| 1 | Repairs to plaster in patches of 2.5 sq.m. and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping g within 50m lead. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 2 | Dismantling doors, windows and clearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt. Lead - Of area 3 sq.m. and below |
| 3 | Scraping of existing Neeru/POP /wall putty from the wall /ceiling surface so as to expose the existing plaster including disposal of all rubbish /dust created at all leads and lift as directed by Engineer |
| 4 | Brick work using fly ash bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with bricks of class designation 40 kgs / cm2. in superstructure upto floor five level 230 x 110 x 80 mm |
| 5 | Providing and laying Half brick masonry using fly Ash bricks in cement mortar 1:3 (1 cement : 3 coarse sand ) with bricks of class designation 40 kgs / cm2. Above plinth upto floor V level 200 x 95 x 95 |
| 6 | Providing & laying cement concrete 1:2:4 (1 cement: 2coarse sand: 4 graded granitic or basaltic stone aggrt. 10 mm. nominal size) screed as per required thickness in floors upto floor five level excluding cost of centering, shuttering and finishing. All works upto plinth level |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923/Rectangular Hollow Section (RHS) IS4923/Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA, VIZAG, JSW, APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position & applying a priming coat of approved steel primer, including welding & bolted with special shaped washers etc. complete |
| 8 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 9 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 10 | Wall painting (one or more coats) with plastic emulsion paint of approved brand and manufacture on old work to give an even shade. |
| 11 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture including applying one coat of cement primer of approved brand and one coat of surface treatment on all types of plastered surfaces etc. complete. |
| 12 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | Providing and applying Matt finish scratch resistance Melamine polish on wood /veener work by sanding of wooden /veener surface first with 80 grit rough polish paper followed by sanding surface with 120 grit smooth polish paper followed by cleaning of sanded wooden /veener surface with dry cloth thereafter approved quality and make melamine sealer mixed with approved quality NC thinner in 1:5 to be sprayed/brushed to provide uniform coat thereafter sealer coat shall be allowed to dry for 12 hours.On drying the sealer coat, the surface is sanded with smooth water paper [150 or 200 No.] to remove the excess sealer layer and to make the surface further smooth. Further, approved Special filler pastes of required stains shall be filled in the small or large holes. After the filler dries in about 4 to 6 hours, light sanding with water paper shall be once again done & the surface shall be allowed to air dry for about 12 hours. Thereafter approved quality Melamine polish mixed with approved hardener is sprayed by a spray gun by a compressor.After the first coat of melamine polish is dried, that is after about 24 hours the surface is sanded thoroughly with smooth water paper of 220 grit & the surface is then allowed to air dry for about 12 hours.The final coat shall then be given by spraying melamine as in the first coat. The cost shall be inclusive of material, labour, scaffolding, transportaion etc all complete. |
| 14 | Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 15 | Painting (one or more coats) with synthetic enamel paint of approved brand and manufacture in all shades on old work to give an even shade. |
| 16 | Supplying and installing 2 mm thick homogeneous / heterogeneous vinyl flooring sheet of approved make, shade and design as provided by the Consultant / Architect, including necessary surface preparation, cutting to size, laying with approved adhesive, welding the joints with matching color vinyl welding rods, rolling, finishing and cleaning the surface complete. |
| 17 | Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building). (b) Post-construction |
| 18 | Waterproofing of sunken slabs, toilet blocks, terraces on slabs under brickbats, roofs, watertanks. Cleaning the surface and filling cracks (if any), applying EPCO ACR wherever necessary, Providing and Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in the ratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12 hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure with sprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent |
| 19 | Supplying and fixing glass panes with putty and nails including removal of broken glass panes wherever necessary - Glass panes 3mm thick |
| 20 | Providing and Fixing of Artwork on walls of Size 8ft high x 4ft wide in Digital Images Scanned and Printed in High resolution on UV resistant Vinyl pasted on 4mm Foam board/\\"sunboard and mounted on a wooden frame of 3inches x 2 inches on all 4 sides of the artwork including Transport and Installation complete in all respects. |
| 21 | Providing and Fixing Wall mural tiles baked 6\\"x 6\\" Azulejos tiles All works shall be completed as per the drawing, specification and direction of the Engineer. |
| 22 | Supplying and placing in specified position Straight Bench from approved brand / manufacturer, model, colour and finish having features of dimensions- 1200mm in lenght with 1 number Turning Bench of dimensions- 720 x 720mm Depth of Bench 600mm. the bench is to be Made of 15 mm & 8mm Thick Plywood, 30 mm Thick Plywood Battens with metal Legs . the seat to be made with PU Seat Foam with Density - 40 kg/m3, Thickness - 60 mm. Side Foam : Density - 28 kg/m3, Thickness - 6 mm the bench should be with Writing Shelf x 1 qty (350W, 560D) Made of 19 mm Thick MDF and Painted: WH-White 19 OD X1.5mm THICK STAINLESS STEEL PIPE (304 GRADE). Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 23 | Supplying & placing in specified position POUFFE from approved brand / manufacturer, model, colour and finish and having features overall size +/-50mm height 430mm and Diameter 470mm. The Body of the pouffe is to be Made of 15 mm Thick Plywood, Wooden Battens & Flexi Ply. Seat is made of PU foam with density 40kg/m3 and foam Thickness of 100 mm. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 24 | Supplying and placing in specified position Medium Back Mesh finish chair from approved brand / manufacturer, model, colour and finish with Overall Height - 950 - 1050mm, Overall Width - 620mm, Overal Depth - 680mm, Seat Height - 495 - 595mm Seat Width - 510mm, Seat Depth - 510mm, Frame Material - Nylon Back Height - Medium Back, Back Finish - Mesh with Adjustable lumber support, BackMesh - Polyster Mesh, Seat Fabric - Polyster with PU Foam , Seat Height Adjustable with gas Lift, Mechanism Type - Synchronized Tilt, Back Lock - Upright position, Back Tilt Tension - Adjustable via Knob, Armrests Type - Fix arms in Polypropelene, Base Type - Nylon 5-Star Base, Castors - 50mm hooded, Greenguard Certified for Low Chemical Emission. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 25 | Supplying and placing in specified position work station from approved brand / manufacturer, model, colour and finish of Size 900mm X 600mm D X 745 HT Table top : 25mm thick Prelam particle board finish with Prelam particle board finish with pvc edge Liping and worktop height 745mm from ground level. Electrical : Metal powdercoated access flap (300mm) above the worktop for electrical access, metal powdercoated electrical panel below worktop to carry cables through it. Legs : Metal powdercoated League Plus 50x50 Square Open legs to support the worktop. Front Modesty Panel : Metal powdercoated front modesty panels of 300mm H with Square slots. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 26 | Supplying and placing in specified position PEDESTAL DRAWER UNIT of size Size: 400W X 450D X 621H from approved brand / manufacturer, model, colour and finish 3 drawer Pedestal ( 2D+1FD ) OSL Prelam Particle board pedestal on castors with Side Chamfer side edge , central locking, 18 thick back. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 27 | Supplying and placing in specified position ISSUE COUNTER TABLE/ RECEPTION TABLE of size1800 L X 475 D X 1185 H with side storage of size Size: 900W X 450D X745H from approved brand / manufacturer, model, colour and finish with Work top thickness is 25mm in Prelam particle board with wire manager hole 25mm thick particle board Gable ends with PVC edge lipping. 18mm thick particle boar d Front panel with PVC edge lipping. 25mm prelam particle board top. 18mm thick particle board Modesty panel with PVC edge lipping. Prelam particle board Lockable drawer on one side Side Combo Storage : One Openable doors + 2 Drawer+ 1 Filling Drawer OSL Prelam Particle board combo storage with pvc edge Lipping on leveler and 18 Thick Back, Chamfer , Handle central locking (Size: 900W X 450D X745H). Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 28 | Supplying and placing in specified position NEWS PAPER READING TABLE Meeting Table Size : 1600L X 1100 D X 745 HT from approved brand / manufacturer, model, colour and finish Table Top :25 mm Thk. Prelam Table Top With 2 mm Thk. Flat Edge PVC Lipping. & Worktop height 745 mm from ground level . End Leg : Metal Powder Coated Avail Curved leg. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 29 | Supplying and placing in specified position D SHAPE MEETING TABLE from approved brand / manufacturer, model, colour and finish of Size : 1800L X 1200 D X 745 HT (WITH 1 ACCESS FLAP ) Table Top :25 mm Thk. Prelam Table Top With 2 mm Thk. Flat Edge PVC Lipping. & Worktop height 745 mm from ground level . End Leg : Metal powdercoated League Plus 50x50 Square Open legs & Metal powder coated pole understructure to support the worktop. Electrical : Metal Powdercoted access flap 450mm above the worktop for electrical, metal powdercoated Vertical duct for wire travel from ground. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 30 | Supplying and placing in specified position METAL LIBRARY BOOK STORAGE from approved brand / manufacturer, model, colour and finish of Size : 900 X 450 X 2185 HT METAL CABINET WITH GLASS DOOR 900X450 X1660HT+ 525 HT ADDON Unit . Total height 2185mm. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. |
| 31 | Supplying and placing in specified position PRELAM LIBRARY STORAGE Shelf from approved brand / manufacturer, model, colour and finish of following sizes With Skirting made from 18mm Thk Prelam Boards straight PVC Lipping. Rate shall include of all iron mongeries hardware,fittings,fixtures etc. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.SIZE : 900 L X 450 D X 2100 HT |
| 32 | ELECTRICAL WORKPOINT WIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C -- with Cat A Modular Accessories |
| 33 | Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 34 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. Cat A |
| 35 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc as required. Cat A |
| 36 | Supplying and fixing 20 A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alon with 20 A, C series SP MCB in sheet steel enclosure in surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioning etc. as required\\" Cat A |
| 37 | CIRCUIT WIRINGWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 38 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit) |
| 39 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. 2 x 6 sq.mm + 1 x 6 sq.mm earthwire (25mm Conduit) |
| 40 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm Conduit) |
| 41 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. 4 x 10 sq.mm + 2 x 10 sq.mm earthwire (32mm Conduit) |
| 42 | DBs, MCBs, RCCBs etc.Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)8 way (8+24), double door, Horizontal type Cat B |
| 43 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)(j) 8 way single door Cat B |
| 44 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.SP, Cat B |
| 45 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.DP, Cat B |
| 46 | Supplying and fixing 40 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(i) TP, Cat B |
| 47 | Supplying and fixing following rating double pole (single pole and neutral) 240 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required25 A, Cat B |
| 48 | Supplying and fixing following rating double pole (single pole and neutral) 240 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required40A ,Cat B |
| 49 | LIGHT FITTING Supply, installation, testing and commissioning of 36W, 5700 K ,1200mm Linear recessed luminaire, housing made of extruded aluminium with a satin finish PMMA diffuser for standalone and seamless end to end connectivity inclusive of all accessories. |
| 50 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. (b) Cat B |
| 51 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required(b) Cat B |
| 52 | Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-45 connector(modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. CAT A |
| 53 | Supplying and fixing Cat 6, 24 port patch panel with keystone jacks compliant with ANSI/TIA/EIA 568.C.2 & ISO/IEC 11810 complete as per specification no. WG-NAS/PP |
| 54 | Supplying and fixing 3 m 24 AWG multi stranded UTP patch cord with RJ-45 factory crimped connector of cat 6 type compliant ANSI/TIA-568.2-D standards in position as per specification no.WG-ELVC/PC |
| 55 | Supplying and drawing of Cat - 6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVC sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required Cat 6 |
| 56 | Supplying, erecting & terminating 10 m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19pin HDMI connectors complete. |
| 57 | Supplying, fixing, and configuring 24 Ports + 4 SFP combo, layer 2, GB managed ethernet switch, with web view compliant with IEEE 802.3 standards erected in provided rack complete |
| 58 | FIRE EXTINGUISHERSSupplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with ecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 59 | INVERTERSupplying, installing, testing and commissioning of single phase, 230V, 50 Hz,1400 to 1600VA digital pure sine wave inverter with backup time of 1. hrs.based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV |
| 60 | Supplying and erecting 12 V/180Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complet |
| 61 | DismantlingDismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc.complete as per specification No: WG-DM/PW |
| 62 | Dismantling the existing Telephone / Lan / Wan / TV cables and wires of all sizes along with casing-capping / conduit complete as per specification No: WG-DM/PW |
| 63 | Dismantling the existing Aluminium/copper mains,submains wiring upto 10 sq.mm. along with accessories etc.Complete as per specification No: WG-DM/PW |
| 64 | Dismantling the existing W.T. fluorescent fitting / S.V./ M.V. / M.H. lamp /LED fitting from wall with brackets and making the site as original complete. |
| 65 | AIRCONDITIONERSSupplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 tomaximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC Please Enable Macros to View BoQ information |