| 1 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 2 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 3 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 4 | Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 6 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 9 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 13 | Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 14 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 15 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 16 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 17 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 18 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with ironbrackets 40x3mm size, bolts, nuts and washers etc., including making necessary connectionswith rain water pipes complete.0.63 mm thick with zinc coating not less than 275 gm/m² |
| 19 | Cement upto 8 KM |
| 20 | Sand upto 35 KM |
| 21 | Stone Chips upto 8 KM |
| 22 | Bricks |
| 23 | Supply of 300 sq.mm 3.5 core PVC/XLPE insulated PVC seathed heavy duty, armoured electrical cable with Aluminium conductor for working voltage up to and including 1100 volts. (Conforms to IS:1554, part-1) |
| 24 | 240sq.mm. aluminium lugs |
| 25 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of size exceeding 185 sq mm but not exceeding 400 sq mm direct in ground including excavation & refilling the trench etc as required, but excluding sand cushioning & protective covering |
| 26 | Laying & fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on wall surface as required. Above 185 sq.mm to 400 sq.mm (clamped with 20mmX3mm GI Tape) |
| 27 | Providing & fixing 630 amps, 35kA, adjustable thermal setting & breaking capacity MCCB with thermomagnetic release & terminal spreaders in existing cubicle panel board including drilling holes in cubical panel, making connections, etc. as required. |
| 28 | Supply of 35 sq.mm 3.5 core PVC/XLPE insulated PVC seathed heavy duty, armoured electrical cable with Aluminium conductor for working voltage up to and including 1100 volts. (Conforms to IS:1554, part-1) |
| 29 | 35 sq.mm. aluminium lugs |
| 30 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of size not exceeding 35 sq mm direct in ground including excavation & refilling the trench etc as required, but excluding sand cushioning & protective covering |
| 31 | Laying & fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on wall surface as required. Upto 35 sq.mm (clamped with 1mm thick saddle) |
| 32 | Providing & fixing 100 amps capacity busbar chamber with 4 strips of length 300mm made of copper suitable for 100 amps capacity complete with all accessories including connections, earthing the body etc. as required |
| 33 | Providing & fixing 100 amps, TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewirable type fuses, including drilling holes in metal board, making connections, etc. as required. |
| 34 | Supplying & fixing of 32 amps, SPN rating, 240 volts, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing & commissioning etc. as required |
| 35 | Providing & fixing 32 amps, TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewirable type fuses, including drilling holes in metal board, making connections, etc. as required. |
| 36 | Supply of 10 sq.mm, 4 core PVC/XLPE insulated PVC seathed heavy duty, armoured electrical cable with Aluminium conductor for working voltage up to and including 1100 volts. (Conforms to IS:1554, part-1) |
| 37 | 10 sq.mm. aluminium lugs |
| 38 | Lightning finial, 25 mm dia X 300 mm long, copper |
| 39 | Fixing of lighting conductor finial (single prong) with base plate including holes etc. complete as required. |
| 40 | Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories & providing massonary enclosure with cover plate having locking arrangement & watering pipe etc. (with charcoal or coke & salt) as required |
| 41 | providing & fixing 25 mm X 5mm GI strip on surface or in recess for connection as required |
| 42 | S.I.T.C of 90/100W LED street lighting luminarie with pressuire die cast housing & toughened glass cover(IP 66 protection) in existing pole for supply voltage 100-270V AC, 50Hz. Luminarie shall be conform to IS:10322 part-5/section-3 & shall be complete with all necessary accessories as required. |
| 43 | S.I.T.C of 90/100W LED Flood lighting luminarie with pressuire die cast housing & toughened glass cover(IP 66 protection) in existing pole for supply voltage 100-270V AC, 50Hz. Luminarie shall be conform to IS:10322 part-5/section-5 & shall be complete with all necessary accessories as required. |
| 44 | Supplying & fixing of 75mm X 75mm X 50mm deep/(\\"4\\"X4\\") size of PVC box on surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required |
| 45 | Add GST @ 18% |
| 46 | Add Labour Cess @1% Please Enable Macros to View BoQ information |