| 1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finishAverage run 8 mtr [ E-24/1(c) ] |
| 2 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.On Board [E- 24 / 3(a)] |
| 3 | Supply & Fixing of modular blanking Plate |
| 4 | SUB-HEAD 2 - PLUGS, SOCKETS & SWITCH BOARDSSupplying & fixing GI modular switch board of the following sizes complete with three nos. suitable size copper bar with holes (for ph. , N &E) fixed on bakelite / Hard rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 6 Module [E-17/1(b)] |
| 5 | 2 Row 12 Module [E-17/1(e)] |
| 6 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(a)] |
| 7 | Supply & Fixing 240 V 16 A Modular type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(b)] |
| 8 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu. wire and earth continuity wire etc. [E-17/4(a)] |
| 9 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu. wire and earth continuity wire etc. [E-17/4(b)] |
| 10 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire. [E-17/5(a)] |
| 11 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections [E-17/5(b)] |
| 12 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19/17] |
| 13 | SUB-HEAD 3 - HTPNDB, SPNDBSupplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ Schneider/ Crabtree) as per direction of EIC. )6 Way, Make - Legrand, Enclosure-(607716) / Schneider, Enclosure- (A9HTND06) / Crabtree, Enclosure - (DCDKTHODCW08) [D- 10 /14] |
| 14 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+12 Way, Make - Legrand (Enclosure - 607712), Siemens (Enclosure - 8GB32102RC14) [D- 9/13] |
| 15 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection (Make - Legrand / Siemens / Schneider ) 63 A FP [D- 5/6] |
| 16 | 40 A DP [D- 5/6] |
| 17 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS (Make-Legrand/Siemens/Schneider) as per direction of EIC. 6-32 SP [D-6/7] |
| 18 | SUB-HEAD 4 - Laying of polythene pipe & drawing of copper wireDistribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1(a) (i)] |
| 19 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1(a) (ii)] |
| 20 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [E-14/1(a) (iii)] |
| 21 | 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [E-14/1(a) (iv)] |
| 22 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works25mm size [E-16/7(b)] |
| 23 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [E-9/1(g1)] |
| 24 | 2.5 sq. mm. [F-5/9(i)] |
| 25 | 4 sq. mm. [F-5/9(ii)] |
| 26 | 6 sq. mm. [F-5/9(iii)] |
| 27 | 16 sq. mm. [F-5/9(v)] |
| 28 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire / strip armour for mechanical protection, and PVC / FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Non Schedule Item No. CABLE/ Page 1 / Item No. 1]4 core 25 sqmm [Non Schedule Item No. CABLE/ Page 1 / Item No. 1.12] |
| 29 | Laying of cable as below, after cutting floor / pavement / wall / and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbishFrom 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor / pavement / wall etc. [F- 3/5(i)] |
| 30 | SUB HEAD - 5 : Supply & Fixing of Light FittingsSupplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV (internal) with Short & Open circuit protection , THD < 10% , P.F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K / 6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark / Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt) [Non Schedule Item No. LED LIGHT/ Page 4 / Item No. 4]Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification [Non Schedule Item No. LED LIGHT/ Page 4 / Item No. 4.1.1] |
| 31 | S & F 18W LED Tube (Make - Philips, Cat no. - Essential LEDTube 1200mm 20W865 T8 IND I – 2100lm) or equivalent of Bajaj / CG / Magik. [NS] |
| 32 | Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) 2'x2' with powder-coated pressure Die-cast Aluminium / CRCA sheet body with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark / Name Engraved / Embossing/ Screen printing on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below: 3.1 System lumen efficacy ≥135 lm/Watt [Non Schedule Item No. LED LIGHT/ Page 3 / Item No. 3]33 - 36 Watt [Non Schedule Item No. LED LIGHT/ Page 3 / Item No. 3.1.3] |
| 33 | Supplying, installation, Testing & Commissioning of Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency > 80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.System lumen efficacy shall be as below: 7.1 System lumen efficacy ≥135 <135 lm/Watt [Non Schedule Item No. LED LIGHT/ Page 6 / Item No. 7]70 Watt [Non Schedule Item No. LED LIGHT/ Page 6 / Item No. 7.1.2] |
| 34 | S&F of 20 mm. dia. 14 SWG downrod [NS] |
| 35 | SUB-HEAD 6 - EarthingExcavation of soil for installation of Earth Electrode and filling & ramming.For Soft Soil [G-1/1(a)] |
| 36 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: [G-1/2(a)]By ISI-Medium GI pipe |
| 37 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [G-2/3(a)] |
| 38 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [G-2/4(a)] |
| 39 | Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS No. - 4 SWG [G-2/5(a)(i)] |
| 40 | Add GST @18%:- Rs |
| 41 | Add LWC @1% Rs. Please Enable Macros to View BoQ information |