| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 3 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 4 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 6 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 7 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I. |
| 9 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level.1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level.1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size) |
| 11 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level.1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 12 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level.1:4:8 (1 Cement : 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size) |
| 13 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 14 | Making plith protection 50mm thick of cement concrete 1:3:6 (1 Cement : 3 coase sand ( zone-III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 15 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to Plinth Level-1:1.5:3 (1 cement ; 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 16 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reionforcement :(1:1.5:3 (1 cement : 1.5 : coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size). |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, fotting, bases of columns, etc. for mass concrete |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended Floors, roofs, landings, balconies and access platform |
| 20 | Shelves (Cast in situ) |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, Plinth beams, girders, bressumers and cantilevers |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form forColumn, Pillars, Piers, Abutments, Posts and struts |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form forStairs, (Excluding landings) except spiral-staircases |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form forWeather shade, Chajjas, corbels etc. including edges |
| 25 | Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 26 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 27 | Providing Toe steel reinforcement of 8mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) |
| 28 | Providing Toe steel reinforcement of 10mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) |
| 29 | Providing Toe steel reinforcement of 12mm to 25 mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) |
| 30 | supplying, fitting and fixing 250X20X6mm L-type M.S clamp properly fishtailed, including maiking holes and setting as same in 250X125X75mm. Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I. |
| 31 | S/F M.S. grill made of 20 x 6mm M.S. flat / Square bar as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.) |
| 32 | Providing and fixing fan hooks of 16mm dia M.S. bar & 1 meter long, bent torequired size and shape, placed in position and fixed in the R.C.C.slab/beam at the time ofcasting all complete as per building specification and direction of E/I. |
| 33 | Supplying, fitting and fixing 20mm dia M.S. Bar 1 meter long holding down bolt with nuts washers 100 X100 X6mm plate fitted and fixed with cement concrete (1:24) as per approved design all complete as per building specification and direction of E/I. |
| 34 | Labour for fabricating, erecting, hoistion and fixing in position structrral steel work in R.S. Joist, channel, Angle, Tee, flat, plate, latice member, built up compound section in column, girder, stair case, or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding ( machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/I. |
| 35 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 36 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 37 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 38 | Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 39 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 40 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 41 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 42 | Making 6X6mm grooves in plaster surface over walls truely horizontal or vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curring with all leads and lift of water all complete as per building specification and direction of E/I. |
| 43 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 44 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I. |
| 45 | Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales, smokes, grease and sand preparing, including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 46 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio). |
| 47 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 48 | Providing 250mm wide brick drain in cement mortar (1:6) with as. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 49 | Water proofing for old and New Roof Slab : - Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:- |
| 50 | Surface preparation :- Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/fosroc or equivalent. Proiding and reparing of all corners and joints such as those between the parapet wall and the roof slab etc. shall be chamfered with 150mm x 150mm fillet of mortar (Cement sna - 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr. Fixit or equivalent. |
| 51 | Before chamfering surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 52 | 1st coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green, 1st coat should be applied @ 1.50 kg/sqm/coat. For the purpose of measurement the entire treated surface will be measured. |
| 53 | 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured. After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be doen as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing coating to be protected from damage before screed over it. Water proofing Brand-Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fixit Pidifin 2K/MYK Auafin TG, Product Performance - chemical |
| 54 | Base part A : Acrylic copolymer, Part B : Specially graded cementtitious powder - Density 1.6 kg/l (mixed density) at +270C Tensile strength ~ 2N/mm2 after 28 days (with Fibre cloth) (according to ASTM D 2370) Pullout Bond Strength ~ 2 N/mm2 (concrete failure) (According to ISO 4624) Slant-shear bond strength~4 N/mm2 (According to FIP 5.15) Elongation at Break ~ 35% without Fibre Cloth and 20% with fibre cloth (According to ASTM D 2370) |
| 55 | Protection of treatedsurface with PCC : - The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 Mt x 2mt keeping 6mm gap between the panel joint intergal water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the acreed concrete (paid separately for this items) all corners shall be chamfered with 150mm x 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between PVC pipe outlet and concerte surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insentive epoxy putty of Sika India pvt Ltd/MYK Schomberg/Dr. Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\" |
| 56 | Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately) Brand - Sika India Pvt. Ltd./MYK Schomberg/Dr. Fixit/Fosroc. Warantly for five years. |
| 57 | Covering of treated surface with PCC : Providing 50 mm thick cement concrete M-20 (1:1.5:3) maintaining slope in alternate 2mt x 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with admixture of integral water proffing and placing in position, skirting curing, taxes and royalty all complete as per building specification and direction of E/I. Panels that has been left should be casted next day. there should be 6mm gap between Panels Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X421 ic Dr. Fixit Pidiproof LW+ |
| 58 | Providing and filling of 6mm thick Groove between 50mm PCC Panels with 6mm thick 25mm deep termocol strip and filling the rest 25mm with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of E/I. (with 18% GST) Brand - Sika-Polysulphide, Fosroc-Thioflex 600 Dr. Fixit Pidi Seal PS (42P), MYK Seal PS or Equivalent. |
| 59 | Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 mabove ground level and removal of rubbish up to a distance of 50 moutside the periphery of the area cleared. |
| 60 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 61 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. barsat every third course of half brick masonry. |
| 62 | 'Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble - Area of slab upto 0.50 sqm |
| 63 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 64 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:.3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 65 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 66 | Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 67 | 300x10 mm |
| 68 | 150x10 mm |
| 69 | Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 125 mm |
| 70 | Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 71 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 72 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1 .25 mm M.S. laths with 1.25 mm thick top cover |
| 73 | Providing and fixing ball bearing for rolling shutters. |
| 74 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1 :3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 75 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 76 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 77 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 78 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade using ordinary cement |
| 79 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 80 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado andpillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment tomatch the shade of the slabs, including rubbing and polishing complete. |
| 81 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 : 4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size- Size of Tile 600 x 600 mm |
| 82 | Providing and fixing on wall face unplasticied Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion (i) Single socketed pipes. |
| 83 | 75 mm |
| 84 | 110 mm |
| 85 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 86 | Couplar - 110mm |
| 87 | Single tee with door - 75x75x75 mm |
| 88 | Single tee with door - 110x110x110 mm |
| 89 | Single tee without door - 75x75x75 mm |
| 90 | Single tee without door - 110x110x110 mm |
| 91 | Bend 87.5° - 75mm |
| 92 | Bend 87.5° - 110mm |
| 93 | Shoe 110mm |
| 94 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 95 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 96 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 97 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : : |
| 98 | Ridges plain (500 - 600mm) |
| 99 | Gutter (600 mm over all girth) |
| 100 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 101 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 102 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 103 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer- in-Charge.60mm thick cement concrete paver block of M-35 gradewith approved colour, design & pattern. |
| 104 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : - For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) - Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 105 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides |
| 106 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 107 | With float glass panes of 4.0 mm thickness |
| 108 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 109 | on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness |
| 110 | Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 111 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 112 | Supplying and Fixing Gusset Plate |
| 113 | Carriage of matarials |
| 114 | Bricks - 8km (1k + 7p) |
| 115 | Sand - 10km |
| 116 | Chips -22km |
| 117 | Metal - 22km |
| 118 | Fly Ash Brick - 15km |
| 119 | Paver Block - 15km |
| 120 | Disposal of Earth-5 km |
| 121 | Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. Group C |
| 122 | Twin control point wiring in PVC conduit, with modular type switch - Wiring for twin control light point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size G.I. box etc. as required. |
| 123 | Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 124 | Power plug wiring in PVC conduit (4 x 4 sq.mm.) - Wiring for light/power with 4 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 125 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 126 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire (For 5/6A Plug Points) |
| 127 | 2x2.5 Sqmm + 1x2.5 sq mm earth wire |
| 128 | 4x6 Sqmm + 2x6 sqmm earth wire (For essential TPN DB) |
| 129 | 4x10 Sqmm + 2x6 sqmm earth wire (For Normal TPN DB) |
| 130 | Telephone wiring in existing conduit - Supplying and drawing following pair, 0.5 sq.mm FR PVC copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required. 3 Pair |
| 131 | S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. |
| 132 | S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 75mm x 75mm x 50mm deep/(4\\" x 4\\") |
| 133 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 134 | 5/6 amps, one way switch |
| 135 | 15/16 amps, one way switch |
| 136 | 5/6 amps, 3 pin socket outlet |
| 137 | Telephone socket with shutter outlet |
| 138 | TV antenna socket outlet |
| 139 | S/F Modular type electronic fan regulator -Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 140 | S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required |
| 141 | S/F power plug point with Modular type accessories - Supplying and fixing suitable size G.I. box with modular plate cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required. |
| 142 | S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required. |
| 143 | S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required. |
| 144 | S/F Call bell buzzer - Supplying and fixing call bell/buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. |
| 145 | ITC exhaust fan upto 450mm sweeo - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required. |
| 146 | S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 147 | 4 way (4 + 12), Double door, Horizontal type |
| 148 | 6 way (4 + 18), Double door, Horizontal type |
| 149 | S/F vertical type T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet, MCB distribution board, 415 volts, on surface/recess, complete, sheet, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 + 12), Double door, Vertical type |
| 150 | S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required. |
| 151 | 6/32 amps, Single Pole |
| 152 | 40 amps, TPN |
| 153 | S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required.80/100 amps |
| 154 | Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required |
| 155 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 156 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required. |
| 157 | P/F G.I. lightning condutor finial :-Providing and fixing of lighting conductor finial , made of 25mm dia 300mm long , G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required. |
| 158 | Reverting, sweating and soldering lightning conductor tape :-Reverting , sweating and soldering of copper / G.I. tape (with another copper / G.I. tape , base of the finial or any other metallic object ) as required. |
| 159 | P/F G.I. lightning conductor tape in horizontal run :-Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required.( for Horizontal run ). |
| 160 | P/F G.I. lightning conductor tape in vertical run :-Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required.( for Vertical run ). |
| 161 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm. but not exceeding 95 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 162 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required - 75/80W LED Flood light |
| 163 | S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722 with all neccssary accessories as required 12 W LED Round Down light |
| 164 | Supply, Installation, testing and commissioning of following, size ceiling fan 3 Blades confirming to IS : 374 : 2019 including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. 1200mm (48\\") BLDC 5star rating 32W Ceiling Fan |
| 165 | S.I.T.C. of following rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required.20/22W LED Tube Light |
| 166 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 167 | Providing and fixing of XLPE, Aluminium Armoured PVC Cable confirming to IS IS7908 (Part-1) 1988 0f grade 1.1KV. Make:- Havells / Finolex / Polycab 50 Sq.mm, 3.5 core |
| 168 | Providing ,Laying & drawing of XLPE insulated PVC sheathed 3.5 core, 95 sq mm Aluminium conductor , Armoured electrical cable for working voltage upto 1100 volts |
| 169 | Providing ,Laying & drawing of XLPE insulated PVC sheathed 4.0 core, 16 sq mm Aluminium conductor , Armoured electrical cable for working voltage upto 1100 volts |
| 170 | 9/10Watt LED Bulb |
| 171 | Supplying of 9'' (230 mm) metal sweep A.C. Exaust fan / freashair fan of Model Ventil Air DS Havels make equivalent approved make. |
| 172 | 12\\" (300mm) metal exhaust fan |
| 173 | Supplying of 15'' (380 mm) metal sweep 1400 RPM heavy duty A.C. Exaust fan Havels make equivalent approved make. |
| 174 | 80/90W su-pended type industrial COB LED highbay light with aluminum die cast heat sink |
| 175 | Circular shape LED decorative corrosin resistant dia cast aluminum housing surface/suspended LED luminaries 30 to 40 Watt |
| 176 | MAIN LT PANEL:- Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG sheet steel, totally enclosed IP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than MS 40 X 40 X 5 mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switchgears. |
| 177 | 4 pole MCCB 250 A,35 KA with fixed thermal magnetic setting. |
| 178 | 4 pole MCCB 40 A,10 KA with fixed thermal magnetic setting. |
| 179 | 4 pole MCCB 63 A,16 KA with fixed thermal magnetic setting. |
| 180 | 6/32 A,DP |
| 181 | 50/63 amps, DP |
| 182 | 300 amp 415 V heavy duty three phase with neutral bus bar chamber. |
| 183 | 100 amps, 4 pole Changeover |
| 184 | Pilot lamp for indicator |
| 185 | 3 way 4 pole selector switch |
| 186 | DIGITAL VOLT METER 500V(3phase class 0.5) |
| 187 | DIGITAL A METER 500V(3phase class 0.5) |
| 188 | C.T. Coil |
| 189 | Panel Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG sheet steel, totally enclosed IP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 40mmx40mmx5mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switchgears. |
| 190 | Panel Commissioning / Testing Charges 15% |
| 191 | Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all complere as per specification and direction of E/I. |
| 192 | Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. - 15mm |
| 193 | Providing and fixing Gun metal full way valve of approved quality all complete as per specification and direction of E/I. |
| 194 | 25mm dia and weight not less than 500 gms |
| 195 | 32mm dia and weight not less than 700 gms |
| 196 | Making holes in walls for laying G.I. pipes and restoring the same after pipe laying as per specification and direction of E/I. |
| 197 | 125mm thick wall |
| 198 | 250mm thick wall |
| 199 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. |
| 200 | Glass shelf with C.P. brass rail - 450mm x 125mm |
| 201 | Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror - 600mm x 450mm |
| 202 | C.P. brass towel rail 20mm x 600mm with bracket container |
| 203 | C.P. brass soap dish container medium quality with screw and hinges etc. |
| 204 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I.580mm long - With 10 liter low level PVC cistern |
| 205 | Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I.With 'P' trap - 12.5 lit low level PVC Cistern |
| 206 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.Flat back or standard corner (600mm x 350mm) |
| 207 | Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindl stop cock approved quality of weight not less than 30 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 208 | Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.For classification of soil item - A |
| 209 | Lbour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L. |
| 210 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 211 | Supplying and fixing NP2 Hume pipe etc. (150mm dia) |
| 212 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board - 610x460 mm bowl depth 200 mm |
| 213 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 214 | 25 mm nominal outer dia Pipes |
| 215 | 32 mm nominal outer dia Pipes |
| 216 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. |
| 217 | 15 mm nominal outer dia Pipes |
| 218 | 20 mm nominal outer dia Pipes |
| 219 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 220 | Providing and fixing PTMT grating of approved quality and colour. C.P. Gratings |
| 221 | Circular type - 100mm dia |
| 222 | Circular type - 125 mm dia |
| 223 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 224 | Special type C.P. Bath room Fitting for V.I.P.Buildings(JAL, Jaquar, Mark or Equivalent) |
| 225 | Bib cock (2 Way) |
| 226 | Pressure Adjustable Shower with revolving joint (Health Façade) |
| 227 | Towel Ring |
| 228 | DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates)Drilling upto 30 mtr. Depth below G.L. in Rural Area |
| 229 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressure and equipmentsas well as fule, lubricants and cost of transportation of rig machine and other vehical up to Site. |
| 230 | (a) From 0.00 M to 50.00 M below G.L. |
| 231 | (b) From 51.0 M to125.00 M |
| 232 | (c) From126.0 M to150.00 M |
| 233 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 234 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge100 mm nominal size dia |
| 235 | Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge |
| 236 | Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge |
| 237 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge |
| 238 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 239 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 240 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 241 | Supplying Submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible Pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 2 HP |
| 242 | Supplying Fully automatic star delta starter to operate induction motor working on 415V, 3 phase, 50 hz with no volt coil, Over load element, ON-OFF push buttons, with necessary materials and connected to supply, etc. complete starter with original sheet steel encloser as per IS : 3914 |
| 243 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 244 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work - 50 mm nominal dia Pipes |
| 245 | Add 18 % GST |
| 246 | Add 1% Labour Cess Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail