| 1 | SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 3 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 5 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed. |
| 6 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed. |
| 7 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed. |
| 8 | Pre-painted galvalume aluminium zinc coating galvanised iron based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specifed and directed. |
| 9 | Pre-painted galvalume aluminium zinc coating galvanised iron based plain steel sheet 0.80mm of any colour having tensile strength of 550Mpa as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), fixed with self tapping screws complete all as specifed and directed. |
| 10 | Anodised aluminium snap grid frame work for false ceiling, powder coated, comprising of aluminium Tee (weight of section not less than 280 gms/mtr) and aluminium angle (weight of section not less than 280 gms/mtr), grid size 605x605mm, including Hangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed. |
| 11 | Providing and fixing everest board 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, grid size 595x595mm, for false ceiling all as specified, complete all as specified and as directed. |
| 12 | Plain cement concrete M-15(1:2:4), type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed. |
| 13 | Non-skid Ceramic coloured tiles 7mm to 8mm thick (square/ rectangular), area of each tile exceeding 0.09 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 14 | Non-skid Ceramic coloured tiles 7mm to 8mm thick (square/ rectangular), area of each tile exceeding 0.09 Sqm but not exceeding 0.11Sqm, in skirting or in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including fixed over screed bed or bedding layer of mortar 10mm thick in cement mortar 1:4, complete all as specified and as directed. |
| 15 | Granite (of any type) work (table rubbed and polished), 20mm thick, as in cooking plateform, steps, jambs, pillars, window cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, and including laid over screed bed or bedding layer 20mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 16 | Vitrified Ceramic tiles of light shade, 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 17 | Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed. |
| 18 | Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 19 | Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed. Please Enable Macros to View BoQ information |