| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above GL) all as specified and directed. |
| 2 | M&L for 75mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in plinth protection finishing surface even and fair all as specified and directed. |
| 3 | M&L Forming Contraction (Dummy) joints 75 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade 'A' in plinth protection |
| 4 | Demolition of cement concrete (un-reinforced) of any description as in sunken slabs, existing roof treatment any type complete all as specified and directed |
| 5 | M & L for rendering 10mm thick in cement mortar (1:3) on fair faces of brick work and finishing the surface even and smooth with WPC without using extra cement as in sunken floor and wall complete all as specified and as directed. |
| 6 | Supply only integral water proofing compound |
| 7 | S&F 40mm bore HDPE pipe as in spout pipes in sunken floors complete all as specified and directed. |
| 8 | M & L for applying two coats of water proofing coating by using super latex manufactured by pidilite industries limited (or equivalent product manufactured by Sika/fosroc/choksey chemical), water and cement ratio 1:4:7 or the ratio as instructed by manufacturer on sunken floor and wall complete all as specified and as directed. |
| 9 | M&L PCC 1:5:10 lean concrete type D2 40mm graded aggregate as in filling of sunken floors. |
| 10 | M & L for PCC 1:2:4 type B1 using 20mm graded aggregate 40mm thick as in sub base to receive floor finishes complete all as specified and directed. |
| 11 | Dismantling roof treatment of any description including cement mortar bedding(But not backing)cleaning the surface by blowing,washing and rubbish off the premises complete all as directed. |
| 12 | M&L App based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforment with polyster non woven fabric (wt reinforcement not less than 150 gms/sqm) laid on primed surfaced application complete all as apecified and directed (Primer should be measured and paid as per Item above). |
| 13 | M&L for 10 mm thick rendering on fair faces of brick works / Concrete surfaces finished even and smooth without using extra cement in cement mortar 1: 3complete all as specified and as directed |
| 14 | M&L for priming evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sq.m including cleaning the surface. |
| 15 | M&L applaying two coat of Aluminium paint over APP Membrane complete all as apecified and directed. |
| 16 | Cutting out cracks to V section in existing roofs or terracing ,cleaning out ,wetting, grouting with cement and sand slurry 1:3 |
| 17 | M&L for 25mm thick PCC type B0 (1:2:4) using 12.5 mm graded crushed aggregate in padding concrete and the like all as specified and directed. |
| 18 | Taking down cement plaster on brick work or stone wall etc including racking out joints, hacking for key, scrubbing down with water etc all as specified and directed. |
| 19 | M & L for two layer (15 mm thick ) Rendering of top layer 5 mm thick with WPC over a 10 mm thick base layer rendering in CM 1:4 on concrete masonary or surfaces other than fair face of brick work finished fair and even without using extra cement.Note WPC shall be measured and paid separetely in supply only item. |
| 20 | M & L for rendering 10 mm thick in cement mortar 1:6 on brick or concrete surfaces finished even and smooth without using extra cement all as specified and as directed. |
| 21 | M& L for rendering 10 mm thick cement plaster in CM 1:3 on fair faces of brick work on concrete surfaces on ceiling including finished even and smooth all as specified and directed. |
| 22 | M & L for preperation of newly plastered surfaces of walls and applying two coats of oil bound distemper on wall surfaces over a coat of alkali resistant primer ocomplete all as specified and directed. |
| 23 | M&L for preperation of new plastered wall surface of any description and applayng two coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 24 | Preparation of ceiling surfaces and applying two coats of white wash on surface of on ceiling /soffits of slabs, chajjas all as specified and as directed. |
| 25 | M & L for complete removal of existing treatment and applying two or more coats of 100% premium acrylic emulsion paint (200 micron ) having VOC less thean 50 gm / litre and UV resistance as per IS- 15489-2004, Alkali & Anti- fungal resitance, dirt resistance exterior paint of required shade (Company Depot Tinned) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over wall surfaces over a coat of Anti fungal primer complete all as specified and as directed. |
| 26 | M & L for complete removal of existing treatment of internal walls and applying two or more coats of 100% premium Anti Fungal emulsion paint ( 200 micron )having VOC less thean 50 gm / litre and UV resistance as per IS- 15489-2004, Alkali & Anti- fungal resitance, dirt resistance exterior paint of required shade (Company Depot Tinned) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over wall surfaces over a coat of Anti fungal primer complete all as specified and as directed. |
| 27 | M&L for applying two coats of smart care crack seal with open and widen the cracks in a 'V' shaped groove and provide a strong base for adhesive ofcrack seal to the surface wire brush and clean the area throughly with water to free it from dust and loose particles any algal /fungal growth must be cleaned using bio - wash such as leaching powder complete all as specified and directed. |
| 28 | M& L for applying two coats of Damp proof ( Acrylic water proof) of fiber reinforced elastomeric liquid on filling of crack seal applied portion on both sides of cracks each side 75mm wides complete all as specified and directed. |
| 29 | M&L for applying two coats of Damp proof ( Acrylic water proof) of fiber reinforced elastomeric liquid including filling of crack seal on walls complete all as specified and directed. |
| 30 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles in all as specified |
| 31 | M & L for Providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) in PCC 1:3:6 type C1 using 20mmgarded aggregate and setting in mortar 1:4 complete, in walls complete all as specified and directed. |
| 32 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for |
| 33 | Use and waste of form work to sides and soffits of shelves, cooking platforms etc rough finished surfaces |
| 34 | M & L for RCC 1:2:4 type B1 using 20mm graded aggregate as in shelves, kitchen platforms etc all as specified and directed |
| 35 | M & L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed |
| 36 | M & L for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed |
| 37 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons incl granite slab in kitchen platform Laid, bedded and pointed in any mortar etc all as specified and as directed. |
| 38 | M & L for 18 to 20 mm thickk 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado or cooking platform etc laid over cement screed bed 15 mm thick in CM 1 : 4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 39 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 40 | Dismantling of floor hearth or wall tiling, terrazo tiles of anmy thickness including cement mortar bedding (but not backing) removing tiles and rubbish off the premises. |
| 41 | M&L Glazed Ceramic Coloured Tiles, 450x300/300x600x7mm thick in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:4 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed. |
| 42 | M & L for 25mm thick cement concrete type B-0, 1:2:4 (12.50 mm grade aggregate) as in levelling course in flooring finished even and fair under floor finishes. |
| 43 | M&L for vetrified ceramic tiles 10mm thick full body (light shade ) (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. |
| 44 | M & L for non skid joint free coloured ceramic tiles 7 to 8 mm thick (Square/Rectngler) area exceeding 0.11 sqm and but n exceeding 0.18 sqm , in floor etc . set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including cement screed or bedding layer of cement mortar 15 mm thick in 1:4 complete all as specified and as directed. |
| 45 | M & L for non skid joint free coloured ceramic tiles 7 to 8 mm thick (Square/Rectngler) area exceeding 0.11 sqm and but n exceeding 0.18 sqm , in dado/Skirting etc . set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including cement screed or bedding layer of cement mortar 10 mm thick in 1:4 complete all as specified and as directe. |
| 46 | M & L for non skid joint free coloured ceramic tiles 7 to 8 mm thick of size 300mmX300mm in floor set and jointed in cement clurry and pointed with coloured cement to match with coloured tiles over and including cement screed or bedding layer of cement mortar 15 mm thick in 1:4 complete all as specified and as directe. |
| 47 | M&L for 100 mm thick cement concrete Type B-2, 1:2:4 (using 20mm graded stone aggregate), as in floors, etc, and finished the cement concrete surfaces even and smooth with out using extra cement, complete all as specified and as directed. |
| 48 | Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge |
| 49 | Material and labour for suspended false ceiling using anodized aluminum snap grid frame work. Including Hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete. Exposed metal frame ceiling with 8mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid as per manufacturer instruction all a specified and directed by Enginner in Charge. |
| 50 | Taking down chowkat with shutter without taking out shutter from the frame exc 1.5 and n.exc 4 Sqm each |
| 51 | Taking down chowkat with shutter without taking out shutter from the frame n.exc 1.5 Sqm. |
| 52 | Taking down shutters of any description n exc 1 sq. m each. |
| 53 | Taking down Shutters of description exc 1sq.m and n exc 2 sq. m each complete all as specified and as directed. |
| 54 | S&F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. |
| 55 | S&F 35 mm thick second class hardwood glazed and skeleton shutters divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers and prepared to receive glass, gauze, etc., edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauze, etc.complete all as specified and as directed. |
| 56 | S & F 35. mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides as per manufactures instructions complete all as specified and as directed. |
| 57 | S & F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed. |
| 58 | S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed. |
| 59 | S&F 150 mm size Aluminium handles, Extruded aluminium alloy handles, abricated type, anodised complete all as specified and as directed. |
| 60 | S&F 300 mm long Aluminium sliding door bolt, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed. |
| 61 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ®Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 62 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: including stainless steel butt hinges and necessary S Sscrews) |
| 63 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frame work, stone, concrete or brick surrounds, glazed with putty or fixed with beadings. |
| 64 | S&F 3.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5 sq mtr in each pane complete all as specified and as directed. |
| 65 | S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples all as specified and as directed |
| 66 | S&F in repairs Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples all as specified and as directed |
| 67 | S&F in repair harrison rails mild steel CP of 20mm external dia and 1.60 mm thick for curtain rod including brackets complete all as directed. |
| 68 | Dismantling plain or corrugated steel sheeting any guage thickness from Hangar Doors complete all as specified and as directed |
| 69 | S&F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 70 | S&F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Eaves boards, ridge fixed with self tapping screws as specified |
| 71 | Supply and Fixing Stainless steel Kitchen Cup/Saucer/Kitche utensils holder basket, corrosion resistance, seamless glossy finish, Nickel chrome palted using 5 mm dia wire/SS perforated sheet assembled and fabricated as reqd size and finish complete all as specified and as directed |
| 72 | Supply and Fixing for Telescopic drawer channel of Stainless steel zinc finish (silver colour) of weight capacity minimum 35 kgs including necessary fixing arrangements hinges and SS screws all as specified and as directed. |
| 73 | Supply and Fixing soild handle of Stainless steel chromium plated of 200 mm “D” shape including necessary fixing arrangements hinges and screws complete all as specified and as directed. |
| 74 | Supply and Fixing ball catches with 8 mm dia steel ball and brass body and striking plate including letting in and necessary fixing arrangements hinges and SS screws complete all as specified and as directed. |
| 75 | Supply and Fixing 25mm thick machine pressed veneered decorative plywood grade I (with BWR resin) with decorative face veneers on one side and other side balancing with white lamination assembled as in drawers/cupboards/modular kitchen moulded/sliding provision on channel as required including necessary fixing arrangements all as directed. |
| 76 | S&F aluminium powder coated three track sliding window with two shutters of 5mm thick tinted glass of modigaurd and one shutter of stainless steel wire mesh including good quality of bearing handle, locks, PVC rubber lining including frame work etc complete all as specified. :-Three track bottom – 20957, Three track top/vertical – 20958, Handle – 20606,Interlocking – 20605, Top and bottom – 20604. |
| 77 | M&L for aluminium powder coated louvered ventilator with provision of exhaust fan using ‘Jindal” aluminium section including glass and stainless steel wire mesh including frame work etc complete all as specified and directed by Engineer-in-Charge. |
| 78 | Dismantling of structural steel work |
| 79 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming Fe 410 -W (Gde- E- 250) quality- Fe A |
| 80 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 81 | S & F Rolled Mild Steel roof trusses(framed),trussed ,purlins ,rails and fastenings etc.,confirming to Fe 410 - S including distance pieces, cleats, etc., complete. |
| 82 | Dismantling wooden boarding, any description, fixed in any position with screws complete all as specified and directed . |
| 83 | M/L for 18mm thick plywood BWR grade type BB fixed with fevicol and nails for working table / storage almirah to the size and pattern as shown in Drg and as directed by Engr-in-charge. |
| 84 | -Ditto- as above but 12mm thick. |
| 85 | -Ditto- as above but 6mm thick. |
| 86 | S&F in repair 18/19 mm pre- laminated particles board exterior Gde, pre-laminated one side with decorative choice lamination & other side balancing white laminateion fixed with screws to timber frame work. (for Kitchen cabinets/cupboards / shelves and similar works) |
| 87 | M/L for 2nd class H.W. plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in 2nd class H.W. sectional area n. exc. 6 Sqcm. |
| 88 | M/L for 2nd class H.W. plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in 2nd class H.W. sectional area exc. 6 Sqcm and not. exc 13 Sq cm. |
| 89 | S/F butt hinges 75mm extruded brass with MS hinges pin, bright polished and fixed type D-11 |
| 90 | S/F brass cup board lock 75mm size 4 level with duplicate keys |
| 91 | S/F brass handles extruded fabricated type 100mm size. |
| 92 | S &F in repair 300mm MS ordinary rat tail rod pattern spring including roller and roller plate complete in repairs |
| 93 | M&L for preparation of new surface of wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of pink primer. |
| 94 | S&F in repair Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring Overall length of cover plate 150mm. |
| 95 | M&L for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 96 | Demolition and breaking up drain pipes (Salt glazed ware /PVC/ AC or Reinforced concrete) set in cement mortar |
| 97 | S&F 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors |
| 98 | -do- as above but 110mm dia |
| 99 | M&L for PVC (SWR) bends of any radius with oval and access door of 75mm dia |
| 100 | -do- as above but 110mm dia |
| 101 | M&L PVC (SWR) branch piece single (single ‘Y’) equal or unequal with oval access door suitable for 75mm bore pipe with access door |
| 102 | M&Lfor PVC (SWR) vent cowl of 110mm dia |
| 103 | S&F in repair PVC (SWR) Nahani trap with grating of diameter of outlet 75mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4). |
| 104 | S & F Grating doom 100mm dia of Stainless steel with holes/without holes for waste pipes all as specified and directed. |
| 105 | S&F PVC Waste pipe as in WHB/sink Size 32mm dia and 750mm long all as speciifed and directed |
| 106 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 15mm dia |
| 107 | Supply and laying and concealed for 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc) on walls/ceiling or laying in floors complete all as specified and directed |
| 108 | M&L for cutting chases, pinning in making good to face for concealed water tubing in stone concrete blocks or slab walls all as specified and directed. |
| 109 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 20mm dia |
| 110 | M&L for GI tubing 20mm dia medium grade with all fittings & fixtures complete laid in trenches fixed in repairs |
| 111 | Fixing only 20mm dia tubes, any grade, to walls and ceilings or laying in floors |
| 112 | S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm in repairs. |
| 113 | S&F vitreous chinaware EWC including connection to drain or outgoing pipe and to PVC flushing pipe, antisyphonage pipe, PVC low level flushing cistern 10 ltr capacity with brackets of approval Make and all necessary fittings etc complete all as directed and specified incl PVC seat cover fixed in repair |
| 114 | S&F in repair vitreous china, squatting pan of 'Orissa' pattern, long pan, size 580 mm x 440 mm, white, with 'P' of 'S' Trap, front or back inlet and foot rests any pattern, including concrete bedding and PVC low level flushing cistern 10 Ltr capacity including 32mm PVC flush pipe, all internal fitting, inlet, outlet pipe connections etc. complete all as specified and as directed. |
| 115 | S & F in repair 10 Ltr PVC low level flushing system plastic valve with inlet ball valve float including brackets , flush pipes to pedestal pan , including all joints fixied in repair all as specified and directed. |
| 116 | S&F in repair vitreous china wash hand basin, white, 550 mm x 400 mm flat back, including providing CI brackets, CP Pillar Tap, PVC waste pipe 32mm dia, chromium plated, brass, waste coupling, 32 mm dia all as specified and as directed. |
| 117 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified . |
| 118 | S&F in repair for 15 mm dia CP pillar tap CP fancy type cast copper alloy complete all as specified and directed |
| 119 | S&F in repair 15 mm dia CP brass PVC connection 45 cm long including check nuts etc complete all as specified and directed |
| 120 | M&L in repair for 15 mm bore bib cock straight line model chromium plated cast copper alloy with wall flange complete all as specified and directed. (Model No FLR-5047N of jaquar or Equivalent) |
| 121 | S & F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers ® all as specified and directed. |
| 122 | S & F wall mixter 3-in-1 system with provision for both hand shower and over head shower complete with 115mm long bend pipe connecting legs and wall flange (with hand and over head shower) all as specified and directed. |
| 123 | Dismantling of PVC water tanks of 500 ltr capacity and removing to store and all as specified and directed by Engr-in-Charge. |
| 124 | Dismantling of PVC water tanks of 1000 ltr capacity removing to store and all as specified and directed by Engr-in-Charge. |
| 125 | S&F rotational moulded polyethylene water storage tank 500 Litres capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 20 mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge. |
| 126 | S&F rotational moulded polyethylene water storage tank of 1000 ltr capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 25 mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge. |
| 127 | S & F in repair 15mm bore Angular stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (min weight 90 gms) with flange all as specified and directed. |
| 128 | S & F in repair brass Chromium plated shower roses 125mm size with or without swivel joints any size including fixing to steel pipe or union all as specified and directed. |
| 129 | S &F sink cock with regular swinging spout (wall mounted model) with wall flange all as specified and directed. |
| 130 | S &F Two way bib cock with wall flange 15mm dia all as specified and directed. |
| 131 | S & F Corner glass shelf with brackets all as specified and directed. |
| 132 | M & L for RCC 1:2:4 type B1 using 20mm graded aggregate as in Chajjas, shelves, Roof slabs etc all as specified and directed |
| 133 | M& for form work to bottom, sides and soffits of Chajjas, roof slabs etc rough finished surfaces all as specified and directed. |
| 134 | Supply only integral liquid water proofing compound . |
| 135 | M&L for preperation old treated plastered surface of walls Stone, RCC roof of any description and applayng one coat of weather proof exterior emulsion paint all as specified and as directed. |
| 136 | M & L preparing of old decorated surfaces of walls and applying one coat of distemper oil-emulsion complete as specified and directed. |
| 137 | M & L preparation of old painted wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 138 | M & L preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint all as specified and directed. |
| 139 | M&L for precast solid cement concrete block masonry exc 10cm in width built with solid blocks Grade C1 (1:3:6 mix) 20mm graded aggregate and set in CM (1:6) all as specified and directed. |
| 140 | S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 500 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I |
| 141 | S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 1000 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I |
| 142 | S & F in repairs 20 mm Brass valves ,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed |
| 143 | S & F in repair Vitreous China wash basin, white, flat back, size 550 x 450mm including brackets all as specified and directed. |
| 144 | S&F in repairs Vitreous China bowl Urinal, flat back, size of 465x355x265mm white with grating and union for discharge pipe and PTMT waste coupling with waste pipe (excluding flushing cistern, flush pipe and waste pipe) |
| 145 | S&F in repairs PVC syphon with rod, flushing wiser, for low level flushing cistern incl PVC handle with adjustable lever (flushing cistern kit )complete all as specified |
| 146 | S&F in repairs Stainless steel Kitchen Sink coupling 100/125mm dia all as specified and directed |
| 147 | Disconnecting existing exc 250 Ltr and incl 500 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc removing scale and dirt from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position including (a) Removal of algae/dust/mud,foreign material from tank(sides and bottom) with wire brushes & washing with bleeching powder and water (b) Collecting all above sludge on cane bucket and throwing it not less than 50mtr beyond the area where directed by Engineer-in-Charge (c)Cleaning of complete tank (internally) with fresh water and draining again.complete all as directed by Engineer-in-Charge. complete all as specified and directed. |
| 148 | Disconnecting existing exc 500 Ltr and upto 1000 Ltr capacity tank , setting aside (or lowering if required) for repairs, cleaning, etc removing scale and dirt from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position including (a) Removal of algae/dust/mud,foreign material from tank(sides and bottom) with wire brushes & washing with bleeching powder and water (b) Collecting all above sludge on cane bucket and throwing it not less than 50mtr beyond the area where directed by Engineer-in-Charge (c)Cleaning of complete tank (internally) with fresh water and draining again.complete all as directed by Engineer-in-Charge. complete all as specified and directed. |
| 149 | Supply and Fixing 500/1000 ltrs tank covers (lid) all as specified and directed. |
| 150 | M&L for GI tubing 15mm dia medium grade with all fittings & fixed complete to walls & ceiling or laid in floors in repairs |
| 151 | S &F in repairs Bathroom Cabinet Mirror (450x600mm) size PTMT all as specified and directed. Please Enable Macros to View BoQ information |