| Sl. No. | Item Description |
| 1 | Supplying of 5 A to 30 A rating, 240/415 V, 10 kA, \\"B\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 2 | 30A 4P,MCB 'B Curve' |
| 3 | 10A 2P, MCB 'B Curve' |
| 4 | Supplying of 5 A to 63 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 5 | 63A 4P,MCB 'C Curve' |
| 6 | 20A SP, MCB 'C Curve' |
| 7 | 30 A 3P MCB 'C Curve\\" |
| 8 | Supplying of 5 A to 63 A rating, 240/415 V, 10 kA, \\"D\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 9 | 63A 4P,MCB 'D Curve' |
| 10 | 20A 2P, MCB 'D Curve' |
| 11 | 16A 2P, MCB 'D Curve' |
| 12 | 25A 2P, MCB 'D Curve' |
| 13 | 30A 4P,MCB 'D Curve' |
| 14 | Supplying of following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | 25 A 2P RCCB (100 mA) B Curve |
| 16 | Supplying of following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | 40 A 2P RCCB (300 mA) 'C Curve' |
| 18 | Supplying of following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | 40 A 2P RCCB (300 mA) 'D Curve' |
| 20 | Supplying of MCCB of the following rating, breaking capacity, and number of poles, complete with thermomagnetic release and terminal spreaders. The MCCB shall have Ics = 100% of Icu and a rated operational voltage of 690 V, comolete in all resoects. as required |
| 21 | 125 A,36KA,FP MCCB |
| 22 | Supply & Fixing of Front Cover (SS 304 MATT FINISH) & Base Plate in existing modular wall and with its all accessories. |
| 23 | Existing Switch & Socket outlets shall be housed in existing box/enclosure. The enclosure shall be made from CRCA and front cover plate shall be made from SS 304. The whole assembly shall be concealed in such a way that the SS 304 front cover plate is properly aligned & flush with the wall. The SS 304 Cover Plate shall be matt finish. switch make suitable for MK make. |
| 24 | 1/2 module front Cover(SS 304 MATT FINISH) & rear plate. |
| 25 | 3 module front Cover(SS 304 MATT FINISH) & rear plate. |
| 26 | 6 module front Cover(SS 304 MATT FINISH) & rear plate. |
| 27 | EARTHING Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value. |
| 28 | Earth Pit :Supply and installation of earthing station as per IS standard complete with 600x600x3.15mm Copper plate earthing electrode plate, salt, charcoal, 2 nos. 50x6 mm Copper Conductor up to test link, 40 mm dia G.I. watering pipe with funel,test link. The earthing chamber size shall be 450x450 mm with C.I. Manhole chamber etc. The identification number shall be provided both inside and outside of equipment. The scope also includes the supply of Bi-metallic plate (COPAL) to connect the earthing electrodes with grid earthing strip.Necessary SS nut & bolt should be supplied by the contractor for fixing the strips to pit if required. |
| 29 | Chemical Earth Pit :Supply and installation of 3.0 mtrs. long 50 mm dia hot dip galvanized Pipe in Pipe type Chemical earthing station complete as per standard drawing .The contractor has to make a 3.5 mtr deep 450 mm dia bore in hard rock/soft soil, fill the outer side 100 mm dia. Of the bore with Black cotton soil and Balance 250 mm dia bore and 2900 mm deep shall be filled Chemical earth electrodes treatment as per standard. The chamber size shall be fitted with 450 x 450 mm with heavy duty C.I. chamber Cover duly painted and marked with Pit Identification Number both inside and outside. The identification number shall be provided both inside and outside of equipment. The scope also includes the supply of Bi-metallic plate to connect the earthing electrodes with grid earthing strip. Chemical earth pit shall be Ashlok or Equivalent makes as mentioned in approved makes of Chemical Earth Pits.Necessary SS nut & bolt should be supplied by the contractor for fixing the strips to pit if required. |
| 30 | Chemical Earth Pit : Supply and Installation of 3.0 mtrs. long 80 mm dia hot dip galvanized Pipe in Pipe type.The supply includes suitable type chemical for earthing.The contractor has to make a 3.5 mtr deep 450 mm dia bore in hard rock/soft soil, fill the outer side 100 mm dia. Of the bore with Black cotton soil and Balance 250 mm dia bore and 2900 mm deep shall be filled Chemical earth electrodes treatment as per standard drawing . The chamber size shall be fitted with 450 x 450 mm with heavy duty C.I. chamber Cover duly painted and marked with Pit Identification Number both inside and outside . The identification number shall be provided both inside and outside of equipment. The scope also includes the supply of Bi-metallic plate to connect the earthing electrodes with grid earthing strip. Chemical earth pit shall be Ashlok make or Equivalent makes as mentioned in approved makes of Chemical Earth Pits if required.Necessary SS nut & bolt should be supplied by the contractor for fixing the strips to pit. |
| 31 | Chemical Earth Pit :Installation & Laying of existing 3.0 mtrs. long 80 mm dia hot dip galvanized Pipe in Pipe type Chemical earthing station.The contractor has to make a 3.5 mtr deep 450 mm dia bore in hard rock/soft soil, fill the outer side 100 mm dia. Of the bore with Black cotton soil and Balance 250 mm dia bore and 2900 mm deep shall be filled Chemical earth electrodes treatment . The chamber size shall be fitted with 450 x 450 mm with heavy duty C.I. chamber Cover duly painted and marked with Pit Identification Number both inside and outside as per Earthing Layout Drawing. The identification number shall be provided both inside and outside of equipment. The scope also includes the supply of Bi-metallic plate to connect the earthing electrodes with grid earthing strip. Chemical earth pit shall be Ashlok make or Equivalent makes as mentioned in approved makes of Chemical Earth Pits.Supply of suitable type chenical is under the scope of contractor. Necessary SS nut & bolt should be supplied by the contractor for fixing the strips to pit if required. |
| 32 | EARTHING STRIPS/WIRES:Installation & laying of GI earth conductor bar / flexible wire /strip of following sizes along the cable trenches or cable trays or fixing to walls or structures or below the slab , burries individually in paved/unpaved areas and minor civil work finishing after laying of earthing strips etc. The installation shall include drilling of holes, connection & crimping of adequate lugs, clamping, hardware material, etc. All Hardware shall be as per the MOC of Earthing strip. |
| 33 | Excavation & backfilling of soil for burying the strip wherever applicable is paid extra as per the rate of excavation and backfilling rate. Earth Bus 450 mm x \\"T\\" mm (T As per earthing strip size shall be provided at every 20 meter interval for main earthing strip and every drop of cable to equipment from cable tray under instruction of engg. in charge and jumper. |
| 34 | GI Earthing Jumper shall be provided at every 20 Mtr. length of Earth strips and every drop of cable , Earthing Jumper size :- 250 mm long x \\"T\\" mm Thickness with 4 nos. of M10 drilled hole to connect flexible copper wire ( 35 or 25 mm² , 25 or 15 mm² , 15 or 10 mm² Stranded Copper PVC Insulated Earth wire (Cripped both end by Compression cable lug) , Flexible wire shall be paid extra. |
| 35 | 75 x 10 mm GI Earthing strip |
| 36 | 50 x 6 mm GI Earthing strip |
| 37 | 30 x 6 mm GI Earthing strip |
| 38 | 25 x 6 mm GI Earthing strip |
| 39 | 25 x 3 mm GI Earthing strip |
| 40 | Excavation in all sorts of soils for required depth and put earthing strip then back filling with soil. Contractor's scope of work under this item shall be include disposal of surplus earth and levelling, shuttering and dewatering if required. 'Excavation shall be done as per directions of Engineer-in-charge. Minimum depth for excavation is 500 mm. |
| 41 | Supply and installation of Earth tag box with 4 Nos. of Earthing stud ( 10 mm dia and MOC SS 304 ). The Earthing Strip shall be housed in enclosure The enclosure and front cover palte shall be made from SS 304. The whole assembly shall be concealed in such a way that the SS 304 front cover plate is properly aligned & flush with the SS 304 Box. The SS 304 Cover Plate and enclosure shall be matt finish. The errection rates shall include fixing of enclosures on surface of wall. |
| 42 | Supply and installation of 4.0 Sqmm Flexible wire with both side crocodile clamp |
| 43 | Supplying of 1.1 KV Grade LT PVC insulated multi stranded type Copper conductor PVC flexible cable as per the specification. All the cable shall be FRLSH type. Also all cable shall be multi stranded copper conductor (Class-2 or 5 ) and as per Indian colour coding. |
| 44 | FLEXIBLE CABLE |
| 45 | Supplying of '3C x 1.5 mm² LT PVC insulated multi stranded type Copper conductor PVC flexible cable. |
| 46 | Supplying of '3C x 2.5 mm² LT PVC insulated multi stranded type Copper conductor PVC flexible cable. |
| 47 | Supplying of '5C x 4 mm² LT PVC insulated multi stranded type Copper conductor PVC flexible cable. |
| 48 | Supplying of '5C x 6 mm² LT PVC insulated multi stranded type Copper conductor PVC flexible cable. |
| 49 | Supplying and Laying |
| 50 | Supply and laying of 5 C X x 2.5 mm² LT PVC insulated multi stranded type Copper conductor PVC flexible cable. |
| 51 | Supply and laying of 1 C x 6 sq.mm LT PVC insulated multi stranded type Copper conductor PVC flexible cable with its all aceesories Green colors |
| 52 | Supply and laying of 1 C x 10 sq.mm LT PVC insulated multi stranded type Copper conductor PVC flexible cable with its all aceesories |
| 53 | Supply and laying of 1 C x 16 sq.mm LT PVC insulated multi stranded type Copper conductor PVC flexible cable with its all aceesories |
| 54 | Supply and laying of 1 C x 25 sq.mm LT PVC insulated multi stranded type Copper conductor PVC flexible cable with its all aceesories |
| 55 | Supply and laying of 1 C x 35 sq.mm LT PVC insulated multi stranded type Copper conductor PVC flexible cable with its all aceesories, cable green. |
| 56 | Supply and laying of 1 C x 50 sq.mm LT PVC insulated multi stranded type Copper conductor PVC flexible cable with its all aceesories |
| 57 | Supply and laying of 1 C x 70 sq.mm LT PVC insulated multi stranded type Copper conductor PVC flexible cable with its all aceesories |
| 58 | ARMOURED CABLEs |
| 59 | Laying, installation and commissioning of 3.5C x 25 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 60 | Laying, installation and commissioning of 3.5C x 35 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 61 | Laying, installation and commissioning of 3.5C x 50 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 62 | Laying, installation and commissioning of 3.5C x 70 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 63 | Laying, installation and commissioning of 3.5C x 95 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 64 | Laying, installation and commissioning of '4C x 15 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 65 | Laying, installation and commissioning of '3C x 15 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 66 | Laying, installation and commissioning of '4C x 10 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 67 | COPPER LUGS |
| 68 | Supply and fixing of 6 sq.mm copper cable lugs (ring type) made from high conductivity electrolytic copper, suitable for termination of 6 sq.mm cables, conforming to relevant IS standards. |
| 69 | Supply and fixing of 10 sq.mm copper cable lugs (ring type) made from high conductivity electrolytic copper, suitable for termination of 10 sq.mm cables, conforming to relevant IS standards. |
| 70 | Supply and fixing of 16 sq.mm copper cable lugs (ring type) made from high conductivity electrolytic copper, suitable for termination of 15 sq.mm cables, conforming to relevant IS standards. |
| 71 | Supply and fixing of 25 sq.mm copper cable lugs (ring type) made from high conductivity electrolytic copper, suitable for termination of 25 sq.mm cables, conforming to relevant IS standards. |
| 72 | Supply and fixing of 35 sq.mm copper cable lugs (ring type) made from high conductivity electrolytic copper, suitable for termination of 35 sq.mm cables, conforming to relevant IS standards. |
| 73 | Supply and fixing of 50 sq.mm copper cable lugs (ring type) made from high conductivity electrolytic copper, suitable for termination of 50 sq.mm cables, conforming to relevant IS standards. |
| 74 | Supply and fixing of 70 sq.mm copper cable lugs (ring type) made from high conductivity electrolytic copper, suitable for termination of 70 sq.mm cables, conforming to relevant IS standards. |
| 75 | Supply and fixing of 10 sq.mm copper cable lugs (pin type) made from high conductivity electrolytic copper, suitable for termination of 10 sq.mm cables, conforming to relevant IS standards. |
| 76 | Supply and fixing of 16 sq.mm copper cable lugs ( pin type) made from high conductivity electrolytic copper, suitable for termination of 15 sq.mm cables, conforming to relevant IS standards. |
| 77 | Supply and fixing of 25 sq.mm copper cable lugs (pintype) made from high conductivity electrolytic copper, suitable for termination of 25 sq.mm cables, conforming to relevant IS standards. |
| 78 | CABLE END TERMINATIONS :- |
| 79 | Termination of PVC/XLPE insulated armoured cables and connection of leads including the supply of HT Termination Kit ,cables glands , lugs ,cutting, stripping of cable insulation, drilling of gland plate, fixing of cable gland, crimping the lug on to the conductor, supply, fixing & marking with number ferrules etc. All necessary GI consumables & hardware, including all labour and materials complete as per approved drawings, directions of Engineer-In-Charge. Scope will also include provision of additional supports, if required, with steel for proper dressing & support of cables, specification and directions of Engineer-In-Charge.120 Sqmm and above Cable lug shall be double barrel type |
| 80 | LT INDOOR TERMINATION :- FOR ALU CABLES |
| 81 | Supply and installation of the indoor terminations with Double compression heavy duty type Brass-Nickel cable gland , lugs & PVC Shrouds. , etc. complete as required. |
| 82 | Supply and installation of the indoor terminations with Double compression heavy duty type Brass-Nickel cable gland , lugs & PVC Shrouds. , etc. complete as required. |
| 83 | 3.5C x 95 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 84 | 3.5C x 70 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 85 | 3.5C x 50 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 86 | 3.5C x 35 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 87 | 3.5C x 25 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 88 | 4C x 15 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 89 | 3C x 15 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 90 | 4C x 10 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 91 | 3C x 10 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 92 | 4C x 6 mm² LT XLPE (2XWY) insulated Copper conductor PVC outer sheathed Armoured cable. |
| 93 | FLEXI-BRAID CABLE -LT OUTDOOR WEATHERPROOF TERMINATION :-POLYMIDE PG TERMINATION :- |
| 94 | Supply & installation of Polyamide PG cable gland , lugs etc. complete as required.(Similar to \\"SKINTOP STR in LAPP make) |
| 95 | 5G x 2.5 mm² LT PVC insulated multi stranded type Copper conductor PVC flexible cable. |
| 96 | 5G x 4 mm² LT PVC insulated multi stranded type Copper conductor PVC flexible cable. |
| 97 | 5G x 6 mm² LT PVC insulated multi stranded type Copper conductor PVC flexible cable. |
| 98 | STRAIGHT JOINTS :- |
| 99 | Supply & Installation of Straight Through Joints LT Cable: Making straight through joint including supply of jointing kits, with heat shrinkable or equivalent type jointing kit of cables of following sizes including arranging of all necessary GI consumables, ferrules, hardware, labour. Job includes all standard tests, as specified. Scope includes Supply , transportation , unloading , shifting , resifting kits from owner’s issue point to actual place of work and installation with contractor's own lifting and transporting arrangement. |
| 100 | ALLUMINIUM CONDUCTOR ARMOURED CABLEs |
| 101 | 3.5C x 35 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 102 | 3.5C x 25mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable. |
| 103 | GI PRE-FABRICATED CABLE TRAY :- |
| 104 | Supply , transport , unloading , shifting & installation in horizontal & vertical formation of prefabricated perforated type galvanised sheet steel cable trays of different widths and delivered in standard lengths along with Coupler plates and requisite number of hardwires at different levels. The Contractor's scope is inclusive of lifting & placing of trays on supports at different levels, aligning, joining of trays with couplers, clamping/ fastening to the support of the vertical portions and wherever required. Necessary bends (horizontal/ vertical), tees, cross, elbows, reducers, etc., is under the scope of contractor. |
| 105 | Gas cutting of cable trays at site is not permitted. If any welding is to be done on cable trays applying of two coats of zinc rich primer and one coat of Silver paint at the modified/ repaired area/ portions and erection of the same. Cable tray below 450 mm width shall be installed on threded rod with slotted C channel between two parallel rods arrangment , This support arrangement will be supplied by contractor. All the necessary modifications, addition, removal of supports, brackets, cleats, etc., minor civil works for grouting and entries are to be carried out as and where required and is under the scope of Contractor. |
| 106 | The scope of work includes transportation of materials from owner's issue point to actual place of work by contractor's own lifting and transportation arrangement. |
| 107 | Cable tray shall be hot dipped galvanized and minimum thickness of GI coating is 90 to 100 Microns. Thickness of perforated cable tray sheet steel for 50 mm to 300 mm cable tray = 2.0 mm thick and minimum height of the perforated cable Tray is 35 mm. Cable tray shall be in different widths and shall be in standard length 2500 mm long and suitable to couple two cable trays with coupler. |
| 108 | 100mm (W) x 50 mm (H) wide cable tray perforated type/Ladder type |
| 109 | 150mm (W) x 50 mm (H) wide cable tray perforated type/Ladder type |
| 110 | 200mm (W) x 50 mm (H) wide cable tray perforated type/Ladder type |
| 111 | Supply of Ceiling rose with its all accessories |
| 112 | Supply and fixing of Sand buckets with floor stand and sand (set of 4 buckets of 9 Ltr. capacity) Stand size : 1.5 M x 0.9 M x 0.6 M stand shall be painted with epoxy paint as per IS requirement. |
| 113 | Supply and fixing of Caution boards ( 433V) |
| 114 | Supply and fixing of Danger notice board for the High Voltage & Low Voltage Installation |
| 115 | Provide comprehensive maintenance and replacement services for 11 kV switchyard equipment at the substation, including replacement of AB switch male and female contacts, replacement of jumper connections, inspection and replacement of outgoing 11 kV fuse contacts, checking and servicing of lightning arresters, and checking of pin and disc insulators (supply and installation of all required replacement parts, materials, consumables, labor, tools, safety equipment, and waste disposal as per relevant standards like IS/IEC) |
| 116 | MCB DISTRIBUTION BOARDS :- |
| 117 | Supply Installation, testing and commissioning of following MCB distribution boards. Also Job includes termination of incoming and outgoing cables, drilling of gland plate and shall be completely wired up to incoming and outgoing terminals by PVC insulated flexible copper wire /cable of adequate rating. The Distribution Board shall be readymade type. |
| 118 | Note: The rates for the following items shall include installation of MCCBs, MCBs, RCCBs or RCBOs along with all necessary fixing accessories like mounting screws, doors, locks, din rails, bus bars, blank plates for all the unused outgoing ways, etc., all complete as required. (All TDPB shall have minimum Fault withstand capacity is 25 KA) |
| 119 | LDBs and SLDBs |
| 120 | 3 Phase, 12 WAY Distribution Board with Horizontal Double door type with per phase isolation kit, 30A 4P MCB as a incomer , 25A-100 mA DP RCCB per phase & 12 Nos. 10A DP MCB as a outgoing circuit (4 Way per Phase).MCB shall be provided with “B” curve.SLDB-1 ETP& STP Block, |
| 121 | 1 Phase, 2 Raw of 13 Module Distribution Board with Horizontal Double door type (Flexi DB) with 30A DP MCB as a incomer , 30A-300 mA DP RCCB & 8 Nos. 15A DP MCB and 4 Nos. 20A DP MCB as outgoing circuit. MCB shall be provided with “D” curve. UPSDB,SELDB,ETP& STP Block, |
| 122 | 8 WAY Three phase Distribution Board with Vertical Single door type (VTPN DB) with 125A 4P MCCB as a incomer & 8 Nos. 30A TP MCB as outgoing circuit with top and bottom Adaptor Box. MCB shall be provided with “C” curve. ETP &STP |
| 123 | 3 Phase, 6 WAY Distribution Board with Horizontal Double door type with per phase isolation kit, 63A 4P MCB as a incomer , 40A-300 mA DP RCCB per phase & 3Nos. 15A SP MCB and 9 Nos. 9 A SP MCB as a outgoing circuit (6 Way per Phase).MCB shall be provided with \\"C\\" curve.SPDB-1 ETP& STP |
| 124 | Supply, installation, testing, and commissioning of DOL (Direct On-Line) starters and panel suitable for 5.5 kW three-phase motors (415V AC, IP55 surface mounting enclosure), complete with thermal overload relays, contactors, manual reset pushbuttons (ON/OFF/STOP), indicator lights, and provision for remote control terminals. Includes all internal wiring, busbars, cable terminations (with proper glands and lugs for incoming power and motor leads), earthing, and painting for corrosion resistance as per IEC 60947 standards.a) Raw water collection tank STP motor - 5.5 KW b) Raw water collection tank ETP motor - 5.5 KW c) Rabies STP- 5.5 KW d) Rabies ETP - 5.5 KWe) BCG - 5.5 KW |
| 125 | Wiring in MS Heavy duty Conduits and Floor / wall Raceways |
| 126 | Wiring shall include fixing and installation of all necessary Heavy duty MS conduits (Heavy duty MS conduits will be supplied by HBL) with GI pull wire, conduit fittings, conduit accessories like saddles, spacers, bends, couplings, collars etc., junction / pull / inspection boxes, flexible FRLS wires, conduit supports, bushings lamp holders, ceiling rose, flexible conduit/ inspection L bends, wherever required & terminations using tinned copper lugs of crimping type. A point wiring shall include in addition the earth continuity conductor/wire from the DB to the earth pin/stud of the outlets/switchbox & to the outlet point. |
| 127 | Installation of MS conduit and accessories along the wall/ column/ true/ false ceiling/ floor/Cable tray /walkable false ceiling/ roof structure as per site requirement including cutting bending & coupling as per specification, general engineering practice/standard, and as per direction of Engineer-In-Charge, to complete the work in all respect and to make ready the system to hand over for operation / utilization. |
| 128 | The method of laying of conduit will be surface / concealed as per site requirement. The scope of the work is including of fixing necessary spacing bars/ saddle as specified, tying of the conduit with reinforced rods, chipping along the wall fixing chicken mesh and making good surface of wall as required at site. The detailed conduit layout preparation for aesthetic look will be in contractor scope. |
| 129 | Note :- The rate includes the Chesaling( jerry work ) of wall, after fixing conduit levelling of wall and making good surface (filling) where ever required. |
| 130 | LIGHTING POINTs :- |
| 131 | For single phase power point, wiring from DB to the first point shall be done using 4 sqmm copper conductor 660/1000V grade PVC insulated FRLS flexible wire in heavy duty MS conduit and Floor/Wall raceways. Maximum three points can be looped & looping shall be with 4 Sqmm wire. AC point shall not be looped. Separate wire 2.5 sqmm shall be used for earthing of all sockets etc. |
| 132 | Total point wiring shall be in Mtrs |
| 133 | Point wiring for lighting system , wiring from SLDB to Lighting Switch Board (Mains) to first fitting and first fitting to subsequent fitting including looping between switch to switch wherever required. |
| 134 | Point wiring for Sockets outlets , wiring from SPDB/Power Panel to First Switch socket , looping from first switch socket to subsequent switch sockets wherever required. |
| 135 | MS Conduits and Raceway will be supplied by HBL |
| 136 | Supply & Laying of 1.5 mm² PVC FRLSH wire in MS Conduits/Raceways |
| 137 | Supply & Laying of 2.5 mm² PVC FRLSH wire in MS Conduits/Raceways |
| 138 | Supply & Laying of 4.0 mm² PVC FRLSH wire in Ms Conduits/Raceways |
| 139 | SUPPLY & INSTALLATION OF SWITCH BOXES AND SWITCH SOCKET ( CONCEALED IN WALL/PARTITION ) |
| 140 | The Switches and Socket outlets shall be concealed on Modular partition wall / on Furniture / On Floor Raceways /Wall raceways / Brick wall and front plate shall be poly carbonate type. |
| 141 | 10 Amp Switch 1 nos. in 1/2 module CRCA box with front & rear plate. |
| 142 | 10 Amp Switch 2 nos. in 2 module CRCA box with front & rear plate. |
| 143 | 10 Amp Switch 3 nos. in 3 module CRCA box with front & rear plate. |
| 144 | 10 Amp Two Way Switch 1 nos. in 1/2 module CRCA box with front & rear plate. |
| 145 | 10 Amp Two Way Switch 2 nos. in 2 module CRCA box with front & rear plate. |
| 146 | 10 Amp two way Switch 3 nos. in 3 module CRCA box with front & rear plate. |
| 147 | 6/15 Amp Switch socket 1 nos. in 3 module CRCA box with front & rear plate. (\\"F & UF&AC\\" type socket outlets) |
| 148 | 6/15 Amp Switch socket 2 nos. in 6 module CRCA box with front & rear plate.(\\"F1/F2 & UF1/UF2 type socket outlets). |
| 149 | 6/15 Amp Socket 9 nos. with 1 Nos. of Switch (6+6+4+3) CRCA box with front & rear plate.(\\"UPS1 type socket outlets). |
| 150 | CHIPPING (CHASING) OF WALL , SLAB , BEAM ETC.:- |
| 151 | Chipping of wall , slab , beam (50 mm x 50 mm ) etc. installation of pipes/cables and making good the surface as required. This item shall be applicable for concealed cabling. |
| 152 | Chasing of brick wall |
| 153 | Chasing of RCC wall |
| 154 | FAN FITTINGS |
| 155 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.. |
| 156 | CEILLING FANS:- |
| 157 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 158 | WALL MOUNTING FANS:- |
| 159 | SITC of 400mm sweep wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation. similar to WINDFLO in CG make |
| 160 | PEDESTAL FANS:- |
| 161 | SITC o 450 mm pedestal fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories |
| 162 | EXHAUST FANS:- |
| 163 | SITC of 250mm sweep Exhaust Fan, 900rpm light duty exhaust fan shutter type white colour, 9\\" or 10\\" star rated as per BEE, with its all accessories including mounting as required for complete installation. |
| 164 | LIGHT FITTING :- |
| 165 | Supply & Installation, testing & commissioning of standard light fittings and lighting accessories including lamp. The scope shall includes own lifting & transporting arrangement , unpacking assembly of luminaries, providing of all hardware such as lighting supports, nuts, anchor fasteners, bolts, screws, cleats, clamps, Junction box, PVC insulated wires / cables from Junction box to lighting fixtures,ceilling roses ball and socket arrangement with J.B., suspension conduit pipe 1.5 m long. |
| 166 | 100 W Led Flood Light fixture with intergral ballast with all accessories Cable entry at Side of the fitting in Loop in Loop out arrangment . The Light fixture shall be mounted on Fabricated support with all hardware and Fitting shll be minimum IP 65 Installation:- Wall Mounting Utility & ETP & STP |
| 167 | 200 W Led Flood Light fixture with intergral ballast with all accessories Cable entry at Side of the fitting in Loop in Loop out arrangment . The Light fixture shall be mounted on Fabricated support with all hardware and Fitting shll be minimum IP 65 Installation |
| 168 | Supply, Installation, Testing & Commissioning of 90W ±10% LED Street Light Luminaire1 No. 90W ±10% LED Street Light luminaire, IP66, IK08 with system efficacy >115 lm/W. Die cast aluminium housing in square shape with separate hermetically sealed compartments for LEDs and driver (IP66). Optical compartment IK08 impact rated; control gear with die cast aluminium safety cover. LM-80-08 compliant LEDs (Nichia/Cree/Lumiled/Citizen/Osram/Seoul/Bridgelux), EN 62471 photobiological safety (RG2 max) certified, 5-year LED manufacturer association certificate. Max junction temp 125°C, operating ≤90°C at 35°C ambient. Optical grade PC lens (individually fixed to MCPCB, not glue; >85°C withstand, >90% transmissivity) for street light distribution. CCT 5700K, CRI ≥70, L70 50,000hrs at max current/105°C case (10,000hr LM80 report). BIS registered, multistage isolated potted CC driver (150-300V, 6kV surge protection, PF >0.95, THD <10%, integral short circuit/overvoltage protection). Complete with supply, installation, testing & commissioning |
| 169 | Supply, Installation, Testing & Commissioning of Surface Mounted LED Panel Lights1 No. Slim Integral SMD 2x2 Backlit LED Panel Light, IP20, 36W surface mounted fixture suitable for (ISO Class 5-8), system efficacy >100lm/W, minimum 3600lm output, 0°C-45°C ambient, 50Hz operation. Compact CRCA housing (depth <40mm) in white RAL9016 with translucent HET diffuser, burr-free, non-particulating materials. LM-80 compliant LEDs (Nichia/Cree/Bridgelux/Lumiled/Osram/Seoul), IEC 62471 compliant, CCT 5700K, CRI ≥80, L70 50,000hrs. Isolated CC driver (150-270V, 4kV surge, PF ≥0.95, THD ≤10%). NABL-approved manufacturer with LM-79/LM-80 reports from NABL/UL lab & ISO 14644 clean room compliance. Conforms to IS 10322 Pt.5/Sect.5:2017; IS 16105:2012; IS 16106:2012; IS 15885 Pt.2/Sec13:2012; IS 16108:2012. |
| 170 | Supply, Installation, Testing & Commissioning of 20W Recess Mounted LED Round Downlighter1 No. 20W high efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmissivity PS diffuser for soft light. CRI>80, IP40 housing, IP20 driver, ambient temp 0-45°C, CCT 4000/5700K, 50,000 hrs @ L70 life. Driver efficiency >85%, THD<10%, PF>0.95, surge protection 2.5kV, multistage isolated CC-CV driver (100-265V AC, SELV <60V DC per IEC). Luminaire lumen ≥2000 lm (>100 lm/W). Cutout dia ø170mm. Complete with supply, recess mounting, wiring termination, testing & commissioning |
| 171 | Supply, installation, testing, and commissioning of bottom openable, recess-mounted stainless steel cleanroom LED luminaire (1 ft x 1 ft size) suitable for ISO Class 3-5 (equivalent to FS209E Class 100-10000), with system efficacy ≥100 lm/W and minimum luminous flux of 1800 lumens. Luminaire dimensions shall be Compatible for existing cut out size, approximate weight ≤4 kg, featuring upgradable LED engine in polyester powder-coated CRCA or equivalent corrosion-resistant housing with high-efficiency translucent PMMA/polycarbonate diffuser, fully sealed with non-hygroscopic XLPE/silicone/EPDM gasket achieving IP65 rating post-installation, chamfered bottom edges for easy maintenance, designed for metallic walkable ceilings (50-80mm thick) via 300mm x 300mm cutout (1 ft x 1 ft compatible), flush top cover, frame load-bearing capacity ≥125 kg, loop-in-loop-out terminals, auto cut-off safety feature.LEDs sh all be LM-80 compliant from established manufacturers (e.g., Nichia, Cree, Bridgelux, Lumileds, Osram, Seoul or equivalent), with EN 62471 photobiological safety compliance (submit manufacturer certificate), CCT 5000-6500K, CRI ≥80, and L70 lifespan ≥50,000 hours at maximum drive current (submit full LM-80 report for ≥10,000 hours testing)Integrated isolated constant current LED driver shall support 150-280V AC, Constant Current - Constant Voltage LED Driver with APFC Construction, high voltage cutoff & auto restart @320V, phase to phase 440V protection upto 8hrs, Safety Extra Low Voltage Safe level<60V DC as per IEC standard, Electrical Safety with Class 1 Insulation, 50Hz input, with efficiency >85%, ≥3kV surge protection, power factor >0.95, THD <10%, and protections for short-circuit, open-circuit, and thermal faults.Compliance requirements include LM-79 (photometry/efficiency) and LM-80 reports from NABL/UL/ILAC accredited lab; manufacturer in-house testing lab accredited by NABL or equivalent Indian government body; standards IS 10322 Part 5/Sect 5, IS 16102/16105/16106/16108, IS 15885 Part 2/Sec 13, IEC 60598, RoHS; and post-installation lux verification. |
| 172 | Supply, installation, testing and commissioning of Integral, SMD LED, IP 65, 150 W LED Surface/Suspend Mounted Round Mid-Bay / High-Bay fixture with System efficacy of more than ≥135 lm/W (≥20250 lumens). Luminaire shall be made up of Die Cast Aluminium Housing. Luminaire shall have PC lens with polycarbonate reflector for Uniform illumination and wider light distribution. The innovative design with Aeroflo Technology ensures flow of free air through the Housing and keep the heat away from Electrical Components. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70B50 life of 100000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be CRCA constructed, Isolated type, multistage Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 4 KV internal surge protection, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail