| 1 | Note: Please refer Schedule 'A' Notes given on serial page No. 14 to 16 of tender documents. |
| 2 | B/R WORKS |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 4 | Taking down cement plaster on brick, concrete or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. of any description complete all as specified and directed |
| 5 | Material and labour for 5mm thick cement plaster in cement mortar 1:3 as on ceiling, soffits of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 6 | Material and labour for rendering 15 mm thick on wall in cement mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth, without using extra cement complete all as specified and directed. |
| 7 | Material and labour for 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 8 | Material and labour for preparation of new plastered surfaces of wall and applying two coats of oil emulsion over a coat of primer emulsion paint complete all as specified and directed. |
| 9 | Material and labour for preparation of newly plastered surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed. |
| 10 | Material and labour for preparation of old decorated/treated surface of walls including removing existing treatment by rubbing, scrapping, washing and applying two coats of oil emulsion over a coat of primer complete all as specified |
| 11 | Material and labour for preparation of old decorated/treated surface of ceiling including removing existing treatment by rubbing, scrapping, washing and applying two coats of oil emulsion over a coat of primer complete all as specified and directed. |
| 12 | Material and labour for Makrana white Marble work 18mm to 20 mm thick (table rubbed and polished) in steps, jambs, pillars window cills, cooking platforms , stair case and like with bull nosing in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade , directed and approved complete all as specified and directed. |
| 13 | Demolition of cement concrete in ground floor & paving n.exc 15cm above ground level complete all as specified and directed. |
| 14 | Material and labour for cement concrete (1:4:8) type D-2 using graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 15 | Material and labour for RCC M-25 (Design Mix) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete with, complete all as specified and directed. |
| 16 | Supply and fixing 10mm dia and over TMT bar cut to length bent to shape including cranking binding spirally, hooping, hooking end and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | M&L for formwork to rough finished flat surfaces of concrete foundations, footings, bases of coulmns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams; and other similar works; vertica or to batter complete all as specified and directed. |
| 18 | Material and labour for TMT bars 5 mm to 10 mm dia cut as in stirrups to length bent to shape required including cranking spirally for hooking ends and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified |
| 19 | E/M WORKS |
| 20 | Design, Supply, installation, testing and commissioning of 10 passengers cum stretcher lift, Gearless, machine room less (MRL) to serve G+3 upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, simplex full collective controlled operation, Telescopic side opening stainless steel doors with power drive, Automatic Rescue device system and 3 way intercom system & infrared curtain sensor, with all the items all as specified herein under:- (i) Type and capacity of Lift : Traction type, 10 Passengers Cum stretcher Lift (680 kgs)(ii) Speed : 1.0 m/sec(iii) Type of Drive : AC variable voltage & variable frequency or VVVVF drive or varable frequency (VF) as per OEM recommendations(iv) Machine room Less type(v) Travel - 12.0 Mtrs (Approx) or as per actual site measurement(vi) Serving : Ground floor to 3rd Floor ( Floor designations will be G/0,1,2,3)(vii) No of stops : 4(viii) Power supply: 415 Volts, 3 phase, AC, 50 Hz(ix) Shaft dimensions : 2280 mm width and 3000mm depth (approx)(x) Min Car size (inside) : 1200mm wide x 1400 deep x 2200 mm high(xi) Door dimensions : 800mm wide x 2000mm high (min.)(xii) Pit depth : 1600 mm (approx)(xiii) Over Head height : 4500mm (approx)(xiv) Car enclosure : Single entrance CarCar panels : AISI 441 Stainless steel hairline finish panels (all sides) with stainless steel hairline finish hand rail on back/rear wall as per OEM recommendationsCar ceiling : AISI 441 Stainless Steel hairline finish ceiling with axial fan. Car Flooring : Aluminium Chequered plate with min thickness 5mm Car Doors : Centre opening auto power doors in AISI 441 satainleass steel hairline finish.. The direction of the door opening should be as per space availability at site. |
| 21 | Skirting material : Stainless steel hairline Car illumination : Round LED lights - 04 Nos (xv) Front opening at at all landings(xvi) Door sfety: Full height infra red curtain sensor.(xvii) Landing Door/ Entrance: Telescopic side opening auto power doors in AISI 441 stainless steel hairline finish with 2 Hr fire rating for landing at all floors.(xviii) Control : Simplex Full collective (xix) Indicators: Car & landings: Direction and position indicator. (xx) Full height Car operating panel : Silver Brushed Stainless steel AISI 304 flush type with segmented LCD display with surface mounted Braille buttons. (xxi) Landing operating panel: Silver Brushed Stainless steel AISI 304 Flush mounted Simplex with with DOT Matrix display with surface mounted Braille buttons (xxii) Any type of structural steel required in shaft, bearing plate, load beam, necessary buffer, hanging hook and support channel (xxiii) Required trailing cable, Suspension Traction media, belt/ steel wire rope as per OEM recommendations etc. ADDL FEATURES :(a) Direction and position indicator in COP & LOP (b) Emergency alarm.(c) Three way intercom with hand free operation for car(d) Attendant key switch for COP(e) Fireman switch at main lobby(f) Emergency light with rechargeable battery and connected equipmet for charging (g) Adjustable guide shoes (h) Lift announcer (i) Accurate levelling, automatic closed door(j) Load weighing device with overload warning(k) Automatic phase sequence corrector & single phasing protection, under voltage and over voltage protection |
| 22 | (l) Manual rescue Operation (m) Automatic (Emergency) rescue device/automatic landing device with audio announcer to be operated with maintenance free batteries for safe landing as specified. (n) Other Equipments, accessories, safety devices required as per recommendation of OEM (o) Auto On/Off light/fan modeNotes: (i) The Lifts shall be installed by the original equipment manufacturer only. (ii) The lift shall be tested by IEM at the time of installation in the attendence of Manufacturer. (iii) The designing of the lift shall be as per existing lift shaft. The lift shall be installed as replacment in existing lift shaft. Please Enable Macros to View BoQ information |
| 23 | (l) Manual rescue Operation (m) Automatic (Emergency) rescue device/automatic landing device with audio announcer to be operated with maintenance free batteries for safe landing as specified. (n) Other Equipments, accessories, safety devices required as per recommendation of OEM (o) Auto On/Off light/fan modeNotes: (i) The Lifts shall be installed by the original equipment manufacturer only. (ii) The lift shall be tested by IEM at the time of installation in the attendence of Manufacturer. (iii) The designing of the lift shall be as per existing lift shaft. The lift shall be installed as replacment in existing lift shaft. Please Enable Macros to View BoQ information |