| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engg-in-Charge. |
| 2 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engg-in-Charge. |
| 3 | M&L for pre-painted galvalume aluminum Zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridges etc fixed with self drilling screws complete all as specified and directed by Engg-in-Charge. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engg-in-Charge. |
| 5 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) (Fe-410-W(Gde-E-250) quality-B) including distance pieces, cleats etc including steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication, etc complete all as specified and directed by Engg-in-Charge. |
| 6 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engg-in-Charge. |
| 7 | S&F rolled mild steel Fe 410-W (Gde-E-250) quality-B in framed work as in doors or gates of angle and grills of drains or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication, etc complete all as specified and directed by Engg-in-Charge. |
| 8 | Demolition of brickwork or stone/ boulder masonry / PCC block masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engg-in-Charge. |
| 9 | M&L for pre-cast cement concrete block masonry type C-1,1:3:6 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and directed by Engg-in-Charge. |
| 10 | Taking down cement plaster on brick wall, ceilings etc, racking out joints, hacking for key & scrubbing with water complete all as specified and directed by Engg-in-Charge. |
| 11 | M&L rendering 15mm thick in cement plaster in CM 1:6 on fair faces of brick or concrete, external surfaces of walls finished the surface fair and even without using extra cement complete all as specified and as directed by Engg-in-Charge. |
| 12 | M&L rendering 10mm thick in CM 1:4 on fair faces of brick or concrete, internal surfaces of walls finished the surface fair and even without using extra cement complete all as specified and directed by Engg-in-Charge. |
| 13 | M & L for PCC (1:2:4) Type B1 (using 20 mm graded stone aggregate ) in coping, including necessary form work finished fair and even surface without using extra cement including weathering slightly rounded or chamfered angles and throating complete all as specified and directed by Engg-in-Charge. |
| 14 | M&L for preparation of newly plastered or un plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer incl a coat of cement based wall care putty complete all as specified and directed by Engg-in-Charge. |
| 15 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces (exterior weather coat) paint in normal/camouflage pattern as directed by Engr-in-Charge of any tint as approved over one coat of primer complete all as specified and directed by Engg-in-Charge.Note: contractor are advised to quote the rate considering the work will be executed up to the height of 10 m. |
| 16 | M&L for applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces (exterior weather coat) paint in normal/camouflage pattern as directed by Engr-in-Charge of any tint as approved over one coat of primer complete all as specified and directed by Engg-in-Charge.Note: contractor are advised to quote the rate considering the work will be executed up to the height of 10 m. |
| 17 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer |
| 18 | M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete allas specified and as directed by Engr-in-Charge. |
| 19 | M&L for approved earth filling by spreading leveling to make the required level etc. in back of Traverse Wall along Danger buildings upto 10m height from GL complete all as specified and as directed by Engineer-in-Charge. Note- (i) Soil required for filling shall be brought out from out side MD Land under his own arrangement of contractor (ii) Soil shall be free from pebbles, stones, bushes, shrubs, other vegetation, black cotton soil and shall have non-silting and non-swelling properties complete (iii) Measurement for filling in back of traverse wall shall be carried out by stack measurement of the soil brought by the contractor (iv) Measurement shall be carried out for net finished volume of earth filled subjected to 20% deduction due to bulkage. |
| 20 | S&F in repair for purpose made MS framed work as in weep hole cover of flat Iron frame with welded mesh and coated with enamel paint (Min wieght should not be less than 250 gms each) complete all as specified and directed by Engr in Charge. |
| 21 | M&L for repairing the edge / corner of Chajja / roof projection and similar work by removing plaster width / girth not exc 150mm and making good with 10mm thick rendering in cement mortar 1:3 to match with existing surface complete all as specified and directed by Engg-in-Charge. |
| 22 | Removal of existing roof treatment consisting of screed bed, tar felts of any description etc, and removal of debris out side MD land complete all as specified and directed by Engg-in-Charge. |
| 23 | M&L for screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 including mixing only liquid water proofing compound as per manufacturers' instructions and finishing the surface fair and even complete all as specified and directed by Engg-in-Charge.Note:- WPC will be measured & Paid separately |
| 24 | Supply only liquid water proofing compound |
| 25 | Material and labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified complete all as specified and as directed by Engg-in-Charge. |
| 26 | M&L for PCC in roof pading filling and mass concrete type B1, 1:2:4 (using 12.5 mm garded stone aggregate) complete all as specified and directed by Engneer- in -charge |
| 27 | Demolition of concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of debris to out of MoD land complete all as specified and directed by Engg-in-Charge. |
| 28 | M&L for cement concrete type B- 1, 1:2:4 (20mm graded aggregate) as in road / hardstanding of thickness 150 mm including steel formwork and finishing the surface using floater etc complete all as directed by Engineer-in-Charge |
| 29 | M&L demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar complete all as directed by Engineer-in-Charge. |
| 30 | M&L for 75 mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc complete all as specified and directed by Engg-in-Charge. |
| 31 | M&L for sand cushioning 25mm thick over concrete surfaces, spread complete all as specified and directed by Engg-in-Charge. |
| 32 | M&L for machine pressed precast concrete interlocking paver block of approved shape and size of 60mm thickness, with minimum compressive strength of 35N/sqm (M-35), without correction factor for chamfering, made in rubber moulds with 0.50mm thick scratch proof lacquer coating on top surface, with grey cement and pigment laidcomplete all as specified and directed by Engg-in-Charge. |
| 33 | Demolition of existing concertina coil of any dia and barbed wire from top of the Boundary wall complete.(Note : Length will be measured as length of Boundary wall to be demolished) complete all as specified and directed by Engg-in-Charge. |
| 34 | S&F mild steel galvanised concertina coil punched type of loop dia 1060 mm when up streched tying at five places with galvanised iron clip and pitch between the barbs 24.5mm etc as approved by Engr -In-Charge.Note:- The punched type concertina coil shall be streched to maintain the dia of up streched coil as 1060 mm and number of circle as 52 per coil and shall cover at RM per coil. |
| 35 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (Note :- each line wire to be measured) complete all as specified and directed by Engg-in-Charge. |
| 36 | S&F of blind curtain for window consisting of horizontal fiber/ plastic strip( Each strip cover whole length of window and having not less than 25mm each one connected to handle and pully system and by pulling handle all horizontal member turns in horizontal position for see through view from glass window and by pulling handle from different sides, all horizontal members moves in upward side and get collected simillarly all members moves in downward side and cover the whole window for blind the view complete all as specified and directed by Engg-in-Charge. Please Enable Macros to View BoQ information |