| Sl. No. | Item Title | Item Description |
| 1 | Wall painting for inside wall (three coats) with birla putty and plastic emulsion paint of approved brand & manufacture on undercoated wall surface to give an even shade including thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.And remove existing color work. etc complete all as directed by Engineer-in-Charge. | Wall painting for inside wall (three coats) with birla putty and plastic emulsion paint of approved brand & manufacture on undercoated wall surface to give an even shade including thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.And remove existing color work. etc complete all as directed by Engineer-in-Charge. |
| 2 | Finishing wall with Weather Proof Exterior paint on wall surfaces (three coats) to give an approved brand and manufacturer & required shape even shade after thoroughly brushing the surface to remove all dirt & remains of loose Powdered materials. Rate Shall Includes All tools and tackels, Scaffolding, material, laboure, machineart with taking care of all necessary safety protection PPE, scaffolding, Underpinning, etc. Complete in all manner. (Make and colour shead as Approved by Engineer-In-Charge) | Finishing wall with Weather Proof Exterior paint on wall surfaces (three coats) to give an approved brand and manufacturer & required shape even shade after thoroughly brushing the surface to remove all dirt & remains of loose Powdered materials. Rate Shall Includes All tools and tackels, Scaffolding, material, laboure, machineart with taking care of all necessary safety protection PPE, scaffolding, Underpinning, etc. Complete in all manner. (Make and colour shead as Approved by Engineer-In-Charge) |
| 3 | Providing and applying of External Texture on any height. make and pattern as approved Consultants/Client. Texture should be 2.0 to 2.5 mm thk layer with crack bridging up to 2.6 mm give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials. The texture material shell be pure acrylic, Environment Friendly, Protect against salt and carbon dioxide UV resistance, Moisture vapor transmission coating with third party test certificate applied up to 140 microns DFT. etc. required scaffolding, jhulaa, tools and labor. complete | Providing and applying of External Texture on any height. make and pattern as approved Consultants/Client. Texture should be 2.0 to 2.5 mm thk layer with crack bridging up to 2.6 mm give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials. The texture material shell be pure acrylic, Environment Friendly, Protect against salt and carbon dioxide UV resistance, Moisture vapor transmission coating with third party test certificate applied up to 140 microns DFT. etc. required scaffolding, jhulaa, tools and labor. complete |
| 4 | Aluminium window / Ventilation/Door Providing and fixing extruded aluminium window/Ventilation/Door having extruded aluminium Anodized section frame built up standard tubular and other section of approved make confirming to IS 733 and IS 1285, casement type window shutter of horizontal member, vertical member Confirming to IS733 and IS 1285 fixed with rawl plug abd screws or fixing clips,or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/Neoprene felt, glass of approved make etc. Aluminum sections shall be smooth, rust free, straight. mitred and jointed mechanically wherever required including hardware such as Friction stay,cleat angles aluminum snap beading for glazing/paneling, CP Brass/Stainless steel screws, Stoppers, S.S. Hinges, aldrop, Locking system and fixtures and transparent silicon sealant glass fixing to frame as per details all complete as per architectural drawings and the direction of Engineer in Charge. rate incl. all type of alumnium sections for, windows and Vents with 8/10/12 mm thick Toughened glass as per the detail Architectural dwg. | Aluminium window / Ventilation/Door Providing and fixing extruded aluminium window/Ventilation/Door having extruded aluminium Anodized section frame built up standard tubular and other section of approved make confirming to IS 733 and IS 1285, casement type window shutter of horizontal member, vertical member Confirming to IS733 and IS 1285 fixed with rawl plug abd screws or fixing clips,or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/Neoprene felt, glass of approved make etc. Aluminum sections shall be smooth, rust free, straight. mitred and jointed mechanically wherever required including hardware such as Friction stay,cleat angles aluminum snap beading for glazing/paneling, CP Brass/Stainless steel screws, Stoppers, S.S. Hinges, aldrop, Locking system and fixtures and transparent silicon sealant glass fixing to frame as per details all complete as per architectural drawings and the direction of Engineer in Charge. rate incl. all type of alumnium sections for, windows and Vents with 8/10/12 mm thick Toughened glass as per the detail Architectural dwg. |
| 5 | Providing & fixing 40mm thick fire rated acoustic door shutter manufactured as per approved standards, having hardwood/engineered wood perimeter frame with fire resistant and acoustic insulated solid core infill, finished with approved laminate/veneer on both sides, including intumescent fire seal, acoustic gasket, automatic bottom drop seal, SS hinges, fire rated mortise lock, handle, door closer and necessary hardware complete. The door shall be fixed with approved fire rated frame including all accessories, fitting, fixing and making good complete as per approved drawings and direction of Engineer-in-charge.Rate shall include shutter, frame, fire/acoustic seals, hardware, installation and certification complete. | Providing & fixing 40mm thick fire rated acoustic door shutter manufactured as per approved standards, having hardwood/engineered wood perimeter frame with fire resistant and acoustic insulated solid core infill, finished with approved laminate/veneer on both sides, including intumescent fire seal, acoustic gasket, automatic bottom drop seal, SS hinges, fire rated mortise lock, handle, door closer and necessary hardware complete. The door shall be fixed with approved fire rated frame including all accessories, fitting, fixing and making good complete as per approved drawings and direction of Engineer-in-charge.Rate shall include shutter, frame, fire/acoustic seals, hardware, installation and certification complete. |
| 6 | Supply, installation, testing and commissioning of Biometric Door Access Control Terminal with Face Recognition, Fingerprint, RFID Card and PIN authentication. Device shall support minimum 3,000 users, 3,000 fingerprints, 5,000 RFID cards and 100,000 transaction records. Identification time shall be less than 1 second. The terminal shall have TCP/IP and USB communication interfaces, inbuilt access control functions, door lock control, exit switch input, door sensor input and alarm output. Complete with mounting accessories, power supply, software, cabling, configuration and integration for proper operation as required.complete as per approved drawings and direction of Engineer-in-charge. | Supply, installation, testing and commissioning of Biometric Door Access Control Terminal with Face Recognition, Fingerprint, RFID Card and PIN authentication. Device shall support minimum 3,000 users, 3,000 fingerprints, 5,000 RFID cards and 100,000 transaction records. Identification time shall be less than 1 second. The terminal shall have TCP/IP and USB communication interfaces, inbuilt access control functions, door lock control, exit switch input, door sensor input and alarm output. Complete with mounting accessories, power supply, software, cabling, configuration and integration for proper operation as required.complete as per approved drawings and direction of Engineer-in-charge. |
| 7 | Repairing existing wooden stageProviding all materials and labour for repairing existing wooden stage, including dismantling and removing damaged wooden planks, plywood, battens and supporting members, supplying and fixing new approved quality hardwood/plywood members of matching size and thickness, Laminate,Stage legs,beading pattion,nails, screws, fasteners, necessary strengthening of framework, surface preparation, sanding, application of wood preservative and paint/polish finish, disposal of debris, and all tools, tackles, scaffolding and incidental works complete as directed by the Engineer-in-Charge. | Repairing existing wooden stageProviding all materials and labour for repairing existing wooden stage, including dismantling and removing damaged wooden planks, plywood, battens and supporting members, supplying and fixing new approved quality hardwood/plywood members of matching size and thickness, Laminate,Stage legs,beading pattion,nails, screws, fasteners, necessary strengthening of framework, surface preparation, sanding, application of wood preservative and paint/polish finish, disposal of debris, and all tools, tackles, scaffolding and incidental works complete as directed by the Engineer-in-Charge. |
| 8 | Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil etc complete all as directed by Engineer-in-Charge. | Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil etc complete all as directed by Engineer-in-Charge. |
| 9 | Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil etc complete all as directed by Engineer-in-Charge. | Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil etc complete all as directed by Engineer-in-Charge. |
| 10 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. etc complete all as directed by Engineer-in-Charge. | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. etc complete all as directed by Engineer-in-Charge. |
| 11 | Filling in foundation and plinth with murrumor selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete. | Filling in foundation and plinth with murrumor selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete. |
| 12 | Providing and laying in position Ready Mixed M- 150 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) | Providing and laying in position Ready Mixed M- 150 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) |
| 13 | Providing and laying in position Ready Mixed M- 250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg ) | Providing and laying in position Ready Mixed M- 250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg ) |
| 14 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling for any height any level. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns,Raft,RCC wall,Beam,Column etc. and Mass concrete.etc complete all as directed by Engineer-in-Charge. | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling for any height any level. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns,Raft,RCC wall,Beam,Column etc. and Mass concrete.etc complete all as directed by Engineer-in-Charge. |
| 15 | Providing TMT Bar FE 550D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level etc complete all as directed by Engineer-in-Charge. | Providing TMT Bar FE 550D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level etc complete all as directed by Engineer-in-Charge. |
| 16 | Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes up to 125 mm dia & upto 300 mm thickness machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. | Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes up to 125 mm dia & upto 300 mm thickness machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. |
| 17 | Brick work using common burnt clay building bricks having crushing strength not less than 35 kg/Sq. Cm. in foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand) Up to Plinth. (B) Conventional (more than 10 ton) etc complete all as directed by Engineer-in-Charge. | Brick work using common burnt clay building bricks having crushing strength not less than 35 kg/Sq. Cm. in foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand) Up to Plinth. (B) Conventional (more than 10 ton) etc complete all as directed by Engineer-in-Charge. |
| 18 | Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure above plinth level upto floor two level in cement mortar 1:5 ( 1 cement : 5 fine sand ) complete as per Technical Specification etc complete all as directed by Engineer-in-Charge. | Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure above plinth level upto floor two level in cement mortar 1:5 ( 1 cement : 5 fine sand ) complete as per Technical Specification etc complete all as directed by Engineer-in-Charge. |
| 19 | Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) etc complete all as directed by Engineer-in-Charge. | Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) etc complete all as directed by Engineer-in-Charge. |
| 20 | 10mm th cement plaster in single coat on fair side of brick / concrete wall for interior plastering upto floor two level finished even and smooth in C M 1:3 ( 1 cement 4 coarse sand) including floating coat of neat cement including finishing etc complete. | 10mm th cement plaster in single coat on fair side of brick / concrete wall for interior plastering upto floor two level finished even and smooth in C M 1:3 ( 1 cement 4 coarse sand) including floating coat of neat cement including finishing etc complete. |
| 21 | Providing 20 mm thick double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including scaffolding curing etc. complete. | Providing 20 mm thick double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including scaffolding curing etc. complete. |
| 22 | IRON WORKS - Providing, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using all type of rolled section, hollow/ tubular section, sheet, threaded J bolts, insert plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, spiral stairs, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, false ceiling frame work, Roof canopy, fencing posts, Screen & fencing jali frame work, puddle sleeve and flange etc. including straightening, cutting, bending, bolting and welding the members all as per structural drawings and as per detailed specifications.The rate shall include dry sanding, degreasing (wet cleaning) & preparation of rustfree surface of all dirt, dust and other foreign matter manually or echanically, 2 coat zinc chromate yellow oxide primer and 2 coat of enamel paint of approved shade of paint over all the surfaces of the steel sections or as specified in the drawing. The contractor shall be submit fabrication drawings based on construction drawings (that may be issued during construction period) for approval by the Architect/ Engineer. The fabrication work shall start only after approval of the fabrication drawings submited by contractor. Any change required in the fabrication drawings shall be carried out at No extra cost. Fabrication shall be in a perfect architectural workmanship manner .all complete as per drawing and directed by engineer in charge. | IRON WORKS - Providing, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using all type of rolled section, hollow/ tubular section, sheet, threaded J bolts, insert plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, spiral stairs, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, false ceiling frame work, Roof canopy, fencing posts, Screen & fencing jali frame work, puddle sleeve and flange etc. including straightening, cutting, bending, bolting and welding the members all as per structural drawings and as per detailed specifications.The rate shall include dry sanding, degreasing (wet cleaning) & preparation of rustfree surface of all dirt, dust and other foreign matter manually or echanically, 2 coat zinc chromate yellow oxide primer and 2 coat of enamel paint of approved shade of paint over all the surfaces of the steel sections or as specified in the drawing. The contractor shall be submit fabrication drawings based on construction drawings (that may be issued during construction period) for approval by the Architect/ Engineer. The fabrication work shall start only after approval of the fabrication drawings submited by contractor. Any change required in the fabrication drawings shall be carried out at No extra cost. Fabrication shall be in a perfect architectural workmanship manner .all complete as per drawing and directed by engineer in charge. |
| 23 | Providing and fixing in position S.S. railing(considering 1mt. height )by providing vertical support of 38 mm dia. pipe on top 50 mm dia stain less steel pipe rail with starting and end point vertical post of 50 mm dia with round ball on top of post including bending welding and fixing in R.C.C./brick work as directed.(top 50 dia vertical 38mm dia at 1 mt. c/c & horizontal 3 nos 25mm dia.).(testing is required of s.s 304) etc complete all as directed by Engineer-in-Charge. | Providing and fixing in position S.S. railing(considering 1mt. height )by providing vertical support of 38 mm dia. pipe on top 50 mm dia stain less steel pipe rail with starting and end point vertical post of 50 mm dia with round ball on top of post including bending welding and fixing in R.C.C./brick work as directed.(top 50 dia vertical 38mm dia at 1 mt. c/c & horizontal 3 nos 25mm dia.).(testing is required of s.s 304) etc complete all as directed by Engineer-in-Charge. |
| 24 | P & L 24\\" x 24\\" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskit etc complete all as directed by Engineer-in-Charge. | P & L 24\\" x 24\\" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskit etc complete all as directed by Engineer-in-Charge. |
| 25 | Providing and laying polished granite stone slab 18mm thick in risers of steps, dedo, jamb and pllars laid on 10mm thick cement mortar 1:3(1- cement : 3-coarsed sand) and jointed with gray cement slurry including rubbing,half moulding,semi-mirror polishing, mirror polish & polishing etc complete all as directed by Engineer-in-Charge. | Providing and laying polished granite stone slab 18mm thick in risers of steps, dedo, jamb and pllars laid on 10mm thick cement mortar 1:3(1- cement : 3-coarsed sand) and jointed with gray cement slurry including rubbing,half moulding,semi-mirror polishing, mirror polish & polishing etc complete all as directed by Engineer-in-Charge. |
| 26 | Providing and Laying Granite Flooring,ramp strips 18-20 mm thick one side polished flooring over 20mm (average) base of cement mortar 1:6 (1cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing, curing, semi-mirror polishing, mirror polish. complete as directed by Consultant / Engineer -in-charge. | Providing and Laying Granite Flooring,ramp strips 18-20 mm thick one side polished flooring over 20mm (average) base of cement mortar 1:6 (1cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing, curing, semi-mirror polishing, mirror polish. complete as directed by Consultant / Engineer -in-charge. |
| 27 | Providing & fixing 8mm thick rubber mat flooring of approved make, colour and pattern, laid over prepared sub-base using recommended adhesive, including cutting, fitting, edge trimming, finishing, all labour, materials, tools & tackles complete as per manufacturer specifications and direction of Engineer-in-Charge | Providing & fixing 8mm thick rubber mat flooring of approved make, colour and pattern, laid over prepared sub-base using recommended adhesive, including cutting, fitting, edge trimming, finishing, all labour, materials, tools & tackles complete as per manufacturer specifications and direction of Engineer-in-Charge |
| 28 | Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick. all complete as per the directions of Engineer In charge. | Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick. all complete as per the directions of Engineer In charge. |
| 29 | Providing and fixing 3 mm thick PVC sheets as Signage and Display of health signs/information of required size having retro reflective letters/design as per requirement, fixing the same through approved adhesive etc. complete work shall carried out as per instruction of Engineer-in-charge. | Providing and fixing 3 mm thick PVC sheets as Signage and Display of health signs/information of required size having retro reflective letters/design as per requirement, fixing the same through approved adhesive etc. complete work shall carried out as per instruction of Engineer-in-charge. |
| 30 | Medium back chair Providing & supplying Medium back chair as per selection. This item to the satisfaction of the engineer-in charge and consultant. complete as per instruction as directed by site in-charge or architect. | Medium back chair Providing & supplying Medium back chair as per selection. This item to the satisfaction of the engineer-in charge and consultant. complete as per instruction as directed by site in-charge or architect. |
| 31 | Providing and supplying hospital Ambulance Stretcher , suitable for ambulance and emergency medical services (EMS), having sturdy and durable frame, smooth loading and unloading mechanism, easy-to-operate adjustable design, safe patient transfer system, complete with all standard accessories, testing, packing, transportation, loading-unloading and commissioning as directed by Engineer-in-Charge. | Providing and supplying hospital Ambulance Stretcher , suitable for ambulance and emergency medical services (EMS), having sturdy and durable frame, smooth loading and unloading mechanism, easy-to-operate adjustable design, safe patient transfer system, complete with all standard accessories, testing, packing, transportation, loading-unloading and commissioning as directed by Engineer-in-Charge. |
| 32 | Linear Workstation/counter (Size: 800mm Wide x 750 Height) Providing and fixing Cluster (Linear Workstation) as per drawing, Framing the skeleton with 18mm+18mm = 36mm thick vertical and horizontal plywood patti both side cover with 6mm for grooving design and finishing with selected laminate. Before installation, make hole/face plate for conduit pipes of electrical/networking cables with openable stud from horizontal partition. The Vertical support of 18mm+18mm thick double plywood cover with 1mm laminate finish including teakwood bidding on exposed edges with melamine polish. The 38mm thick plywood with laminate finish top, fixed with necessary hardware, including suspended metal keyboard-mouse tray fixed with telescoping channel, cable manager and separate drawer with lock, telescoping channel and box, made from 18mm plywood with 1mm outside and 0.8mm inside laminate as well as 18mm post forming Outside of shutter with Auto hinges of standard make for Left or Right side. | Linear Workstation/counter (Size: 800mm Wide x 750 Height) Providing and fixing Cluster (Linear Workstation) as per drawing, Framing the skeleton with 18mm+18mm = 36mm thick vertical and horizontal plywood patti both side cover with 6mm for grooving design and finishing with selected laminate. Before installation, make hole/face plate for conduit pipes of electrical/networking cables with openable stud from horizontal partition. The Vertical support of 18mm+18mm thick double plywood cover with 1mm laminate finish including teakwood bidding on exposed edges with melamine polish. The 38mm thick plywood with laminate finish top, fixed with necessary hardware, including suspended metal keyboard-mouse tray fixed with telescoping channel, cable manager and separate drawer with lock, telescoping channel and box, made from 18mm plywood with 1mm outside and 0.8mm inside laminate as well as 18mm post forming Outside of shutter with Auto hinges of standard make for Left or Right side. |
| 33 | Table(Size: 1500mmx750mmx750mm) Providing and fixing 38mm thick plywood top with laminate finish with in approved shade with telescopic suspended metal keyboard with mouse tray with 57mm vertical legs made by plywood with laminate finish with. The Appron should be made from plywood with laminate finish with as per detail drawing, Drawer unit box with wooden bidding patti on nylon castor with lock and telescopic channel should be made from 18mm plywood with laminate outside 1.0mm and 0.8mm inside laminate finish. The shutter outside shall be laminate finish and 0.8mm inside laminate finish with Auto hinges and drawer should made from 18mm plywood with laminate finish in approved shade and CPU Trolley should be supplied of metal powder coated, Footrest (100x75mm) should be from teakwood with melamine polish finish in approved shade. The table shall have 12mm thick back painted designer glass top as per design. Including all materials and labour etc. complete as per detail drawing and instruction of Engineer-in-charge. | Table(Size: 1500mmx750mmx750mm) Providing and fixing 38mm thick plywood top with laminate finish with in approved shade with telescopic suspended metal keyboard with mouse tray with 57mm vertical legs made by plywood with laminate finish with. The Appron should be made from plywood with laminate finish with as per detail drawing, Drawer unit box with wooden bidding patti on nylon castor with lock and telescopic channel should be made from 18mm plywood with laminate outside 1.0mm and 0.8mm inside laminate finish. The shutter outside shall be laminate finish and 0.8mm inside laminate finish with Auto hinges and drawer should made from 18mm plywood with laminate finish in approved shade and CPU Trolley should be supplied of metal powder coated, Footrest (100x75mm) should be from teakwood with melamine polish finish in approved shade. The table shall have 12mm thick back painted designer glass top as per design. Including all materials and labour etc. complete as per detail drawing and instruction of Engineer-in-charge. |
| 34 | Full ht. storage (Size: 500mm Depth) Providing and fixing full ht. storage with 18mm thick plywood box frame work. The shutters shall be laminate finished with expose edge having wood beading in approved shade melamine polish. The vertical and horizontal exterior surface of plywood shall be laminate finish outside 1.0mm inside 0.8mm thk. laminate finish. The shutter shall have Auto hinges for Left or Right side opening. The plywood used shall be of MR grade. All edge beading should be in wood and matching to the selected laminates with magnet, lock, Auto hinges. Including all materials and labour etc. complete as per instruction of Engineer-in charge and consultant. | Full ht. storage (Size: 500mm Depth) Providing and fixing full ht. storage with 18mm thick plywood box frame work. The shutters shall be laminate finished with expose edge having wood beading in approved shade melamine polish. The vertical and horizontal exterior surface of plywood shall be laminate finish outside 1.0mm inside 0.8mm thk. laminate finish. The shutter shall have Auto hinges for Left or Right side opening. The plywood used shall be of MR grade. All edge beading should be in wood and matching to the selected laminates with magnet, lock, Auto hinges. Including all materials and labour etc. complete as per instruction of Engineer-in charge and consultant. |
| 35 | Equipment. storage (Size: 500mm Depth) Providing and fixing full ht. storage with 18mm thick plywood box frame work. The shutters shall be laminate finished with expose edge having wood beading in approved shade melamine polish. The vertical and horizontal exterior surface of plywood shall be laminate finish outside 1.0mm inside 0.8mm thk. laminate finish. The shutter shall have Auto hinges for Left or Right side opening. The plywood used shall be of MR grade. All edge beading should be in wood and matching to the selected laminates with magnet, lock, Auto hinges. Including all materials and labour etc. complete as per instruction of Engineer-in charge and consultant. | Equipment. storage (Size: 500mm Depth) Providing and fixing full ht. storage with 18mm thick plywood box frame work. The shutters shall be laminate finished with expose edge having wood beading in approved shade melamine polish. The vertical and horizontal exterior surface of plywood shall be laminate finish outside 1.0mm inside 0.8mm thk. laminate finish. The shutter shall have Auto hinges for Left or Right side opening. The plywood used shall be of MR grade. All edge beading should be in wood and matching to the selected laminates with magnet, lock, Auto hinges. Including all materials and labour etc. complete as per instruction of Engineer-in charge and consultant. |
| 36 | Gypsum Plain False ceiling work Pro. And fixing single layer water proof gypsum board 12.5 mm thick sections using water proof board of size 1220 mm x 1830 mm x 8.0 mm suspended by GI suspender channel of size 25 mm x 3 mm with intermediate channel og size 18 mm x 40 mm x 0.8 mm at 1220 mm center to center ceiling section of size 40 mm x 35 mm x 0.55 mm at 457 mm c/c and perimeter channel A of size 20 mm x 27 mm x 30 mm x 0.5 mm at edges & drops incl.paper tap sand sofit cleat, anchor fastener, scoch bolt connecting cleat,joining compound top coat on ceiling incl.making necy.opening for light fitting,diffuser etc. comp. as per detail drawing as directed by engineer in charge. | Gypsum Plain False ceiling work Pro. And fixing single layer water proof gypsum board 12.5 mm thick sections using water proof board of size 1220 mm x 1830 mm x 8.0 mm suspended by GI suspender channel of size 25 mm x 3 mm with intermediate channel og size 18 mm x 40 mm x 0.8 mm at 1220 mm center to center ceiling section of size 40 mm x 35 mm x 0.55 mm at 457 mm c/c and perimeter channel A of size 20 mm x 27 mm x 30 mm x 0.5 mm at edges & drops incl.paper tap sand sofit cleat, anchor fastener, scoch bolt connecting cleat,joining compound top coat on ceiling incl.making necy.opening for light fitting,diffuser etc. comp. as per detail drawing as directed by engineer in charge. |
| 37 | Grid False ceiling Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have , light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best thermal Insulation . The Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5& Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm center to center, and cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm center to center to form agrid of 1200X600mm and secondary cross ’T’ of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/partitions on a perimeter wall angle pre- coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles of approved texture (Fine Fissured/ Cosmos/Spintone) in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by engineer-in charge.Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of0.50 (Minimum) for Fine fissured/ Spintone/ Cosmos and 0.75 NRC for Globe, light reflection 85% non combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.for the best thermal Insulation. etc complete all as directed by Engineer-in-Charge. | Grid False ceiling Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have , light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best thermal Insulation . The Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5& Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm center to center, and cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm center to center to form agrid of 1200X600mm and secondary cross ’T’ of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/partitions on a perimeter wall angle pre- coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles of approved texture (Fine Fissured/ Cosmos/Spintone) in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by engineer-in charge.Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of0.50 (Minimum) for Fine fissured/ Spintone/ Cosmos and 0.75 NRC for Globe, light reflection 85% non combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.for the best thermal Insulation. etc complete all as directed by Engineer-in-Charge. |
| 38 | Providing and fixing of approved make Trap door with galvanized steel . Doors should be finished in Powder Coating with film thickness of 60 microns approx. in desired RAL Shades. The manufacturer company must be TUV Nord ISO 9001-2015 certified trap door and must be made from galvanized steel sheet. door must be concealed type of hinges and appropriate provision for hanging from celling. appropriate locking must be provided. Frame and door must made from minimum 1 mm galvanized steel. etc complete all as directed by Engineer-in-Charge. | Providing and fixing of approved make Trap door with galvanized steel . Doors should be finished in Powder Coating with film thickness of 60 microns approx. in desired RAL Shades. The manufacturer company must be TUV Nord ISO 9001-2015 certified trap door and must be made from galvanized steel sheet. door must be concealed type of hinges and appropriate provision for hanging from celling. appropriate locking must be provided. Frame and door must made from minimum 1 mm galvanized steel. etc complete all as directed by Engineer-in-Charge. |
| 39 | Full ht. Partly glazed aluminium partition Providing and fixing full height partly glazed partition with 10 mm toughen glass installation upto ceiling or beam bottom as per drawing and the structural framing of Aluminium square pipe size as per design all vertical and horizontal member 600mm c/c both direction fixed by aluminium angle size as per design for proper finishing with both side cover with 12 mm plywood with Laminate ,grooving detail as per design. with 10 mm toughen glass door including all hardware,heavy floor spring,handle,lock,door framing etc as per design.All exposed edges shall be covered with necessary sizes wooden patti finish with melamine polish in approved shade. The plywood fixing properly without any air gap and finishing with selected laminate finish as per design. The glass shall be finished with vinyl film as per design. Before installation, make hole/face plate for conduit pipes of electrical / networking cables with openable stud from partition. Rate shall include necessary itching film, Including all materials and labour etc. complete as per detail drawing and instruction of engineer-in charge and consultant. | Full ht. Partly glazed aluminium partition Providing and fixing full height partly glazed partition with 10 mm toughen glass installation upto ceiling or beam bottom as per drawing and the structural framing of Aluminium square pipe size as per design all vertical and horizontal member 600mm c/c both direction fixed by aluminium angle size as per design for proper finishing with both side cover with 12 mm plywood with Laminate ,grooving detail as per design. with 10 mm toughen glass door including all hardware,heavy floor spring,handle,lock,door framing etc as per design.All exposed edges shall be covered with necessary sizes wooden patti finish with melamine polish in approved shade. The plywood fixing properly without any air gap and finishing with selected laminate finish as per design. The glass shall be finished with vinyl film as per design. Before installation, make hole/face plate for conduit pipes of electrical / networking cables with openable stud from partition. Rate shall include necessary itching film, Including all materials and labour etc. complete as per detail drawing and instruction of engineer-in charge and consultant. |
| 40 | Full ht. glazed aluminium partition Providing and fixing full height partly glazed partition with 10 mm toughen glass installation upto ceiling or beam bottom as per drawing and the structural framing of Aluminium square pipe size as per design all vertical and horizontal member 600mm c/c both direction fixed by aluminium angle size as per design for proper finishing with both side cover with 12 mm plywood with Laminate ,grooving detail as per design. with 10 mm toughen glass door including all hardware,heavy floor spring,handle,lock,door framing etc as per design.All exposed edges shall be covered with necessary sizes wooden patti finish with melamine polish in approved shade. The plywood fixing properly without any air gap and finishing with selected laminate finish as per design. The glass shall be finished with vinyl film as per design. Before installation, make hole/face plate for conduit pipes of electrical / networking cables with openable stud from partition. Rate shall include necessary itching film, Including all materials and labour etc. complete as per detail drawing and instruction of engineer-in charge and consultant. | Full ht. glazed aluminium partition Providing and fixing full height partly glazed partition with 10 mm toughen glass installation upto ceiling or beam bottom as per drawing and the structural framing of Aluminium square pipe size as per design all vertical and horizontal member 600mm c/c both direction fixed by aluminium angle size as per design for proper finishing with both side cover with 12 mm plywood with Laminate ,grooving detail as per design. with 10 mm toughen glass door including all hardware,heavy floor spring,handle,lock,door framing etc as per design.All exposed edges shall be covered with necessary sizes wooden patti finish with melamine polish in approved shade. The plywood fixing properly without any air gap and finishing with selected laminate finish as per design. The glass shall be finished with vinyl film as per design. Before installation, make hole/face plate for conduit pipes of electrical / networking cables with openable stud from partition. Rate shall include necessary itching film, Including all materials and labour etc. complete as per detail drawing and instruction of engineer-in charge and consultant. |
| 41 | Full ht. solid aluminium partition Providing and fixing full height solid partition installation upto ceiling or beam bottom as per drawing and the structural framing of Aluminium square pipe size as per design all vertical and horizontal member 600mm c/c both direction fixed by aluminium angle size as per design for proper finishing with both side cover with 12 mm plywood with grooving detail as per design. with door including all hardware,heavy floor spring,handle,lock,framing etc as per design. All exposed edges shall be covered with necessary sizes wooden patti finish with melamine polish in approved shade. The plywood fixing properly without any air gap and finishing with selected laminate finish as per design. The glass shall be finished with vinyl film as per design. Before installation, make hole/face plate for conduit pipes of electrical / networking cables with openable stud from partition. Rate shall include necessary itching film, Including all materials and labour etc. complete as per detail drawing and instruction of engineer-in charge and consultant. | Full ht. solid aluminium partition Providing and fixing full height solid partition installation upto ceiling or beam bottom as per drawing and the structural framing of Aluminium square pipe size as per design all vertical and horizontal member 600mm c/c both direction fixed by aluminium angle size as per design for proper finishing with both side cover with 12 mm plywood with grooving detail as per design. with door including all hardware,heavy floor spring,handle,lock,framing etc as per design. All exposed edges shall be covered with necessary sizes wooden patti finish with melamine polish in approved shade. The plywood fixing properly without any air gap and finishing with selected laminate finish as per design. The glass shall be finished with vinyl film as per design. Before installation, make hole/face plate for conduit pipes of electrical / networking cables with openable stud from partition. Rate shall include necessary itching film, Including all materials and labour etc. complete as per detail drawing and instruction of engineer-in charge and consultant. |
| 42 | Panelling for BrandingProviding & fixing branding panelling work using 18mm thick commercial plywood / MDF board of approved make, fixed over wall surface with necessary wooden/aluminium framework including levelled support structure, screws, adhesives and fasteners complete.Surface shall be finished with approved branding material such as vinyl graphic printing / digital print / acrylic letters / ACP cladding / laminate finish as per approved design and artwork, including cutting, edge banding, grooves, joints, sealing, finishing and making good complete in all respects as per drawing and direction of Engineer-in-charge. | Panelling for BrandingProviding & fixing branding panelling work using 18mm thick commercial plywood / MDF board of approved make, fixed over wall surface with necessary wooden/aluminium framework including levelled support structure, screws, adhesives and fasteners complete.Surface shall be finished with approved branding material such as vinyl graphic printing / digital print / acrylic letters / ACP cladding / laminate finish as per approved design and artwork, including cutting, edge banding, grooves, joints, sealing, finishing and making good complete in all respects as per drawing and direction of Engineer-in-charge. |
| 43 | Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.etc complete all as directed by Engineer-in-Charge. | Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.etc complete all as directed by Engineer-in-Charge. |
| 44 | Demolition,RCC cutting including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. With RCC cutting and breking (i) R.C.C. work etc complete all as directed by Engineer-in-Charge. | Demolition,RCC cutting including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. With RCC cutting and breking (i) R.C.C. work etc complete all as directed by Engineer-in-Charge. |
| 45 | Demolition of Brick work and stone masonry including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar. All complete as directed by Engineer-in-charge. | Demolition of Brick work and stone masonry including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar. All complete as directed by Engineer-in-charge. |
| 46 | Removing and scraping of old deteriorated plaster of any thickness from wall / R.C.C member including stacking of serviceable material and disposal of unserviceable from site of work with all lead and lift. all cleaning and complete as specified & directed by Engineer-in-charge | Removing and scraping of old deteriorated plaster of any thickness from wall / R.C.C member including stacking of serviceable material and disposal of unserviceable from site of work with all lead and lift. all cleaning and complete as specified & directed by Engineer-in-charge |
| 47 | Dismantling doors, windows, ventilators etc.(wood or steel) shutters including chow hats architraves, holdfasts and other attachment etc. Complete and stacking them within all lead and lift all complete as directed by Engineer-in-charge.(I) Not exceeding 3 Smut in area. | Dismantling doors, windows, ventilators etc.(wood or steel) shutters including chow hats architraves, holdfasts and other attachment etc. Complete and stacking them within all lead and lift all complete as directed by Engineer-in-charge.(I) Not exceeding 3 Smut in area. |
| 48 | Dismentlingdoors,windows,ventilatorsetc. (wood or steel) shutters includingchowkhatsarchitraves, holdfastsandotherattachmentetc. completeandstackingthemwithinall leadandlift.(ii)Exceeding 3 Sq.M. in area. | Dismentlingdoors,windows,ventilatorsetc. (wood or steel) shutters includingchowkhatsarchitraves, holdfastsandotherattachmentetc. completeandstackingthemwithinall leadandlift.(ii)Exceeding 3 Sq.M. in area. |
| 49 | Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stackingof serviceable materilas anddisposal of unserviceablematerialswith all lead and lift.(ii) A.C. sheet/gypsum/grid ceiling roofing. | Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stackingof serviceable materilas anddisposal of unserviceablematerialswith all lead and lift.(ii) A.C. sheet/gypsum/grid ceiling roofing. |
| 50 | Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complet Cat. III | Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complet Cat. III |
| 51 | Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected with 6A Modular type switch and hum free EME step type electronic fan regulator mounted and accessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat. III | Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected with 6A Modular type switch and hum free EME step type electronic fan regulator mounted and accessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat. III |
| 52 | Point wiring for Tissino / Modular secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires, in below type of pipe to be erected complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC / wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. Note:- Maximum up to 6 mtrs length, excess will be considered as Mains for Secondary Point. (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete | Point wiring for Tissino / Modular secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires, in below type of pipe to be erected complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC / wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. Note:- Maximum up to 6 mtrs length, excess will be considered as Mains for Secondary Point. (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 53 | Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling with following type accessories Cat. III | Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling with following type accessories Cat. III |
| 54 | Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge. (8) Computer RJ-45 socket Cat.III | Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge. (8) Computer RJ-45 socket Cat.III |
| 55 | Providing & erecting Switch board for Computer or electric apparatus consisting of following modular type accessories mounted with PVC / Metallic concealed/open box with single mounting base frame covered with textured/metallic /white front plate,modules erected with necessary connections as directed 1 no. 6A/16A universal plug-switch combined.3 nos. 6A Switch3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III | Providing & erecting Switch board for Computer or electric apparatus consisting of following modular type accessories mounted with PVC / Metallic concealed/open box with single mounting base frame covered with textured/metallic /white front plate,modules erected with necessary connections as directed 1 no. 6A/16A universal plug-switch combined.3 nos. 6A Switch3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III |
| 56 | Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm | Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm |
| 57 | Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D x T) Cat-III[6] 300mm x 25mm x 1.6 mm with Three Compartments | Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D x T) Cat-III[6] 300mm x 25mm x 1.6 mm with Three Compartments |
| 58 | Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (b) 2 wire 2.5 sq. mm | Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (b) 2 wire 2.5 sq. mm |
| 59 | providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) with medium class Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm | providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) with medium class Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm |
| 60 | providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. | providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. |
| 61 | (f) One wire 10.00 sq. mm | (f) One wire 10.00 sq. mm |
| 62 | (g) One wire 16.00 sq. mm | (g) One wire 16.00 sq. mm |
| 63 | Supplying & erecting approved make LAN cable of following size in existing pipe as per direction [C] CAT - 6 | Supplying & erecting approved make LAN cable of following size in existing pipe as per direction [C] CAT - 6 |
| 64 | Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company mark/name 160V to 270V,Power Factor more than 0.95, THD < 15 %,CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20 (ii) 11-15 watts, Surge-2 KV Cat-lll | Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company mark/name 160V to 270V,Power Factor more than 0.95, THD < 15 %,CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20 (ii) 11-15 watts, Surge-2 KV Cat-lll |
| 65 | (iii) 16-20 watts, Surge-2 KV Cat-lll | (iii) 16-20 watts, Surge-2 KV Cat-lll |
| 66 | (B) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing complete.IP20 (vi) 36 watts, 24\\" x 24\\", Surge- 2KV Cat-lll | (B) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing complete.IP20 (vi) 36 watts, 24\\" x 24\\", Surge- 2KV Cat-lll |
| 67 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only Cat III | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only Cat III |
| 68 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.ICS=100% of ICU only Cat III | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.ICS=100% of ICU only Cat III |
| 69 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up to 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing ICS=100% of ICU only Cat III | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up to 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing ICS=100% of ICU only Cat III |
| 70 | Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary connections. (A) Suitable for 100 Amp. Capacity | Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary connections. (A) Suitable for 100 Amp. Capacity |
| 71 | (B) Suitable for 200 Amp. Capacity | (B) Suitable for 200 Amp. Capacity |
| 72 | (E) Suitable for 630 Amp. capacity | (E) Suitable for 630 Amp. capacity |
| 73 | providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III | providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III |
| 74 | Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (b)40 Amp. Cat.III | Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (b)40 Amp. Cat.III |
| 75 | (c)63 Amp. Cat.III | (c)63 Amp. Cat.III |
| 76 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for(B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI)(b) sheet steel double door (ii)6 way | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for(B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI)(b) sheet steel double door (ii)6 way |
| 77 | providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed (ii) 40Amps. DP Cat. III | providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed (ii) 40Amps. DP Cat. III |
| 78 | Providing and erecting required size Aluminium strip for earthing of H.T. , OCB / ACB / Transformer, LT panel board, Motors etc. using copper clamp. | Providing and erecting required size Aluminium strip for earthing of H.T. , OCB / ACB / Transformer, LT panel board, Motors etc. using copper clamp. |
| 79 | Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover. (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency. (b)For Electrical installation up to 11 KV in normal soil. Length of Pipe : 2.00 mtrsBack filling Compound :1 no. Bag of 25 Kg. | Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover. (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency. (b)For Electrical installation up to 11 KV in normal soil. Length of Pipe : 2.00 mtrsBack filling Compound :1 no. Bag of 25 Kg. |
| 80 | Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating. (B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory (i) with 350mm depth | Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating. (B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory (i) with 350mm depth |
| 81 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core) | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core) |
| 82 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 16 Sq. mm | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 16 Sq. mm |
| 83 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(H) 3 & 1/2 core 240 Sq. mm | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(H) 3 & 1/2 core 240 Sq. mm |
| 84 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (J) 240 Sq.mm. | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (J) 240 Sq.mm. |
| 85 | Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(C) 16 Sq.mm. | Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.(C) 16 Sq.mm. |
| 86 | Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy erected on existing hook or clamp with earthing. [Make shall be approved by Engineer in charge] | Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy erected on existing hook or clamp with earthing. [Make shall be approved by Engineer in charge] |
| 87 | Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.200mm with 1350RPM Cat.II | Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.200mm with 1350RPM Cat.II |
| 88 | Supply, Installation, Testing and Commissioning of IP based 4MP resolution (2560 × 1440), Dome Camera: H.265 4MP IR Vandal Proof Dome N/W Camera, 3.6mm Lens, Fixed Iris, 30M IR, Shutter Speed 1 s to 1/100,000 s, , DC12V/PoE, IP67/IK10, Basic IVA, Image sensor- 1 / 2.7\\" CMOS, Effective Pixels 2560 × 1440,Min. Illumination Color: 0.01 Lux @ F1.2, AGC ON; Color: 0.04 Lux @ F2.2, AGC ON; 0 lux with IR, Angle adjustment- Pan : 0°-355°, Tilt : 0°-67°, Rotation : 0°-355°, Focal Length- 3.6 mm @ F2.2,Defog, Lens Mount- M12, True day/night, 120dB WDR, Image features- 3D DNR, HLC & BLC, Corridor Pattern, IR cut filter with auto switch, Triple streams, Support multi-stream real time transmission, 4 zones video mask, Smart codec by ROI, SNR ≥52 dB, Video Compression H.265, H.264, Video Analytics- Object removal (object left/missing detection), scene change and video blur detection, intrusion and line crossing. Alarm Triggers- Motion detection, Intelligent video analytics, Network disconnect, video tampering, IP address conflict, Max Frame Rate 30fps @ 4MP (2560×1440), Triple streams, Five levels under VBR; Freely adjustable under CBR, time stamp, text overlay, flip & mirror, ROI, Saturation, Brightness, Chroma, Contrast, Wide Dynamic, Sharpen, white balance, video rotation, Scheduled profile settings, AGC, illegal login, SD Card full, SD Card error, Operating temperature - 30 °C to 60 °C, Relative Humidity 10 % to 90 %, Network-1 RJ45 10M/100M self-adaptive Ethernet port, Network protocol TCP/IP, UDP, DHCP, NTP, RTSP, PPPoE, DDNS, SMTP, FTP, UPnP, Unicast, Multicast, ICMP, HTTP, HTTPS, DNS, DDNS, RTP, RTCP, IGMP, 802.1X, QoS, Ipv4, Ipv6, Cyber Security -HTTPS / IP Filter / IEEE 802.1X / Blacklist & whitelist / account security / telnet access control / serial password, ONVIF Profile (S & G), HAPI3, FCC Part 15.107 Class A, FCC Part 15.109 Class A , EN 55032, EN 55035 (IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8), EN 55030-4, UL 62368-1, IEC 62368-1 EN 62368-1, RoHS (IEC 62321-3-1, IEC 62321-5, IEC 62321-4, IEC 62321-6, IEC 62321-7, IEC 62321-7-2, IEC 62321-8), WEEE, REACH, CE, NDAA, BIS, Built-in micro SD/SDHC/SDXC slot upto 128GB | Supply, Installation, Testing and Commissioning of IP based 4MP resolution (2560 × 1440), Dome Camera: H.265 4MP IR Vandal Proof Dome N/W Camera, 3.6mm Lens, Fixed Iris, 30M IR, Shutter Speed 1 s to 1/100,000 s, , DC12V/PoE, IP67/IK10, Basic IVA, Image sensor- 1 / 2.7\\" CMOS, Effective Pixels 2560 × 1440,Min. Illumination Color: 0.01 Lux @ F1.2, AGC ON; Color: 0.04 Lux @ F2.2, AGC ON; 0 lux with IR, Angle adjustment- Pan : 0°-355°, Tilt : 0°-67°, Rotation : 0°-355°, Focal Length- 3.6 mm @ F2.2,Defog, Lens Mount- M12, True day/night, 120dB WDR, Image features- 3D DNR, HLC & BLC, Corridor Pattern, IR cut filter with auto switch, Triple streams, Support multi-stream real time transmission, 4 zones video mask, Smart codec by ROI, SNR ≥52 dB, Video Compression H.265, H.264, Video Analytics- Object removal (object left/missing detection), scene change and video blur detection, intrusion and line crossing. Alarm Triggers- Motion detection, Intelligent video analytics, Network disconnect, video tampering, IP address conflict, Max Frame Rate 30fps @ 4MP (2560×1440), Triple streams, Five levels under VBR; Freely adjustable under CBR, time stamp, text overlay, flip & mirror, ROI, Saturation, Brightness, Chroma, Contrast, Wide Dynamic, Sharpen, white balance, video rotation, Scheduled profile settings, AGC, illegal login, SD Card full, SD Card error, Operating temperature - 30 °C to 60 °C, Relative Humidity 10 % to 90 %, Network-1 RJ45 10M/100M self-adaptive Ethernet port, Network protocol TCP/IP, UDP, DHCP, NTP, RTSP, PPPoE, DDNS, SMTP, FTP, UPnP, Unicast, Multicast, ICMP, HTTP, HTTPS, DNS, DDNS, RTP, RTCP, IGMP, 802.1X, QoS, Ipv4, Ipv6, Cyber Security -HTTPS / IP Filter / IEEE 802.1X / Blacklist & whitelist / account security / telnet access control / serial password, ONVIF Profile (S & G), HAPI3, FCC Part 15.107 Class A, FCC Part 15.109 Class A , EN 55032, EN 55035 (IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8), EN 55030-4, UL 62368-1, IEC 62368-1 EN 62368-1, RoHS (IEC 62321-3-1, IEC 62321-5, IEC 62321-4, IEC 62321-6, IEC 62321-7, IEC 62321-7-2, IEC 62321-8), WEEE, REACH, CE, NDAA, BIS, Built-in micro SD/SDHC/SDXC slot upto 128GB |
| 89 | Supply, Installation, Testing and Comissioning of 75\\" UHD Professional Display, 500 Nits Brightness, contrast ratio 50000:1, Operation: 24x7, Input ports: 1xVGA; 2xUSB 2.0, 4x HDMI 2.0 In, Secure USB 2.0 (Internal), RJ45, RJ12, RS232, Optical SPDIF, 1xHDMI 2.0 out, Supports Daisy Chain, Speaker 2x10 W, 30-degrees Tilting Installation, Open Content Management Support, Scheduler, USB-Autoplay, AutoLaunch, HDMI-CEC, HDMI-Wakeup, Auto-switch on Failover, Panel Lock, OSD Rotation, No Signal Power Off, Screen Saver, Pixel shift, Scheduler, Videowall support, Remote control via LAN, Realtime Clock, Joystick, Rocker Switch, Optional : SDM or OPS compatibility, Embedded IR, IR extender option, Optional: Overlay Touch Kit Compatibility, Certifications: Safety, EMC, CE. including 5 mtr. HDMI cable | Supply, Installation, Testing and Comissioning of 75\\" UHD Professional Display, 500 Nits Brightness, contrast ratio 50000:1, Operation: 24x7, Input ports: 1xVGA; 2xUSB 2.0, 4x HDMI 2.0 In, Secure USB 2.0 (Internal), RJ45, RJ12, RS232, Optical SPDIF, 1xHDMI 2.0 out, Supports Daisy Chain, Speaker 2x10 W, 30-degrees Tilting Installation, Open Content Management Support, Scheduler, USB-Autoplay, AutoLaunch, HDMI-CEC, HDMI-Wakeup, Auto-switch on Failover, Panel Lock, OSD Rotation, No Signal Power Off, Screen Saver, Pixel shift, Scheduler, Videowall support, Remote control via LAN, Realtime Clock, Joystick, Rocker Switch, Optional : SDM or OPS compatibility, Embedded IR, IR extender option, Optional: Overlay Touch Kit Compatibility, Certifications: Safety, EMC, CE. including 5 mtr. HDMI cable |
| 90 | Supply, Installation, Testing and Comissioning of 42\\" UHD Professional Display, 500 Nits Brightness, contrast ratio 50000:1, Operation: 24x7, Input ports: 1xVGA; 2xUSB 2.0, 4x HDMI 2.0 In, Secure USB 2.0 (Internal), RJ45, RJ12, RS232, Optical SPDIF, 1xHDMI 2.0 out, Supports Daisy Chain, Speaker 2x10 W, 30-degrees Tilting Installation, Open Content Management Support, Scheduler, USB-Autoplay, AutoLaunch, HDMI-CEC, HDMI-Wakeup, Auto-switch on Failover, Panel Lock, OSD Rotation, No Signal Power Off, Screen Saver, Pixel shift, Scheduler, Videowall support, Remote control via LAN, Realtime Clock, Joystick, Rocker Switch, Optional : SDM or OPS compatibility, Embedded IR, IR extender option, Optional: Overlay Touch Kit Compatibility, Certifications: Safety, EMC, CE. including 5 mtr. HDMI cable | Supply, Installation, Testing and Comissioning of 42\\" UHD Professional Display, 500 Nits Brightness, contrast ratio 50000:1, Operation: 24x7, Input ports: 1xVGA; 2xUSB 2.0, 4x HDMI 2.0 In, Secure USB 2.0 (Internal), RJ45, RJ12, RS232, Optical SPDIF, 1xHDMI 2.0 out, Supports Daisy Chain, Speaker 2x10 W, 30-degrees Tilting Installation, Open Content Management Support, Scheduler, USB-Autoplay, AutoLaunch, HDMI-CEC, HDMI-Wakeup, Auto-switch on Failover, Panel Lock, OSD Rotation, No Signal Power Off, Screen Saver, Pixel shift, Scheduler, Videowall support, Remote control via LAN, Realtime Clock, Joystick, Rocker Switch, Optional : SDM or OPS compatibility, Embedded IR, IR extender option, Optional: Overlay Touch Kit Compatibility, Certifications: Safety, EMC, CE. including 5 mtr. HDMI cable |
| 91 | Supply, Installation, Testing & Commissioning of 15U (550W X 600D)MM Wall mount closed rack with PDU, Horizontal Cable manager, self, mounting hardware and cooling fan with standard accessories. UL Certified. Racks should be manufactured by ISO9001:2015, ISO14001:2004 & OHSAS 18001 : 2007, DIN41494 and Equivalent should have proper EHS Policy. | Supply, Installation, Testing & Commissioning of 15U (550W X 600D)MM Wall mount closed rack with PDU, Horizontal Cable manager, self, mounting hardware and cooling fan with standard accessories. UL Certified. Racks should be manufactured by ISO9001:2015, ISO14001:2004 & OHSAS 18001 : 2007, DIN41494 and Equivalent should have proper EHS Policy. |
| 92 | Supply, Installation, Testing & Commissioning of High Quality NVR of 200Mbps Bit Rate Input Max(up to 32-ch IP video), 4 SATA Interfaces, alarm I/O: 16/4, 1.5U case, 19\\" | Supply, Installation, Testing & Commissioning of High Quality NVR of 200Mbps Bit Rate Input Max(up to 32-ch IP video), 4 SATA Interfaces, alarm I/O: 16/4, 1.5U case, 19\\" |
| 93 | Supply, Installation, Testing & Commissioning of 16 CH POE SWITCH ETHERNET CABLE THRU POWER SUPPLY | Supply, Installation, Testing & Commissioning of 16 CH POE SWITCH ETHERNET CABLE THRU POWER SUPPLY |
| 94 | Supply, Installation, Testing & Commissioning of 5 kVA Online Double Conversion UPS suitable for Testing Laboratory application with 1 Phase Input & 1 Phase Output configuration, input voltage 160–280 VAC, output voltage 230 VAC, minimum 10–15 minutes backup, efficiency >90%, complete with SMF VRLA batteries, battery rack/cabinet, necessary wiring, earthing, accessories etc. | Supply, Installation, Testing & Commissioning of 5 kVA Online Double Conversion UPS suitable for Testing Laboratory application with 1 Phase Input & 1 Phase Output configuration, input voltage 160–280 VAC, output voltage 230 VAC, minimum 10–15 minutes backup, efficiency >90%, complete with SMF VRLA batteries, battery rack/cabinet, necessary wiring, earthing, accessories etc. |
| 95 | Supply, Installation, Testing & Commissioning of back box with blank plat for camera | Supply, Installation, Testing & Commissioning of back box with blank plat for camera |
| 96 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) |
| 97 | Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System(A) 1.0 TR | Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System(A) 1.0 TR |
| 98 | …do...(B) 2.4 TR | …do...(B) 2.4 TR |
| 99 | …do...(C) 2.8 TR | …do...(C) 2.8 TR |
| 100 | Supply, installation, testing and commissioning of following minimum capacity One way flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System(A) 2.0 TR | Supply, installation, testing and commissioning of following minimum capacity One way flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System(A) 2.0 TR |
| 101 | All refrigerant Joints and Ref Header for the system | All refrigerant Joints and Ref Header for the system |
| 102 | Central Control System (A) Cord type remote control with thermostat, LED Display and internal wiring for Cassette, FCU & CSU | Central Control System (A) Cord type remote control with thermostat, LED Display and internal wiring for Cassette, FCU & CSU |
| 103 | (B) Central wired Remote Control System | (B) Central wired Remote Control System |
| 104 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(A) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(A) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 105 | ……….(do)……..(B) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)……..(B) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 106 | ……….(do)……..(C) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)……..(C) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 107 | ……….(do)…….(D) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)…….(D) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 108 | ……….(do)…….(E) 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)…….(E) 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 109 | ……….(do)…….(F) 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)…….(F) 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 110 | ……….(do)…….(H) 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)…….(H) 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 111 | ……….(do)…….(I) 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)…….(I) 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 112 | ……….(do)…….(K) 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)…….(K) 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 113 | ……….(do)…….(L) 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation | ……….(do)…….(L) 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 114 | M.S.Structure for installing VRV outdoor units duly Painted with synthetic enamel paints. | M.S.Structure for installing VRV outdoor units duly Painted with synthetic enamel paints. |
| 115 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.(A) 32MM Dia. | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.(A) 32MM Dia. |
| 116 | …do...(B) 25MM Dia. | …do...(B) 25MM Dia. |
| 117 | Testing & Commissioning Charges along with topping-up of R-410a refrigerant. | Testing & Commissioning Charges along with topping-up of R-410a refrigerant. |
| 118 | Supplying & fixing 50mm thick TF quality expanded polystyrene for underdeck insulation on slab/wall /shaft exposed to sun/atmosphere as per specifications. | Supplying & fixing 50mm thick TF quality expanded polystyrene for underdeck insulation on slab/wall /shaft exposed to sun/atmosphere as per specifications. |
| 119 | Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments..(A) 3C X 1.5 Sq mm Shielded Armoured | Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments..(A) 3C X 1.5 Sq mm Shielded Armoured |
| 120 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(A) 4 core 25 Sq. mm | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(A) 4 core 25 Sq. mm |
| 121 | 25 X 3 mm GI Strip | 25 X 3 mm GI Strip |
| 122 | 6 SWG GI Wire | 6 SWG GI Wire |
| 123 | Electrical panel board vrv system in compartmentalised and weather proof construction with copper bus bar, star delta starter, sfu, tpn mcb, push buttons, indicating lamps, a meters, v meters, digital load manager, indicating lamps, delay timers, ryb led lamps, control wiring and protection system etc. | Electrical panel board vrv system in compartmentalised and weather proof construction with copper bus bar, star delta starter, sfu, tpn mcb, push buttons, indicating lamps, a meters, v meters, digital load manager, indicating lamps, delay timers, ryb led lamps, control wiring and protection system etc. |
| 124 | GI LADDER & PERFORATED TYPE CABLE TRAYS & COVERS : SUPPLY, INSTALLATION IN HORIZONTAL & VERTICAL FORMATION OF PREFABRICATED PERFORATED/ LADDER TYPE HOT DIPPED GI CABLE TRAYS DIFFERENT WIDTHS AND DELIVERED IN STANDARD LENGTHS ALONG WITH COUPLER PLATES AND REQUISITE NUMBER OF HARDWARE, AT DIFFERENT LEVELS ALONG PIPE RACK, READY MADE CABLE TRENCHES, CABLE CELLAR, ETC., IN TIER FORMATION AS PER SPECIFICATIONS, DRAWINGS, STANDARD ENGINEERING PRACTICE AND AS PER THE DIRECTION OF ENGINEER-IN-CHARGE. THE CONTRACTOR''S SCOPE IS INCLUSIVE OF LIFTING & PLACING OF TRAYS ON SUPPORTS AT DIFFERENT LEVELS, ALIGNING, JOINING OF TRAYS WITH COUPLERS, CLAMPING/ FASTENING OF SUPPORTS TO THE RCC/METALIC STRUCTURE & CLAMPING /FASTENING OF CABLE TRAY TO THE SUPPORT OF THE VERTICAL PORTIONS AND WHEREVER REQUIRED AS PER SPECS/ DRAWINGS, ALL THE NECESSARY BENDS (HORIZONTAL/ VERTICAL), TEES, CROSS, ELBOWS, REDUCERS, ETC., AS SHOWN IN THE DRAWING AND AS PER THE SITE. RATE IS INCLUSIVE OF ALL THE INSTALLATION ACCESSORIES LIKE COUPLERS, NUT, BOLTS, ANCHOR FASTNERS ETC CABLE TRAY 300MM WIDE CABLE TRAY PERFORATED TYPE (1.6 MM THICK & 50 MM HIGH COLLAR) | GI LADDER & PERFORATED TYPE CABLE TRAYS & COVERS : SUPPLY, INSTALLATION IN HORIZONTAL & VERTICAL FORMATION OF PREFABRICATED PERFORATED/ LADDER TYPE HOT DIPPED GI CABLE TRAYS DIFFERENT WIDTHS AND DELIVERED IN STANDARD LENGTHS ALONG WITH COUPLER PLATES AND REQUISITE NUMBER OF HARDWARE, AT DIFFERENT LEVELS ALONG PIPE RACK, READY MADE CABLE TRENCHES, CABLE CELLAR, ETC., IN TIER FORMATION AS PER SPECIFICATIONS, DRAWINGS, STANDARD ENGINEERING PRACTICE AND AS PER THE DIRECTION OF ENGINEER-IN-CHARGE. THE CONTRACTOR''S SCOPE IS INCLUSIVE OF LIFTING & PLACING OF TRAYS ON SUPPORTS AT DIFFERENT LEVELS, ALIGNING, JOINING OF TRAYS WITH COUPLERS, CLAMPING/ FASTENING OF SUPPORTS TO THE RCC/METALIC STRUCTURE & CLAMPING /FASTENING OF CABLE TRAY TO THE SUPPORT OF THE VERTICAL PORTIONS AND WHEREVER REQUIRED AS PER SPECS/ DRAWINGS, ALL THE NECESSARY BENDS (HORIZONTAL/ VERTICAL), TEES, CROSS, ELBOWS, REDUCERS, ETC., AS SHOWN IN THE DRAWING AND AS PER THE SITE. RATE IS INCLUSIVE OF ALL THE INSTALLATION ACCESSORIES LIKE COUPLERS, NUT, BOLTS, ANCHOR FASTNERS ETC CABLE TRAY 300MM WIDE CABLE TRAY PERFORATED TYPE (1.6 MM THICK & 50 MM HIGH COLLAR) |
| 125 | …DO… 150MM WIDE CABLE TRAY PERFORATED TYPE (1.6 MM THICK & 50 MM HIGH COLLAR) | …DO… 150MM WIDE CABLE TRAY PERFORATED TYPE (1.6 MM THICK & 50 MM HIGH COLLAR) |
| 126 | INTERNAL PIPING : SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ABOVE GROUND ''HOT DIP GALVANIZED MS ERW PIPES (C CLASS /HEAVY GRADE) CONFIRMING TO IS 1239 UP TO 150 MM DIA & IS 3589 FOR 200MM DIA & ABOVE , INCLUDING CUTTING, THREADING, X-RAY QUALITY WELDING ETC. AND PROVIDING ALL FITTINGS E.G. ELBOWS, REDUCERS, FLANGES (CONFIRMING TO CLASS ASA 150 COMMERCIAL ), GASKETS, NUTS, BOLTS & WASHERS ETC. INCLUDING PAINTING OF PIPES & FITTINGS WITH P.O.RED PAINT OVER A COAT OF READY MIXED PRIMER, BOTH OF APPROVED QUALITY & SHADE AS PER IS-5, INCLUDING CUTTING HOLES & CHASES IN BRICK OR RCC WALLS/SLABS, FIXING ON EARTH BY SUITABLE STRUCTURAL SUPPORTS & RUBBER PADDING TO BE PROVIDED ON EACH PEDESTALS HYDROSTATIC TESTING FOR 2 HOURS AT 150% OF THE SYSTEM PRESSURE, HOOK-UP ETC. COMPLETE WITH ALL ACCESSORIES AS PER APPROVED DRAWINGS, SPECIFICATION AND DIRECTION OF THE ENGINEER-IN-CHARGE, WITH ALL COMPLETE IN ALL RESPECT AS REQUIRED & UP TO THE SATISFACTION OF ENGINEER INCHARGE. 25 NB | INTERNAL PIPING : SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ABOVE GROUND ''HOT DIP GALVANIZED MS ERW PIPES (C CLASS /HEAVY GRADE) CONFIRMING TO IS 1239 UP TO 150 MM DIA & IS 3589 FOR 200MM DIA & ABOVE , INCLUDING CUTTING, THREADING, X-RAY QUALITY WELDING ETC. AND PROVIDING ALL FITTINGS E.G. ELBOWS, REDUCERS, FLANGES (CONFIRMING TO CLASS ASA 150 COMMERCIAL ), GASKETS, NUTS, BOLTS & WASHERS ETC. INCLUDING PAINTING OF PIPES & FITTINGS WITH P.O.RED PAINT OVER A COAT OF READY MIXED PRIMER, BOTH OF APPROVED QUALITY & SHADE AS PER IS-5, INCLUDING CUTTING HOLES & CHASES IN BRICK OR RCC WALLS/SLABS, FIXING ON EARTH BY SUITABLE STRUCTURAL SUPPORTS & RUBBER PADDING TO BE PROVIDED ON EACH PEDESTALS HYDROSTATIC TESTING FOR 2 HOURS AT 150% OF THE SYSTEM PRESSURE, HOOK-UP ETC. COMPLETE WITH ALL ACCESSORIES AS PER APPROVED DRAWINGS, SPECIFICATION AND DIRECTION OF THE ENGINEER-IN-CHARGE, WITH ALL COMPLETE IN ALL RESPECT AS REQUIRED & UP TO THE SATISFACTION OF ENGINEER INCHARGE. 25 NB |
| 127 | …DO… 32 NB | …DO… 32 NB |
| 128 | …DO… 40 NB | …DO… 40 NB |
| 129 | …DO… 50 NB | …DO… 50 NB |
| 130 | …DO… 65 NB | …DO… 65 NB |
| 131 | …DO… 80 NB | …DO… 80 NB |
| 132 | …DO… 100 NB | …DO… 100 NB |
| 133 | …DO… 150 NB | …DO… 150 NB |
| 134 | SITC of Above/below Analogue Addressable Smoke Sensor which is fully compatible with Analogue Addressable Protocol, having removable high performance chamber with Twin fire LED''s allow 360 degree viewing, User selectable sensitivity modes 1% to 4.5% obs/m, Incorporate Optical elements, lock mechanism (sensor to base), Electronically addressed, Pulsing/non-pulsing controlled from panel. Approved by LPCB & VdS. | SITC of Above/below Analogue Addressable Smoke Sensor which is fully compatible with Analogue Addressable Protocol, having removable high performance chamber with Twin fire LED''s allow 360 degree viewing, User selectable sensitivity modes 1% to 4.5% obs/m, Incorporate Optical elements, lock mechanism (sensor to base), Electronically addressed, Pulsing/non-pulsing controlled from panel. Approved by LPCB & VdS. |
| 135 | SITC of Co2 type Fire Extinguisher with valve, initial Fill, wall bracket complete – 4.5 Kg capacity.BS:5423/ISO7165/ NFPA10/ BS EN 3 part 1 to 6/ IS:15683 | SITC of Co2 type Fire Extinguisher with valve, initial Fill, wall bracket complete – 4.5 Kg capacity.BS:5423/ISO7165/ NFPA10/ BS EN 3 part 1 to 6/ IS:15683 |
| 136 | SPRINKLER FLEXIBLE DROP PIPES MADE OF CORRUGATED SS TUBING TO WITH STAND 16 BAR PRESSURE WITH WELDED REDUCER ON ONE END TO DIRECTLY ACCOMMODATE SPRINKLER & FEMALE CHECKNUT ON THE OTHER END TO CONNECT TO THE BRANCH PIPE WITH SUPPORTS COMPLETE - 1000 MM LONG. | SPRINKLER FLEXIBLE DROP PIPES MADE OF CORRUGATED SS TUBING TO WITH STAND 16 BAR PRESSURE WITH WELDED REDUCER ON ONE END TO DIRECTLY ACCOMMODATE SPRINKLER & FEMALE CHECKNUT ON THE OTHER END TO CONNECT TO THE BRANCH PIPE WITH SUPPORTS COMPLETE - 1000 MM LONG. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail