20 mm size not to exceeds 25%) to be mixed in concrete mixure with ordinary portland cement (OPC) includin ghosting, lowering, lying and compacting concrete by using vibrators, watering andcuring for 28 days centering and shuttering and finishing the xposed surface mooth providing grooves of beads wherever necessary including cost. conveyance, loading and unloading , royaliies and teaxes of all materials and cost of all labours , sundries , T &P, required for the work etc. complete in all respect excluding cost and conveyance of HYSD/Ms steel and binding wires and labour charges for straihtaining, cutting, bending etc. of M.S rods of for steel and binding wires and lying the grils and placing in poper postion.A) COLUMN |
| 10 | B) LINTEL BAND |
| 11 | C) ROOF BEAM |
| 12 | D) CHHAJJA |
| 13 | E) ROOF SLAB |
| 14 | F) STAIRCASE |
| 15 | Cold twisted steel reinforcement for RCC work including cutting bending straihtening and binding with 18swg black annealed wire and placing in position complete |
| 16 | Well burnt first class brick masonry using Fly ash bricks having crushing strength not less than 75 kg per squr.cm. in cement mortar of (1:6) with portland slag cement after immersing the bricks for 6 (six) hours in water before use in superstructure similar such type of works with all necessary projections, watering and curing etc. including cost, conveyance, loading and unloading, royalitioes and taxes of all materials and cost of all labour, sundries, T & P required for the works etc complete in all respect as directed by the Engineer-in-charge. A) 230mm thich brick v. all |
| 17 | B) 115mm thick brick wall with (1:4) cement mortar. |
| 18 | Providing and laying 12mm cement plaster (1:6) to out side after cleaning the surface taking out point including cost of all materials labour cutting taxes etc. complete as per instruction of architect/ Engineer incharge. |
| 19 | Providing and laying 16mm cement plaster (1:6) over brick work to inside walls after cleaning the surface taking out point including cost of all materials labour cutting taxes etc. complete as per instruction of architect/ Engineer incharge. |
| 20 | Finishign walls with water proofing distemper of approved shade on new work 2 coats to give an even shade inclduing cost of brushes and putty inclduing cost of paint( per one Sq. Mtr)(for inside) |
| 21 | Finishign walls with water proofing weather coate of approved shade on new work 2 coats to give an even shade inclduing cost of brushes and putty inclduing cost of paint( per one Sq. Mtr)(for inside) |
| 22 | Providing and painting two coats of synthetic enamel paints over a coat of primer to steel work including sand papering, scaffolding , cost of conveyance, taxes of all materials. T & P labour required to complete the work as per design/ drawing & instruction of Architect/ Engineer-in- charge. |
| 23 | Fixing tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete excluding cost of precast TILES. |
| 24 | Providng fitting and fixing of M.S.Door/ window frame with integrated grill shutter as per the following design and specificaiton. |
| 25 | Supplying, fitting, fixing up window (sliding type) made up aluminum Section 151-154, 151-155, as windows frame section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc.complete as per direction of Engineer-incharge |
| 26 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railling using 50mm dia of 32mm x 32mm x 2mm @ 0.90mtr C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm 3 rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour etc required for the work complete in all respect.Data for 3.26 rm |
| 27 | Fixing tiles in dados skrting on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tile. |
| 28 | Fixing ceramic tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete excluding cost of precast TILES. |
| 29 | FIRST FLOOR:Providing, lifting, hoisting laying Reinforced cement concrete of M20grade in column footings s per approved designs and drawings having a minimum compressive strength ( in work test) 200 kg/Square cm. in 15 cm cubes at 28 days afterr mixing and tests conducted in accordance with I.S. 416 using 12 mm to 20 mm size black hard crusher broken grantie stone chips of approved quality from approved quarry washed and cleaned (20 mm size not to exceeds 25%) to be mixed in concrete mixure with ordinary portland cement (OPC) includin ghosting, lowering, lying and compacting concrete by using vibrators, watering andcuring for 28 days centering and shuttering and finishing the xposed surface mooth providing grooves of beads wherever necessary including cost. conveyance, loading and unloading , royaliies and teaxes of all materials and cost of all labours , sundries , T &P, required for the work etc. complete in all respect excluding cost and conveyance of HYSD/Ms steel and binding wires and labour charges for straihtaining, cutting, bending etc. of M.S rods of for steel and binding wires and lying the grils and placing in poper postion.A) COLUMN |
| 30 | B) LINTEL BAND |
| 31 | C) ROOF BEAM |
| 32 | D) CHHAJJA |
| 33 | E) ROOF SLAB |
| 34 | F) STAIRCASE |
| 35 | Cold twisted steel reinforcement for RCC work including cutting bending straihtening and binding with 18swg black annealed wire and placing in position complete |
| 36 | Well burnt first class brick masonry using Fly ash bricks having crushing strength not less than 75 kg per squr.cm. in cement mortar of (1:6) with portland slag cement after immersing the bricks for 6 (six) hours in water before use in superstructure similar such type of works with all necessary projections, watering and curing etc. including cost, conveyance, loading and unloading, royalitioes and taxes of all materials and cost of all labour, sundries, T & P required for the works etc complete in all respect as directed by the Engineer-in-charge. A) 230mm thich brick v. all |
| 37 | B) 115mm thick brick wall with (1:4) cement mortar. |
| 38 | Providing and laying 12mm cement plaster (1:6) to out side after cleaning the surface taking out point including cost of all materials labour cutting taxes etc. complete as per instruction of architect/ Engineer incharge. |
| 39 | Providing and laying 16mm cement plaster (1:6) over brick work to inside walls after cleaning the surface taking out point including cost of all materials labour cutting taxes etc. complete as per instruction of architect/ Engineer incharge. |
| 40 | Finishign walls with water proofing wether coate of approved shade on new work 2 coats to give an even shade inclduing cost of brushes and putty inclduing cost of paint( per one Sq. Mtr)(for inside) |
| 41 | Providng fitting and fixing of M.S.Door/ window frame with integrated grill shutter as per the following design and specificaiton. |
| 42 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railling using 50mm dia of 32mm x 32mm x 2mm @ 0.90mtr C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm 3 rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour etc required for the work complete in all respect.Data for 3.26 rm |
| 43 | providing painting two coat of distemper of approved shade to walls and ceiling surface includng all taxes cost of labour etc. complete as epr drawing , design and insruction of EIC.(In side) |
| 44 | Providing and painting two coats of synthetic enamel paints over a coat of primer to steel work including sand papering, scaffolding , cost of conveyance, taxes of all materials. T & P labour required to complete the work as per design/ drawing & instruction of Architect/ Engineer-in- charge. |
| 45 | 20mm thick grading plaster (1:4) over slab including cost conveyance of all materials and labour etc. complete as per the specification for FG/FF |
| 46 | Fixing tiles in dados skrting on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tile. |
| 47 | Fixing ceramic tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment o match the shades of the tiles including rubbing and polishing complete excluding cost of precast TILES. |
| 48 | Rain water down pipe including fitting fixing cost of 100mm pipe and bend etc |
| 49 | FIRST FLOOR:Providing, lifting, hoisting laying Reinforced cement concrete of M20grade in column footings s per approved designs and drawings having a minimum compressive strength ( in work test) 200 kg/Square cm. in 15 cm cubes at 28 days afterr mixing and tests conducted in accordance with I.S. 416 using 12 mm to 20 mm size black hard crusher broken grantie stone chips of approved quality from approved quarry washed and cleaned (20 mm size not to exceeds 25%) to be mixed in concrete mixure with ordinary portland cement (OPC) includin ghosting, lowering, lying and compacting concrete by using vibrators, watering andcuring for 28 days centering and shuttering and finishing the xposed surface mooth providing grooves of beads wherever necessary including cost. conveyance, loading and unloading , royaliies and teaxes of all materials and cost of all labours , sundries , T &P, required for the work etc. complete in all respect excluding cost and conveyance of HYSD/Ms steel and binding wires and labour charges for straihtaining, cutting, bending etc. of M.S rods of for steel and binding wires and lying the grils and placing in poper postion.A) COLUMN |
| 50 | C) ROOF BEAM |
| 51 | E) ROOF SLAB |
| 52 | Cold twisted steel reinforcement for RCC work including cutting bending straihtening and binding with 18swg black annealed wire and placing in position complete |
| 53 | Well burnt first class brick masonry using KB bricks having crushing strength not less than 75 kg per squr.cm. in cement mortar of (1:4)1:6) with portland slag cement after immersing the bricks for 6 (six) hours in water before use in superstructure similar such type of works with all necessary projections, watering and curing etc. including cost, conveyance, loading and unloading, royalitioes and taxes of all materials and cost of all labour, sundries, T & P required for the works etc complete in all respect as directed by the Engineer-in-charge. 250mm thick brick v. all |
| 54 | Providing and laying 12mm cement plaster (1:6) to out side after cleaning the surface taking out point including cost of all materials labour cutting taxes etc. complete as per instruction of architect/ Engineer incharge. |
| 55 | Providing and laying 16mm cement plaster (1:6) over brick work to inside walls after cleaning the surface taking out point including cost of all materials labour cutting taxes etc. complete as per instruction of architect/ Engineer incharge. |
| 56 | providing painting two coat of distemper of approved shade to walls and ceiling surface includng all taxes cost of labour etc. complete as epr drawing , design and insruction of EIC.(In side) |
| 57 | Providing fitting and fixing of M.S Door & window frame with integrated grill shutter as per approved design and specification. |
| 58 | providing painting two coat of weather coate of approved shade to walls and ceiling surface includng all taxes cost of labour etc. complete as epr drawing , design and insruction of EIC.(In side) |
| 59 | Providing and painting two coats of synthetic enamel paints over a coat of primer to steel work including sand papering, scaffolding , cost of conveyance, taxes of all materials. T & P labour required to complete the work as per design/ drawing & instruct |
| 60 | 20mm thick grading plaster (1:4) over slab including cost conveyance of all materials and labour etc. complete as per the specification for FG/FF |
| 61 | Supplying , fitting , fixing of water closet of CERA make 2073 Orissa Pan(Cello) of size 510 x 400 mm or equivalent of Parryware/ Hindware , duly embedded in cement concrete(1:3:6) using 12mm size b.h.g chips all complete with materials , albour and T& P etc. |
| 62 | Supplying , fitting , fixing of porcelein wash hand basin of size 450mm x 350 mm of CERA make, catalogue no Canon 1012 Wash Basin of Equivalent of Parryware/ Hindware with rog bolts, CI brackets, hole for pillar cock with cast iron/ M.S. brackets painted while including cutting holes in wall and making good to the damages etc. all complete with materials , labour and T& P etc. |
| 63 | Supply , fitting , fixing of ( 500 x 450 mm) bevelled edge mirror of superior glass mounted on 6 mm thk A.C. sheet or ply-wood sheet and fixed to wooden plugs with cromium plated brass screws and washers etc. all complete with materials , labour and T & P etc. |
| 64 | Providing and fixing PVC soil waste and vent pipes 110 mm dia. |
| 65 | Supplying fitting , fixing of cost ( Spun) iron floor traps of the following norminal diameter of outlet of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm including cutting holes in walls and making good to the damages etc. all complete with materials, labour and T& P etc. |
| 66 | Providing and fixing PVC plain bend of required degree 100mm dia. |
| 67 | Providing and fixing PVC single equal plain junction of required degee with access door, insertion rubber washer 3mm thick, bolts and nuts complete .(1000x100x100mm) |
| 68 | Providing and fixing door piece, insertion rubber washer 3mm thick , bolts & nuts complete . 100mm dia. |
| 69 | Providing & fixing PVC terminal guard (i) 100 mm |
| 70 | Supplying, fitting, fixing to walls, ceiling and floor upplasticized PVC pipes conforming to I.S. 4985 of class IV ( 10 kg/ cm 2) th efollowing nominal diameter with fittings and clamps includings testing all complete with materials labour and T & P etc.a) 15mm dia nominal bore |
| 71 | b) 20mm dia nominal bore |
| 72 | c) 25 mm dia nominal bore |
| 73 | d) 32 mm dia nominal bore |
| 74 | Providing and fioxing brass bib cock of approved quality .(i) 15mm nominal bore short body |
| 75 | (ii) 15mm nominal bore long body |
| 76 | Providing and fixing brass stop cock with wall flush of approved quality . 15mm nominal bore. |
| 77 | Providing and fixing gun metal gate valve with C.I. wheel of approved qualioty ( screwed end)(i) 25 mm dia Nominal bore |
| 78 | (ii) 32 mm dia Nominal bore |
| 79 | (iii) 15mm dia Nominal bore |
| 80 | Supplying fiting , fixing of S.W. Gully trap Grade-A complete with cast iron grating, brick masonry chamber( 250 mm x 250 mm) with R.C.C cover slab as per P.H. specificaiton and design all complete with materials labour and T & P etc. (Excluding cost of gully trap and grating) |
| 81 | Supply all labour , materials and T & P and laying to level and slope and jointing with cement mortar(1:1) for salt glazed stone were pipes . (Grade-A) of the following diametersas per specification al complete (excluding earth work in trenches)(data for 30 mtr.) (per mtr) S.W. Pipe 150mm dia. |
| 82 | Supplying all materials, labour and T & P for construction of inspection chamber as per P.H. specification and design all ocmplete ( per each) |
| 83 | Supplying, fitting fixing or constructing of 1.20 mtr dia x 2.55 mtr.Deepsoak-way pit with dry brick walling up to2.10mtr. Height and brick work with cment mortar(1:6) for 0.45mtr height of wall at top, cement plaste(1:3)inside and ouside, inside filled with dry brick khoa of 50mm to 100 mm size to a height of 2.00 mtr form bottom. covered by means of 40mm thick R.C.C perforated slat 50 mm thick RCC. Well cover in pieces fitted with iron rings including earth work in excavation and refiling of cavity around the pit etc all complete as per approved design and drawing ( Per each) |
| 84 | providing and placing on terrance (at all floor levels) per liter polyethylene water storage tank ISI:12701 marked capacite indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for intel, outlet and overflow pipes but without fittings and the base support for tank ( sintex, Electroplast, star Lots of equivalent having valid ISI license) |
| 85 | SEPTIC TANKEarth work in all kinds of hard soil within 50mtrs initial lead and 1.5 mtrs intial lift including rough dressing and leveling the bed and breaking clods to maximum 5cm to 7 cm and laying in layers not exceeding 0.3mtrs depth and as per the direction of the Engineer -in-charge. |
| 86 | Providing and laying plain cement concrete 1:4:8 in foundation and bottom layers of the lank using 40mm size black hare crusher broken ganite metal of conveyance , royality , all taxes complete and providing to proper thickness. Watering and curing for the requied period as per direction fo Engineer- in Charge. |
| 87 | Providing plain cement concrete 1:2:4 with 12 mm size hard black granite crusher broken chips of approved quality from the approved quarry including all labour and T& P for mixing, lifting, lowering, laying and compacting to proper shape & size and finishing the exposed surface smooth with neat cement punning including the cost of scaffolding watering and curing for the required period as per the direction fo Enginer-in charge including cost, conveyance royality, taxes etc of all the materials and labour complete |
| 88 | Brick (230 mm size) masonary work using CB. Bricks having crushing strength between 75 kg to 99 kg/ sqcm. In cement mortar(1:6) duly immersing the bricks for minimum period of six hours in water before use in foundaiton and plinth including cost, conveyance taxes, royalitites, laoding and unloading of all materials and labour and scaffolding , wateirng, curing T& P etc. complete as per the direction fo the Engineer - in charge. |
| 89 | Providign , lifting hoisting and laying reinforced cement concrete 1:1, 5:3 with 20 mm crusher broken black H.g. graded chips of approved quality from approved quarry including mixing and compacting to proper shape & size and finishing th eexposed surface smooth with scaffolding , watering and curing for the required period as per the direction of the Engineer- in- charge including all materials cos,t conveyancy, taxes royalities, loading unloading, labour T & P etc. all complete but excluding the cost of steel and centering / shuttering etc. |
| 90 | Providing fixing HYSD reinforcement bars for R.C.C. works of required diameter and approved qualioty with straightening, cutting to sizes bendign & binding, typing the grills and placing in position using binding wire( 18 to 20 gauge) including cost of all labour, material sunderes T & P scaffolding etc. all complete as per specificaiton and the direction of Engineer - in charge. |
| 91 | Providing 12mm thick cement plaster with cement mortar( 1:4) including cement punning finishing smooth over brick work of the septic tank with waterproofing cemen tbased compound of approved quality including laying finishign smooth to proper slope and plane as per the direction fo Engineer- in charge. including cost of all materials with conveyance, royality , taxes watering and curing all labour and T& P etc. complete. |
| 92 | Providing lifting and fixing of 450 mm dia C.I. man hole cover with suitable frome with finished cost of all materisl, labours and T& P etc. complete as per the direction fo the Engineer- in charge. |
| 93 | Providing fitting and fioxing of 250 mm S.W tee with 250 mm dia RCC pipe at inlet and outlet of the septic tank inclusive of all labour , T& P sundries, fittings etc as per the direction fo the Engineer- in charge complete |
| 94 | Providing fixing and fitting CL step iron ofapproved qualty and size with three coats of anticorrosive paint at regular intervals inside the tank incuding cost, conveyance, taxes all comlete and as per the direction of the Engineer - in charge. |
| 95 | Providing and fixing of 50 mm dia HCL pipe and cowl form vent on the two part of the eptic tank including painting three coats with anticorrosive paint all cost, coveyance, taxes etc all complete as per the direction of the Engineer- in charge. |
| 96 | Recessed wiring to Light point/Exhaust Fan Point with 1.5 sqmm, FR PVC Insulated single core multistrand copper conductor of ISI marked with 20 mm dia non- metallic PVC flexible conduct with 5 Amp, 250 V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor and earth wire incouding all accessories and connection as per direction of engineer in charge (Make of wire = Finolex/L&T/ Anchor/ V-Guard) deducting the cost of 2M Box with cover Plate-1 No.)Group A 1.2.1-1.24.2 |
| 97 | -do-………Group B 1.2.2 - 1.24.2 |
| 98 | -do-………. Group C 1.2.3 - 1.24.2 |
| 99 | Recessed wiring to Fan point in Group B 1.2.2 - 1.24.2 |
| 100 | -do-………. Group C 1.2.3 - 1.24.2 |
| 101 | Recessed wiring to Callbell point in Group C 1.2.3 - 1.24.2 |
| 102 | S/F of Extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required. |
| 103 | S/F of 5/6 Modular Switch & 3pin 5/6A Modular Socket on existing board (1.25.1+1.25.4) |
| 104 | S/F of 15/16A FT power plug and Socket Modular type Accessories(1.27) |
| 105 | S/F to 16/18 SWG Modular GI box of following sizes (normal sixe) in recess with suitable size of Modular Base & Cover in front including cutting the wall and making good the same in case of recessed conduit as required.for 2 Module(1.24.1) |
| 106 | ..do 4 Module |
| 107 | -do-6 Module |
| 108 | -do-8 Module |
| 109 | -do-12 Module |
| 110 | -do-18 Module |
| 111 | Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Finolex/L&T/Anchor/Havels/V-Guard).2x1.5 sqmm + 1 x 1.5 sqmm( 1 .8) |
| 112 | -do- 2 x 2.5 sqmm + 1 x 1.5 sqmm (1.8.2) |
| 113 | -do- 2x4 sqmm + 1 x 1.5 sqmm (1.8.3) |
| 114 | 4x4+2x2.5(1:8:9) |
| 115 | Inverter wiring (1x1.5smm) Copper wire (1.19.1) |
| 116 | S/F of 5 to 32 Amp rating 240 Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution Board ISI marked complete with connection, testing and commissioning etc. as required (2.6.1) |
| 117 | S/F of 'B/C/D' series DP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the 2 Way double door MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)+(2.3.1b) |
| 118 | 6 way Double door (2.3.6) |
| 119 | S/F of 4 way (4+12) TPN MCB DB double door (2.5.5) |
| 120 | S/F of batten holder BK angle holder ISI marked including connection etc. instead of ceiling rose(1.29- 1.28) |
| 121 | S/F of 9W LED Bulb |
| 122 | Earthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2) |
| 123 | Supply andlaying 8 SWG copper wire in recess for loop earthing as required (3.18) |
| 124 | Supply and fixing of 1200mm A.C. Ceiling fan (5 star) 28 watt BLDC with all accessories and connections with out fan regulator (Make:Usha-Techinix ISI /Crompton- Energion Groove/Havells-Efficiencia Neo/ Anchor- Eco Breeze Urban/Orient-Eco Tech Supreme/ Pollycab -Affeciente Neo ) |
| 125 | S/F step type modular fan regulator |
| 126 | S/F of Fan hook S, Type on ceiling.(M-22) |
| 127 | S/F of 18-25 watt LED Tube light fitting including necessary connection, Make-( Crompton/HPL/Polycab/Havells/PAC) |
| 128 | Supply, Installation, Testing and commissionioning of 225mm sweep exhaust fan in the existing opening, including making the hole to suit the size of the above fan making good the damaged comlete, connection,etc. as required.(1.43)(Make: Bajaj/Almonard) |
| 129 | S/F of Invertor board consisting of 2 nos. of 15 amp Modular plug and switch and 10 amp SP MCB complete with wiring on 8M GI box with Front cover(1.24.9 + 1.25.1+ 1.25.4 +2.6.1) |
| 130 | Provision of Armoured cable size 3 1/2 x 35sqmm (25) |
| 131 | S/F Call bell/Buzzer ISI marked suitable for DC/AC single Phase 230 volts complete as required.(1.30) |
| 132 | Supply and fixing of 45-48 Watt Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections ( Make- Crompton/Phillips/HPL/Polycab/Havells ) |
| 133 | S/F of 24W Recess Mounted Square Shape LED Luminary,Make-Havells/Crompton/Philips |
| 134 | Supply & fixing of 100 A TPN Panel board 1. 100A MCCB (Make- Legrand/Seimens/L&T/C&S/) &100A kitkat & bus bar2. 63 A four pole MCB (Legrand/Seimens/L&T/C&S)- 3nos 3. 63A DP MCB- 1 no , 63 A TPN Onload Changeover- 1 no4. Digital Volt meter & Ameter three phase 5. All accesories & Connection (Rating & Danger borad) Please Enable Macros to View BoQ information |