|
| 1 | Supplying & Fixing of 415 V, 8 - ways Sub-Main Distribution Board (SMDB) (Make - Lauritz Knudsen, Cat No. DA20D1084CZZO, Type - TN250D, Rating up to 250 A) with IP-43 protection on angle iron frame on wall with S&F following accessories:- a) TN250D 3 Pole MCCB - 250 A (Make - LK, Cat No. CM9860800ΡΟ) as incomer - 1 no., b) TN250D 3 Pole MCCB-100A (Make - LK, Cat No. - CM9789300K20G) as outgoing devices - 8 nos., c) Metering Extension Box - 1 no, Bottom Cable end Box - 1 no. and both Side Cabling Boxes, corner boxes - 4 nos d) Digital Meter for display of Current, Volt, KWH, PF, MD with date & time stamp etc., e) On, off & trip indicating lamp for incoming, f) CL:0.5, 250/5 A, 5 VA, tape wound CT (Make- Kappa/AE/LK) for all three phases, g) Selectror Switches with any other accessories as required. |
| 2 | S & F of 415 V, up to 160 A capacity MCCB incomer, 63 A SP/TP MCB outgoing, double door and following ways VTPN MCB DB (Make - Legrand / Siemens / ABB Itus) with IP-43 protection on angle iron frame on wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment - [15/D-11]4 Ways |
| 3 | 6 Ways |
| 4 | 8 Ways |
| 5 | S & F of double door sheet steel (16 SWG), powder-coated cable end box for 6/8 way VTPN MCB DB enclosure with IP-43 protection, on an angle iron frame on the wall & mending the damages to the original finish with nuts, bolts, etc., including provision for earthing attachment. [16/D-12] |
| 6 | S & F of 415 V, FP MCCB (Make - Legrand/Siemens/ABB) of breaking capacity 36 kA with adjustable thermal and fixed magnetic setting in VTPN DB and necessary connection. [10/D-8]100 A |
| 7 | 125 A |
| 8 | S & F of 415 V, 32 A per way double door 4 Way HTPN MCB DB (Make - Legrand / Siemens / ABB Itus) with IP-43 protection, concealed in the wall after cutting the wall & mending the damages to the original finish, including Interconnection with a suitable size of copper wire and neutral link & provision for earthing attachment. [14/D-10] |
| 9 | S & F of 415 V, 63 A, FP, MCB type Isolator (Make - Legrand/Siemens/ABB) on DIN rail of HTPN DB and necessary connection. [6/D-5] |
| 10 | S & F of 240/415 V, following SP/TP MCB of breaking capacity 10 kA & 'C'- characteristics (Make - Legrand / Siemens / ABB) on din rail of HTPNVTPN DBs and necessary connection. [7/D-6]63 A TP MCB |
| 11 | 32 A TP MCB |
| 12 | 6 to 32 A SP MCB |
| 13 | S & F of 415 V, 125 A TPN on load front operated Changeover switch (Make - Legrand / Siemens / ABB / Schneider) with sheet steel enclosure on angle iron frame on wall with nuts, bolts, etc. [3(a)/D-2] |
| 14 | S & F of 240 V, 25 A 3-pin Modular type plug socket (Make - ABB IVIE / Legrand - Myrious / Schneider - Opale/Unica Pure), 2 Module GI Modular type switchboard flush in the wall after cutting the wall, top cover plate and making necessary connections with PVC Cu wire and earth continuity wire, etc. (For AC Machine). [5(a) / E-17] |
| 15 | S & F of 240 V, 25 A, 3 pins Modular type plug top with an indicator (Make - ABB IVIE / Legrand Myrious / Schneider - Opale/Unica Pure) & necy. Connections. [5(b)/E-17]. |
| 16 | S & F of 240 V, 25 A, Modular type starter (Make - ABB IVIE / Legrand Myrious / Schneider - Opale/Unica Pure) with 25 A Modular switch type SP MCB (C-Curve) and 4 Module GI Modular type switchboard with 4 Module top cover plate flush in wall incl. S&F switchboard and cover plate and making necy. connections with PVC Cu wire and earth continuity wire, etc. [17/E-19]. |
| 17 | S & F of PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. [7/E-16]20 mm size |
| 18 | 25 mm size |
| 19 | Making 25 mm dia holes on a 125 mm depth RCC ceiling. [9(a)/E-3] |
| 20 | S & F of sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works.100 mm x 100 mm x 65 mm [11(a)/E-4] |
| 21 | 150 mm x 100 mm x 65 mm [11(b)/E-4] |
| 22 | 175 mm x 100 mm x 65 mm [11(c)/E-4] |
| 23 | Supplying and Drawing of 1.1 KV Gr., 2 x 4 sq. mm + 1 x 2.5 sq. mm, single core stranded 'FR' PVC insulated & unsheathed stranded copper wire (Make - Finolex/ RR Kabel/ Havells) in the pre-laid polythene pipe. [1(v)/E-9] |
| 24 | S & F of bakelite top cover on existing inspection box by Brass screws- 100 mm x 100 mm x 65 mm [13(a)/E-5] |
| 25 | 150 mm x 100 mm x 65 mm [13(b)/E-5] |
| 26 | 175 mm x 100 mm x 65 mm [13(c)/E-5] |
| 27 | Finishing the ends of 2 x 4 sq. mm + 1 x 2.5 sq. mm PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [9/F-5] |
| 28 | Supplying and delivering the Armoured Cables with XLPE/PVC insulated, designed for 1.1 kV, Stranded Aluminium Conductor, high tensile galvanised steel wire/strip armour for mechanical protection and PVC/FR PVC outer sheathing power cable (Make - Havells / Universal / RR Kabel) of the following sizes as per IS 7098 Part - 1/2011 with up-to-date amendments ----4 core 25 sq. mm cable |
| 29 | 4 core 70 sq. mm cable |
| 30 | Supplying & fixing of the following sizes medium gauge GI pipe (ISI medium - Zindal / Bansol / Tata) protection with necessary fittings and jointing materials as required. [11(d)/F-6]40 mm dia GI Pipe [11(c)/F-6] |
| 31 | 50 mm dia GI Pipe [11(d)/F-6] |
| 32 | S & F of perforated 300 mm x 50 mm x 1.25 mm (18 SWG) GI cable tray with perforation not more than 17.5% suspended from the ceiling incl. S&F GI connector, 6 mm dia MS suspender, bolts & nuts, steel fastener, etc. as required incl. Al painting (two coats) of MS support with 25 mm x 25 mm x 3 mm angle iron support. [34(a)(ii)/D-14] |
| 33 | Laying of the following sizes Ar. Al, the cable on the wall/surface incl. S & F MS saddles/clamps with earthing attachment in 2 x 10 SWG GI (Hot-Dip) wire, making holes etc. as necessary mending good damages and painting - 4 core 25 sq. mm cable [2(b)/F-1] |
| 34 | 4 core 70 sq. mm cable [2(d)/F-1] |
| 35 | Laying of the following cables through existing RCC / Hume / GI Pipe / open masonry trench. 4 core 25 sq. mm cable [3(a)/F-2 ] |
| 36 | 4 core 70 sq. mm cable [3(b)/F-2 ] |
| 37 | Laying of 4-core 25 sq. mm cable on the existing Cable Tray and binding with suitable size GI wire. [6(i)/F-3] |
| 38 | Laying of 4 core 70 sq. mm cable on the existing Cable Tray and binding with suitable size GI wire. [6(ii)/F-3] |
| 39 | S & F of compression type gland complate with brass gland, brass ring & rubber ring for dust & moisture proof entry of following XLPE/PVÇ Armoured cables as helow : 4 core 25 sq. mm cable [7(c)/F-4] |
| 40 | 4 core 70 sq. mm cable [7(c)/F-4] |
| 41 | Finishing the end of following XLPE/PVC armoured cables by cimping method incl. supplying and fixing solder less socket (Dowels make), tapes, anticorrosive paste & jointing materials. [8(b)/F-5]4 core 25 sq. mm cable |
| 42 | 4 core 70 sq. mm cable |
| 43 | Excavation of soil for the installation of Earth Electrode and filling & ramming for soft soil. [1(a)/G-1] |
| 44 | Earthing with 50 mm dia GI pipe (Tata Medium), 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. [2(a)/G-1] |
| 45 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2)] |
| 46 | Extra for treatment of soil by using salt & charcoal or coke for pipe electrode.[3(b)/G-2]. |
| 47 | S & F of earth bus bar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the bus bar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [4(b)/G-2] |
| 48 | Connecting the equipment body to the earth bus bar, including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipment incl. drilling holes, with bolts, nuts, washers, etc. [5(d)/G-3] |
| 49 | Charge for Dismantling the existing Industrial type Old L.T Electrical Distribution panel. |
| 50 | Connecting the equipment to earth bus bar including S & F 4 SWG GI (Hot Dip) wire on wall/floor with staples buried inside wall/floor as required and making connection to equipment with bolts, nuts, washers, cable lugs etc. as required and mending good damages. [5(a)(i)/G-2)] Please Enable Macros to View BoQ information |