| 1 | Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete including taking out old u/s wiring. |
| 2 | All as per item No 01 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke & Halogen, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch including taking out old u/s wiring. |
| 3 | Supply and fix in repairs/replacement of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V. |
| 4 | Supply and fix in repairs/replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth. |
| 5 | Supply and fix in repairs flame proof and weather proof metal clad single pole and neutral with earth enclosure industrial plug and socket with suitable size of flame proof MCB SP 6 to 32 Amps C type, in aluminum alloy LM 6 Construction, certified by CMRS, Dhanbad for Group I, IIA, IIB, including necessary connection complete all as specified and directed. |
| 6 | Supply and fix in repairs flame proof and weather proof metal clad triple pole and earth enclosure industrial plug and socket with suitable size of flame proof MCB triple pole 32 Amps C, in aluminum alloy LM 6 Construction, certified by CMRS, Dhanbad for Group I, IIA, IIB, including necessary connection complete all as specified and directed. |
| 7 | S&F in repairs/replacement of flame proof weather proof flood light fitting suitable for & including 90 watt LED chips, in cast aluminum alloy LM 79 construction, including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed. |
| 8 | S&F in repairs/replacement of flame proof weather proof flood light fitting suitable for & including 70 watt LED chips, in cast aluminum alloy LM 79 construction, including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed. |
| 9 | S&F in repairs/replacement of flame proof weather proof flood light fitting suitable for & including 45 watt LED chips, in cast aluminium alloy LM 79 construction, including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete. |
| 10 | S&F in repairs/replacement of flameproof, weather proof LED tube light fitting, type FLP-WP with LED 1 x 16 / 20 W including integral reflector made of aluminum alloy LM79 , with electronic driver, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed. |
| 11 | S&F in repairs/replacement of flameproof, weather proof LED tube light fitting, type FLP-WP with LED 2 x 16 / 20 W including integral reflector made of aluminum alloy LM79 , with electronic driver, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed.Note For Item No 7 to 11:-1. All Flameproof LED light procured by the contractor shall pre tested in accordance with LM 79 by manufacturers for individual Flameproof LED products, in their own laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) or UL or third party laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL). Contractor shall submit documentary evidence obtained from manufacturer of LED light fitting that laboratory in which testing has been carried is accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) along with sample of LED fitting all as specified under relevent PS clause. |
| 12 | Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and in existing mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete.Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 13 | Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and in existing mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete.Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 14 | Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and in exitsting mild steel ERW conduit class 'B' (ISI Makes) not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete.Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 15 | Material & Labour in repair for sub main wiring with 4 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Makes) not less than 32 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete.Note: 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 16 | Material & Labour in repair for sub main wiring with 4 run single core multistranded copper conductor cable of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Makes) not less than 32 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete.Note: 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 17 | Supply and fix MCB’s single pole, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. |
| 18 | Supply and fix MCB’s single pole & neutral, 32to 40 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. |
| 19 | Supply and fix MCB’s triple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. |
| 20 | Supply and fix in repair weather proof & flame proof PVC knob suitable for flame proof DBs/Flame proof Switch rotary complete all as specified and directed. |
| 21 | Supply & laying IN REPLACEMENT OF PVC inner sheathed, armoured cable, with copper conductor 1100 volt grade of size 1.5 Sqmm 3 core fixed on wall/ duct passing through pipe / duct and connecting and testing etc complete all as specified & directed |
| 22 | Supply & laying IN REPLACEMENT OF PVC inner sheathed, armoured cable, with copper conductor 1100 volt grade of size 2.5 Sqmm 3 core fixed on wall/ duct passing through pipe / duct and connecting and testing etc complete all as specified & directed |
| 23 | Supply and fixing in repair of flexible steel conduit 20/25mm dia ISI marked on ceiling or recessed as required & repairing & making good the same disturbed surfaces all as specified and directed |
| 24 | Supply and fixing in repair of stove enamelled black MS conduit 25mm dia ISI marked fixed on pole /wall or as required & repairing & making good the same disturbed surfaces all as specified and directed |
| 25 | Supply and fixing in repair of stove enamelled black MS conduit 32mm dia ISI marked fixed on pole /wall or as required & repairing & making good the same disturbed surfaces all as specified and directed |
| 26 | Supply and fixing in repair of led tube rod 18/20 W to be fixed in existing flameproof fitting including opening of fitting connection of wire etc and all electrical connection required to make light serviceable and refixing of fiiting at exisiting position or as directed by Engineer in charge |
| 27 | S&F in repairs/replacement of LED flood Light fitting 120 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete. |
| 28 | S&F in repairs/replacement of LED flood Light fitting 200 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete. |
| 29 | S&F in repairs/replacement of LED flood Light fitting 250 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete. |
| 30 | Supply and fixing of LED high bay light fitting 150 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete. |
| 31 | Supply and fixing MCCB triple pole and neutral , DPX3 thermal magnetic capacity of 100 Amps,415 V and 16KA Short Circuit Breaking Capacity. |
| 32 | Supply and fix in repair of Single pole and neutral enclosure with a two pin and earthplug and socket complete with one double pole MCB 20amp c curve |
| 33 | Supply and fix in repair of Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp C Curve |
| 34 | S&F in replacement of LED Aviation obstruction light fitting die cast aluminium alloy housing, heat resistant, clear thick glass and accessories with LED lamp & driver, fixed in position & connecting complete |
| 35 | Supply & fixing in repair of sheet metal enclosures for fixing MCBs Single pole and neutral 8 way, 240 volts with 200 Amps rated bus bar withe double door fixed on flush to the wall including making the hole in the wall and fixing thee DB including cement work and plastering complete all as directed. |
| 36 | M&L for Reparing,alignment, servicing and cleaning of flame prof DB any size including incoming and outgoing MCB knob arrangement with all required accessory or directed by Engr-in-charge.Note- Cost of knob shall be paid seperatly as per respective item.Note for Item No 1 to 37:-(a)-One electrician and one helper should be available for attending day to day complaints on all days including/Sunday and holiday and rectified with in 24/48 hours, failing which an amount of Rs 200 /- per hour will be recovered as penalrecovery fromany payment due to the contractor after expiry of 48 hours.) (b) Indls should be in possession of all required tools for rectification of complaints . (c) Labour charges and cost of reqired tools and plant and safety PPE is deemed to be included in the rate above quoted. Please Enable Macros to View BoQ information |