| 1 | Construction of Processing Shed for Cleaning, Grading,Dalmil and Flour Mil Unit |
| 2 | A - SECTION : CIVIL WORK COSTExcavation for foundation inearth, soil of all types,sand, gravel and soft murum, includingremovingthe excavatedmaterial up to a distance of 50m.beyond thebuildingareaandstackingand spreadingas directed, dewatering, preparing thebedfor thefoundation and necessary back filling, ramming,wateringincludingshoringandstruttingetc.complete.(Lift upto1.5m.) |
| 3 | Providing solingusing 80 mmsize trap metal in15 cm. layer including fillingvoids withCrushedsand/grit, ramming,wateringetc.complete. |
| 4 | Filling in plinth and floors with approvedexcavated material in 15cm. to 20cm. Layersincludingwateringandcompactingetc.complete. |
| 5 | Providing and laying Cast in situ/Ready Mixcement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation andbedding including bailing out water, Steelcentering, formwork, laying/pumping, compacting,roughening them if special finishis tobeprovided,finishing if requiredand curing complete, with fullyautomatic micro processor basedPLCwithSCADAenabled reversible DrumTypemixer/concreteBatchmix plant (Pan mixer) etc. complete. With fineaggregate(CrushedsandVSIGrade). |
| 6 | Providing and laying in situ /ReadyMix cementconcrete M-20 of trap / granite/quartzite/gneissmetal for R.C.C.work in foundations like raft, stripfoundations,grillage andfootings of R.C.C. columnsand steel stanchions etc. including bailing outwater, Steel centering formwork, laying/pumpingcover blocks, compaction andcuringrougheningthesurface if special finish is tobeprovided (Excludingreinforcementandstructuralsteel)etc.complete,withfullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concreteBatchmix plant (Pan mixer) etc. complete. With fineaggregate(CrushedsandVSIGrade). |
| 7 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap / granite/quartzite/ gneissmetal for R.C.C. columns as perdetaileddesignsanddrawingoras directed includingsteel centering, formwork, cover blocks,laying/pumping, compaction finishing the formedsurfaceswithcementmortar1:3ofsufficientminimumthickness togivea smoothandeven surface orroughening if special finish is tobe providedand curing etc. complete.(Excluding reinforcementand structural steel).with fully automatic microprocessor basedPLCwith SCADAenabled reversibleDrumTypemixer/ concrete Batchmix plant (Panmixer) etc. complete. With fineaggregate(Crushedsand VSI Grade). |
| 8 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap /granite/quartzite/ gneissmetalfor R.C.C. beams andlintels as per detailed designs anddrawingsorasdirected including steel centering, formwork,cover blocks, laying/pumping, compactionandroughening the surface if special finish is to beprovided and curing etc. complete. (Excludingreinforcement and structural steel).with fullyautomatic microprocessor basedPLCwithSCADAenabled reversible Drum Type mixer/ concreteBatchmix plant (Panmixer) etc. complete. Withfine aggregate (Crushed sand VSI Grade). |
| 9 | Providingand fixing inpositionTMT-FE-500barreinforcementof variousdiameters for R.C.C. pilecaps, footings, foundations, slabs, beamscolumns, canopies, staircase, newels, chajjas,lintels pardis, copings, fins, arches etc. as perdetaileddesigns, drawings andschedules. includingcutting,bending,hookingthebars,bindingwithwiresortackweldingandsupportingasrequiredcomplete. |
| 10 | Providing second class Burnt Brick masonry withconventional/ I.S. typebricks incementmortar1:6inplinth as backing in compositemasonry includingbailingoutwatermanually, striking joints, rakingoutjointsandwateringetcComplete. |
| 11 | Providing second class Burnt Brick masonry with conventional/ I.S. typebricks incementmortar 1:6 in superstructure including striking joints, raking out joints,watering andscaffoldingetc. Complete. |
| 12 | Providing internal cement plaster 12mmthick insingle coat in cement mortar 1:4without neerufinish toconcreteor brick surfaces, inall positionsincluding scaffolding and curing etc. complete. |
| 13 | Providing internal cement plaster 20mm thick inSingle coats in cementmortar 1:4without neerufinish, to concrete, brick surface, in allpositions including scaffolding and curingetc.complete. |
| 14 | Providingandapplyingwashableoil-bounddistemperof approved colour and shade toold and newsurfaces in two coats including scaffolding,preparing the surfaces. (excluding theprimer coat.)etc. complete. |
| 15 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. SSRI.NO. 35.13 @ 79.00 Per Sqm |
| 16 | Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. SSR I.NO. 33.30 @ 796.0 Per Sqm |
| 17 | Providingstructuralsteelworkintrusses,othersimilartrussedpurlinsandmemberswithallbracing, gussetplates etc. as per detaileddesigns anddrawings oras directed including cutting, fabricating, hoisting,erecting fixing in position,Making riveted/bolted/welded connection and one coat of anticorrosivepaint and over it 2 coats of oil painting approvedqualityandshadeetc. complete. |
| 18 | Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). SSR I.NO. 38.04 @ 870.00 Per Sqm |
| 19 | Providing and fixing rolling shutter fabricated fromsteel lathsofminimumthickness0.9mmwith lockplateof3.15mmthicknessreinforcedwith35x35x5mmanglesectionfittedwithslidingboltsandhandlesforbothsides,deepM.S.channelsectionofdepthandthickness not less than 65 mm and 3.15 mmrespectively with hold fast arrangements,M.S. Bracket plate300x300x3.15mmminimumsize and shapewith square bar,suspensionshaftofminimum32mmdiameter,hoodcoverofM.S. sheetnot lessthan0.9mmthickness and of any size attop and safety devices including mechanical gearoperation arrangement consisting of worm gearwheelsandwormsof highgradecast ironor mildsteel and one coat of red lead primer etc.complete. (I.S. 62481979) (Withoutmechanicalgear). |
| 20 | Providing andfixing50mmx50mmMildSteelsquarepipe framedsteelwindowsof various sizes as perdetailswithwelded squarebars 12mmat 10 cmcenter tocenterwithouthotdipzinc coatingwithout/with ventilator including fabrication, glazingwithplain / obscuredglasspanes5mmthick ofapprovedtype and quality, all fixtures and fastenings andfinishingwithonecoatofprimercomplete. |
| 21 | Providingandfixingboarddisplayinginformation,suchas 'Nameofwork, Tendercost,NameofContractor,Work completion and liability period etc', havingrectangularshapeof1.20mx0.90msizemadeout18gauge (1.25mm) thickmildsteel sheet paintedwithone coat of Zinc chromate stovingprimer and twocoatsof enamel paint on front sideandgrey stoveenamelonbacksideandborder/messages/symbolsetc.withapprovedcolourshade paint complete,onM.S.angle of size 35 x 35 x 3 mmframe withproperly cross braced M.S. angles of size35mmx35mmx3mmdulypaintedincluding TwoM.S.angleironpostsofsize65mmx65mmx6mm,3.65mlongpaintedwithalternateblackandwhite bandsof 25 cmwidth including all fixtures etc.and fixingtheboards in1:4:8concreteblockof size60 cmx60 cm x 75 cm including, excavation, refilling,transportation,andlabouretccomplete.Spec.No.Asdirected by Engineer in Charge. |
| 22 | TurboVentilator 24\\": Providingwindoperated tuboventilatorsystemofvarioussizesovertheexistingroofinclusingcuttingCGIsheets,properfixinginpositiontotrue line and level with all fixtures and fasteningsincudingetc. complete. |
| 23 | B - SECTION : ELECTRICAL WORK COSTSupplying and erectingmainswith 3 x 2.5 sq.mmFRLSHcopper PVC insulatedwire laid in providedconduit/trunking/insidepole/Busbarsoranyotherplacesasperspecification |
| 24 | Supplying and erecting LEDPanel Light (600mmX600mm)Max.30havingCRCApowdercoatedhousing,polystyrenediffuserhavingsystemlumensoutputofMin. 3600 Lumens,min. efficacy of 120 lumen/W,CRI>80,CCTupto6500K,BeamAngleof120deg.,max.rippleof5%,THD<10%,p.f.>0.95,operatingrangeof120-270V, surgeprotectionof 2.5 kV, Life class of50,000 Hrs. at L70B50 including driver, havingmountingarrangementwithboardforsurfacetypeorspring loadedmountingclips completewith3yearswarranty. |
| 25 | Point wiring in for light/fan/bell in 20mmmetalconduitwith1.5 sq.mm(2+1E) FRLSHgradecopperwire, flush type switch, earthing and requiredaccessoriesasperspecificationNo |
| 26 | Supplying and erecting steel tubular swaged pole139.7x114.3x88.9mmdiawith4.5x3.65x3.25mmthickness(4.5+1.75+1.75m) lengthrespectivelyandtotal8.0mlongwithpolecap,baseplateinprovidedfoundation.(weight101kg)asperspecification |
| 27 | Providngearthingwithgalvanizedironearthplatesize60x60x0.6cmcompletewithallmaterials,testing&recording the results asper specification |
| 28 | Providingpipetypeearthingwith40mm.dia.G.I.pipeor 20mmdia. G.I. Rodcompletewithallmaterialstestingandrecordingtheresultsasper specification |
| 29 | Supplying, erecting&markingDP-MCB6Ato32A, Cserieswithratedshort-circuitbreakingcapacity(Icn)10kAinprovideddistributionboardasperspecification |
| 30 | Supplying,erecting&markingDP-MCB6Ato32A,Bserieswithratedshort-circuitbreakingcapacity(Icn)10kAinprovideddistributionboardasperspecification |
| 31 | SupplyinganderectingGI sheet 1.6mm(16SWG)havingzinccoatingof350micronswithgalvanizationprocess compliance to IS2629:1985 tobeused forfabricationofboxespanelboardsetc.includingcutting,bending, drilling, welding, riveting etc. andpaintingwithonecoatofredleadpaintand2coatsofenamelpaint. |
| 32 | Supplyinganderectingmarine(Waterproof)plywood18/19mmthick fixed towall or onprovidedpanelboardwithnecessarymaterials suchas screws,wallfasteners, supports, nut bolts etc. complete withcompliancetoIS720:2010. |
| 33 | Wiring for plug on board with Switch socket surface/concealed type, copper wiringandearthingandwithmodularaccessoriesasperspecification |
| 34 | Supplyinganderectingregular/standardmodelceilingfanof600mm.Sweepcompleteerectedinpositionasper specification |
| 35 | Supplying, erectingandmarkingdoublepole isolatoronlyswitchversionofminiaturecircuitbreakerof40Awith requiredwiring connections and lugs etc. inprovideddistributionboard. |
| 36 | C - SECTION : MATERIAL TESTING COST Sand: Sand Fineness Modulus, Silt Content |
| 37 | TMT Steel: Upto 16mm Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress. |
| 38 | Murum: Atterberg Limits; Liquid Limit & Plastic Limit Testing |
| 39 | Truss Steel Anti Corrosive Test: Resistance to applied Voltage. ( 1 Hr. Test ) (Set of 2 Bars) |
| 40 | Concrete: Compressive Strength OF C.C. Cube(Set of 3 cubes). |
| 41 | Basic Test of Cement: Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness. |
| 42 | BASIC TEST OF AGGREGATE.Water Absorption, Specific Gravity,Impact Value, Crushing Value |
| 43 | BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks). |
| 44 | D - SECTION : ROYALTY COST Add Royalty For Sand as per Statement Attached |
| 45 | Add Royalty For Above 40 mm, Murum Material as per Statement Attached |
| 46 | Management Strategies and Implementation Plan (MSIP) to manage the Environmental, Social, Health and Safety (ESHS) risks and ESHS Code of Conduct Please Enable Macros to View BoQ information |