| 1 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point.GROUP A |
| 2 | GROUP-B |
| 3 | GROUP-C |
| 4 | Replacement of ight point/Fan point/ Exhaust fan point/Call bell point with 6Amp ,250V Modular switch /shocket of make (Make-Legrand(Myrius), Schneider (Zencelo) ,Panasonic (Vision) or equievalant reputed make & model ISI marked marked mounted on Metal box having front Modular cover of suitable size, Metal box including all accessories and connection (Make of wire-Finolex/L&T/Anchor /Havells/V-Guard) |
| 5 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) . |
| 6 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make- Legrand (Myrius), Schneider(Zencelo), Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 7 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch (modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 8 | Supplying,fixing of 1x6A+1X16A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) (Make-Legrand(Myrius), Schneider(Zencelo), Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 9 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(Myrius), Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 10 | Supplying and fixing following rating RCBOs/ MCBs in the existing DB complete with connections,testing and commissioning etc. as required |
| 11 | 63 Amps4P, 100 MA RCCB |
| 12 | 63 Amps4P, 10 KA FP MCB |
| 13 | 32 Amps DP,10 KA MCB |
| 14 | 6 Amp to 32 Amp, 10 KA SP MCB (C-Curve)Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 15 | 25 mm |
| 16 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic FRLS heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 17 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 18 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit . (2X4+1X1.5) |
| 19 | 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) |
| 20 | 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(4X10+2X6) ( Floor power panel to PDB & UPS Panel to floor UPS DB)) |
| 21 | Cable S/F of 6 sq.mm 2 Core Alluminium, armoured LT power Cable main insulated 650/1100 grade(make-Havells/Polycab) |
| 22 | S/F of 16 sq.mm 4 Core Alluminium, armoured LT power Cable main insulated 650/1100 grade(make-Havells/Polycab) |
| 23 | S/F of 35 sq.mm 3.5 Core Alluminium, armoured LT power Cable main insulated 650/1100 grade(make-Havells/Polycab) |
| 24 | S/F of 95 sq.mm 3.5 Core Alluminium, armoured LT power Cable main insulated 650/1100 grade(make-Havells/Polycab) |
| 25 | Cable traySupplying instalaltion hot dip galvanized ladder type cable tray of following size including installation along wall/ suspended from ceiling with brackets/ threaded suspenders including bends etc as required.150 mm (W) X 50 mm (H) with 1.6 mm thick sheet |
| 26 | 250W LED Sports Light fitting (>=28000 Lumen) with 80CRI (4KV inbuild & 10KV external surge protection, IP66, Aluminium die cast body,cool white-(5600K to 6500K),Impact resistance of IK08, Over current, short circuit, over voltage , dust & water protection, entire luminarie should act as Heat shrink(LED life>50000 burning hour),The fixture must have 3-4mm thick safety glass cover with BIS Certified driver of IP67 protection & Driver of make Moso/Inventronics/Sosen or equivalent. Light Fixture of make Bajaj or Equivalent of Philips/ DISANO/Abacus. |
| 27 | Surface LED Light fitting (2000Lumen) of make BAJAJ (CAT No:BCLAB 20w WH LED P ) or Equivalent /Philips/ Lighting Technologies. |
| 28 | Surface/Recess LED Light fitting (1500 Lumen) of make BAJAJ (CAT No:BGSLO SLEEK SURFACE 15W WH SQ) /or Equivalent of Philips/ lighting technologies catagory ISI marked as per direction of Engineer in charge . |
| 29 | Surface/Recess LED Light fitting (800 Lumen) of make BAJAJ (CAT No:BGSLO SLEEK SURFACE 8W WH SQ) / or Equivalent of Philips/ lighting technologies catagory ISI marked as per direction of Engineer in charge . |
| 30 | Repair and maintainance of direct driven Tube axial type ventilator fan and casing suitable for smoke exhaust application ( @ 10% ) |
| 31 | LED Bulk head Light fitting (1000 Lumen) of make BAJAJ 10W LED)/ Equivalent of Philips/Lighting Technologies. as required |
| 32 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement warranty shall be 2 years. Make-Havells/Bajaj/Usha/Crompton /Orient |
| 33 | S/F of 9' fibre exhaust fan with fixing including all accessories of USHA//Bajaj/Crompton / Havellsmake & connection as per direction of Engineer-in-charge. |
| 34 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery 215(m3/min) Make-USHA(Technix)/Crompton(Energion Groove) /Havells (Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge, |
| 35 | S/F of Wall Mounted Fan including all accessories of USHA(Mist Air Icy Blue) /Crompton (Wall Mounted Fan-High Flo LG 18) make & connection as per direction of Engineer-in-charge. |
| 36 | S/F.of 600 mm high speed Ceiling Fan with fixing including all accessories of USHA//Bajaj/Crompton / Havellsmake & connection as per direction of Engineer-in-charge. |
| 37 | S/F of double battery of 150AH with 2KVA Inverter of Make Luminous/Exide /Sfsonic including all accessories and connection as per direction of Engineer-in-charge. |
| 38 | S/F of 40 KVAOil Cooled Servo Stabilizer.StandardIS:9815 Standards3.TypeUn-Balanced Type Three phase Oil Cooled.4.Rating 40 KVA Three Phase5.Input Voltage Range 280V 460V Volts (Phase to Phase)6.Output Voltage Range 400 / 415 Volts±17.Input Frequency45-55 Hz8.Response Time10m sec.9.Correctionspeed35 to 45 Volt per sec.10.EfficiencyBetter than 9811.Metering / ControlDigital / Analog AC Voltmeter with Input & Output measure switch, Ampere Meter with selector switch for Three phases.12.CORE USEDCRGO CORE WITH MITRED JOINTS FOR BUCK BOOST TRANSFORMER.13.windingElectrolytic Copper Grade( F Class Insulated)14.Temp. Rise35 C Deg. Cent. Above Ambient15.Winding Temp. Rise40 C Deg.16.ApplicationINDOOR TYPE17.Transformer Oil (MAKE)IS 335 making (Power Oil)18.Output Accuracy+/- 1 from No Load to full load.19.WaveForm DistortionVirtually Nil20.Losses at No Load.12% of the total capacity21.Losses at full load0.7 at full load22.TerminationsSuitable Bus Bars will be provided in the Termination box.23.Operating Temp0 to 55 degree centigrade |
| 39 | Repair, Renovation, Testing and Commissioning of Existing 400A LT Main Distribution Panel Repair, renovation, servicing, testing and commissioning of existing 400A LT Main Distribution Panel including dismantling of damaged/defective components, replacement of switchgear accessories, busbar supports, internal wiring, cable terminations, panel hardware, indicating lamps, selector switches, control fuses, metering units, measuring instruments, current transformers (if required), voltmeter, ammeter, multifunction meter, MCBs/MCCBs, contactors, relays and other associated switchgear items complete as required. The work shall include cleaning, rust treatment, repainting of panel structure, tightening of all electrical connections, insulation resistance testing, functional testing and commissioning of the panel complete in all respects as per the direction of Engineer-in-Charge. |
| 40 | Supply of 1.5 Ton 3 star BEE rating 2024 rated split Air conditioners of make (Carrier/Blue Star/LG make).or equivalent make. |
| 41 | Supply of 2 Ton 3 star BEE rating 2024 rated split Air conditioners of make (Carrier/Blue Star/LG make).or equivalent make. |
| 42 | Installation and fixing of AC machine |
| 43 | 4KVA,12Amp voltage Stabilizer of voltage range 90 V to 300V,Digital wall mounted 12 A of V-guard/Shakti/Luminous/Microtek make |
| 44 | 5KVA,15Amp voltage Stabilizer of voltage range 90 V to 300V,Digital wall mounted of V-guard/Shakti/Luminous/Microtek make |
| 45 | S/F of MS outdoor stand |
| 46 | Supply, Instalaiton, testing and commission of 11/8\\" Dia SOFT COPPER REFRIGERANT PIPING OF 18 swg insulated with 19mm thick nitrle rubber tubes as insulation material. |
| 47 | Supply, Instalaiton, testing and commission of 5/8\\" Dia SOFT COPPER REFRIGERANT PIPING OF 18 swg insulated with 19mm thick nitrle rubber tubes as insulation material. |
| 48 | Repairing, Servicing, Testing and Commissioning of 2 Ton Split Type Air ConditionerRepairing, servicing, testing and commissioning of existing 2 Ton Split Type Air Conditioner unit including inspection and rectification of faults in indoor and outdoor units, cleaning of evaporator and condenser coils, servicing of blower motor and condenser fan motor, checking and replacement of defective capacitors, contactors, relays, thermostat, sensors, PCB, drain pipe and other accessories as required. The work shall include checking of refrigerant leakage, vacuuming, gas charging/top-up (if required), tightening of electrical connections, insulation testing, performance testing and commissioning of the unit complete in all respects as per the direction of Engineer-in-Charge. |
| 49 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA 568 C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20 to 70C Cable support Conductor Resistance 9.38 100m Max., Cable support Delay Skew: 45 ns/100m, Operating Voltage: 72V Impedance: 100 15 100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax/ Legran/ Panduit |
| 50 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN LowLight IR Fixed Lens Dome/Bullet Camera, 1/2.8 CMOS or better, 5MP (2592 x 1944) 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5, V:73.8 (dome)/ Field of View FoV H:94.1, V:71(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion,& People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption,2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : 30 C to 60 C. Certifications: ONVIF Profile S/G/T compliant, CE (EN 50130 4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 51 | Repair, Maintenance, Testing and Commissioning of Existing CCTV Surveillance SystemRepair, maintenance, testing and commissioning of existing CCTV Surveillance System including inspection and rectification of faults in CCTV cameras, DVR/NVR, SMPS, hard disk, network switches, power supply units, connectors, cables, monitor and associated accessories. The work shall include cleaning of cameras and equipment, checking and tightening of electrical and network connections, replacement of defective minor components, configuration of DVR/NVR settings, restoration of recording and monitoring functions, testing of video quality, data storage and network connectivity, and commissioning of the complete system in all respects as required and as directed by the Engineer-in-Charge. |
| 52 | Refilling of ABC 6 kg type fire extinguisher . |
| 53 | Refilling of Co2 4.5 kg type fire extinguisher . |
| 54 | S/F of 1x90W 5700K LED street light made up of pressure die cast housing with toughned glassindividual high powered LEDs with secondary optics ,IP66 protection Havells make(ENDURA PLUS )/Crompton ORION NEO including all accessories,G.I bracket and connection. Please Enable Macros to View BoQ information |