| 1 | Demolition of textile covering and including all padding concrete over RCC slab over roof, including removal of waste material away from Dockyard premises complete all as specified and directed. |
| 2 | M&L for providing, cement concrete Type B1 1:2:4 (Using 20mm graded stone aggregate) as in roof padding concrete and kerbs or mud stops, rounded or chamfered on edges (40mm thickness) complete all as specified and directed. |
| 3 | M&L for 10mm thick scred bed over padding concrete cement mortar 1:4 with water proofing compound as per manufacture instructions by weight of cement and finish the surface even and smooth with out using extra cement complete all as specified and directed.Note :- Supply only WPC will be measured and paid separately. |
| 4 | M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per Sqm including cleaning of surfaces complete all as specified and directed. |
| 5 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) shall be laid over entire roof surface and on vertical surface up to groves with other laps of 100mm. The over lap shall be sealed by flames complete all as specified and directed. |
| 6 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing)and rubbish off the removal of debris outside of dockyard premises all as directed. |
| 7 | M&L for coloured non skid ceramic tiles 7mm to 8mm thick (square or rectangular) of area exc 0.18 but n.exc 0.38 Sq.m in floor set and jointed in neat cement slurry and pointed in coloured cement to match laid over 15mm screed bed in cement mortar 1:6 complete all as specified and directed. |
| 8 | M & L for coloured glazed ceramic tiles 350 x 250 x 7 mm /450X300X7/8 mm thick in dado set and jointed in neat cement slurry and pointed in coloured cement to match fixed over incl rendering in CM 1:4, 10mm thick all as specified and directed. |
| 9 | Dismantling of wall and ceiling boards/ wall partition (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets / aluminium frame work complete all as specified and directed. |
| 10 | S&F Anodised Aluminium Frame Work (snap grid) for false ceiling work made from anodised aluminium main /cross tee of size not less than 38 mm x 24 mm x 1.5 mm thick and 28 mm x 24 mm x 1.5 mm thick respectively for false ceiling of grid size 600 mm x 600 mm including necessary hanging arrangement comprising of 6 mm dia MS rod, 'J' bolts with necessary bolts, nuts and washer all as per manufacturer's instruction. The snap grid (main & cross section) shall be supported at ends all along the wall with Anodised Aluminium angle of size 40mmx25mmx2mm, weighing 0.36 Kg / RM. The main and cross tees shall be jointed at junction / crossings with anodized aluminium angle bracket of size 15mmxl5mmx1.5mm, weighing 0.12 Kg per running metre, fixed with suitable size mild steel, bolts nuts and washers complete as per manufacturer's instruction and as specified and directed. |
| 11 | Demoliton brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc and removing the debries to a distance 5km away from the Dockyard premises all as specified and directed. |
| 12 | M&L for Pre cast cement concrete type 1:3:6 type C-1 (20mm graded stone aggregate) block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed. |
| 13 | Taking down Chowkats or frames n exceeding 1.5 Sqm each (Without taking off shutters from the frame) and removing away from site complete all as specified and directed. |
| 14 | Taking down Chowkats or frames exceeding 1.5 Sqm but n exc 4.00 Sqm each (Without taking off shutters from the frame) and removing away from site complete all as specified and directed. |
| 15 | S&F factory made UPVC white colour sliding window three track of area not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67 mm). Sliding mesh Sash (42mm x 57mm) sliding interlock (one vertical lenght in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 + - 0.2mm thick galvanised steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware (Touch Lock of zinc alloyed (white powder coated ), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: the unit rate quoted by the contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose. |
| 16 | S&F aluminium powder coated door shutter with chowkats made out of hollow aluminium sections as mentioned below, each shutter having 2 Nos ‘D’ type aluminium handles of 200mm long 2 Nos aluminium tower bolts of 200mm long and 1 No mortice lock of 6 lever with key in duplicate, shutter partly glazed with 5mm thick sheet glass and partly paneled with 12mm thick particle board pre-laminated fixed with glazing clips, rubber beadings and aluminium beadings all complete. Chowkat size : 101.60 x 44.45 x 2.40 mm (1.608 Kg/RM appx)Shutter Top rail : 114.30 x 2.15 mm thick (1.836 Kg/RM appx) Bottom rail : 150.00 x 2.20mm thick (2.376 Kg/RM appx) Middle rail : 83.50 x 1.70 mm thick (1.243 Kg/RM appx) Vertical rail : 85.00 x 1.80 mm thick (1.302 Kg/RM appx) |
| 17 | S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supporting and fixing in opening as per specification and drawing complete all complete all as specified and directed. |
| 18 | S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out MS tubes for top and bottom rails MS shall be cuvred with heat moulded plain colour PVC `C` channel having PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame / sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame at site as per specification complete. |
| 19 | S&F anodised aluminium DG-102 (anodised transperent or dyed to require shade according to IS 1868 with minimum anodic coaing of grade AC -15) of approved design / pattern , with approved standered scetion and fixed to the existing window frame with CP brass /stainless steel screw @200 mm ceneter to center ,WT 225gm/square feet including cutting the gril to propre opening size for fixig and operation of hanmdles and fixing approvedanodised aluminum stanedre scetion around the openings , all comete as per requirement and direction of Engr-in- Charge. |
| 20 | S&F 100mm stainless steel butt hinges fixed with SS screws all complete all as specified and directed. |
| 21 | S&F 150mm aluminium anodized barrel tower bolt of extruded section all complete all as specified and directed. |
| 22 | S&F 125mm aluminium anodized handles, cast type all complete all as specified and directed. |
| 23 | S&F in repairs door closer hydraulically ( aluminium extruded section body) regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 24 | S&F in repairs floor door stopper 140 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring all as specified and complete all as specified and directed. |
| 25 | S&F in repairs 5 mm thick glass of ordinary quality fixed with aluminium beads in squares not exc 0.5 Sqm in each pane complete all as specified and directed. |
| 26 | Taking down cement plaster on brick or concrete wall etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 27 | M&L for 10 mm thick rendering in cement mortar (1:6) on brick or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L for rendering 15 mm thick plaster in CM (1:4) using SBR latex emulsion @ 4% by weight of cement on brick or concrete surfaces of walls the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 29 | M&L for 5 mm thick plastering in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces fair and even without using extra cement all as specified and directed. |
| 30 | Supply only integral water proofing compound all as specified and directed. |
| 31 | M&L for preparing newly plastered and unplastered surfaces of ceiling and applying three coats of white washing complete all as specified and directed. |
| 32 | M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a one coat of alkali resistant primer with 1mm thick wall care putty over plastered surface to prepare surface even and smooth complete all as specified and directed. |
| 33 | M&L for preparation of newly plastered surfaces of walls and applying two or more coats of 100% premium acrylic paint having VOC less than 50 gm/litre and UV resistance a per IS 15489:2004, Alkali & fungal resistance, dirt resistance ecterior paint of required shade 9company depot tinted with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior promer applied @ 0.9 litre/10 sqm over new surfaces complete all as specified and directed. |
| 34 | Complete removal of existing treatment of old decorated surfaces of wall and applying three coats of white wash complete all as specified and directed. |
| 35 | Complete removal of existing treatment of old decorated surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer over two coats of cement based white wall putty of minimum thick ness 1.5 mm (in two coats) and cutting to smooth surfaces by sand paper complete all as specified & directed. |
| 36 | Complete removal of existing treatment on walls and for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces with one coat of birla putty complete all as specified and directed. |
| 37 | M&L for complete removal of existing treatment on ceiling and applying two coat of distemper oil emulsion over one coat of primer over 3mm thick wall care putty on ceiling complete all as specified and directed. |
| 38 | Chipping and removing of spalled concrete,craked,porous/Micro concrete above 25mmto 100mm: Chipping and removing of spalled concrete, craked, porous/Micro concrete andweekconcrete ,at allheigths and depths,upto a depth of 25mm behind thereinforcement rods or depth of cabonation whichever is deeper andcleaning of the reinforcement barsand exposed concrete to remove scale by chipping,wire brushing ,emery sheets etc to enable the mesurement of the reduced dia of the bars, application of zinc primer to the bars on all sides of the reinforcement and application opfepoxy bonding agent to exposedold concrete surfaces. Leaddistanceshall be 50m from ground level to unloading location. This also includes the chipping and removal of gunning work carried out recently to check the reinforcement in order to decide on the requirement and addition of reinforcement . Payment towards application of zinc primer and epoxy bonding agent shall be paid in respective items rate of the contract. Scope including menpower, machinery, tools and consumables etc , to complete the job as per direction of Engr-in - Charge Note : Superfical area of the concrete is measured. |
| 39 | Bond coat: Applying zinc primer to the bars on all sides of the reinforcement and application of fepoxy bonding agent to of acrylic emulsion bonding agent (or) Epoxy bonding agent. This application shall be carried out for concrete structural bonding agent between old concrete surface to new concreteing complete all as specified and directed. Note : Superfical area of the concrete is measured |
| 40 | Polymer Modified concrete: Providing and applying polymer modified cement concrte (1:1:2) in specfied ratio by using 15% polymer and 53 grade cement to RCC surfaces in case the damaged thickness of RCC exceeds 30mm, the thickness assumed max upto 100mm. etc incl certain formwork as per site condition complete as instructed and directed by Client/ Consultant |
| 41 | Anti Caronation coating at out side of the concrete surface: Acrylic based plasto-elastic, crack - bridging protective coating system. Over the entire concrete surface including materials, machinery, labour tools etc all complete all as specified and directed.Note : Superfical area of the concrete is measured. |
| 42 | Grouting: A shrinkage free low viscos epoxy resin based injection of epoxy resin (wet and submerged cracks) apply of nozzles to be fixed shrinkage free moisture insentive epoxy resin free flow grout complete all as specified and directed.Note : Superfical area of the concrete is measured. |
| 43 | M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed. |
| 44 | M&L for providing Shear connectors and Anchoring by drilling 16 mm dia holes up to depth of 100mm in concrete surfaces and fixing 10 mm dia TMT bars L shaped anchor rods as shear connectors by using Fosroc Lokfix chemical or any other equilent make as approved by GE (Mix of base and hardener of the polyester resin) in defective concrete area of the slab / column / beams / chajjas / lintel etc or any other structural member as per site requirement after cleaning the drilled hole by using water jet and after drying clean the surface with blower to remove all loose fine particles present in the hole. The Mix of base and hardener of the polyester resin shall be prepared by thorough mixing of base & hardener by the help of spatula. After preparing the mix the holes shall be filled to a minimum depth of 1/3rd of the hole with the prepared polyester resin and the reinforced bar shall be inserted to full depth of hole and extra length of the reinforcement bar shall be bent into the concrete to maintain proper cover to the reinforcement complete all as specified and directed. |
| 45 | Drilling and fixing of copper nozzels in RC members : Drilling 10mm dia upto 300mm deep holes in structural members horizentally and vertically in stagged manner at the intervals as per specfications and drawings. Clean the holes by hair blower prior to fixing nozzels and insert 8mm dia. copper nozzels in holes for repair work and strengthening work of existing structure, materials machinery and menpower inclung etc, completed as per the direction of Engr-in-Charge. Injection of chemical grout will be paid separate line item. Note : Superfical area of the concrete is measured. |
| 46 | Ceiling of Cracks : Supply and apply a solvent -free, moisture tolerant, thixotropic, structural two-part adhisive. Mortar and concrete must be older than 28 days (depends on minimal requirement of strengths). Verify the substarte strength (concrete, masonary, natural stone). The substrate surface (all types) must be clean, dry and free from contaminants such as dirt,iol,grease, existing surface treatment and coatings etc. Steel substracts shall be removed. When using a thin layer adhesive, apply the mixed adhesive to the prepared surface with a spatula, trowel, notched towel, (or with hands protected with gloves). When applying as a repair mortar use form work. When using for bonding metal profiles onto vertical surfaces, support and press uniformly using props fro at least 12 hours, depending on the thickness applied (not more than 5mm) and the room temperature. Once hardened check the adhesion will be checked by tapping with a hammer. |
| 47 | S&F 160 mm dia PVC (SWR) pipes single, socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 48 | Taking down GI tubing 15mm dia with all connection all as specified and directed. |
| 49 | Taking down GI tubing 20mm dia with all connection all as specified and directed. |
| 50 | S&F 15mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. |
| 51 | S&F 20mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. |
| 52 | Cutting chases, pinning in stone, concrete block or slab wall, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth in brick walls complete all as specified and directed. |
| 53 | S & F in repair Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) in repairs including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed. |
| 54 | M&L for 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 55 | Supply fix in repairs Viterous China wash down water closet pan (pedestal pattern), white and trap, including connection to drain(or outgoing pipe) and to flushing pipe, anti-syphonage pipe etc, complete all as specified and directed. |
| 56 | S&F in repairs vitreous us china squatting pan `ORISSA` pattern size 580 x 440 mm with integral foot rests including connection to trap and to flushing pipe, anti-syphonage pipe and provision of concrete bedding complete making good floor all as specified and directed. |
| 57 | S&F in repairs of Vitreous China bowl urinal flat back size 465x355x265mm white (minimum) (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe all as specified and directed. |
| 58 | S&F in repairs urinal spreader of chromium plated push type with PVC pipe of 15mm bore as required complete all as specified and directed. |
| 59 | S & F in repairs Vitrous China urinal partition white of size 310x700mm complete all as specified and directed. |
| 60 | S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 61 | S&F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints any size including fixing to steel pipe or union complete all as specified and directed. |
| 62 | S&F plastic water closet seat cover, white closed pattern with flat bottom and cover and mild steel C.P or Aluminium hinging device all as specified and directed. |
| 63 | S&F PVC low level flushing cistern 10 ltrs capacity including all fittings and brackets bends flush pipe etc and fixed in repairs complete all as specified and directed. |
| 64 | S/F in repair PVC connection (high density) 15 mm dia 600 mm with PTMT nuts both ends with rubber washer all as specified and directed. |
| 65 | S/F in repair PVC connection (high density) 15 mm dia 450 mm with PTMT nuts both ends with rubber washer all as specified and directed. |
| 66 | S & F for 2000 ltr capacity rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks exc 1000ltr but n exc 2000 ltr and removing to store complete all as specified and directed. |
| 67 | S & F for 1000 ltr capacity rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks exc 500ltr but n exc 1000 ltr and removing to store complete all as specified and directed. |
| 68 | S & F in repairs fancy type chromium plated 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 69 | S&F in repair 15 mm dia bib taps, cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down screwed for iron pipe of for brass ferrule complete all as directed including taking down old one complete all as specified and directed. |
| 70 | S & F in repairs 15 mm bore pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 71 | S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs complete all as specified and directed. |
| 72 | S&F in repair 75mm bore PVC (SWR) soil, waste and vent pipes single socketed in any legth with rubber ring joints laid in floors or trenches all as specified and directed. |
| 73 | S & F in repair 110 mm bore PVC (SWR) , waste and rain water pipes single socketed in any length with rubber ring joints complete all as specified and directed. |
| 74 | S & F in repair 75 mm bore PVC (SWR) bends of any radius.complete all as specified and directed. |
| 75 | S & F in repair 110 mm bore PVC (SWR) bends of any radius.complete all as specified and directed. |
| 76 | M & L 75 mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 77 | S & F in repair 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door all as specified and directed. |
| 78 | S&F in repair Waste pipes 32 mm dia LDPE ,UPVC pipes of pressure rating 6 Kg/cm2 for wash basins and urinals all as specified and directed. |
| 79 | S&F in repairs grating round of size 75mm dia, chromium plate complete all as specified and directed. |
| 80 | S&F in repair health faucet chromium plated with CP pipe of 1.4m long with jet spray with PVC chord and connector complete all as specified and directed. |
| 81 | S&F in repair wall mounted stainless steel (gde 304) toilet paper holder with flap of weight not less 300 gms complete all as specified and directed. |
| 82 | S & F in repair soap dish vitreous china white of size 160x160x90 mm fixed to plug with chromium plated brass screw complete all as specified and directed. |
| 83 | S&F in repair chromium plated tubular towel rail D Type of 20mm dia bore and 600mm long comlete all as specified and directed. |
| 84 | S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and directed. |
| 85 | S&F 110mm bore PVC SWR P trap complete all as specified and directed. |
| 86 | S&F 110mm bore PVC SWR S trap complete all as specified and directed. |
| 87 | Removing builiding material (concrete, tiles, demolished rubbish) to outside Dockyard permises,not less than 5Km, including loading, unloading stacking at the directed destination complete all as specified and directed. |
| 88 | Providing double steel scaffolding for the outer surfaces of the building to provide platform to the workmen complete all as specfied and directed. Note : The superficial area of the building cover is measured |
| 89 | S&F plain, solid, 2nd hard wood class straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with the glue pinned at joints as in doors and windows with 2nd class hardwood complete all as specified and directed. |
| 90 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 91 | S&F 30mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers boards on both side with lipping/frame to match all as specified and directed. |
| 92 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 93 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specfied and directed |
| 94 | Demolition of stone slabs and tiles of any description or thicknes in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 95 | Material & labour for granite (any type) work (table rubbed and polished) 18 to 20 mm thick in steps, jambs,pillars,window-cills, cooking platform and like in floor etc,. over 20mm screed bed cement mortar (1:4) including pointing in white cemnt (1:2) using marble dust with admixture of pigment to match complete all as specified and directed. |
| 96 | Material & labour for rounding to edges of granite stone slabs one edge such as in counter type WHB platform, steps etc., complete all as specified and directed. |
| 97 | M&L for 25 mm thick cement concrete type 'B-0' 1:2:4 using 12.5mm graded stone aggregate as in flooring all as specified and directed. |
| 98 | M&L for Light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick cement mortor (1:6) screed bed complete all as specified and directed. |
| 99 | M&L light shed vitrified ceramic tiles 10 mm thick (square/ rectangular) polished as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick 1:4 cement morter complete all as specified and as directed Please Enable Macros to View BoQ information |