| 1 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided and removing demolished material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified & directed. |
| 2 | Dismantling floor earth or wall tiling including Cement Mortar bedding (but not backing and rubbish off premises complete and M & L Light shade Vitrified tiles 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor complete all as specified and directed. |
| 3 | Dismantling floor earth or wall tiling including cement mortar bedding(but not b acking and rubbish)off premises complete and M & L Light shade vitrified tiles 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles but in vertical surfaces complete all as specified and directed. |
| 4 | Dismantling floor earth or wall tiling including cement mortar bedding (but notbacking and rubbish) off premisesncomplete and M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 5 | Dismantling floor earth or wall tiling including cement mortart bedding (but not backing and rubbish)off premises complet and M&L for Non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 6 | Dismantling floor earth or wall tiling including cement mortart bedding (but not backing and rubbish) off premises complete & M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 7 | M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 8 | M&L for rendering 10 mm thick in CM 1:4 on brick or concrete surface complete all as specified and directed. |
| 9 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed. |
| 10 | Demolition of brickwork or stone boulder masonry complete &M&L Brick work with flyash bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 11 | M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 12 | M&L Rendering on fair faces of brick work or concrete surfaces of wall 15 mm thick in CM 1:6 and to be finished even and smooth without using extra cement incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed. |
| 13 | M&L Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finish the surfaces even and smooth without using extra cement incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified in SSR Pt-I . and all as specified and as directed,. Note (i) :- (a) Liquid WPC will be measured and paid separately. |
| 14 | M&L Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified in SSR Pt-I . and all as specified and as directed,. . |
| 15 | Supply only water proofing compound (liquid), ISI marked complete all as specified and directed. |
| 16 | M&L for Preparing and applying 1 mm thick Birla / JK Putty in two layers on newly plastered wall surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 17 | M&L for applying Birla / JK Putty on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, through putty sprayer/ manually and rubbing with sand paper for further coat of OBD/ Paint etc complete all as specified and directed. (Note : Minimum thickness of putty layer is 0.50 mm.) |
| 18 | M&L for Preparing and applying 1 mm thick Birla / JK Putty in two layers on newly plastered ceiling surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 19 | M&L for applying Birla / JK Putty on old Ceiling surfaces including complete removal of existing Ceiling finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, through putty sprayer/ manually and rubbing with sand paper for further coat of OBD/ Paint etc complete all as specified and directed. (Note : Minimum thickness of putty layer is 0.50 mm.) |
| 20 | M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 21 | M&L for applying two coats of oil bound distemper on Ceiling surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 22 | M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed. |
| 23 | M&L for preparation of newly plastered surfaces of ceilings and apply three coat of white wash complete all as specified and directed. |
| 24 | M & L for two coats of cement based paint on new plastered surface of walls including preparation of surface complete all as specified and directed. |
| 25 | M&L for Complete removal of existing treatment and applying two coats of OBD over a coat of primer on wall Surfaces complete all as directed by Engineer-in-Charge. |
| 26 | M&L preparation of old painted surfaces and applying one coat of white wash on walls complete all as specified and as directed. |
| 27 | M&L preparation of old painted surfaces and applying one coat of white wash but on ceiling complete all as specified and as directed. |
| 28 | M&L preparation of old painted surfaces and applying one coat of oil bound distemper on walls complete all as directed. |
| 29 | M&L preparation of old decorated wooden painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 30 | M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 31 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed. |
| 32 | M&L applying two coats Cement based paint on old decorated wall surfaces, includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 33 | Taking down eaves gutters and rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. |
| 34 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed. |
| 35 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 36 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed. |
| 37 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 38 | S&F PVC(SWR) bends, any radius of 110 mm bore without access door complete all as specified and directed. |
| 39 | S&F PVC(SWR) bends, any radius of 110 mm bore with access door complete all as specified and directed. |
| 40 | S & F PVC(SWR) Tee of 110mm dia etc complete all as specified and directed. |
| 41 | S&F PVC(SWR) bends, any radius of 75 mm bore without access door complete all as specified and directed. |
| 42 | S&F PVC(SWR) bends, any radius of 75 mm bore with access door complete all as specified and directed. |
| 43 | S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 110 mm dia with access door complete all as specified and directed. |
| 44 | S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 75 mm dia with access door complete all as specified and directed. |
| 45 | S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed. |
| 46 | S&F in repairs PVC (SWR) Floor trap of diameter of outlet 75 mm, plain with grating including jointing with solvent cement 75mm dia etc complete all as specified and directed. |
| 47 | S&F in repairs PVC (SWR) 'P' trap for 110 mm dia etc complete all as specified and directed. |
| 48 | S&F in repirs PVC (SWR) 'S' trap for 110 mm dia etc complete all as specified and directed. |
| 49 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 250 ltr n.exc 500 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder @ 0.25 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 50 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 500 ltr n.exc 1000 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using with bleaching powder @ 0.50 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 51 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 52 | S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 53 | S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 54 | S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 55 | S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 56 | S & F Powder coated three track Aluminium sliding window with frame of cross section not less than 101 mm x 44 mm and not less than 1.8 mm thick and window shutters cross section not less than 91.80 mm x 31.75 mm and not less than 1.50 mm thick excluding aluminium grill and including 4 mm thick tinted glass, beading & necessary rubber packing, locking & opening arrangement, all fitting and fixture complete all as specified and directed. |
| 57 | S&F Powder coated aluminium ventilator cross section 63.50 mm x 38.10 mm x 1.50 mm consisting of two portions upper portion shall have louvers with 3 mm thick pin headed glass and aluminium wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40 mm fixed with aluminium beads and securing on outer face of frame and lower portion of ventilator shall be fixed with 3 mm thick pin headed glass with IDPE rubber gasket including aluminium beads including prepartion of jambs all around in CM 1:3 finishing even and smooth complete all as specified and directed. |
| 58 | S&F in repairs door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight between 36 to 60 Kg of aluminium (Die cast) body complete all as specified and directed. |
| 59 | S&F in repairs Aluminium Mortice lock 2 lever, vertical type, size 100 mm with escutcheon plates and two keys complete all as specified and directed. |
| 60 | S&F in repairs Aluminium Mortice lock 4 lever, vertical type, size 100 mm with escutcheon plates and two keys complete all as specified and directed. |
| 61 | S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 62 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 63 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 64 | Taking down shutter of any description area exceeding 1 sqm but n exc 2 sqm each and removing to store complete all as specified and directed. |
| 65 | Taking down shutter of any description area not exceeding 1 sqm each and removing to store complete all as specified and directed. |
| 66 | M&L Second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 67 | M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed. |
| 68 | S&F hollow PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube in opening as per specification and shown on drg SSR Part-II 2010. |
| 69 | S&F, factory made hollow panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rails lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement , as per specification and shown on drawing in SSR Part-II (2020). |
| 70 | S&F Flush shutters 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed. |
| 71 | M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 72 | Taking down shutter of any description not exceeding 1 sqm each leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 73 | Taking down shutter of any description exceeding 1 sqm but not exiding 2 Sqmeach leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 74 | S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, brackets for WHB, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 75 | M&L for Cutting holes in brick walls exc half brick but not exc one brick built in cement mortor or cement lime mortor and stone walls built in lime mortor for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. |
| 76 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed. |
| 77 | S&F 150 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed |
| 78 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 79 | S&F 75 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 80 | S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 81 | S&F in repair 150 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed |
| 82 | S&F in repair 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed. |
| 83 | S&F in repair 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 84 | S&F in repair 75 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed. |
| 85 | S&F in repair 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 86 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, over all length of cover plate 140 mm with hard drawn steel spring fixed in door etc complete all as specified and directed. |
| 87 | S&F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 88 | S&F in repairs 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 89 | Hacking out old broken glass (any thickness, size quality or description) form wooden frames or stone, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed. |
| 90 | S&F 3 mm thick sheet glass ordinary quality and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 91 | S&F 3 mm thick figured glass pin headed type and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 92 | S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 93 | S&F in repairs door seal with aluminium beading and 50 mm wide rubber seal complete fixed to aluminium/ Wooden doors complete all as specified and directed. |
| 94 | Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed. |
| 95 | M&L for Fe 410-W (Gde E-250 quality A) Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc complete all as specified and directed |
| 96 | M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed |
| 97 | S&F in repairs 18/19 mm thick high density PVC/ WPC solid fibre board with prelaminated PVC sheet as Kitchen cupboard and frame including taking down the old cupboard shutters and removing to store complete all as specified and directed. |
| 98 | S&F continuous (piano) hinges of width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised complete all as specified and directed. |
| 99 | S & F magnetic catcher with nut and screw of mild steel bright finish all as specified and directed. |
| 100 | S & F 40 mm dia cupboard knobs fixed with nuts screw and washer of mild steel bright finish complete all as specified and directed. |
| 101 | S & F in repair 40 mm dia cupboard knobs fixed with nuts screw and washer of mild steel bright finish complete all as specified and directed. |
| 102 | S & F in repair hasp and stapple safety type aluminium anodised 75 mm long with mild steel hinge pin including bolt to hinge plate fixed with screw complete all as specified and directed. |
| 103 | S & F in repair Toilet Paper Holder with Flap complete all as specified and directed. |
| 104 | S & F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 105 | S&F in repair single door PVC cabinet mirror of size 350 mm x 450 mm with internal shelves all as specified and directed. |
| 106 | S&F in repair sliding door PVC cabinet mirror of size 600 mm x 450 mm with internal shelves all as specified and directed. |
| 107 | S & F in repair sheet Glass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed.. |
| 108 | Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed. |
| 109 | Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed. |
| 110 | S&F GI tubes medium grade (ISI marked) with all fittings fixed complete to walls, ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed. |
| 111 | S&F GI tubes medium grade (ISI marked) with all fittings fixed complete to walls, ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed. |
| 112 | S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified |
| 113 | S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified |
| 114 | Making connection of PPR distrubtion bracnch with PPR main of following outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc |
| 115 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed. |
| 116 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed. |
| 117 | S&F in repair Bib taps fancy type chromium plated 15 mm dia, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 118 | Taking down bib tap /wash basin tap/pillar tap/stop cock/mixture tap and refixing the same after repair and replacement of spindles for 15 mm bore size complete all as specified and directed. |
| 119 | S & F in repair Brass chromium plated wall mixer non-telephonic shower arrangement with connecting legs & wall flanges for 15 mm bore of pipe all as specified and directed. |
| 120 | S & F in repair Brass chromium plated hole bidet mixer (Basin mixer) with pop-up waste system with 300 mm long braided hoses complete all as specified and directed. |
| 121 | S & F in repair Brass chromium plated Swan Neck Sink mixer with raised J shaped swinging spout (Wall mounted model) with connecting legs & Wall flanges complete all as specified and directed. |
| 122 | S&F in repair Chromium plated fancy type Stop valves 15 mm, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 123 | S&F in repair, 15 mm bore stop cock, cast copper alloy with long shank and cup (concealed type) fancy type chromium plated screwed down high pressure with crutch & butterfly handle screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 124 | S&F in repair pillar tap cast copper alloy with capstan head chromium plated crewed down high pressure with or without lettered hot or cold with long screwed sharks and ply nuts 15 mm dia complete all as specified and directed. |
| 125 | S & F in repair bottle trap chromium plated for WHB as per approved quality all as per specified and directed. |
| 126 | S&F in repair PVC waste pipe for WHB etc all as specified and directed. |
| 127 | S&F in repairs 32 mm bore dia waste coupling of (min weight 32 mm-45 gm of PTMT) (half or full threaded) etc complete all as specified and directed |
| 128 | S&F in repair CP grating 100 mm dia with waste hole (minimum weight 40 gm) complete all as specified and directed |
| 129 | S & F in repair CP Jet spray for 15 mm bore all as specified and directed. |
| 130 | S & F in repairs Health faucet (ABS Body) mild steel pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 131 | M&L in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mm including supply & fixing of brass chromium plated coupling 32 mm etc complete all as specified and directed. |
| 132 | M&L in repairs vitreous china squatting pan , ‘Orissa’ Pattern, size 580 X 440 mm white, with integral foot rests etc. complete all as specified and directed. |
| 133 | M&L in repair Wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed. |
| 134 | S&F in repairs plastic water closet seat cover, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 135 | S & F in repair Kitchen sink made of stainless steel 1 mm thick with plug washer and waste pipe incl bedding fixing cantilever brackets and connetction union to pipe overall size 915 X 460mm bowl size 405X 355 mm complete all as specified and directed |
| 136 | S& F in repair 1 mm thick stainless steel plate rack of size 900X900X200 incl fixing with rawal plug and screws complete all as specified and directed. |
| 137 | S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed |
| 138 | S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed |
| 139 | S&F ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 140 | S&F ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 141 | S&F in repairs, PVC valveless syphonic action type low level flushing cistern, 10 ltrs capacity with inlet, ball valve, float and handle including bracket complete all as specified and directed |
| 142 | S & F in repair internal fitting for low level flushing cistern (Syphon) complete all as specified and directed. |
| 143 | S&F in repairs flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cistern complete all as specified and directed. |
| 144 | S & F in repair 125 mm dia chromium plated shower rose of with or without swivel joint incl fixing to steel pipe complete all as specified and directed. |
| 145 | S&F in repair PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and directed. |
| 146 | S&F in repairs CP anodised tubular tower rail, 20 mm dia, D type, 60 cm long between flanges etc. |
| 147 | S & F in repair Soap dish any type fixed to plug with chromoium plated brass screw complete all as specified and directed. |
| 148 | S & F in repair Corner glass shelf with brackets complete all as specified and directed. |
| 149 | S & F in repair Europian WC floor/ Wall mounted cascade pattern vitreous china with dual core flushing cistern incl all fitting flush pipe etc complete all as specified and directed. |
| 150 | S & F in repairs Magic Eyes for door eye viewers brass body complete all as specified and directed. |
| 151 | S&F in repairs Stainless Steel Towel Rack 600 mm long with Lower Hangers but with 3 hooks complete all as specified and directed. |
| 152 | S & F in repair chromium plated towel ring with bracket complete all as specified and directed. |
| 153 | S&F in repair Stainless steel fancy type curtain rod 25 mm dia as approved complete all as specified and directed |
| 154 | S&F in repair SS Curtain rod Bracket fancy type for curtain rod 25 mm dia of any colour as approved complete all as specified and directed. |
| 155 | Taking down carefully copper / aluminium point wiring (light, fan, sockets or power) complete including all fittings and fixtures such as switches, sockets, ceiling roses, pendens, regulators, light fittings etc, removing materials to store for taking credit and making good disturbed surfaces complete all as specified and directed. |
| 156 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module and blank plates, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. |
| 157 | Description all as per ser item No. 156.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch complete all as specified and directed. |
| 158 | Description all as per ser item No. 156.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch complete all as specified and directed. |
| 159 | Description all as per ser item No. 156.00 above but for one light point controlled by one, 2 way 5/6 Amps switch complete all as specified and directed. |
| 160 | M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. |
| 161 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through PVC casing and caping of suitable sizes (medium grade ISI marked ) in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame of any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. |
| 162 | Description all as per ser item No. 161.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps complete all as specified and directed. |
| 163 | Description all as per ser item No. 161.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch complete all as specified and directed. |
| 164 | Description all as per ser item No. 161.00 above but for one light point controlled by one, 2 way 5/6 Amps switch complete all as specified and directed. |
| 165 | M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including rigid,non-metallic PVC casing and caping (medium grade) on wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. complete all as specified and directed. |
| 166 | S&F in replace Ceiling rose 3 terminal AC 230 V, 50 Hz ISI Marked all as specified and directed. |
| 167 | S&F in replace modular switch 1 way 6A, 1 module, ISI Marked complete all as specified and directed. |
| 168 | S&F in replace modular switch 2 way 6A, 1 module, ISI Marked complete all as specified and directed. |
| 169 | S&F in replace modular bell push one way, 5/6 Amp, 240 V ISI Marked complete all as specified and directed. |
| 170 | S&F in replace modular switch 1 way 16A, 1 module, ISI Marked complete all as specified and directed. |
| 171 | S&F modular socket outlet, 6A - 2/3 pin combined 2 module, ISI Marked complete all as specified and directed. |
| 172 | S&F modular socket multipurpose 6/16A, 2 module, ISI Marked complete all as specified and directed. |
| 173 | S&F stepped type electronic modular fan regulator - 2 module, with 5 step, AC 50 Hz, 230/240 Volts grade, ISI Marked complete all as specified and directed. |
| 174 | S&F call bell, ding dong, AC 230 V, 50 Hz complete all as specified and directed. |
| 175 | S&F TV socket outlet ISI Marked complete all as specified and as directed. |
| 176 | S&F modular type angular lamp holder, PVC / Polycarbonate fancy type with back plate 230 V, 50 Hz including taking down complete all as specified and as directed. |
| 177 | S&F in replacement of pendent lamp holder, brass body for decorative wall fittings complete with mounting clamp (as per sample) for fixing inside wall mounted luminaire 240 volt complete all as specified and as directed. |
| 178 | S&F in replacing 9 watt LED lamp warm white(5 star rated) threaded with B22 base including taking down complete all as specified and as directed. |
| 179 | S&F in replacing decorative ultra slim poly carbonate LED tube light fitting 4 feet long 22 watts with THD less than 15% very high efficiency suited for T-8 tube light luminaire with system efficiency 110 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing complete all as specified and directed. |
| 180 | S&F in replacing wall mounted 10 watts LED batten 2 feet long comprising extruded aluminium heat shrink provided for efficient heat dissipation & integrated electronic driver with aluminium housing system efficiency of 110 lumen per watt and lumen package ≥1100 lumen, THD < 10% complete all as specified and directed. |
| 181 | S&F MCB SPN 20 to 32 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed. |
| 182 | S&F MCB SP 6 to 32 Amp, 10 kA breaking capacity, 'C' curve complete all as specified and as directed. |
| 183 | M&L for MCB two way centre off change over switch 40 Amps, for duel electricity supply management complete all as specified and directed. |
| 184 | M&L for flexible wire twisted 23/0076 of size 1.5 sq. mm for replacing from ceiling rose to light fittings/ceiling fan/exhaust fans complete all as specified and directed. |
| 185 | S&F in replace 3 core copper flexible cable 2.5 sqmm complete all as specified and directed. |
| 186 | M&L for Blank Plate 01 Module complete all as specified and directed. |
| 187 | Supply and fixing round plate PVC as existing size all as specified and directted b rengr-in-charge |
| 188 | M & L sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 189 | M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of , all as shown in electrical plate No. 3 connected to earthing test point and complete all as specified and directed.Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 (using 20 mm grade crushed stone aggregate) earth chamber, RCC 1:1.5:3, type A-1 cover slab, 40 mm thick reinforced with 6 mm dia TMT bar @ 150 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc. |
| 190 | S & F digital type single phase electric energy meter 230 volt 10 amp to 60 amp all as specified and directed by engr-in-Charge |
| 191 | S & F digital type three phase electric energy meter 440 volt 10 amp to 60 amp all as specified and directed by engr-in-Charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail