| 1 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC.Two coats.Fourth Floor. |
| 2 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Super protective 100 % Acrylic Emulsion.Fourth Floor. |
| 3 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : |
| 4 | i) On metal surface With super gloss (hi-gloss) Two coats (with any shade except white). |
| 5 | ii) On wooden surface With super gloss (hi-gloss) Two coats (with any shade except white). |
| 6 | iii)Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 7 | iv)Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 8 | French polishing to wood work including preparing surface (High gloss) On old French polished surface including complete removal of the old polish. |
| 9 | Polyurethane Polishing to woodwork with required colour as approved by Engineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardener material such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as per direction of Engineer-in- Charge. |
| 10 | Painting with superior quality aluminium paint of approved make and brand including smoothening surface by sand papering etc. on steel surface: Two coats. |
| 11 | 125 mm. thick Fly ash brick work as per IS 12894:2002 in cement mortar (1:4) in ground floor. |
| 12 | 250 mm thick Brick work with Fly Ash Bricks (250mm x 125mm x 75mm) as per IS 12894:2002 in cement mortar (1:6) a) In foundation and plinth |
| 13 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 14 | Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. |
| 15 | Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor [Pakur Variety] (1:3:6). |
| 16 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur variety. Up to fourth floor. |
| 17 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing (a) For works in foundation and upto roof of ground floor/upto 4 m and direction. (i) Tor steel/Mild Steel II. Other manufacturers not specified. |
| 18 | Anti-termite treatment to the soil under floor and the junction of wood work and masonry walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight including drilling vertically & horizontally at the junction of floor and wall at 450 mm. interval below using hand operated pressure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes as per manufacturers specification. The holes shall be sealed after operation to match with the existing floor and wall. The shutters are to be sprayed with emulsion on both sides. The entire work is to be carried out as per specification of Code I.S.-6313 (Part-III)-1981 and as per direction of the Engineer-in charge. |
| 19 | Stripping off worn out plaster and raking out joints of walls, ceilings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 20 | Applying 2 coats of bonding agent with synthetic multi-functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification. |
| 21 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster. |
| 22 | Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m). |
| 23 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia. bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia. bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-in charge. (This item should be executed only after prior approval of the Engineer-in charge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. |
| 24 | i) a) 3.90 metre height |
| 25 | b) Extra for additional 3.6 height or part thereof |
| 26 | c) Extra for additional 3.6 height or part thereof |
| 27 | d) Extra for additional 3.6 height or part thereof |
| 28 | e) Extra for additional 3.6 height or part thereof |
| 29 | ii) Labour rate for shifting |
| 30 | a) 3.90 metre height |
| 31 | b) Extra for additional 3.6 height or part thereof |
| 32 | c) Extra for additional 3.6 height or part thereof |
| 33 | d) Extra for additional 3.6 height or part thereof |
| 34 | e) Extra for additional 3.6 height or part thereof |
| 35 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 connected to one another with bracket, gusset leats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 2004, haulage, hoisting and erection all complete. The rates includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular members as specified in relevant IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For trusses spanning up to 12.00 m. |
| 36 | Supplying, fitting & fixing polycarbonate sheet of approved make & brand conforming to IS: 14443-1997 and having 50 micron UV protection layer under co-extrusion technology, Fire rating being B-s1 as per EN13501-1 certification, fitted and fixed with 60mm wide aluminium channel section top and bottom member in dry-glaze sandwitch system, (unit wt. of top and bottom members: 0.375 kg/m & 0.69 kg/m) of approved brand and profile, EPDM quality rubber gaskets, anti-dust tape, end closer \\"C\\" channel and 75 mm long Self tapping screw being drilled through the centre leg of the bottom section with nuts placed at 300 mm apart without anyway puncturing the polycarbonate sheet, EPDM Washer 16 mm dia. & 3 mm thick washer etc. complete strictly as per manufacturers specification and direction of Engineer-in-Charge. (Payment to be made on area of finished work). In Roof:- Natural/ Blue/ Green/ Bronze/ Opal/ Metallic grey colour With 2 wall 8 mm overall thickness (wt.1.50kg/sqm, Ugvalue being 3.3 W/m2K, Min. cold bending radius of 1200 mm). |
| 37 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapezoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self-tapping screw, EPDM Washer 16 mm dia. & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet. |
| 38 | Double acting Iron Spring Hinges of approved quality fitted and fixed complete: - (a) 100 mm size. |
| 39 | Anodised aluminium decorative handle (hexagonal / fluted) of approved quality fitted and fixed complete. (i) 150 mm plate x 10 mm dia rod x 12 mm hexagonal / fluted. |
| 40 | Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete. |
| 41 | Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete. Medium (I.S.I. size 2). |
| 42 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 225mm long x 10mm dia. bolt. |
| 43 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia. rod with centre bolt and round fitting. (a) 250mm long. |
| 44 | Door stopper.(Brass) |
| 45 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of concrete will be paid separately) 40mmX6 mm, length 250 mm. |
| 46 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100 x 50 x 1.25 mm. |
| 47 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well-seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. 35 mm thick shutters (single leaf). |
| 48 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps.(The quantum should be corrected upto three decimals). (i)Sal: Siliguri. |
| 49 | M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor. |
| 50 | Supplying best Indian Reinforced wire safety glass 6 mm thick including cutting to required sizes, setting on putty bases and fitted and fixed with teak glazing bead (19mm x 12mm) including putty and nails as necessary complete. (In all floors for internal wall & upto 6 m height for external wall). |
| 51 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. (i) Single Socketed 3 Meter Length (a) 110 mm. |
| 52 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. (i) Double Socketed 0.60 Meter Length (a) 110 mm. |
| 53 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground (i)110 mm dia. |
| 54 | UPVC Fittings: |
| 55 | a) Plain Tee 110 mm. Dia. |
| 56 | b) Bend 87.5 degree 110 mm. Dia. |
| 57 | c) Plain Y 110 mm. Dia. |
| 58 | d) Shoe 110 mm. Dia. |
| 59 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. |
| 60 | (i) Door Tee 110mm |
| 61 | (ii) Door Bend (TS) 110mm |
| 62 | (iii) Double Y with Door; 110 mm |
| 63 | (iv) Cross Tee with Door; 110 mm |
| 64 | (v) 110 X 110 P Trap 75 mm |
| 65 | (vi) Vent Cowl 110 mm |
| 66 | Supplying PVC rollers for sliding windows as per direction of Engineer in charge. |
| 67 | Removing chokage of H.C.I. or S.W. pipe with split bamboo Underground. |
| 68 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick). |
| 69 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer. |
| 70 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) Luxury Quality. Please Enable Macros to View BoQ information |