| 1 | M &L for replacement of 33KV jumpers by DOG conductor at pole by new one, with PG clamp including nuts and bolts / connector for fixing / tightening two conductor of equal or unequal size as directed by Engr-in charge. |
| 2 | M &L for replacement of 11KV jumpers by Weasel conductor at pole by new one, with PG clamp including nuts and bolts / connector for fixing / tightening two conductor of equal or unequal size as directed by Engr-in charge. |
| 3 | Material & labour for Repair,Maitainance & Servicing of 11KV HT VCB indoor/outdoor type complete including the following (a) Taking out 11KV HT VCB of 400/630/800 Amp rating trolley from HT Panel after switching off electric supply. Removing all mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, remote operation, indication system, upward-downward/in-out movement of HT VCB trolley,etc including opening the VCB trolly & checking the quality of insulating material,vaccum system complete. Replace defective parts, fixed/ moving contacts and blowing out dust and applying the proper lubrication/ greasing with AP-3 grease and reassembling the VCB including connection to HT panel and make the VCB functional to the entire satisfaction of and as directed by the Engineer-in-charge. Notes :- (i) The VCBs are installed at CPH, Tech area, 33 SU Site 1A & SITE 1B and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc. |
| 4 | Material & labour for Repair and maitainance of 33 KV VCB outdoor type complete including the following (a) 33KV HT VCB of 1250 Amp rating HT Panel after switching off electric supply. Removing all mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, remote operation, indication system of HT VCB ,etc complete.Refixing with faulty part replaced, fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing with AP-3 grease and reassembling the VCB including connection to HT panel & and make the VCB functional to the entire satisfaction of and as directed by the Engineer-in-charge. Notes :- (i) The VCBs are installed at CPH, VCBs are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc. |
| 5 | Material & labour for Repair and maintanance of relay set (O/C and E/F relays) of any make for 11KV VCB/RMU panel, removing and refixing (the contacts NO+NC should be cleaned by CTC solution and adjust if electromagnetic) with faulty part replaced and calibrate the relays by relay testing kit & proper setting as per reqd load & time delay and fixing the relay set in HT panels and complete all as specified and directed by Engr-in-charge. Notes :- (i) Testing shall be carried out by primary and secondry injection kit. (ii) Spare parts shall be measured and paid separately under supply only. (iii) The tripping system should be in accordance with the incomer of the affected feeder and setting should be maintained such that fault does not carry beyond the particular feeder due to overload, 3 phase fault, earth fault etc.(iv) The VCBs/RMUs are installed at CPH, Tech area, 33 SU Site 1A & SITE 1B and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom,Schneider, Ashida, Siemens,L&T, C&S or any other of relays available on the site. |
| 6 | Material & labour for Repair and maintanance of 11 KV HT RMU indoor/outdoor type, EACH WAY of RMU 400/630/800 Amp rating from HT Panel after switching off electric supply. Removal of all the possible mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, indication system, including checking the quality of insulating material, complete & refixing with faulty part replaced blowing out dust and applying the proper lubrication/ greasing and reassembling the including motorised operation and connection to HT panel & filling of gas (if quantity is lesser than required) and make the RMU functional to the entire satisfaction and as directed by the Engineer-in-charge. Notes :- (i) The RMUs are installed at CPH, Tech area, 33 SU Site 1A & SITE 1B and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc. (ii) Spare parts if replaced & if Gas filled shall be measured and paid separately under supply only items. |
| 7 | Supply only SF6 gas suitable for HT33/11 KV RMU/VCB complete all as directed by Engr-in-charge. |
| 8 | Supply only trip/closing coil suitable for HT, VCB/RMU, operating on 24/110 volt system and testing complete all as directed by Engr-in-charge. |
| 9 | Supply only DC contactor operated on 110 / 24 volt system suitable for working of HT VCB/RMU complete all as directed by Engr-in-charge. |
| 10 | Supply only Motor cut off limit switch sutable for HT 11 KV VCB/RMU complete all as directed by Engr-in-charge. |
| 11 | Supply only Push Button element with one NO / NC complete all as directed by Engr-in-charge. |
| 12 | Supply only Spring charging handle suitable of VCB/RMU charging as per sample all as specified and directed by Engr-in-charge. |
| 13 | Supply only TNC switch with wiring suitable for 11 KV VCB complete all as directed by Engr-in-charge. |
| 14 | Supply & testing of spring charging mechanism with motor for outdoor/indoor type, 11KV, VCB/RMU,operated on 230/110/24 volts DC,with charging time less than 15 sec of approved rating complete all as specified and directed by Engr-in-Charge. |
| 15 | Supply and fix in repair multifunction meter with LCD display suitabale for measuring 11 KV electrical parameters( Voltage, Amp, power factor, frequcncy. Kwh, harmonics upto 31 level) complete all as specified and directed |
| 16 | Supply only Auxiliary switch 6 NO/6NC complete all as directed by Engr-in-charge. |
| 17 | HT 33KVA OUTDOOR TYPE CT & PTMaterial & Labour for removal of bushing & terminals and cleaning CT/PT 33 KV by CTC solution on its insulators and teeths and checking the leakage if any from the CT and refixing the same after replacing the defective/faulty parts and checking the oil level and oil dielectric strength (BD test) and proper connection checking/tightening of control wiring and testing with the following :- (i) Meggar testing between phase to phase & phase to earth.(ii) Testing the terminal connection and its working for the calibration and tripping of the relay for the protection of HT 33KV line.Make it functional to the entire satisfaction of and as directed by Enginer-in-charge |
| 18 | Supply & fixing in replacement indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed by Engr-in-charge. |
| 19 | Supply and fix in replacement of Power Pack for 11 KV VCB/RMU suitable for incoming supply 220/110 volts and output 110/24 volts DC supply all as per existing with wiring complete all as directed by Engr-in-Charge.Note : - The contractor has to visit the site to check the existing system of 11 KV VCB/RMU for installation of power pack unit. |
| 20 | Testing/Servicing of Transfromer 33/11 KV, up to 5 MVA Cleaing of power transformer 33/11 KV, outdoor type externally included all accessories (such as conservator tank, marshaling box, bushings, bucholz relay radiator, bushing,oil level indicator ) complete and checking the incoming and outgoing termianl connection complete with the following testing. (i) Transformer oil dielectric strength (BD voltage) test(ii) Buccholz realy alarm and trip testing (iii) Oil temperator alarm & trip testing (iv) winding tempreture alarm & trip testing (v) Meggar testing between HV to earth(vi) Meggar testing betweeen LV to earth)(vii) meggar testing between HV to LV(viii) earth resistenace test of transformer neutral.(ix) earth resistence test for body earthing |
| 21 | Dismantaling top cover of transformer of capacity upto 630 KVA , any make for repair / replacement of HT / LT bushing of transformer , or for replacement of top cover gasket or for inspection of transformer or for internal repairs of transformer all including draining transformer oil as required / upto the required level, re fitting the top cover of transformer after completion of the work including testing complete etc all as specified and directed.Note - spare parts will be measured and paid seperatelly |
| 22 | Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, by replacing gasket / seal , or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed. |
| 23 | M & L for replacement of defective silica gel breather with silica gel complete set upto 630KVA |
| 24 | M & L for replacement of LT bushing of brass with neoprene rubber bush for Transformer upto 630KVA capacities.all as directed by EIC |
| 25 | M & L for replacement of HT bushing of brass of transformer of any capacity upto 630 KVA.all as directed by EIC |
| 26 | Suply only Silica gel complete all as specified and directed by engineer -in- charge |
| 27 | Material, labour & T&P for Preparation of old painted iron surfaces of the transformer upto capacity 630 KVA, by cleaning / scrapping completely after that applying two coats of synthetic enamelled paint over a coat of primer on the transformer as per MES colour complete all as directed by Engr - In - Charge. Note : Painting shall be carried out with Spray Gun using compressor. |
| 28 | Supply & filling of transformer oil in site for toping up the level of oil having dielectric strength between 55-65 KV during filling after initial filtration of any capacity complete all as specified and directed by engineer -in- charge. |
| 29 | M & L for dehydration /filtration of transformer oil in existing pole mounted/floor mounted transformer/Voltage stabilizer with the help of dehydration/filtration machine to achieve the dielectric strength of transformer oil not less than 50 KV all as directed by EIC Note:- (i) Dehydration/filtration machine will be arrange by the contractor and he will make his own arrangement and to carry the machine at various sub stations including vehicle and towing arrangement. The rate shall be inclusive of all above. |
| 30 | Dismantling of cross arms / bracing supports / clamps / back plates or any other structural steel sections including removing nuts bolts washers etc |
| 31 | M & L for cross arms, bracing supports, clamps back plates angles fabricated from the structural steel section including bolts, nuts, washers, welding, bending, drilling holes for bolts, bent to any required shape of size as indicated or directed, inclusive of one rimer coat and two coats of aluminium paint after preparation of surfaces. |
| 32 | Dismantling & taking down, old, defective, weak insulator, any type, any size any shape (pin / shackle / loop ). |
| 33 | S & F pin type insulator porcelain vitreous white / brown / green including one galvanised mild steel spindle, two galvanised iron washers, one galvanised iron nut, suitable for 11000 volts grade & of size 150 mm dia and 150mm height. |
| 34 | S & F pin type insulator porcelain vitreous white / brown / green including one galvanised mild steel spindle, two galvanised iron washers, one galvanised iron nut, suitable for 33000 volts grade. |
| 35 | S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed. |
| 36 | S&F Disc type insulator, porcelain, vitreous, ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 33000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed. |
| 37 | Dismantling & taking down old, deteriorated, switch air break and supply and fixing switch air break gang operated triple pole mechanically operated horizontal/vertical type mounted on insulator & steel frame, with operating mechanism worked from ground level for current rating upto 200 Amps horizontal type suitable for 11000 V. grade all as specufied and directed. |
| 38 | Dismantling & taking down old, deteriorated, expulsion fuse assy and supply and fixing expulsion fuse single pole (drop out fuse) mounted on insulator & steel frame 100 Amps for 11000 V grade. |
| 39 | M&L for servicing and greasing of mechanical parts of existing 33/11KV horizontal/vertical type GOD including replacement of parts i.e Male/female contact, jumper ,operating mechanism, GOD rod etc specified and directed by Engr-in charge |
| 40 | Trimming/cutting the tree branches/ bushes around theHT over head line and making safe clearance up to 4.00 metre distance from line wire/panel all as directed by Engineer-in-Charge. ( Each Span = distance between two poles) |
| 41 | M&L of checking of HT 11/33KV cable of any size by means of HT Cable Fault Locator Machine by requisition for removal of HT cable faults complete all as specified and directed |
| 42 | Supply and fix in repair cable joint kit for 11 KV grade cable for indoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 to 120 sqmm complete all as specified and directed by the Engineer - in - Charge. |
| 43 | Supply and fix in repair cable joint kit for 33 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 300 sqmm complete all as specified and directed by the Engineer - in - Charge. |
| 44 | Supply and fix in repair cable joint kit for 11 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 to 120 sqmm complete all as specified and directed by the Engineer - in - Charge. |
| 45 | Supply and fix in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 sqmm complete including digging if required all as specified and directed by the Engineer - in - Charge. |
| 46 | Supply and fix in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185 sqmm complete including digging if required all as specified and directed by the Engineer - in - Charge. |
| 47 | Supply and fix in repair Cable joining kit for 33 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete including digging if required all as specified and directed by the Engineer - in - Charge. |
| 48 | Taking out old HT U/S cable of any size and any type as directed by Engr-in-charge. |
| 49 | Supply and fix in trench/wall / pole XLPE insulated PVC sheated armoured heavy duty HT electric cable with aluminium stranded conductor 11000 volt grade of sizes 95 Sqmm 3 Core complete all as specified and directed. |
| 50 | Supply and fix in trench/wall / pole XLPE insulated PVC sheathed armoured heavy duty HT electric cable with aluminium stranded conductor 33000 volt grade of sizes 300 Sqmm 3 Core complete all as specified and directed. |
| 51 | S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for overhead line on HT poles including jointing with and including aluminium binding wire 2 mm dia, jumpers, line tapes, conducting jelly, stretching properly and connecting with suitable PG clamps, etc including dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/type/capacity, complete all as specified and as directed.Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code. |
| 52 | Surface dressing/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms, two pole/ four pole structure surroundings to make a over all presentable condition all as directed by Eng In charge. |
| 53 | Supply and lay stone aggregate of size 40mm to 63mm graded layed on ground of yard/ two/four pole structure complete all as specified and directed. |
| 54 | M&L in repair of Earthing complete with copper earth plate electrode, 60x60cmx 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip of 30x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as per direction of Engr-in charge. |
| 55 | Material and labour copper strip as earth continuity conductor or main earthing lead of size 20 x 3 mm |
| 56 | M&L in repair for earthing complete with GI earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including GI earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m as directed. |
| 57 | Material and labour galvanised iron strip as earth continuity conductor or main earthing lead of size 32 x 6 mm |
| 58 | Material & labour for Painting of all 2 pole/ 4 pole structure according to MES colour coding such as pole, structures,angle, GO DO etc at Swicthyard complete all as specified and directed by engineer -in- charge |
| 59 | Material & labour for Repair and maintanance of relay set (O/C and E/F relays) of any make for 33KV VCB panel, removing and refixing (the contacts NO+NC should be cleaned by CTC solution and adjust if electromagnetic) with faulty part replaced and calibrate the relays by relay testing kit & proper setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by Engr-in-charge. Notes :- (i) Testing shall be carried out by primary and secondry injection kit. (ii) Spare parts shall be measured and paid separately under supply only. (iii) The tripping system should be in accordance with the incomer of the affected feeder and setting should be maintained such that fault does not carry beyond the particular feeder due to overload, 3 phase fault, earth fault etc.(iv) The VCBs/RMUs are installed at CPH, Tech area, 33 SU Site 1A & SITE 1B and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom,Schneider, Ashida, Siemens,L&T, C&S or any other of relays available on the site. |
| 60 | Material & labour for Repair,Manitenance of 11KV HT Capacitor bank outdoor/Indoor type complete including the following (a) Checking the serviceability by Meggaring of each capacitor unit of any capacity.(b) Replace defective minor parts ( thimble, wire connections, ..etc) and blowing out dust and including connection to HT panel and make the capacitor bank functional to the entire satisfaction of Engineer-in-charge. . |
| 61 | Material & labour for Repair,Maintenance of 11KV HT Potential Transformer complete including the following (a) Checking the serviceability by Meggaring of each PT unit of any capacity.(b) Replacement of defective parts i.e fuse of any capacity,connection wire etc and blowing out dust and including connection to HT panel and make the PT functional to the entire satisfaction of Engineer-in-charge. . |
| 62 | Supply, installation, testing and calibration of relay 110/24V of Microprocessor based three phase relay system to overcurrent, one earth fault protection type for 11 KV breaker, setting range suitable for over current and earth fault with necessary wiring/fitting including dismantling of old IDMT or unserviceable relays.The setting of the relay should be in accordance with the incomer and setting should be maintained such that fault does not carry beyond the affected feeder in case of Overload,3 phase fault, earth fault etc complete all as specified and directed by the Engineer-in-Charge. Note :- The calibration of relay of Microprocessor based three phase relay system required to carried out at CPH. Make C&S model no. CSENex-I 150 in equivalent Schenider, Siemens.(ii) The calibration of relay of Microprocessor based three phase relay system to be carried out by OEM representative. |
| 63 | Supply and fix in replacement of power factor improvement capacitor oil immersed three phase static 12 KV capacitor with manual control 50 KVAR complete will all insulation for terminals as directed by EIC. |
| 64 | Material & labour for two coat of Aluminium Painting MS angle of 5MVA Yard at CPH such as structures,angle, GO DO etc at Swicthyard complete all as specified and directed by engineer -in- charge |
| 65 | Material & labour for two coat of Aluminium Painting MS angle of 1MVA Yard at CPH such as structures,angle, GO DO etc at Swicthyard complete all as specified and directed by engineer -in- charge |
| 66 | Boring of holes under road, pavement, hard standing by manual method including 100mm of HDPE pipe complete all as specified and directed. |
| 67 | M&L cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia |
| 68 | Dismantling old pcc poles/struts, any size. |
| 69 | Supply and fix (in replacement of PCC pole) steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.0 metres long) |
| 70 | Supply and Fix in replacement Prestressed concrete pole 9.0 metres long, 102x172mm at top and 102x279mm at bottom, class 10 complete all as specified and directed. |
| 71 | Supply and fix in repairs for stay assembly as shown in electrical plate No 1 of SSR part I comprising of 7/3.15 mm galvanised mild steel stranded stay wire of required length fixed to pole with and including FI clamps of size 50x6 mm, bolts, nuts, washers, stay rod of 20 mm dia 2.15 mtrs long, stay bow with nuts bolts washers, galvanised steel plate 230x230x6 mm including loop insulators over all dimensions 90mmx140 mm cleearance of hole 25.5 mm complete including taking down old unserviceable stay assembly all as specified and directed. |
| 72 | M & L in repairs lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 volts. |
| 73 | Supply and fix in repairs HT cable mild steel route marker with angle of size 35mmx35mmx5mm and 600 mm long all as specified and as directed. Note :- Earth work and PCC work shall be measured and paid separately. |
| 74 | Re-stringing and stretching of OH line of ACSR 33/11 KV rating conductor on 11m height steel tubular pole including pruning of tree branches and cleaning of insulators and aluminium wire within the span of 60m for binding all as directed.Note : One RM s\span is measured for one RM span of 3 Nos conductors. |
| 75 | S&F PVC sleeves (Red/Yellow/Blue) for jumper connections and connector on poles at sub stations complete all as specified and directed. |
| 76 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 77 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil speciallu for LT pole stay assembly complete all as specified and directed. |
| 78 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft / hard dense soil complete all as specified and directed. |
| 79 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed. |
| 80 | M&L Sand cusioning of tibba sand for XLPE cable with screened & washed sand & punning to provide a required cover complete all as specified and directed. |
| 81 | Supplying and laying reinforced precast concrete cable cover, Class HVP, Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 82 | Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 83 | Labour only for retrived stone patty from excavation complete all as specified and directed. |
| 84 | M&L for cement concrete 1:3:6 type C2 using 40 mm graded as in foundation filling and mass concrete complete all as specified. |
| 85 | M&L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) for coping including form work etc complete all as specified and directed. |
| 86 | Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed. |
| 87 | Disconnect of Electric supply , GI / Copper strip and taking down distribution transformer carefully lifting by crane . Transporting the transformer safely to the workshop and back for repair . Re- install , re - connect of electric supply , GI / Copper strip and testing on load all as specified and as directed for the following capacity of transformers . (a) Capacity 200 KVA to 400 KVA |
| 88 | (b) Capacity 50 KVA to 150 KVA |
| 89 | (C) Capacity 500 KVA to 1000 KVA |
| 90 | Opening the top of the Distribution transformer 11KV/430 Volts, draining out transformer oil, cleaning the internal portion of tank, core and connections by mechanical means and force feeding of transformer oil and flushing out deposits, sludge etc, and closing the top complete all as specified and directed for the following capacity of transformers:-(a) Capacity 200 KVA to 400 KVA |
| 91 | (a) Capacity 50 KVA to 150 KVA |
| 92 | (b) Capacity 500 KVA to 1000 KVA |
| 93 | Material and labour for Rewinding of transformer Step up / down , HV Coils complete with existing size/ electrolytic copper conductor design with TPL covering, re-assembling of newly wounded coils on core in position including re- insulation oven baking and testing complete all as specified & directed for the 50-1000KVA transformers |
| 94 | Material and labour for Rewinding of transformer Step up / down , LV Coils complete with existing size/ electrolytic copper conductor design with TPL covering, re-assembling of newly wounded coils on core in position including re- insulation and testing complete all as specified & directed for the 50-1000KVA transformers . |
| 95 | Material and labour for replacement of unserviceable gaskets with Neoprene sheet 6 mm thick, nut bolts washers complete all as specified and directed. |
| 96 | Material and Labour for replacement of HT bushings with brass rod of size suitable for following capacity Transformer, including cork sheet gaskets, complete all as specified and directed for the following capacity of transformer :-(a) Capacity 200 KVA to 400 KVA |
| 97 | (b) Capacity 50 KVA to 150 KVA |
| 98 | (C) Capacity 500 KVA to 1000 KVA |
| 99 | Material and Labour for replacement of LT bushings with brass rod of size suitable for following capacity Transformer, including cork sheet gaskets, complete all as specified and directed for the following capacity of transformer :-(a) Capacity 200 KVA to 400 KVA |
| 100 | (b) Capacity 50 KVA to 150 KVA |
| 101 | (c) Capacity 500 KVA to 1000 KVA Please Enable Macros to View BoQ information |
| 102 | (c) Capacity 500 KVA to 1000 KVA Please Enable Macros to View BoQ information |