| 1 | Dismantling of plain of corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and directed. |
| 2 | Supply & Fixing pre-painted galvalume aluminium zinc coating GI based semi corrugated steel sheet 0.50 mm thick of colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws complete all as specified and directed. |
| 3 | Supply & Fixing pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall and vally gutter, fixed with self tapping screws complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | Supply & Fixing Mild steel angle Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates etc. Fe290 Gde E-165,complete all as specified directed. |
| 6 | Material and Labour for preparation of newly steel surface of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 7 | Material and Labour for preparation of old painted steel surface of any description not other wise described, over 10cm width or girth and applying one coat of synthetic enamel paint. complete all as specified and directed. |
| 8 | Taking down cement plaster on brick or concrete walls, ceiling etc, including racking out joints , hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 9 | Material and Labour for rendering 12mm thick cement plaster in cement mortar (1:6) on brick or concrete surfaces of walls etc., finished even and smooth without extra cement complete all as specified and directed. |
| 10 | Material and Labour for 15 mm thick rendering in cement mortar 1:4 mixed with water proofing compound @ of 3% on brick or concrete surface of walls etc. finished surface even and fair without using extra cement complete all as specified and directed. Note : Supply only water proofing liquid shall be measured and paid separately. |
| 11 | Supply only liquid water proofing compound to mixed with cement mortar etc, complete all as specified and directed. |
| 12 | Material and Labour for preparing New plastered surfaces and applying two or coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces complete all as specified and directed. |
| 13 | Material and Labour preparing old plastered surfaces and applying two or coats of 100% Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces complete all as specified directed. |
| 14 | Material and Labour preparing New plastered surfaces on walls etc. and applying one coat of primer paint, and two coats of oil bound distemper, including preparation with wall care putty complete all as specified and directed. |
| 15 | Material and Labour complete removal of old treatment on walls etc. and applying one coat of primer paint, and two coats of oil bound distemper over wall care putty to make surface smooth complete all as specified and directed. |
| 16 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc, complete all as specified and directed. |
| 17 | Material and Labour Brick work with sub class \\"B\\" old size bricks, straight or curved on plan exc 6 m mean radius , built in cement mortar 1:6 complete all as specified and directed. |
| 18 | Takingdown Shutters of any description exc 2 sq. m each (Old rolling shutter) complete all as specified and directed. |
| 19 | Taking down chowkats or frames with shutters (without taking off shutter from the frames) n. exc. 1.5 sqm complete all as specified and directed. |
| 20 | Taking down chowkats or frames with shutters (without taking off shutter from the frames) exc. 1.5 sqm but not exc. 4 sqm each complete all as specified and directed. |
| 21 | S&F Factory made steel window/ventilator box type, primer coated , comprising made out of ERW Hollow 'P' section of size 6mm x 25mm of wall thickness frame 1.25mm Double rebated frame and comprising glazed and skelton shutter made of ERW sec 50mmx20mm with 1mm thick wall thickness and operated leaf side top hung divided in three panel by flat iron suitable size complete welded to frame of shutter and openable shutter Material and labour for Box type steel window, ERW hollow P-Section size 60 mm x 25 mm, double rebated ERW section of 1.25mm thick, comprising of glazed skelton & gauzed shutter of ERW tube P-Section size 50mm x 20mm with one No openable leaf for each shutter consisting of two Nos Sashbar of T-section 20 x 3 mm welded to frame with one No verticle mullion of ERW box type T Section of size 60mm x 25mm and FI 2mm thick welded/screwed to frame for fixing of glass including fittings and fixture like as Handle, Tower Bolt, Stopper, Cleat, Pintal hinges, holdfast and guard bars etc as given below all as shown on drg No CEJZ/TD-1020/08 SH 1/3 to 3/3 dated 01 may 2008 complete all as specified and directed as follows:-(a) Hold fast 150mm long of MS flat 12mm x 3mm - 4 Nos per Window(b) Handle of Z section 20mm x 25mm, 100mm long- 01 No per leaf(c) MS tower bolt 150mm long - 02 Nos per leaf(d) Z Section stopper 20mm x 25mm, 100mm long - 01 No per leaf(e) Cleat 55mm long of hollow square 15mm, 0.63mm thick- 01 Nos per leaf(f) MS pintol hinges size 75mmx12mm - 2 Nos per leaf (g) MS guard bar 10mm square bars @ 10cm c/c fixed horizontly (h) 3mm thick clear glass sheet 3 Nos per leaf glazing with oil putty(i) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in each leafNote :- Including taking down old steel / wooden window including hold fast PCC 1:2:4 type B0 (four No’s for Each window) & around required plaster in CM 1:4 and match with existing finish complete all as specified and directed by Engineer-in-charge. Painting shall be measured and paid separately. |
| 22 | Supply & Fixing factory made Presed steel frames for doors Size of frame 105 x 60 mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete as specified supplied and fixed EIC. |
| 23 | Supply & Fixing factory made 30 mm thick Flush shutters , solid core construction , with block board core and covered with 0.50 mm thick laminate on both side wood grain texture with lipping to match, complete all as specified and directed. |
| 24 | Supply & Fixing 100mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified directed. |
| 25 | Supply & Fixing 150mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, complete all as specified directed. |
| 26 | Supply & Fixing 250 mm Aluminium alloy, anodised, sliding door bolts with hasp and stapple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed. |
| 27 | Supply & Fixing fixed in repair Aluminium (extruded Section body) door closer hydrau lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed. |
| 28 | Supply & Fixing 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor and fixed,complete all as specified and directed. |
| 29 | Material and Labour for painting to New wooden surface of any description not other wise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces etc, complete all as specified and directed. |
| 30 | Supply & Fixing factory made 1.25mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;erected in position as indicated, complete, but gear operated type with bevel gear box and crank handle,etc, complete all as specified and directed. |
| 31 | Material & labour for preparation of newly steel surface of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint, complete all as per specified and directed. |
| 32 | Supply & Fixing 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, incl hacking out complete all as specified directed. |
| 33 | Supply & Fixing Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples , complete all as specified directed. |
| 34 | Material and Labour for 75 mm thick, plain cement concrete 1:3:6, type C-1 using 20 mm graded crushed stone aggregates, laid in 1:20 slop as in Plinth protection / paving / shafts including making joints at 3.00 m intervals and at each corner, the joint shall be filled with mastic filling to full depth) comprising of one partheated hot below bitumen 85/25, two parts heated sand (by volume) as per TD Drg No CEJZ/TD-1058/08 Sheets No 1/4 and 3/4 as applicable as per site, surface fininshed even and fair without using extra cement complete all as specified. Note : The concrete shall be laid at a stretch not exceeding 3 m in legth and width of joint shall not more than 12mm. |
| 35 | Material and Labour for preparation of old steel surface of any description not other wise described, over 10cm width or girth and applying one coat of synthetic enamel paint. complete all as specified and directed. |
| 36 | Dimantaling wooden frame truss exc 10m but n.exc 15m complete all as specified and directed |
| 37 | Taking down carefully the existing aluminium point wiring surface or coceiled of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets,ceiling rose, regulators, lamp holders, bell, light fittings etc. by unscrewing and taken away from site complete including necessary cuttings, chases and making good as required complete all as specified and directed. |
| 38 | Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, multistranded with copper conductors conforming to IS specifications, drawn through and including conceled conduit concealed / fixed on wall / ceiling with suitable clamps, screws, etc. or concealed in wall including terminal boxes fabricated with 1.6 mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc., including provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for following point :- |
| 39 | (a) One 3 pin 5 amps switch socket on same board. |
| 40 | Supply and fix switch Piano type one way 6 A, SP, 230 Volts complete all as specified and directed. |
| 41 | Supply and fix three pin socket Piano type one way 6 A, SP, 230 Volts complete all as specified and directed. |
| 42 | Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 6 Amperes Modular type, 230 volts AC complete all as specified and directed. |
| 43 | Supply and fixing in repair LED light fitting 1x20 Watt 220 volt, AC Decorative Box type with driver double sidded connection , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilig rose complete all as specified and directed. |
| 44 | Supply & Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65x50 mm three terminal complete all as specified and directed. |
| 45 | Material and Labour in repair for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 4 sqmm including 1 run of 4 sq mm single core multistranded copper conductor, PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring . Make of FRLS wire; Polycab/Havells/RR Cable,Make of PVC Pipe - Polycab/FInolex/Kalinga premium. Note : 2 Run of 4 sqmm, 1 Run of 4 sq mm and 1 run of PVC conduit will be mesuared as 1 unit. |
| 46 | Supply & Fixing in repair Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate) |
| 47 | Supply & Fixing in repair Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. Make :Legrand/Hager /Schneider Elect . (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate) |
| 48 | Supply and Laying in replacement in trenches / drawn through pipes or in road crossings / paths / drains / ducts / floors / along poles / equipments etc., of LT cable under ground, heavy duty, armoured, XLPE insulated with multi-stranded aluminium conductor cable conforming to IS-7098 Part-I (1998), 1100 Volts grade of 10 Sqmm 4 core nominal cross sectional area including necessary double compression copper gland and connecting up using suitable size aluminium lugs testing, incl taking down old unsv one from site complete all as specified and directed. NOTE: Excavation & earthwork, sand cushioning, protection to cable will be measured and paid for separately |
| 49 | Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 25 mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of submersible flat cable complete all as directed. |
| 50 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying cables, etc. and getting out in soft/loose soil and in road cutting all as specified and as directed |
| 51 | Returning, filling in excavated material / soil including spreading, leveling, watering and well ramming in layers n exc 25cm in soil complete all as specified and directed. |
| 52 | Removing excavated material / surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above starting point complete all as specified and directed. |
| 53 | Supply & Fixing in repair MCB double pole, 240 volts, 32 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. |
| 54 | Supply & Fixing in repair MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. |
| 55 | Supply and Fixing in repair bus bar enclosure 800 mm x 600 mm x 200 mm made out of 3.15 mm thick CRCA steel duly powder coated and including100 amp, 25 kA MCCB 4 pole, thermal magnetic based fitted in bus bar enclosure using 250 Amp rated bus bar, 25x10mm aluminium and RYB indication lamps duly protected by 2A SP MCB outdoor type welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 ; Complete all as specified and directed. Note - Height of the enclouser from ground level 0.5 metre . |
| 56 | Material and Labour in repair / replacement outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 1100 XLPE underground cable size 10 sqqm to 25 sqmm 4 core including testing after jointing complete all as specified and directed. |
| 57 | Supply and fix in replacement of security light fitting LED 35 Watt aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old CFL security light fitting complete all as specified and directed. Please Enable Macros to View BoQ information |