| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or salimar pattern roof coverings etc. complete all as specified and as directed. |
| 2 | S&F Pre painted galvalume aluminum zinc coating GI based corrugulated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and as directed. |
| 3 | S&F Pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and as directed. |
| 4 | Dismantling of wrought iron or mild steel work of any description etc. complete all as specified and as directed. |
| 5 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A) etc. complete all as specified and as directed. |
| 6 | S&F joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A) etc. complete all as specified and as directed. |
| 7 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet etc. complete all as specified and as directed. |
| 8 | S&F non asbestos fibre cement building boards of 6mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws etc. complete all as specified and as directed. |
| 9 | S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensor system (Grid) made out of GI sheet main Tee of size 23.5mmx38.50mmX0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmx19mmX0.36 mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction etc. complete all as specified and as directed by Engr-in-charge. (Make : Everest or equvalent as approved by GE) |
| 10 | Dismantling of boarding any description fixed in any position with nails/screws etc. complete all as specified and as directed. |
| 11 | S&F facia boarding of 2nd class soft wood planed one side with but joints 20mm thick and champhered one side and the boarding is matched etc. complete all as specified and as directed. |
| 12 | M&L for second class hard wood Weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed etc. complete all as specified and as directed. |
| 13 | Fixing only weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed etc. complete all as specified and as directed. |
| 14 | Dismantling of floor, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off the etc. complete all as specified and as directed. |
| 15 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar (1:6) etc. complete all as specified and as directed. |
| 16 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar (1:6) etc. complete all as specified and as directed. |
| 17 | M&L for 350x 250x 7 mm or 450X 350X 7mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick rendering in CM (1:4) finished even and rough etc. complete all as specified and as directed. |
| 18 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) etc. complete all as specified and as directed. |
| 19 | M&L for 50 mm thick cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges etc. complete all as specified and as directed. |
| 20 | M&L for PCC (1:2:4) type B2 (using 20mm graded aggregates) as in surface channels, drains including all necessary form work etc. complete all as specified and as directed. |
| 21 | Demolition of brick work or stone/boulder masonary built in cement mortar including all quions, arches, pillars etc but excluding ashler facing dressed stone work and precast concrete etc. complete all as specified and as directed. |
| 22 | M&L for old size bricks work with subclass 'B' bricks straight or curved on plan exc 6m mean radius as in CM (1:4) etc. complete all as specified and as directed. |
| 23 | M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) etc. complete all as specified and as directed. |
| 24 | Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 25 | M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces and finished the surfaces even and smooth without using extra cement etc. complete all as specified and as directed. and as directed. |
| 26 | Rendering 15mm thick in cement mortar in (1:4) on other than fair faces of brick work or concrete surfaces etc. complete all as specified and as directed. |
| 27 | Dismantling of timber fillets, rails, posts raftersn fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section etc. complete all as specified and as directed. |
| 28 | Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work) etc. complete all as specified and as directed. |
| 29 | M&L for second class soft wood wrought in scantling timber fixed etc. complete all as specified and as directed. |
| 30 | M&L for 2nd class hard wood Plain fillets of sectional area exc. 13 and not exc. 25 sqcm.square, rectangular or triangular in section, clean sawn, secured with nails or brads etc. complete all as specified and as directed. |
| 31 | Taking down chowkhats or frame n.exc 1.50 sqm each with shutter (without taking off shutters from the frame) etc. complete all as specified and as directed. |
| 32 | Taking down chowkhats or frame exc 1.50 but n.exc 4 sqm each with shutter (without taking off shutters from the frame) etc. complete all as specified and as directed. |
| 33 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue, pinned at joints etc. complete all as specified and as directed. |
| 34 | S&F 35 mm thick second class hard wood , plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers etc. complete all as specified and as directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 35 | S&F 35 mm thick second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and without sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats etc. complete all as specified and as directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 36 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc. complete all as specified and as directed. |
| 37 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; t both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etc. complete all as specified and as directed. |
| 38 | S&F steel ventilator with top hung shutter including hinges, steel peg stay etc. complete all as specified and as directed. |
| 39 | S&F galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples etc. complete all as specified and as directed. |
| 40 | S&F 4mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane etc. complete all as specified and as directed. |
| 41 | S&F 100mm size butt hinges, medium weight , cold rolled, mild steel etc. complete all as specified and as directed. |
| 42 | S&F 300mm long Aluminium alloy anodised Sliding bolt with hasp, staple(bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, etc. complete all as specified and as directed. |
| 43 | S&F 300 mm size mild steel ordinary rat rail rod pattern springs including roller and roller plate etc. complete all as specified and as directed. |
| 44 | S&F 200mm long Aluminium anodised barrel tower bolts of extruded section etc. complete all as specified and as directed. |
| 45 | S&F 150mm long Aluminium anodised tower bolts fixed with screws etc. complete all as specified and as directed. |
| 46 | S&F 150mm long Aluminium anodised handles fixed with screws etc. complete all as specified and as directed. |
| 47 | S&F mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-290, Gde E-165 etc. complete all as specified and as directed. |
| 48 | Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site etc. complete all as specified and as directed. |
| 49 | S&F 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) fixed to wall, ceiling and laid in/on floor etc. complete all as specified and as directed. |
| 50 | S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including P or S trap set in and including necessary lean cement concrete etc. complete all as specified and as directed. |
| 51 | S&F PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type etc. complete all as specified and as directed. |
| 52 | S&F in repairs vitreous china wash basin white of any pattern, flat back of size 450mmx300mm (excluding taps), waste, chain and plug including waste pipe ,suitable size of brackets and making good the damaged walls as per existing wall finish etc. complete all as specified and as directed. |
| 53 | S&F 15mm bore Fancy type CP pillar tap with capstan head, screwed down high pressure, with or with out lettered \\"Hot\\" or \\"Cold\\" with long screw shank and fly nuts, screwed for iron pipes etc. complete all as specified and as directed. |
| 54 | S&F in repairs Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinals to plugs with and including 60 mm long brass screws, pointing around urinals back in cement, fixing automatic flushing cistern with bracket, flush pipe, grating and union for discharge pipe, push tap etc. complete all as specified and as directed by Engr-in-Charge. |
| 55 | S&F in repairs Brass chromium plated shower rose with or without swivel joints 125 mm size including CP shower arm with wall flange, fixing to steel pipe or union etc. complete all as specified and as directed. |
| 56 | S&F in repairs 15mm bore fancy type CP stop valve with long shank and cup with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed etc. complete all as specified and as directed. |
| 57 | S&F in repair 15 mm bore PVC connection of 450 mm long with two brass chromium plated brass nuts and PVC washers etc. complete all as specified and as directed. |
| 58 | S&F in repairs 15 mm bore fancy type CP bib tap with crutch or butterfly handle with wall flange, screwed both ends for iron pipe or for unions and fixed etc. complete all as specified and as directed. |
| 59 | S&F in repairs 100mm dia CP Gratings etc. complete all as specified and as directed. |
| 60 | S&F in repairs fancy type CP tubular towel rail of 20mm dia, D' type OF 60cm long between flanges etc. complete all as specified and as directed. |
| 61 | S&F in repairs bevelled edge mirror of selected quality glass, of any size mounting on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers, with and including aluminium edging around of mirror etc. complete all as specified and as directed. |
| 62 | Dismantling of PVC (SWR), Cast Iron, AC, SWG soil waste and vent pipe of 75/100/110 mm bore including accessories set in cement mortar and removing rubbish from site etc. complete all as specified and as directed. |
| 63 | S&F 110mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls/trenches etc. complete all as specified and as directed. |
| 64 | S&F 75mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls etc. complete all as specified and as directed. |
| 65 | S&F 110mm bore PVC (SWR) bend any radius etc. complete all as specified and as directed. |
| 66 | S&F 75mm bore PVC (SWR) bend any radius etc. complete all as specified and as directed. |
| 67 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint of approved tint over a coat of chalk whiting priming paint etc. complete all as specified and as directed. |
| 68 | M&L for complete removal of existing treatment of wall surfaces and applying two coats of Cement Base Paint of approved tint over a coat of chalk whiting priming paint etc. complete all as specified and as directed. |
| 69 | M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper of approved tint over a coat of chalk whiting priming paint etc. complete all as specified and as directed. |
| 70 | M&L for complete removal of existing treatment of wall surfaces and applying two coats of Oil bound distemper over a coat of chalk whiting priming paint etc. complete all as specified and as directed. |
| 71 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide etc. complete all as specified and as directed. |
| 72 | M&L for preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint etc. complete all as specified and as directed. |
| 73 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer etc. complete all as specified and as directed. |
| 74 | M&L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint etc. complete all as specified and as directed. |
| 75 | Taking down unserviceable copper/aluminium point wiring of any description including all fittings and fixtures (switch , socket, switch socket combination, lamp holder, ceiling rose,light fittings and regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes etc. complete all as specified and as directed. |
| 76 | M&L for point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor with proper colour coding drawn through and including PVC Casing and Caping (medium grade) with all fittings and accessories ISI marked fixing in wall/fixed to roof,ceiling etc incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) connected to common earth dolly incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall with modular back plate and top cover for mounting switch, sockets etc including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc for one light/Bell/Exhaust fan point controlled by one, one way switch 5/6 Amps etc. complete all as specified and as directed. |
| 77 | Description all as per item No 76.00 here in before but for one 3 point 5/6 Amps switch socket outlet point controlled by one switch on the same board etc. complete all as specified and as directed. |
| 78 | Description all as per item No 76.00 here in before but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on independent boad etc. complete all as specified and as directed. |
| 79 | Description all as per item No 76.00 here in before but using 2.5 sq mm single core copper conductor cable of multistrandedFRLSH PVC insulated unsheathed 1100 volts grade for 15/16 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly etc. complete all as specified and as directed. |
| 80 | S&F Modular switch 1 way 6 A,1 module 230 Volts,50Hz, ISI marked etc. complete all as specified and as directed. |
| 81 | S&F switch 1 way 16 A,1 module 230 Volts,50Hz, ISI marked etc. complete all as specified and as directed. |
| 82 | S&F Modular Bell push 6A 1 module 230 Volts,50Hz, ISI marked all as specified and as directed. |
| 83 | S&F Bell, Ding Dong electric AC 230 Volts single pole etc. complete all as specified and as directed. |
| 84 | S&F Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked etc. complete all as specified and as directed. |
| 85 | S&F Socket, 6A/16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked etc. complete all as specified and as directed. |
| 86 | S&F ceiling rose surface bakelite 65 X 50 mm three terminal etc. complete all as specified and as directed. |
| 87 | S&F Modular angle holder insulated body with back plate for batten fitting etc. complete all as specified and as directed. |
| 88 | S&F 10W LED retro fit B-22 holder base with poly carbonate body and aluminium heat shrink Invertor lamp etc. complete all as specified and as directed by Engr-in-charge. |
| 89 | S&F LED batten surface /Roof/ wall mounted pride plus inverter battenwith Lithium Ion battery, 3 step dimming, upto 10 Hrs battery backup, charging time- 8 to 10 Hrs, 20w, 6500K V1, make Havells cat part No: LHEXASP71W020 or equivalent of philips or crompton etc. complete all as specified and as directed by Engr-in-charge. |
| 90 | S&F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 10W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) etc. complete all as specified and as directed by Engr-in-charge. |
| 91 | S&F wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base etc. complete all as specified and as directed by Engr-in-charge. Make of Havells or equivalent model of Philips/ Crompton. |
| 92 | S&F in repairs LED 2X2 PANEL of 36W 3000/6500 K Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling etc. complete all as specified and as directed. Make Havells or Equivalent of Crompton/Philips. |
| 93 | S&F LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, including lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection etc. complete all as specified and as directed. |
| 94 | S&F in repairs LED light fitting of 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size etc. complete all as specified and as directed. |
| 95 | Dismantling and taking down unserviceable main switches, DBs etc. any type / size and making good disturbed surfaces to match with the existing finishes etc. complete all as specified and as directed by Engr-in-charge. |
| 96 | S&F TPN DB with double door (IP-43), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz, concealed in wall etc. complete all as specified and as directed. |
| 97 | S&F Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, concealed in wall etc. complete all as specified and as directed. |
| 98 | S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP in the DB complete with connection testing and commissioning etc. complete all as specified and as directed. |
| 99 | S&F Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning etc. complete all as specified and as directed. |
| 100 | S&F in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 32 AMP capacity in the MCB DB complete with connection testing and commissioning etc. complete all as specified and as directed. |
| 101 | S&F Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning etc. complete all as specified and as directed. |
| 102 | M&L for sub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm PVC conduit concealed in wall/roof including taking down of old unservicible sub main wiring complete all as specified and directed.(Note Three run of 6 Sqmm including one run of 25 mm of size PVC condute shall be measured as one unit length) etc. complete all as specified and as directed. |
| 103 | S&F electric water heater storage type wall hanging mounting type with powder coated metallic body BEE 5 Star rated with diamond glass lined inner tank with maximum operating pressure of 8 bars incuding factory fitted thermostat maximum 75 Celsius with automatic thermal cutout and multifunctional saftey valve inculding suitable nuts & bolts for fixing arrangement operates on 230V ,maximum power consumtion -2kW of capacity 25 Ltrs , with all accessories and connection pipe 15mm bore 2 Nos for hot and cold water supply,geyser saftey cord with 16Amps ELCB complete including taking down old u/s Geaser & deposit to MES Store complete etc. complete all as specified and as directed. Make : Havells Cat Part No : Monza Nu GHWAMUSWH025 or equivalent Racold, Bajaj |
| 104 | Taking down exgisting unserviceable exhaust fan with any size with, blades, and louvers and keep in safe custody and deposited to Age E/M store etc. complete all as specified and as directed. |
| 105 | S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including fixing arrangement complete all as specified and directed. |
| 106 | S&F exhaust fan, PVC body AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers including fixing arrangement etc. complete all as specified and directed. |
| 107 | M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC type C-1 (1:3:6) (using 20 mm graded aggregate), and 50 mm thick pre cast RCC type B-1, (1:2:4) (using 20mm graded aggregate) for cver slabs with reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m including necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and including taking down existing old unserviceable earthing set etc. complete all as specified and as directed. |
| 108 | M&L for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade) with stranded aluminium conductor of size 10 Sqmm 4 Core, including glands, lugs, nut, bolts, washers as required at site, testing including takingdown existing cable etc. complete all as specified and as directed. |
| 109 | Excavation in trenches for foundation in soft/ loose soil n.exc. 1.5 m wide and n.exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope etc. complete all as specified and directed. |
| 110 | Returning, filling, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer etc. complete all as specified and as directed. |
| 111 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point etc. complete all as specified and as directed. |
| 112 | Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches etc. complete all as specified and as directed. |
| 113 | M&L for Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick including takingdown existing bricks etc. complete all as specified and as directed. |
| 114 | S&F 40mm dia Steel pipe of light grade pipe laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth strip including clams with bolts nuts and washers including takingdown existing pipes etc. complete all as specified and as directed. |
| 115 | S&F angles, channels or Tee sections fixed independetly interconnecting with welding work without connecting plates (cut to ordinary lengths indicated) for water tanks staging etc conforming to Fe 410-w (Gde - E- 250) Quality B & painting with two coat of black bitiminious paint over a coat of Red Oxide primer including dismanting of old unserviceable existing staging etc. complete all as specified and as directed.Make : TATA / SAIL / JINDAL |
| 116 | S&F 1000 Ltrs capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position with all fitting such as tank nipple and locking arrangement all as specified in SSR Part-I including takingdown existing tank etc. complete all as specified and as directed. |
| 117 | M&L for cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 118 | M&L for 20mm dia bore medium grade GI water tubing and connections laied in trenches, floor or fixed to wall etc. including takingdown existing pipes etc. complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately. |
| 119 | M&L for 40mm dia bore medium grade GI water tubing and connections laied in trenches, floor or fixed to wall etc. including takingdown existing pipes etc. complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately. |
| 120 | S&F in replacement of 20mm gun metal globe valve with iron wheel screwed both end fixed for iron pipe etc. complete all as specified and as directed. Make : Zoloto or ISI marked. |
| 121 | M&L for cutting of existing steel tubing for alterations or additions (each cut measured) and inserting new Tee, bend, elbow etc for 25 to 40 mm dia GI pipe etc. complete all as specified and as directed by Engr-in-Charge, Please Enable Macros to View BoQ information |
| 122 | M&L for cutting of existing steel tubing for alterations or additions (each cut measured) and inserting new Tee, bend, elbow etc for 25 to 40 mm dia GI pipe etc. complete all as specified and as directed by Engr-in-Charge, Please Enable Macros to View BoQ information |