| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
| 8 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 9 | Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 10 | Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 11 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 12 | Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 13 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more |
| 14 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 16 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required completeIn cement mortar 1:4 ( 1 cement : 4 fine sand ) |
| 17 | Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course of half brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost ofall materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 18 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 19 | Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required |
| 20 | Providing & fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade Ac 10 as per IS :1868)transparent or dyed to required colour shade with nuts and screws etc. complete |
| 21 | 300 x 16 mm |
| 22 | Providing & fixing aluminium tower bolt ISI marked anodised (anodic coating not less than grade Ac 10 as per IS 1868) transparent or dyed to required colour shade with nuts and screws etc. complete |
| 23 | 250 x 10 mm |
| 24 | Providing & fixing aluminium handles ISI marked anodised (anodic coating not less than grade Ac 10 as perIS 1868) transparent or dyed toreqd colour shade withnuts and screws etc. complete |
| 25 | 125 mm |
| 26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 27 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge.600 mm X 300 mm in all shades and design |
| 28 | Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 -2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge.Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles300 mm x 300 mm in all shades and designs |
| 29 | Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge.0.45mm thickness |
| 30 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc.complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 31 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 32 | 6 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 33 | Neat cement punning |
| 34 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including water thinnable priming coat with cement primer |
| 35 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture |
| 37 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer]With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 38 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction ofEngineer in Charge.Internal work - Exposed on wall25 mm nominal outer dia .Pipes. |
| 39 | Providing and fixing brass stop cock of approved qualityi) 15 mm nominal bore |
| 40 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete |
| 41 | 25 mm nominal bore |
| 42 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore. |
| 43 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 44 | Dismantling GS sheet roofing including ridges, hips,valleys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all liftsand upto a lead of 50 m etc.complete as per direction of the Engineer- in-charge. |
| 45 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessaryfittings, including applying a priming coat of approved steel primer etc. complete as required:Using M.S. angels 40x40x6 mm for diagonal braces. |
| 46 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixingnecessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:80xl.25mm M.S. laths with 1.25 mm thick top cover. |
| 47 | Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying apriming coat of approved steel primer complete as required:- M.S. tube |
| 48 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 49 | Dismantling rolling shutters with all accessories and stacking properly and refitting the same after oiling and greasing the same with necessary cement concrete for fitting fixing of hold fasts etc. for all lifts and upto a lead of 50 m as required complete as per direction of the Engineer in charge. Please Enable Macros to View BoQ information |