| 1 | Providing and replacing damaged/old U-PVC pipes (working pressure 6 kg / cm²) Single socketed pipe of approved make and suitable size, including cutting, removal of existing pipe, jointing, fixing and testing complete as required at site as per direction of Engineer-in-Charge |
| 2 | 110 mm diameter pipes |
| 3 | 75 mm diameter pipes |
| 4 | Providing and replacing damaged/old uPVC coupler of approved make and suitable size, including removal of existing coupler, jointing, fixing and testing complete as required at site as per direction of Engineer-in-Charge. |
| 5 | 110 mm diameter pipes |
| 6 | 75 mm diameter pipes |
| 7 | Providing and replacing damaged/old uPVC Y junction of approved make and suitable size, including removal of existing Y junction, jointing, fixing and testing complete as required at site as per direction of Engineer-in-Charge. |
| 8 | 110 mm diameter pipes |
| 9 | 75 mm diameter pipes |
| 10 | Providing and replacing damaged/old uPVC plain bend of approved make and suitable size, including removal of existing bend, jointing, fixing and testing complete as required at site as per direction of Engineer-in-Charge. |
| 11 | 110 mm diameter pipes |
| 12 | 75 mm diameter pipes |
| 13 | Providing and replacing damaged/old uPVC pipe clip of approved make and suitable size, including removal of existing clip, fixing complete as required at site as per direction of Engineer-in-Charge. |
| 14 | 110 mm diameter pipes |
| 15 | 75 mm diameter pipes |
| 16 | Providing and replacing damaged/old uPVC door bend with new one of approved make and suitable size, including removal of existing bend, fixing, jointing and testing complete as required at site as per direction of Engineer-in-Charge. |
| 17 | 110 mm diameter pipes |
| 18 | 75 mm diameter pipes |
| 19 | Providing and supplying M.S. wire nails of approved quality and material complete as per direction of Engineer-in-charge. |
| 20 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.External work |
| 21 | PN - 10 Pipe, 50 mm OD (SDR-11) |
| 22 | PN - 10 Pipe, 63 mm OD (SDR-11) |
| 23 | PN - 10 Pipe, 75 mm OD (SDR-11) |
| 24 | PN - 10 Pipe, 90 mm OD (SDR-11) |
| 25 | PN - 16 Pipe, 25 mm OD (SDR-7.4) |
| 26 | PN - 16 Pipe, 32 mm OD (SDR-7.4) |
| 27 | PN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 28 | Providing and replacing damaged PPR reducing TEE with new one of approved make and suitable size, including cutting, removing the damaged tee, refixing, jointing, testing and making good the connections complete as required at site as per direction of Engineer-in-Charge. |
| 29 | 32mm*20mm |
| 30 | 25mm*20mm |
| 31 | Providing and replacing damaged PPR reducing socket with new one of approved make and suitable size, including cutting and removing the damaged fitting, heat fusion jointing, testing and making good the connection complete as required at site as per direction of Engineer-in-Charge. |
| 32 | 40mm*32mm |
| 33 | 32mm*25mm |
| 34 | 25mm*20mm |
| 35 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. |
| 36 | 75 mm diameter pipes |
| 37 | 110 mm diameter pipes |
| 38 | Providing and replacing old/damaged/stolen PPR gate valve of approved make and suitable size, including cutting and jointing the pipe, fixing the new valve, testing and making good the connections complete as required at site as per direction of Engineer-in-Charge. |
| 39 | 20 mm dia |
| 40 | 25 mm dia |
| 41 | 32 mm dia |
| 42 | Providing and fixing ball valve (PPR) of approved quality, High or low pressure, with plastic floats complete : |
| 43 | 40 mm dia |
| 44 | 50 mm dia |
| 45 | 63 mm dia |
| 46 | 90 mm dia |
| 47 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. |
| 48 | Providing and replacing damaged/old Upvc double Y Junction with new one of approved make and suitable size, including removal of existing bend, fixing, jointing and testing complete as required at site as per direction of Engineer-in-Charge. |
| 49 | 110 mm diameter pipes |
| 50 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 300 mm. |
| 51 | Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc. as perdirection of Engineer-in-Charge. |
| 52 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge. A) Nominal concrete 1:3:6 or richer mix (including equivalentdesign mix) |
| 53 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. a) Cement concrete prepared with batch mixing machine |
| 54 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugallycast (spun) iron pipes of diameter : |
| 55 | Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. |
| 56 | 50 mm dia nominal bore |
| 57 | 65 mm dia nominal bore |
| 58 | 80 mm dia nominal bore |
| 59 | Providing flanged joints to double flanged C.I./ D.I. pipes and specials,including testing of joints : |
| 60 | 80 mm diameter pipe |
| 61 | 100 mm diameter pipe |
| 62 | 150 mm diameter pipe |
| 63 | 200 mm diameter pipe |
| 64 | Providing and fixing PPR MTA (brass insert) of approved make and size, including jointing with PPR pipe by heat fusion, complete in all respects as directed by Engineer-in-charge. |
| 65 | 25mm dia |
| 66 | 32mm dia |
| 67 | Providing and fixing PVC double socket connector of approved make, including jointing with PPR pipes by heat fusion welding, complete in all respects as directed by Engineer-in-charge. |
| 68 | 75mm × 900mm |
| 69 | 110mm × 900mm |
| 70 | Providing and applying PVC solvent cement of approved make for jointing of PVC pipes and fittings, complete in all respects, as per direction of Engineer-in-Charge. |
| 71 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 72 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineerin-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 73 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 74 | Hiring and operating of Wire suspended platform i.e. Cradle including erection charges, shifting from one building to other building (vehicle to be self arranged by agency), shifting from same building on top to top & cost of operator completeand its deployment as per direction of Engineer-in-charge for maintenance work of water supply lines & waste water pipe lines. |
| 75 | Carrying out repair and maintenance of sanitary fittings and fixtures in common areas, including rectification of minor defects; repair and maintenance of water supply lines including fixing/replacement of PPR unions (20 mm, 32 mm, 50 mm, 63 mm, 75 mm), gate valves (40 mm, 50 mm, 65 mm, 75 mm), ball valves (40 mm, 50 mm, 65 mm, 75 mm) and CI lead joints; rectification of leakages in terraces and shafts; tightening of pipe joints; attending minor plumbing works such as leak repairs, replacement of washers, fixing of taps, and ensuring proper water flow; fixing of PPR pipes (40 mm, 50 mm, 65 mm, 75 mm), uPVC rainwater pipes (75 mm, 110 mm) and pipe clips; maintenance of drainage system including removal of blockages in soil and waste pipes. Further, after handing over of flats, any complaints such as leakage in water supply, non-availability of water supply, drainage issues, etc., shall be recorded in the complaint register, intimated to the concerned Junior Engineer, and got rectified promptly, complete as per the directions of the Engineer-in-Charge. |
| 76 | Total Rs=. 71,18,844.00 |
| 77 | Multiplying factor (0.973 expect on item no. 7, 29 & 30)= Rs. 63,13,751.00 |
| 78 | Cost index Rs. 2,08,309.00 |
| 79 | Special Condition:-1. Setup of Maintenance Office – The office shall be equipped with furniture, computers, registers, stationery, a printer, and all necessary T&P (tools and plants). 2. Deployment of Staff – Adequate staff shall be deployed, including DEO, mates, plumbers, carpenters, etc., for attending complaints in the maintenance office. 3. Complaint Redressal – Any complaint regarding leakage of pipes or similar plumbing work shall be attended to within same day. In case of delay, valid reasons shall be submitted. If reasons found unjustified penality will imposed Rs.5000/ per complaint per day. 4. Uniform and ID Cards – All deployed staff shall wear proper complete uniforms and carry valid ID cards issued by EE/DDA. If non comply, penality will imposed Rs.1000/ per person. 5. Misconduct of Staff – If any staff member is found engaged in private work or any complaint is received against them, the contractor shall be liable for a penalty of Rs.5000/- per complaint.6. Monthly Feedback – A feedback form duly signed by residents/RWA, with more than 75% positive feedback, shall be submitted by the agency every month. It shall cover all aspects such as cleaning, civil maintenance, plumbing, etc. The format of the feedback form shall be provided by EE/DDA. 7. Access to Flats – If access inside a flat is required for maintenance purposes, prior permission shall be obtained from the RWA/allottee. 8. Scope of Work – All allied works required for carrying out maintenance shall be the responsibility of the agency. Any extra item beyond the scope shall be paid as per contract provisions. 8. Record Maintenance – The agency shall maintain proper records of all complaints and their disposal, along with photographic evidence before and after completion of the work. 9. 10.Penalty for Unsatisfactory Work – A penalty of Rs. 1,000 shall be imposed for each instance of unsatisfactory work executed at site. 10. Recovery of 1% Electrical/water charges- will be made from bill. 11. Daily swept garbage, rubbish etc. shall be collected at the designated collection point .12. The work will be terminated without any notice if the services will be handed over to RWA or any other civic Body. Nothing extra will be paid in this regard.13. A sum of Rs. 1000/- per day as token penalty will be imposed in case of specified area not swept/cleaned satisfactorily.14. A penalty of Rs. 2500/- per person/per day shall imposed if any of the Environment Assistant found absent and the work is got done by the department on his behalf.15. Any challan from MCD/NGT or any other department on account of not cleaning the complete area satisfactory will be borne by the agency.16. Contractor has to set up a complaint centre which consist 1 Data Entry Operator & 2 no. of Supervisor for which nothing shall be paid extra.17. Complaints related to leakages in water supply line (riser, downtakeetc) shall be attended immediately within 4 hour, penalty of Rs.5000 per complaint shall be levied, if resolution is not done within mentioned time limit, it will be done at risk and cost of contractor. 18. If resolution of complaint (other than from S.No.1) is not done within 3 days of filing of the complaint, penalty of Rs.1000 per day per complaint shall be levied.19. Payment to the contractor shall be made as per register for relevant items. Format of register is as under:- Please Enable Macros to View BoQ information |