| 1 | Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire `'FR' ... in PVC Casing-Capping (Precision Make) on wall/ceiling.Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand(approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire FOR ECC, incl. necy. PVCclips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface) Average run 10 mtr |
| 2 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket brand(approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 3 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire brand(approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 4 | Supply and delivery of Ceilling fan 48... Sweep Crompton Greaves make |
| 5 | PHILIPS MAKE, 40WATT AS PER RATE OBTAINED FROM IRRIGATION & WATERWAYS ELEC.-MECH. SCHEDULE 2022 , GOVT. OF WEST BENGAL |
| 6 | Supply and delivery of Wall fan 16... Sweep metal blade Crompton Greaves make |
| 7 | Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire `'FR' ... in PVC Casing-Capping (Precision Make) on wall/ceiling.Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand(approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire FOR ECC, incl. necy. PVCclips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wallincl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface)Average run 1.5 mtr |
| 8 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mendinggood the damages to original finish incl. Inter connection with suitablesize of copper wire and neutral link & provision FOR earthing attachment .Legrand 2+12 way Enclosure (607712) |
| 9 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP |
| 10 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A DP |
| 11 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC |
| 12 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x126/0.4 (16 sqmm) + 1x80/0.4 (10 sqmm) as ECC |
| 13 | Fan : Supplying & Fixing MS fan clam of two piece type FOR RC ceiling as per(approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting ... (As per Drawing no. 475 of PWD Specification Book ... May 1991) |
| 14 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 10 1/3.55 2 |
| 15 | Laying on Wall / surface with Saddles / clamps.(a)Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 16 | Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below : FOR 3 core(iii)upto 10 sqmm |
| 17 | Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.2 core 10 sqmm cable |
| 18 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection Legrand FP 100 A |
| 19 | Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision FOR housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision FOR earthing attachment Legrand L&T |
| 20 | Finishing Copper Wire ends.(c)Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.6 sqmm |
| 21 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes FOR Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall FOR housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 12 Module |
| 22 | Supply & Fixing 240 V 6 A Modular type switch brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 23 | Supply & Fixing240 V 6 A Piano key type switch brand(approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required |
| 24 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket brand(approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 25 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket brand(approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 26 | Sub Total |
| 27 | GST 18% |
| 28 | CESS 1% Please Enable Macros to View BoQ information |