| 1 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for (unreinforced) complete complete all as directed. |
| 2 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed. |
| 3 | Dismantling of timber in scantling 40 sq cm and over in section in any position in unframed work complete all as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as directed. |
| 5 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as directed. |
| 6 | Dismantling of wall and ceiling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as directed.. |
| 7 | Taking down chowkats or frames not exc 1.5 Sqm and (without taking off shutter from the frames) and removal from site complete all as directed. |
| 8 | Taking down chowkats or frames exc 1.5 Sqm and n.exc 4 Sqm (without taking off shutter from the frames) and removal from site complete all as directed. |
| 9 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as directed. |
| 10 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as directed. |
| 11 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with bead complete all as directed. |
| 12 | Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal complete all as directed. |
| 13 | Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal complete all as directed. |
| 14 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil etc. complete all as specified and as directed. |
| 15 | Excavation over areas, n exc 1.5 m deep and getting out soft soil complete all as specified and as directed. |
| 16 | Excavating in trenches, n exc. 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc complete all as specified and directed. |
| 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. etc complete all as specified and directed. |
| 18 | Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed. |
| 19 | M&L for Hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface with Broken stone or boulders complete all as specified and as directed. |
| 20 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 21 | M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregates) as in surface channel / drains complete all as specified and directed. |
| 22 | Extra for forming fair finished drain or channel 30 cm inner girth cement concrete using extra cement including forms moulds mitred and stopped ends etc complete all as specified and directed. |
| 23 | M&L for PCC type C2 1:3:6 (using 40mm graded stone aggregates) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars complete all as specified and directed. |
| 24 | M&L for providing cement concrete (1:2:4) type B-0 (using 12.5 mm size graded aggregate) as in coping set incl weathering, slightly rounded or chamfered angles & thickness complete all as specified and directed. |
| 25 | M&L for Pre-cast cement concrete solid block type C1 1:3:6 (using 20mm graded stone aggregates) masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 26 | M&L for Pre-cast cement concrete hollow block type C1 1:3:6 (using 20mm graded stone aggregates) as per IS 383 masonry with hollow blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 27 | M&L for RCC (1:2:4) nominal mix type B1 (using 20mm graded stone aggregates) as in slabs supported on walls, beams and column in floors, roofs, landing, balconies, canopies, deck slabs, and in shelves and like etc complete all as specified and directed. |
| 28 | M&L for RCC M-25 Design mix (using 20mm greded crushed stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed. |
| 29 | M&L for RCC M-25 Design Mix (using 20mm graded stone aggregates) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed |
| 30 | M&L for RCC M-25 Design mix (using 20mm graded stone aggregates) as in Beams cantilevers, bressummers, Lintels over 1.5m span complete all as specified and directed. |
| 31 | M&L for Brickwork with fly ash old size brick , straight or curved on plan to any radius in half brick thick walls,built in CM 1:4 complete all as specified and directed |
| 32 | M&L for walling of RR stone masonry uncoursed, well bonded, bedded and solidly hearted built in CM 1: 6 incl brought upto course at interval of every 60cm complete all as specified and as directed. |
| 33 | Use and waste of Formwork to sides of concrete foundations, footings bases of columns below GL and similar work, flat rough finished surfaces of concrete complete all as specified and directed. |
| 34 | Use and waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter flat rough finished surfaces of concrete complete all as specified and as directed. |
| 35 | Use & waste formwork to fair finished surface to soffits of suspended slabs such as roof slabs, floor slabs, landings, and similar work not exceeding 200mm thick etc complete all as specified and directed. |
| 36 | Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat rough finished surface of concrete complete all as specified and as directed. |
| 37 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 38 | M&L for 2nd class hard wood in scantlings timber framed and fixing in wrought etc. complete all as specified and as directed. |
| 39 | M&L for 2nd class hard wood in scantlings timber framed and fixed wrought in repairs, to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions etc complete all as specified and as directed. |
| 40 | M&L for 2nd class hard wood for Plain fillets square, rectangular or triangular in section n. Exc 6sqcm wrought, secured with nails or brads complete all as specified and as directed. |
| 41 | S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.. |
| 42 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 43 | S&F 30mm thick Second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats but divided into squares, with plain, chamfered or rounded, mitred andrebated sash bars, any numbers etc all as specified |
| 44 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.. |
| 45 | S&F actory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing, complete all as specified and directed. |
| 46 | S&F Mild steel butt hinges 100 mm long, medium weight, cold rolled complete all as specified and directed. |
| 47 | S&F Mild steel butt hinges 75 mm long, medium weight, cold rolled complete all as specified and directed. |
| 48 | S&F Aluminium anodised barrel tower bolts, 100 mm long, of extruded section. complete all as specified and directed. |
| 49 | S&F Aluminium anodised barrel tower bolts, 150 mm long, of extruded section. complete all as specified and directed. |
| 50 | S&F Extruded aluminium alloy handles 125mm long, fabricated type, anodised. complete all as specified and directed. |
| 51 | S&F Extruded aluminium alloy handles 150mm long, fabricated type, anodised. complete all as specified and directed. |
| 52 | S&F 250 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed. |
| 53 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 54 | S&F aluminium anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and as directed.Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd. |
| 55 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 56 | M&L for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 57 | M&L for TMT bars 6 to 8 mm dia , as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 58 | M&L for TMT bars 6 to 10 mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 59 | S&F rolled mild steel section sections any type as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, FE -290 Gde E-165, complete all as specified and as directed. |
| 60 | S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. steel conforming to Fe 410-W (Gde-E-250) quality A complete all as specified and directed. |
| 61 | S&F steel windows Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc all as specified and as directed. |
| 62 | S&F steel windows Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded etc all as specified and as directed. |
| 63 | S&F 0.50mm thick pre - painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and directed. |
| 64 | S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in ridges, valley, eaves, etc and fixed with self tapping screws complete all as specified and directed. |
| 65 | S&F 6 mm thick plywood, grade BWR, type BB, 5 ply fixed in wall, flat or sloping with screws to timber frame work complete all as specified and directed. |
| 66 | M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregates) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed. |
| 67 | M&L for 75mm PCC (1:4:8) type D-2 (using 40mm graded stone aggregares) as in sub base of floor etc complete all as specified and directed. |
| 68 | M&L for 25 mm thick PCC (1:2:4) type B-1 (using 20 mm graded stone aggregates) as in flooring etc complete all as specified and directed. |
| 69 | M&L for 20mm thick granite slabs of any type (table rubbed and polished) on cooking platforms and like, set and jointed in net cement slurry and pointed in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including necessary moulding at edges laid over and including 20mm thick cement mortor screed bed in cement mortor (1:6) complete all as specified and directed. |
| 70 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed. |
| 71 | M&L for coloured (450x350/350x250)x7-8 mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick rendering as backing coat in cement mortar (1:4) complete all as specified and directed. |
| 72 | M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc, over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed. |
| 73 | M&L for rendering 15mm thick in cement morter (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 74 | M&L for rendering 20 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10mm thick each layer) in cement mortar in (1:4) using water proofing compound in top layer and finished even and smooth (without using extra lime or cement) complete all as specified and directed.Note: Water Proofing Compound measured and paid separately. |
| 75 | Supply only liquid Water Proofing Compound of approved make complete all as specified and directed. |
| 76 | M&L for raking out joints/ pointing to random rubble masonary coursed or uncoursed work in walls on edge in floors, surface channels, roofs, etc complete all as specified and directed. |
| 77 | M&L for raised pointing in CM 1:4 to block in course or squared rubble coursed or uncoursed masonry or concrete block walling etc complete all as specified and directed. |
| 78 | M&L for preparing newly plastered surfaces of walls etc. and applying three coats of white wash complete all as specified and directed . |
| 79 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper of approved colour with roller over one coat of primer complete all as specified and directed. |
| 80 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement paint over a coat of suitable primer complete all as specified and directed. |
| 81 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exceeding 0.50sqm in each pane complete all as specified and directed. |
| 82 | M&L for preparation of new or previously untreated wooden surfaces of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 83 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 84 | M&L for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 85 | S&F 15 mm bore medium grade galvanized steel water tubing with all fittings, fixed to wall/ceiling or laid in floor complete all as specified and directed. |
| 86 | S&F 20 mm bore medium grade galvanized steel water tubing with all fittings, fixed to wall/ceiling or laid in floor complete all as specified and directed. |
| 87 | S&F 40 mm bore pipe galvanized iron medium grade complete with all fittings fixing on wall, jointed tested and commissioned complete all as specified and directed. |
| 88 | M&L for cutting existing steel tubing for alteration (Each cut measured) including Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to ffrom connector) done in position without taking down |
| 89 | Supply and laying of CPVC pipes SDR11 & Plain CPVC SDR 11 fitting on wall /ceiling or laying in floors etc of outer dia 16 mm dia complete all as specified and directed |
| 90 | Supply and fix brass tee of outer dia 16mm dia complete all as specified and directed |
| 91 | S&F 15mm bib taps, CP, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed etc complete all as specified and directed. |
| 92 | S&F in repairs 15mm bib taps, CP, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed etc complete all as specified and directed. |
| 93 | S& F in repair 15mm Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed etc complete all as specified and directed. |
| 94 | S&F in repair Brass CP mixer for mixing hot & cold water screwed down for wash basin pipe and fixed |
| 95 | S&F Brass CP basin mixer for mixing hot & cold water screwed down for iron pipe and fixed with 15mm dia iron pipe complete all as specified and directed. |
| 96 | S&F stop valves, cast copper alloy , screwed down , high pressure , with crutch or butterfly handle, screwed both ends for iron or for unions and fixed to size 15mm complete all as specified and directed |
| 97 | S&F in repair stop valves/ angular valves fancy type 15 mm bore cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for pipe or for unions and fixed complete all as specified and directed. |
| 98 | S&F for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 99 | S&F for Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 100 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by the Engr-in-Charge. |
| 101 | S/F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 102 | S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches/fixed to walls complete all as specified and directed. |
| 103 | S&F 75 mm dia PVC (SWR) bends of any radius fixed to PVC Pipe complete all as specified and directed. |
| 104 | S&F 110 mm dia PVC (SWR) single Tee of any radius fixed to PVC Pipe complete all as specified and directed. |
| 105 | S&F 110 mm PVC (SWR) P or S trap complete all as specified and directed by the Engr-in-Charge. |
| 106 | S&F Cast iron Nahani trap 100 mm outet dia, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as specified and directed. |
| 107 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) as in bed to drain pipes 100 mm bore, including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 108 | S&F Soap dish, vitreous China white, approximate size 160x 160x90mm. any type, fixed to wall plugs with chromium plated brass screw complete all as specified and directed. |
| 109 | S&F Vitereous china squatting pan 'Orissa pattern' size 580 x 440mm white with integral foot rest excluding flushing cistern and flush pipe fixed with 110 mm PVC (SWR) 'P' trap complete all as specified and as directed. |
| 110 | S&F for PVC low level flushing cistern of 10 ltrs capacity action type white body with intel ball valve float handle bracket flush pipe etc complete and connecting to WC with PVC flushing pipe complete all as specified and directed. |
| 111 | S&F for vitreous china, white colour, flat back, wash hand basin of approved make and of size 55 x 40 x 79cm fixed with brackets , including providing 32 mm dia PVC waste pipe , 32 mm bore CP waste coupling and making all necessary connections complete all as specified and directed. |
| 112 | S&F in repairs for vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete all as specified and directed. |
| 113 | S&F for 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 114 | S&F in repairs aluminium power coated fancy curtain rails plain or colour 20 to 25 mm dia as approved with teak wood finishing brackets and knobs complete all as specified and directed. |
| 115 | E/M WorksTaking down carefully copper / aluminium point wiring(light,fan,socket or power) complete along with fittings such as switches ,Sockets, ceiling rose , lamp holder ,tube light fittings and making good distrubed surfaces on walls etc. omplete all as directed. |
| 116 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size passing through and including suitable PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc , including cutting chases, making good with cement mortar 1:3, terminated in and including providing modular metal flush box of suitable size for fixing of modular switches, sockets, fan regulators etc for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed. |
| 117 | All as per Item No.116 here in above but for One 2/3 pin socket outlet 5/6Amps on independent board |
| 118 | All as per item No 116 above but, one socket outlet, three pin, 5/6 Amp on the same board with other switches |
| 119 | All as per Item No.116 here in above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm Please Enable Macros to View BoQ information |
| 120 | All as per Item No.116 here in above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm Please Enable Macros to View BoQ information |