| 1 | Demolition of concrete in ground floor and pavings n.exc 15 cm thickness below or above ground level complete all as specified and as directed. |
| 2 | Demolition of reinforced concrete roofs, floors (other than ground floors), beams, staircases, landing, chajjas slabs; covers and similar suspended work complete all as specified and as directed. |
| 3 | Demolition of cement concrete (unreinforced) in roof (tiling), staircase landing, floors (other than ground floor) including removal of debrish out of MoD Land including material and labour for necessary scaffolding, safety arrangement and formwork upto G+3 storeys complete all as specified and as directed. |
| 4 | Taking down existing tarfelt including plaster including material and labour for necessary scaffolding, safety arrangement and formwork upto G+3 storeys complete all as specified and as directed. |
| 5 | Demolition of cement concrete (unreinforced) in roof (tiling), staircase landing ,floors (other than ground floor) including removal of debrish out of MoD Land including material and labour for necessary scaffolding, safety arrangement and formwork upto G+3 storeys complete all as specified and as directed. |
| 6 | Rooting out trees, flora & fauna and foliage as grown on RCC roof surfaces and brick/stone walls by cutting hole into slabs/walls for digging out roots and using chemical to burn deep rooted tree roots etc and making good dirturb portion of wall/roof with cement concrete (1:2:4) type B-1 complete all as specified and as directed. |
| 7 | M&L for 18/19mm thick preleminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber framework including 10mm thick IInd class H.W looping all round as in shelves of design as approved by Engineer in charge. etc and including dismantling old boarding any description fixed with screws complete all as specified and as directed by Engr-in-Charge. |
| 8 | M&L for providing cement concrete (1:2:4), type B-0, (using 12.5 mm graded stone aggregate) as in roof padding to maintain slope etc including material and labour for necessary scaffolding, safety arrangement and formwork upto G+3 storeys complete all as specified and as directed. |
| 9 | M&L for preparation surface including cleaning of all dirt and providing the following water proofing treatment in narrow width over the roof gutter of stores houses or chajjah/canopy/parapet wall, below PVC/RCC water tanks etc of G+3 storied building accessible / non accessible RCC roof to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and as directed by Engineer-in-Charge:- (a) Cleaning of all foreign material such as fungus, mass, dust etc by brushing and dusting, sprinkle water on surface, surface shall be levelled with a layer of 20 mm thick CM (1:4) mixed with water proofing admixture WPC @3% by weight of as per manufacturer's insturctions.(b) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface.(c) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm.(d) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc.(e) Membrane bonded completely to the substrate & the over laps are then sealed/fused by flame and including two coats of water proofing bituminous aluminum paint on top of APP membrane complete all as specified and as directed. |
| 10 | M&L for cement concrete tiles 20cm x 20cm x 20mm thick machine pressed, set & pointed in neat cement slurry in floor with grey cement and no pigment and cut and polished on roof over and including 15 mm thick screed bed in CM (1:4) including material and labour for necessary scaffolding, safety arrangement and formwork upto (G+3) storeys complete all as specified and as directed. |
| 11 | M&L for special treatment for sunken portion of WCs/Bath & toilet etc executed in following stages:-Stage 1: Cleaning of all foreign material such as fungus, mass, dust etc by brushing and dusting, sprinkle water on surface, surface shall be levelled with a layer of 20 mm thick CM (1:4) mixed with water proofing admixture WPC @3% by weight of as per manufacturer's insturctions.State 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces.Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufacturer's instructions.Stage 4: Laying fibre glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky.Stage 5: After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer's instructions.Stage 6: Providing 15mm thick protective plaster in CM (1:3) mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer's instructions.Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTES :- (i) Mode of measurement shall be actual area treated (floor and adjoining walls). |
| 12 | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in roof kerbs, benching etc including weathering, slightly rounded or chamfered angle and throughting complete all as specified and as directed. |
| 13 | M&L for providing RCC nominal mix (1:2:4) type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 14 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 15 | M& L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 16 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premices complete all as specified and directed. |
| 17 | Roughening surfaces of old concrete /terrazzo floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed. |
| 18 | M&L for joint free anti skid coloured ceramic tiles, 7 to 8mm thick (squre or rectangular) area of each tile exceeding 0.11sqm but n.exc. 0.18sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces, laid over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed. |
| 19 | Description all as per item 18.00 above but as in skirtings laid over and including 10mm thick plaster in CM (1:4) complete all as specified and as directed. |
| 20 | M&L for granite (18-20mm thick) work as in counter for cooking & W.H.B platform including rounding and grinding of edges and like laid on cement mortar (1:4) including pointing in white cement (1:2) using marble dust and admixture of pigment to match with shade of granite including cutting for hole, rounding of edges and mirror polishing complete all as specified and as directed. Note:-(a) Rates also includes in this item for necessary raking, circular cutting or notching and waste on Granite.(b) This item shall be used for W.H.B Counter top /cooking platfom/ Counter top /skirtings/ vertical surface/steps, jambs, pillars, window-cills etc. |
| 21 | M&L for joint free non skid coloured ceramic tiles, 7 to 8mm thick (squre or rectangular) area of each tile n.exc. 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces, laid over & including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 22 | M&L for joint free coloured glazed ceramic tiles in vertical surfaces of size (300x200)mm x7mm thick/ (450x300)mm x7mm thick, set and jointed in cement slurry and pointed in white or coloured cement to match laid over & including 15mm thick cement rendering in cement mortar (1:4) complete all as specified and as directed. |
| 23 | M&L for 40 mm thick cement concrete type B0, 1:2:4 (using 12.5 mm graded aggregate) as in flooring, to be finished even and fair complete including necessary use and waste of form work complete all as specified and as directed. |
| 24 | M&L for 75 mm thick cement concrete (1:3:6) type C2, (using 40 mm graded stone aggregate) as in hard standing/pavings/plinth protections, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-Charge. |
| 25 | M & L for machine pressed, glossy finished 25 mm thick coloured cement concrete chequered tiles of size 300mm x 300 mm of pattern as approved, set, jointed and pointed in neat cement slurry mixed with pigment in floors laid over and including 15mm thick screed bed with cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge. |
| 26 | M&L for machine pressed precast concrete interlocking paver block any shape and size, with grey cement and pigment to match, confirming to IS 15658-2006 of 60mm thick M-35 grade with and including laid over 50 mm thick sand cushioning complete all as specified and as directed. |
| 27 | M&L for Durastone vitrified tiles coloured, light shade 10 mm thick, area of each tile exc 0.06 but not exc 0.36 Sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces, laid over & including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 28 | Demolition of brick work built in cement mortar, including all quoins, arches, pillars etc of any description including removing debrish from site complete all as specified and as directed. |
| 29 | M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 30 | M&L for brick work with sub class ‘B’ bricks, straight or curved on plan of any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and as directed. |
| 31 | Description all as per ser item No 29.00 above but except bricks complete all as specified and as directed. Note:- Old bricks shall be retrieved from Ser Item No. 28.00 here in above. Please Enable Macros to View BoQ information |
| 32 | Description all as per ser item No 29.00 above but except bricks complete all as specified and as directed. Note:- Old bricks shall be retrieved from Ser Item No. 28.00 here in above. Please Enable Macros to View BoQ information |