| 1 | Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed |
| 2 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep in any type of soil and getting out complete all as specified and directed |
| 3 | Removing excavated material (any type of soil) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed |
| 4 | Returning filling in hard/dense soil including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed |
| 5 | M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed |
| 6 | Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed. |
| 7 | M& L for precast cement concrete block masonry with solid blocks using PCC 1:3:6, type C1(using 20mm graded stoneaggregate), exc. 10cm in width, set in CM 1:6 all as specified and as directed. |
| 8 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 9 | M&L for complete removal of existing treatment on plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed |
| 10 | M&L for 10mm thick plaster in CM (1:6) on fair faces of concrete/PCC block surfaces of walls finished even and smooth (without using extra cement) all as specified and as directed. |
| 11 | M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed. |
| 12 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed. |
| 13 | M&L for hardcore of broken stone or boulders of gauge n. exc 63 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rammed to a true surface all as specified and as directed. |
| 14 | M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed |
| 15 | M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed |
| 16 | M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick on vertical surfaces as in skirtings, dados and risers of steps with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 10mm thick screed bed in CM 1:3 complete all as specified and directed |
| 17 | M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping, edging including necessary form work complete all as specified and as directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed |
| 19 | S&F for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc of required size on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. |
| 20 | Dismantling floor, hearth or wall tiling including CM bedding, removing rubbish off the premises complete all as specified and as directed. |
| 21 | M&L for light shade vitrified ceramic tiles minimum 8mm thick (square/ rectangular) polished area of each tiles n. exc 0.36 Sqm (600x600mm) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed |
| 22 | M&L for light shade vitrified ceramic tiles minimum 8mm thick (square/ rectangular) polished area of each tiles n. exc 0.36 Sqm (600x600mm) in vertical surfaces such as skirting, dados and riser etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed of cement mortar 1:3 complete all as specified and directed |
| 23 | M & L PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) 25mm thick as in levelling course, sub-floors and paving etc complete all as specified and as directed. |
| 24 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed of CM (1:4) bedding complete all as specified and as directed. |
| 25 | M&L glazed ceramic coloured tiles as in vertical surfaces of size 300 x 450 x 7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match incl 10 mm thick backing coat in CM (1:3) as specified and as directed. |
| 26 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.11 Sqm but n. exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed |
| 27 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.11 Sqm but n. exc 0.18 Sqm as in vertical surface such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 to recieve tiles complete all as specified and directed |
| 28 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons, riser of steps, skirting, dado etc laid in any mortar complete all as specified and as directed. |
| 29 | M&L for 16-18mm thick granite of approved quality machine cut polished, bedded and jonted with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone as in cooking platform, counter of WHB and like over and including 15mm thick screed bed in CM 1:4 including grinding/chamfering and polishing the edges complete all as specified and as directed by Engr-in-Charge |
| 30 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed |
| 31 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof coverings complete all as specified and directed |
| 32 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed |
| 33 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, fixed with self tapping screws all as specified and directed |
| 34 | M&L aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering all as specified and directed |
| 35 | S&F framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, and similar works like cooler stand conforming to Fe-290, Gde -E-165 complete all as specified and directed |
| 36 | S&F mild steel roof trusses (framed), trrussed, purlins, crane gantries, rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed |
| 37 | M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 38 | M&L for applying two coat of synthetic enamel paint including preparation of old steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 39 | Dismantling of ceiling boarding including grid of any description fixed in any position with nails complete all as specified and directed |
| 40 | S&F for anodized aluminum snap grid frame work for false ceiling incl hangers 3mm dia, GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60 mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed |
| 41 | M&L for 4mm thick non asbestos fiber cement building design board of size 605x605mm fixed or laid to aluminum grid work with screws and including preparation of surface with two coat of oil bound distemper over a coat of chalk whiting primer complete all as specified and as directed |
| 42 | M&L for seamless designed gypsum board false ceiling 12mm thick including for any sunk or raised moulding with 25mm long self drilling/ tapping screws having philips head with joining compound and 48mm wide fiber tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flange of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm suspended from soffit at approx 900mm c/c with GI cleats and steel expansion fasteners with and incl ceiling section ( not exc 1.2m length) of 0.55mm thick having kurled web of 50mm an flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting across the intermediate channel at 457mm c/c incl hangers 6mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete and finally applying two coats of oil bound distember with roller finish over a coat of chalk whiting primer cmplete all as specified and directed |
| 43 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer over a coat of 1mm thick wall care putty to make the surface smooth complete all as specified and directed |
| 44 | M&L for applying two coats of oil bound distemper over a coat of primer over a coat of 1mm thick wall care putty to make the surface smooth after complete removal of existing treatment complete all as specified and directed |
| 45 | M&L for 15mm thick plaster in CM 1:4 on fair face of brick walls or concrete surface including mixing of liquid water proofing compound @ 200ml per 50 Kg cement bag, finished the surface fair and even without using extra cement complete all as specified and as directed. (Note: Water proofing compound shall be measured and paid separately) |
| 46 | Supply only liquid water proofing compound |
| 47 | Taking down chowkhats or frames area n. exc 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed |
| 48 | Taking down Chowkats exc 1.5 Sqm but n. exc 4 Sqm each with shutters (Without taking off shutters from the frame) complete all as specified and directed |
| 49 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with fullbody threaded star headed SS screws having minimum frame density of750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressivestrength of 58 N/mm2modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid forseparately). |
| 50 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction . (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 51 | S&F 100mm size stainless steel butt hinges medium weight complete all as specified and as directed. |
| 52 | S&F 150mm aluminium, anodised, barrel tower bolts of extruded section all as specified and as directed. |
| 53 | S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised all as specified and as directed. |
| 54 | S&F 300 mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet sliding bolts of extruded sections and fixing bolts and sliding bolts of extruded section all as specified and as directed. |
| 55 | S&F door closer hydraulically regulated aluminium (die cast) body, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and as directed. |
| 56 | M&L for 18mm thick HDF boarding (fire & water proof) as in cup boards exterior grade with one side white lamination and other side coloured prelaminated, size of the cabinet as per requirement of the site complete all as specified and as directed . Make : Archidply industries Ltd/Vidya Ply&board Pvt Ltd/Adarsh sales Pvt Ltd (Note : (i) Cutting edges of cupboard shutter/shelves to be finished with adhesive edge binding tape all as directed) |
| 57 | S&F stainless steel auto closing hinges 35mm of 0 crank( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete all as specified. Make : Hettich/Harrison/Dorsel |
| 58 | S&F stainless steel non megnetic bow handle \\"D\\" type anodized 150mm long complete all as specified. Make : Hettich/Harrison/Dorsel |
| 59 | S&F stainless steel non megnetic barrel tower bolt 100mm long of extruded section complete all as specified. Make : Hettich/Harrison/Dorsel |
| 60 | Dismantling PVC water tanks exc 500 Ltr but n. exc 1000 Ltr capacity and removing to store complete all as specified |
| 61 | S&F double layer rotational moulded PVC water storage tank cylinderical, vertical with closed top hoisted and fixed in position tank capacity 1000 Ltr with and including PTMT float valve 20mm dia and making connection for inlet and outlet complete all as specified and directed |
| 62 | Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed |
| 63 | S&F in 20mm outer dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including suitable reducer for 15mm dia taps fitting as required complete all as specified and as directed. |
| 64 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed |
| 65 | S&F 20mm bore gun matel globe or gate valve with iron wheel, screwed both ends for iron pipes complete all as specified and as directed. |
| 66 | Dismantling of 110mm dia cast iron/PVC pipes incl bends/branch pieces jointed in cement mortar and taking out if reqd. |
| 67 | S&F PVC (SWR) pipe 110mm bore, single socketed, in any length including bends, socket etc with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed |
| 68 | S&F PVC (SWR) pipe 110mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive laid in trenches or in floors complete all as specified and directed |
| 69 | S&F PVC (SWR) 110mm dia bend of any radius and jointed with approved adhesive complete all as specified and directed |
| 70 | S&F PVC (SWR) 110mm dia junction single (single T) equal or unequal reducer 'T' 110mm to 75mm dia and jointed with approved adhesive complete all as specified and directed |
| 71 | Dismantling of 75mm dia cast iron/PVC pipes incl bends/branch pieces jointed in cement mortar and taking out if reqd. |
| 72 | S&F PVC (SWR) pipe 75mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive fixed to walls complete all as specified and directed |
| 73 | S&F PVC (SWR) bend 75mm dia, any radius as required and jointed with approved adhesive complete all as specified and directed |
| 74 | S&F 75mm outlet dia PVC (SWR) floor trap with grating including jointing with solvent cement to waste pipe complete all as directed |
| 75 | M&L for anodised aluminium frame for doors, windows, ventilators, partition with one or more rebates including joining cleat for fixing etc complete as specified |
| 76 | S&F Anodised aluminium grill of approved pattern cut to required size/shape and fixed with position with aluminium bedding & frame with & including F sections, fixed to aluminium windows/ventilators complete all as specified and directed. |
| 77 | S&F 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 78 | S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium wire staples all as specified and directed |
| 79 | S&F sheet glass 4 mm thick ordinary quality and glazing with aluminium glazing clip in aluminium window/ventilator shutter exc 0.5 Sqm in each pane complete all as specified and directed |
| 80 | S&F sheet glass 5.5 mm thick ordinary quality and glazing with aluminium glazing clip in aluminium window/ventilator shutter not exc 0.5 Sqm in each pane all as specified and as directed. |
| 81 | Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed. |
| 82 | Taking down existing unserviceable distribution boards of any description alongwith MCBs/MCCBs refixing the same after repairs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 83 | Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 84 | M & L point wiring for One light/fan point controlled by one switch 5 Amps one way complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified:-Make of wire : V-Marc/ Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces. |
| 85 | All as per Srl item No 84 above, but, point wiring for 5 pin switch socket outlet , 6 Amps on independent board complete all as specified and as directed. |
| 86 | All as per Srl item No 84 above, but, point wiring for 5 pin switch socket outlet , 6 Amps on same board complete all as specified and as directed. |
| 87 | All as per Srl item No 84 above, but,One bell point controlled by one bell push switch 5 Amps one way complete all as specified and as directed. |
| 88 | All as per item No.84.0 above but point wiring with two single core 4.0 sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 6 pin 16 Amps socket out let on independent board complete all as specified and as directed. |
| 89 | S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed. |
| 90 | S & F for switch modular type, 15 Amps 1 module, 230 volts AC circuit complete all as specified and directed. |
| 91 | S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed. |
| 92 | S & F Socket outlet 2 in 1 modular type, 3 pin, 5 and 15, flush type, universal all as directed. |
| 93 | S & F bell push switch modular type, single pole, 5 Amps, 240 volts AC all as directed. |
| 94 | S & F for ceiling rose, 3 phase, PVC polycarbonate, isolated body complete all as specified and directed. |
| 95 | S & F Electric Bell, Ding dong type working on 230 volts AC supply all as directed. |
| 96 | S & F stepped type electronic fan regulator modular type complete all as specified and as directed. |
| 97 | Taking down carefully ceiling fan of any make, size from its location, dismantling complete, examine complete parts thoroughly, oiling, greasing all parts and complete overhauling of fan including replacement of small parts such as split pin, nut bolt, screws and assembling back the fan, make fully functional, re-fixing the fan to its position including replacing and providing of twin core copper wire 23/0.0076 from fan to ceiling rose and painting the fan with same colour of fan complete all as directed. |
| 98 | Supply and fixing new GI brackets of GI pipe light grade of size 32 mm dia including nuts, bolts and washers for building secufity light all as specified and directed |
| 99 | S & F in repairs 30 watts LED building security light fittings , pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 with pranuts including necessary fixing arrangements as per site requirements class all as specified and directed . Make : Luker Cart Part No: LSTE030S or equivalent in Philips /Havells/ CG |
| 100 | S & F in repairs and testing LED Tube light fittings aluminium tubes 22 watts 4 feet including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Luker Cat Part No : LT522 or equivalent in CG/Philips Havells |
| 101 | S & F in repairs and testing Tube light fittings LED 10 watts 2 feet including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Luker Cat Part No : LT510P or equivalent in CG/ Philips/ Havells |
| 102 | S & F Sub main wiring with PVC insulated cable 2 single core 6 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid PVC conduit concealed/surface in wall (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 6.0 sq mm for earth continuity all as specified and as directed. |
| 103 | S & F Sub main wiring with PVC insulated cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid PVC conduit concealed/surafce in wall (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4.0 sq mm for earth continuity all as specified and as directed. |
| 104 | Supplying & fixing MCB SPN 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed. |
| 105 | Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed. |
| 106 | M & L Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement all as specified and as directed. |
| 107 | M&L for Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.00 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion including taking out old earthing. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 15 mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. Please Enable Macros to View BoQ information |