| 1 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet, complete all as specified and as directed. |
| 2 | Dismantling of timber fillets, rails, posts raftersn fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified and as directed. |
| 3 | Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work), complete all as specified and as directed. |
| 4 | M&L for second class hard wood Weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed, complete all as specified and as directed. |
| 5 | All as per Item no 4 above herein before specified but fixing only, complete all as specified and as directed. |
| 6 | M&L for 2nd class hard wood Plain fillets of sectional area exc. 13 and not exc. 25 sqcm.square, rectangular or triangular in section, clean sawn, secured with nails or brads, complete all as specified and as directed. |
| 7 | S&F in repairs for Non asbestos fibre cement building boards of 6mm thick fixed or laid/ inserted totimber/GI/Aluminium framework with screws, complete all as specified and as directed. |
| 8 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue, pinned at joints, complete all as specified and as directed. |
| 9 | S&F 30mm thick glazed for windows, ventilators etc,and skeleton shutters, open rebated and prepared to receive glasss, gauze etc (with sash bars) edges of framiing plain chafered or rounded. Fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR part I section 8, clause 8.24 (a) supplied and fitted to chowkhats, complete all as specified and as directed. |
| 10 | S&F 30mm thick glazed for windows, ventilators etc,and skeleton shutters, open rebated and prepared to receive glasss, gauze etc (without sash bars) edges of framiing plain chafered or rounded. Fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR part I section 8, clause 8.24 (a) supplied and fitted to chowkhats, complete all as specified and as directed. |
| 11 | S&F 35 mm thick second class hard wood , plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers, complete all as specified and as directed.(Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 12 | M&L for 2nd class hard wood for Glazed and skeleton shutters of 25mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and as directed. |
| 13 | Providing & fixing with fully perforated 12mm thick micro tgular edged or 10 mm thick square edged GRG false ceiling tiles false ceiling at all heights with GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595x595 mm of approved texture, desing and patterns having moisture content less than 2%,humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)- 1970 and light reflectance of 85% (minimum) to be laid in ture horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @120 grams per sqm including both sides) comprising of main -T runners of size 15x32 mm of length 3000mm, cross T of size 15x32 mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel items ( galvanizing @ 80 grams per sqm) i.e 50 mm long, 8mm outer diametre M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. the work shll be carried out as per specifications, drawing and as per directions of the Engineer in charge, complete all as specified and as directed. |
| 14 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off, complete all as specified and as directed. |
| 15 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 16 | M&L for coloured Non skid ceramic tiles 7 to 8mm thick (square/rectangular) are of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer for laying floor finishes in CM (1:6) etc, complete all as specified and as directed. |
| 17 | S&F glazed ceramic coloured tiles 7 to 8mm thk 450x350 size in vertical surface set and jointed in neat cement slurry and pointed in whiete cement paste pigmented to the shade over and including 10mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:4) etc, complete all as specified and as directed. |
| 18 | Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed. |
| 19 | Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed. |
| 20 | S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed. |
| 21 | S&F steel window or ventilator fixed type with glazing bar complete, complete all as specified and as directed. |
| 22 | S&F galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and as directed. |
| 23 | S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane, complete all as specified and as directed. |
| 24 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition, complete all as specified and as directed. |
| 25 | Use & Waste of formwork to sides and soffits of shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and as directed. |
| 26 | M&L for reinforced cement concrete (1:2:4) type B1 (using 20 mm crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 27 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 28 | M&L for 50 mm thick cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges, complete all as specified and as directed. |
| 29 | S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed. |
| 30 | S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 31 | Demolition of brick work or stone/boulder masonary buit in cement mortar including all quions ,arches ,pillars etc but excluding ashler facing dressed stone work and precast concrete, complete all as specified and as directed. |
| 32 | M&L for brick work with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4), complete all as specified and as directed. |
| 33 | M&L for brick work with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4), complete all as specified and as directed. |
| 34 | Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 35 | M&L 15 mm thick rendering ( in two coats 10mm+5mm) on fair faces of brick work or concrete surface in CM (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated, complete all as specified and as directed.Note:-WPC will be measured and paid separately as supply only. |
| 36 | Supply only integral water proofing compond, complete all as specified and as directed. |
| 37 | M&L for 10 mm thick rendering in CM (1:6) on Brick/stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and fair (without using extra cement), complete all as specified and as directed. |
| 38 | M&L for preparation of newly plastered surfaces and applying three coat of cement base paint, complete all as specified and as directed. |
| 39 | M&L preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over 3mm thick wall care putty (Birla white or equivalent), complete all as specified and as directed. |
| 40 | M&L complete removal of existing treatment and applying two coats of oil bound distemper using mechnical spray gun/hand rollars over a coat of interior wall primer with and including 2mm thick wall care putty in two coats (Birla white or equivalent), complete all as specified and as directed. |
| 41 | M&L preparation existing treatment on walls and applying two coats of cement base paint, complete all as specified and as directed. |
| 42 | Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and as directed. |
| 43 | S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. |
| 44 | S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. |
| 45 | S&F of 110 mm bore PVC (SWR) bend any radius with access door, complete all as specified and as directed. |
| 46 | S&F of 75 mm bore PVC (SWR) bend any radius with access door, complete all as specified and as directed. |
| 47 | S&F of 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, complete all as specified and as directed. |
| 48 | S&F of 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, complete all as specified and as directed. |
| 49 | S&F of 110 X 75 mm bore PVC (SWR) reducer including jointing with solvent cement, complete all as specified and as directed. |
| 50 | Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, complete all as specified and as directed. |
| 51 | S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and as directed. |
| 52 | Taking up or down 20 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, complete all as specified and as directed. |
| 53 | S&F of 20 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and as directed. |
| 54 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 55 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as directed. |
| 56 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar, complete all as specified and as directed. |
| 57 | M & L Granite (of any type) work 20MM thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 20mm thick CM (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed. |
| 58 | S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete, complete all as specified and as directed. |
| 59 | S&F Vitrous china wash down water closet pan pedestal pattern white, exlcuding fixing bolts, flushing cistem & Flush pipe including PVC Seat Cover white recess bottom type mild steel chromium plated or aluminium hanging device complete all as specified and directed including dismantling existing EWC, complete all as specified and as directed.Make Hindware, Jaquar or equivalent |
| 60 | S&F in repairs brass chromium plated tubular towel rail of 20mm dia D' type 60cm long between flanges, complete all as specified and as directed. |
| 61 | S&F in repairs 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement, complete all as specified and as directed. |
| 62 | S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed. |
| 63 | S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws, complete all as specified and as directed. |
| 64 | S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and as directed. |
| 65 | Cutting chases, pinning in, making good to facings where required and pointing in CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and as directed. |
| 66 | S&F in repairs angle , stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed. |
| 67 | S&F 100 mm size butt hinges, medium weight , cold rolled, mild steel, complete all as specified and as directed. |
| 68 | S&F of 100 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, complete all as specified and as directed. |
| 69 | S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple(bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed, complete all as specified and as directed. |
| 70 | S&F 125 mm size Aluminium handles, cast type, anodised and fixed, complete all as specified and as directed. |
| 71 | S&F mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-410-0 or Fe 310-0, complete all as specified and as directed. |
| 72 | S&F in 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 73 | S&F in repairs Brass chromium plated shower rose with or without swivel joints 125 mm size including fixing to steel pipe or union, complete all as specified and as directed. |
| 74 | S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, complete all as specified and as directed. |
| 75 | S&F 25mm Dia curtain rod (curtain rails) aluminum alloy powder coated with and including decorative knobs etc, complete all as specified and as directed. |
| 76 | S&F Vitreous China wash basin, flat back, size 450x300 mm white, excluding taps, waste, chain and plug and rcelain stopper but including brackets, complete all as specified and as directed. |
| 77 | Taking down unserviceable copper/aluminium point wiring of any description including all fittings and fixtures (switch , socket, switch socket combination, lamp holder, ceiling rose,light fittings and regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes, complete all as specified and as directed. |
| 78 | Dismantling and taking down unserviceable main switches, DBs etc. any type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed. |
| 79 | M & L for point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor with proper colour coding drawn through and including PVC Casing and Caping (medium grade) with all fittings and accessories ISI marked fixing in wall/fixed to roof,ceiling etc incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) connected to common earth dolly incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall with modular back plate and top cover for mounting switch, sockets etc including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc for one light/Bell/Exhaust fan point controlled by one, one way switch 5/6 Amps, complete all as specified and as directed. |
| 80 | Description all as per item No 79.00 here in before but for one 3 point 5/6 Amps switch socket outlet point controlled by one switch on the same board. |
| 81 | Description all as per item No 79.00 here in before but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on independent board. |
| 82 | Description all as per item No 79.00 here in before but using 2.5 sq mm single core copper conductor cable of multistrandedFRLSH PVC insulated unsheathed 1100 volts grade for 15/16 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 83 | Supply and fix Modular switch 1 way 6 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 84 | Supply and fix Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 85 | Supply and fix Socket, 6A/16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 86 | Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal, complete all as specified and as directed. |
| 87 | Supply and fixing Modular angle holder insulated body with back plate for batten fitting, complete all as specified and as directed. |
| 88 | Supply and fixing 10W LED retro fit B-22 holder base with poly carbonate body and aluminium heat shrink Invertor lamp, complete all as specified and as directed. |
| 89 | Supply and fixing LED batten surface /Roof/ wall mounted pride plus inverter battenwith Lithium Ion battery, 3 step dimming, upto 10 Hrs battery backup, charging time- 8 to 10 Hrs, 20w, 6500K V1, complete all as specified and as directed.Make Havells cat part No: LHEXASP71W020 or equivalent of philips or crompton |
| 90 | Supply and fixing LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 10W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min), complete all as specified and as directed. |
| 91 | Supply and fixing wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base complete all as specified and directed, complete all as specified and as directed |
| 92 | Supply and fixing in repairs LED 2X2 PANEL 36 W 3000/6500 K Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, complete all as specified and as directed. |
| 93 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, including lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed. |
| 94 | S & F LED light fitting 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting, complete all as specified and as directed. |
| 95 | Supply and fixing in repairs LED bed side lamp 3W LED Black 3000K, complete all as specified and as directed. Cat Part No 48042 of Philips or equivalent in Havells/Crompton. |
| 96 | S&F TPN DB with double door (IP-43), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz, concealed in wall, complete all as specified and as directed. |
| 97 | Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, complete all as specified and as directed. |
| 98 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP in the DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 99 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 100 | Supply and fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 32 AMP capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 101 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 102 | M&L for in repairs forsub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLSH including drawing into 25 mm PVC conduit concealed in wall/roof, complete all as specified and as directed.(Note Three run of 6 Sqmm including one run of 25 mm of size PVC condute shall be measured as one unit length). |
| 103 | Supply and fixing electric water heater storage type wall hanging mounting type with powder coated metallic body BEE 5 Star rated with diamond glass lined inner tank with maximum operating pressure of 8 bars incuding factory fitted thermostat maximum 75 Celsius with automatic thermal cutout and multifunctional saftey valve inculding suitable nuts & bolts for fixing arrangement operates on 230V ,maximum power consumtion -2kW of capacity 25 Ltrs , with all accessories and connection pipe 15mm bore 2 Nos for hot and cold water supply,geyser saftey cord with 16Amps ELCB complete including taking down old u/s Geaser & deposit to MES Store, complete all as specified and as directed.Make : Havells Cat Part No : Monza Nu GHWAMUSWH025 or equivalent Racold, Bajaj |
| 104 | Supply and Fixing exhaust fan, PVC body AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers including fixing arrangement complete all as specified and directed. Incl taking down old unserviceable exhaust fan and deposit to MES Store, complete all as specified and as directed. |
| 105 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1:3:6) type C-1 , 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I, complete all as specified and as directed. |
| 106 | Material and labour in repairs for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 10Sqmm 4 Core, including glands, lugs, nut, bolts, washers as required at site, testing, complete all as specified and as directed. |
| 107 | Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and as directed. |
| 108 | Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer, complete all as specified and as directed. |
| 109 | Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed. |
| 110 | Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, complete all as specified and as directed. |
| 111 | M&L in repairs Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick, complete all as specified and as directed. |
| 112 | S & F in repairs Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers, complete all as specified and as directed. |
| 113 | S & F in replacement of angles, channels or Tee sections fixed independetly interconnecting with welding work without connecting plates (cut to ordinary lengths indicated) for water tanks staging etc conforming to Fe 410-w (Gde - E- 250) Quality B & painting with two coat of black bitiminious paint over a coat of Red Oxide primer including dismanting of old unserviceable existing staging, complete all as specified and as directed. |
| 114 | Supply and fixing and replacement of Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position with all fitting such as tank nipple and locking arrangement all as specified in SSR Part-I of capacity 2000 ltr, complete all as specified and as directed. |
| 115 | M&L for cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and as directed. |
| 116 | M & L for taking up or down existing 20 mm dia bore water tubing and connections and cleaning & re-fixing with and including new ISI marked pipe fittings, in new or old position in trenches, floor etc or fixed to wall, complete all as specified and as directed.Note : Excavation and earth work shall be measured and paid separately. |
| 117 | M & L for taking up or down existing 40 mm dia bore water tubing and connections and cleaning & re-fixing with and including new ISI marked pipe fittings, in new or old position in trenches, floor etc or fixed to wall, complete all as specified and as directed.Note : Excavation and earth work shall be measured and paid separately. |
| 118 | Supply and fixing in replacement of gun metal globe valve iron wheel screwed both end for iron pipe fixed all directed of size 20 mm, complete all as specified and as directed.Make : Zoloto or ISI marked. |
| 119 | M& L for cutting of existing steel tubing for alterations or additions (each cut measured) and inserting new Tee, bend, elbow etc 25 to 40 mm dia GI pipe, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 120 | M& L for cutting of existing steel tubing for alterations or additions (each cut measured) and inserting new Tee, bend, elbow etc 25 to 40 mm dia GI pipe, complete all as specified and as directed. Please Enable Macros to View BoQ information |