Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of reinforced cement concrete in ground floors and paving n.exc 15cm thickness(below or above ground level) complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed by Engineer-in-Charge. |
| 3 | M & L for brick work with fly ash, old size bricks, straight or curved on plan exc 6 m mean radius , built in C M in 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 4 | All as per item No 3 here-in-before but using old serviceable bricks retreived from item No 2 hereinbefore. |
| 5 | M&L for reinforced cement concrete type B1 1:2:4 (20 mm graged aggregate) as in Slab supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and setting in mortar complete with joints to match complete all as specified and as directed by Engineer-in-Charge. |
| 6 | M&L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L for Use and waste of form work in finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L for rendering 10mm thick in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M&L for rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement & with using integral water proofing compound complete all as specified and as directed by Engineer-in-Charge. (Note : WPC shall be measured and paid for separately) |
| 11 | M&L for rendering 5mm thick in cement mortar in 1:3 on ceiling complete all as specified and as directed by Engineer-in-Charge. |
| 12 | M&L for Rehbilitaiton of existing detoriated RCC roof.(a) Taking down exsiting plaster, surface should be free from any loose paint, dust or grease.(b) Applying ust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivalent make in Fosroc / Thermax as approved by GE, with density : 1.01 Kg/ltr at 30°C and consumption : 0.2 kg/Sqm/coat complete all as specified.(c) Applying applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer’s specification including prepartaion of surface thoroughly and cleaning complete where ever required with using Product : Sikadur®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with consumption : 0.4 kg/Sqm and Product requirements : Comp with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified(d) Providing by mixing and trowel application of prepacked, light weight, structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent as approved by GE at an average thickness exceeding 10mm andupto 25mm to the prepared concrete substrate.Make : DrFixit/ Fosroc/Sikka or equivilant out of makes specified in list of makes.Note : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge. |
| 13 | M&L for preparing old plastered ceiling/soffits of chajjas surfaces and applying one coat of white wash complete all as specified and as directed by Engineer-in-Charge. |
| 14 | M&L for preparing new plastered ceiling/soffits of chajjas surfaces and applying three coat of white wash complete all as specified and as directed by Engineer-in-Charge. |
| 15 | M&L for preparation of new plastered surfaces of walls and applying three coat of White wash complete all as specified and as directed by Engineer-in-Charge. |
| 16 | M&L for preparation of Old plastered surfaces of walls and applying two coats of white wash complete all as specified and as directed by Engineer-in-Charge. |
| 17 | M&L for preparation of newly plastered surfaces of wall applying two coat of 1st quality acrylic distemper (ready mixed) having low VOC content, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer over a coat of 1 mm putty complete to achieve desired smoothness and eveness complete all as specified and as directed by Engineer-in-Charge. |
| 18 | M&L for complete removal of complete removal of existing treatment from old plastered surfaces of wall, using mechanical grinding machine and washing of old surface with water of wall, preparation of surfaces including filling of cracks and applying wall applying two coat of 1st quality acrylic distemper (ready mixed) having low VOC content, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer over a coat of 1 mm putty complete to achieve desired smoothness and eveness complete all as specified and as directed by Engineer-in-Charge. |
| 19 | M&L for complete removal of exterior old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, washing, rubbing down, filling of cracks etc and applying two coat of 100% premium acrylic exterior emulsion paint having low VOC, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives and including priming coat of exterior primer complete over a layer of acrylic wall putty to achieve desired smoothness complete all as specified and as directed by Engineer-in-Charge. |
| 20 | M&L for preparation of newly plastered surface of walls & Material & Labour for applying applying two coat of 100% premium acrylic exterior emulsion paint having low VOC, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives and including priming coat of exterior primer complete over a layer of acrylic wall putty to achieve desired smoothness complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Demolition of tiles or stone slabs of any description or thickness in floors laid, bedded and pointed in mortar and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L for Green Marble 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 23 | M&L for Glazed ceramic tiles in vertical surface 300X600 X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match & rendering 10 mm thick in CM(1:4) complete all as specified and as directed by Engineer-in-Charge. |
| 24 | M&L for 8-9 mm thick vitrified ceramic tiles 595x 595 mm , double charge (as approved) coloured tiles (square / rectangular), polished, set and jointed in neat cement slurry and pointed with 3 mm epoxy resin grout to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) including demolition existing tiling with cement mortar bedding (but not backing) complete all as specified and as directed by Engineer-in-Charge. |
| 25 | M&L for 8-9 mm thick vitrified ceramic tiles 595 x 595 mm , double charge (as approved) coloured tiles (square / rectangular), polished, as on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed with 3 mm epoxy resin grout to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including demolition existing tiling with cement mortar bedding (but not backing) complete all as specified and as directed by Engineer-in-Charge. |
| 26 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5sqm each and removing from site complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5sqm but not exc 4 sqm each and removing from site complete all as specified and as directed by Engineer-in-Charge. |
| 28 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer, calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engineer-in-Charge. (Note : Size of rebate will be as per door's shutter thickness or as directed by Engineer in charge.) |
| 29 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer, calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engineer-in-Charge. (Note : Size of rebate will be as per door's shutter thickness or as directed by Engineer in charge.) |
| 30 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer, calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed by Engineer-in-Charge including supply and fixing of the following items in each Shutter/ Leaf:-(a) Stainless steel (304 Grade) finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked.(b) Stainless steel (304 Grade) finished square tower bold 200 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833.(c) Stainless steel (304 Grade) Finished Handles 200 mm-2 Nos per leaf. (d) Stainless steel (304 Grade) finished sliding bold 300 mm-1 No per leaf, 16 mm dia as per BIS clause (iii) of BIS 15834-2020. (e) Stainless steel (304 Grade) Finished Floor door stopper 140 mm -1 Nos per leaf. |
| 32 | S & F Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats including supply and fixing of following items in each Shutter/ Leaf :-(a) Stainless steel (304 Grade) finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked.(b) Stainless steel (304 Grade) finished square tower bold 200 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833.(c) Stainless steel (304 Grade) Finished Handles 200 mm-2 Nos per leaf. (d) Stainless steel (304 Grade) finished sliding bold 300 mm-1 No per leaf, 16 mm dia as per BIS clause (iii) of BIS 15834-2020. (e) Stainless steel (304 Grade) Finished Floor door stopper-1 140mm Nos per leaf.(f) Stainless steel (304 Grade) wire cloth fixing as per manufacturer's instructions |
| 33 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge Including supply and fixing of the following items in each Shutter/ Leaf:-(a) Stainless steel (304 Grade) finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked.(b) Stainless steel (304 Grade) finished square tower bolt 150 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833.(c) Stainless steel (304 Grade) Finished Handles 100 mm-2 Nos per leaf |
| 34 | Taking down steel window/ ventilator of any description and of any type with or without guard bars complete all as specified and as directed by Engineer-in-Charge. |
| 35 | S&F powder coated Aluminium frame for doors, window with one or more rebates including joining cleat for fixing etc complete with powder coating on Aluminium minium thickness of powder coating 50 micron as per the specification the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawal plug and screw or with fixing clip or with expansion hold plate fasteners including making arrangements to fix guard bars and S&F of PVC sleeves for guard bars. Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required complete all as specified and as directed by Engineer-in-Charge. Note: Guard Bars shall be measured and paid for separetely. |
| 36 | S&F Powder coated Aluminium window (glazed and gauzed both),side hung type without sash bars, aluminum section weighing 0.55 Kg/m including necessary joining cleats, glazing, clips, rubber packing, anodised aluminium snap beading screws,aluminium fitting such as peg stays 150mm long (01 nos) for each shutter, hinges type B-21 100mm long (02 Nos) suitable handle (01 No) with powder coating of any colour (thickness of powder coating not less than 50micron) etc complete all as specified and as directed by Engineer-in-Charge. Note: Only Glass and wiremesh will be measured and paid seperately. |
| 37 | Taking down old unserviceable cooler stand of any size & any type fixed at cill level of windows at Ground & First Floor of building on external face of walls and making good the disturbed portion complete all as specified and as directed by Engineer-in-Charge. |
| 38 | S&F Framed work such as grills, gratings coolar stand, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-Charge. |
| 39 | M&L for providing and fixing stainless steel (Grade-304) railing made of hollow tubes,channels, plates etc including welding,grinding,buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts,decorative elements etc, of required size including making groove /drill with suitable fixing arrangement in RCC floor/staircase/brick wall complete all as specified and as directed by Engineer-in-Charge. |
| 40 | S&F sheet glass, ordinary quality 4.0 mm thick fixed with oil putty size of glass n.exc 0.50 sqm in each pane complete all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L for 5 mm thick figured glass pin head type and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-Charge. |
| 42 | S&F 300 mm ordinary rat tail type incl roller and roller plate complete fixed with screws to wooden frames or with welding to steel frames complete all as specified and as directed by Engineer-in-Charge. |
| 43 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-Charge. |
| 44 | S&F in repair Stainless Steel curtain rod decorative pattern with brackets stops complete all as specified and as directed by Engineer-in-Charge. |
| 45 | M&L for preparation of new steel & Iron surface of width or grith exceeding 10cm & applying two coats of synthetic enamel paint of 1st quality complete all as specified and as directed by Engineer-in-Charge. |
| 46 | M&L for preparation of new wooden surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of pink primer complete all as specified and as directed by Engineer-in-Charge. |
| 47 | M&L for preparation of old steel surfaces of any description not otherwise described over 10 CM width or girth and applying one coats of synthatic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 48 | S&F in repair vitreous china premium/1st quality wash down water closet wall hung (with dual hung cistern) EWC white/ivory/off white (closed pattern) including necessary accessories like rag bolts/ gel gasket etc including flushing cistern, CP jet spray complete all as specified Make Make:- Cat Part No. CASA \\"C022W Closet 680x365x780mm) & C022Y Cistern Set with Dual flush fittings of Parryware or HINDWARE QUED/JAQUAR equivalent in approved make list as specified and as directed by Engineer-In-Charge. |
| 49 | S&F in repair vitreous china counter wash basins, size 470x470mm white flat back to be fixed on granite/marble & RCC slab including cutting for and pinning in ends of brackets or erecting stand including 32mm waste fittings, waste pipe, chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge. Make: CERA SKU S2030115 or equivalant out of makes specified in list of makes. |
| 50 | S&F in repair vitreous china urinal 570x390x355 mm ,half stall type , white,waste coupling of PTMT including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement mortar, including connections to flushing pipe and outgoing pipes complete all as specified and as directed by Engineer-in-Charge. |
| 51 | S& F 32 mm Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/40mm-270 gms) complete all as specified and as directed by Engineer-in-Charge. |
| 52 | Taking up or down 15mm bore steel tubing and connections with fittings such as stop cock bib cock etc including cleaning for refixing or removal complete all as specified and as directed by Engineer-in-Charge. |
| 53 | Taking up or down 20 mm bore steel tubing and connections with fittings such as stop cock ‘bib cock etc including cleaning for refixing or removal complete all as specified and as directed by Engineer-in-Charge. |
| 54 | Supplying and laying of 20 mm (Outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Supplying and laying of 25 mm (Outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer-in-Charge. |
| 56 | S&F of 20 mm (OD) CPVC Brass Elbow fittings complete all as specified and as directed by Engineer-in-Charge. |
| 57 | S&F of 20 mm CPVC Brass Male Brass Threaded Adaptor (MTA/ MBTA) fittings complete all as specified and as directed by Engineer-in-Charge. |
| 58 | S&F in repair Rotational moulded polyethylene water storage tanks white colour in tripple layers (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I (1000 Ltrs Capacity) including Ball brass valves 20 mm bore, high pressure,with polythene float & flynut complete, including Dismantling old water tanks complete all as specified and as directed by Engineer-in-Charge. |
| 59 | S&F in repair Wall mixer with Single lever conceled diverter bath and shower 46mm (forged body) and spout complete all as specified and as directed by Engineer-in-Charge. (Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series) |
| 60 | S&F Brass CP Central hole Basin mixer 15mm bore for mixing hot & cold water screwed down for iron pipe complete all as specified and as directed by Engineer-in-Charge. Make Hindware Aspiro Center Hole Basin Mixer or equivalant in Parryware/Jaquar |
| 61 | S & F in repair 15 mm bore chromium plated Angular stop valve of cast copper alloy screwed down high pressure with on/off handle screwed both ends for iron pipe or for unions and fixed all as specified and directed .(Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series). |
| 62 | S&F in repair stop valve cast copper alloy concealed , screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 15 mm dia, ISI marked complete all as specified and as directed by Engineer-in-Charge. (Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series). |
| 63 | S&F in repair 15mm bore fancy type chromium plated, bib tap with crutch or butterfly handle screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed by Engineer-in-Charge. (Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series). |
| 64 | S&F in repair 20 mm dia CPVC ball valve fixed complete all as specified and as directed by Engineer-in-Charge. |
| 65 | S&F in repair 600mmx 450 m bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup complete all as specified and as directed by Engineer-in-Charge. washers |
| 66 | S&F 15mm bore, 450mm long PVC connection with PTMT nuts at each end complete all as specified and as directed by Engineer-in-Charge. |
| 67 | S&F grating doom CP 100mm dia of platedwith waste hole complete all as specified and as directed by Engineer-in-Charge. |
| 68 | S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed by Engineer-in-Charge. |
| 69 | S & F tubular towel rail brass chromium plated 20 mm dia and 60 cm long complete all as specified and as directed by Engineer-in-Charge. |
| 70 | S&F Stainless steel fancy type peg set of six and fixed in position with steel screws complete all as specified and as directed by Engineer-in-Charge. |
| 71 | Dismantling 100mm bore cast iron drain pipe, jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed by Engineer-in-Charge. |
| 72 | Dismantling 75 mm bore cast iron drain pipe, jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed by Engineer-in-Charge. |
| 73 | Taking down eaves gutters and rain water pipe (any size or any pattern) including all fittings, heads, shoes, bends, swan necks etc (measured over all as fixed along the central line over fittings and accessories) complete all as specified and as directed by Engineer-in-Charge. |
| 74 | Supply & fixing 110mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant including bends, socket , Y junction, Tee , cowl etc complete all as specified and as directed by Engineer-in- charge complete including low carbon hot roll gauge corrected oil pickled & drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and as directed by Engineer-in-Charge. (Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916). |
| 75 | Supply and fixing uPVC (SWR) bends any radius bore 110 mm provided with access door complete all as specified and as directed by Engineer-in-Charge. |
| 76 | Supply & fixing 75mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete including bends, socket , Y junction, Tee , cowl etc all as specified and as directed by Engineer-in- charge complete including low carbon hot roll gauge corrected oil pickled & drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and as directed by Engineer-in-Charge. (Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916) |
| 77 | Supply and fixing uPVC (SWR) bends any radius bore 75 mm provided with access door complete all as specified and as directed by Engineer-in-Charge. |
| 78 | Supply and fixing in repairs uPVC (SWR) junction single, (Single T) equal or unequal bore 75 mm provided with access door complete all as specified and as directed by Engineer-in-Charge. |
| 79 | Supply and fixing in repairs uPVC (SWR) junction single, (Single T) equal or unequal bore 110 mm provided with access door complete all as specified and as directed by Engineer-in-Charge. |
| 80 | Supply and fixing in repairs uPVC (SWR) reducers 110 mm to 75 mm complete all as specified and as directed by Engineer-in-Charge. |
| 81 | Supply and fixing in repairs uPVC (SWR) vent cowl bore 75 mm complete all as specified and as directed by Engineer-in-Charge. |
| 82 | S&F uPVC (SWR)75 mm floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-Charge. |
| 83 | Demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness(below or above ground level) complete all as specified and as directed by Engineer-in-Charge. |
| 84 | M&L for 50mm thick PCC 1:3:6 type B-1, using 20mm graded stone aggregate as in floors/plinth protection, laid in slope in 1:30 in pannels n. exc. 2m long, concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 85 | Dismantling Bricks tiles or terracing tiles, single layer on roofs complete all as specified and as directed by Engineer-in-Charge. |
| 86 | Removing Mud in roofs, any thickness,including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by Engineer-in-Charge. |
| 87 | Removal of exacavated soil in soft & loose soil to a distance exc 250 and n. exc. 500m m and depositing where as directed at a level of 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 88 | M&L for 40 mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) over roof complete all as specified and as directed by Engineer-in-Charge. |
| 89 | M&L for rendering 10mm thick in cement mortar in 1:4 on roof even and smooth with using Liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge. (Note : WPC shall be measured and paid for separately) |
| 90 | M&L for Roof Treatment in as specified below and as directed :(a) Cleaning, washing of surface and removing any debris, Surface should be free from any loose paint, dust or grease.(b) Applying one coat of Elastomeric PU Based liquid membrane diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm.(c) Laying polyster reinforced fiber net/150 gsm Geotextile mesh, upto 300 mm on walls.(d) Applying two coats of undiluted PU Based liquid membrane, having Elongation more than 400%, Tensile Strength more than 2 N/mm2 and alkali & fungal resistant maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls.(e) The complete treatment to be carried out by authorised applicator of waterproofing manufacturer.Make : Asian/Fosroc/ Dr Fixit etcNote : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge. (ii) The plan area of floor shall be considered for payment . |
| 91 | M&L for Water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :-(a) Demolition of cement concrete in sunken portion.(b) Preparation sunken surfaces by cleaning of and removal of loose concrete (c) Filling cracks with polymer modified mortar using Dr. Fixit Pidicrete URP or equivalent in Forsoc and other approved make (d) Applying 2 coats of Dr. Fixit Bath seal WPC in suken areas and laying a protective plaster in 10mm thickness in cement mortar (1:3) admixed with Dr. Fixit Pidicrete LW + @ 220ML per bag of cement (e) Applying mix of of DR FIXIT PIDICRETE URP in the ratio 1:1:5 on floor and vertical surface of sunken portion as per manufacturers instructions complete(f) Filling with P:C:C 1:5:10 Type-E2 using 40 mm graded brick aggregate complete all as specified and directed by Engineer-in-charge Note: The plan area of floor shall be considered for payment. |
| 92 | Supply only liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge. |
| 93 | Excavation in trenches n exc 1.5m wide and n exc1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 94 | Returning filling in trenches incl spreading, levelling, watering, & well ramming in layers not exc 25cm thick complete all as specified and directed, in soil complete all as specified and as directed by Engineer-in-Charge. |
| 95 | Demolition and breaking up 150mm bore drain pipe (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and as directed by Engineer-in-Charge. |
| 96 | S&F DWCPE (SN8) pipe 150 mm dia (inner) as per IS-16098 (Part-II) laid in trenches including all necessary accessories / fitting / jointing / rings, joiting and testing complete all as specified and as directed by Engineer-in-Charge. |
| 97 | Surface excavation averaging 15 cm deep and not exceeding 30 cm deep and getting out in soft and loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 98 | M&L for 75 mm thick cement concrete type D2, (1:4:8) using 40mm stone aggregate as in sub base complete all as specified and as directed by Engineer-in-Charge. |
| 99 | M&L for Spreading and levelling in layers n exc. 25 cm thick including watering and consolidation complete all as specified and as directed by Engineer-in-Charge. |
| 100 | M&L for Machine pressed Coloured (Red / Yellow) precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed by Engineer-in-Charge. |
| 101 | Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators, MCB, DB, earth plug, lamp, street light etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 102 | Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators, MCB, DB, earth plug, lamp, street light etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail