| 1 | Earth work in filling or in embankement in ordinary soil upto 8.00km.[As per S.i. No-251+231(a)] |
| 2 | Boring and costing 30 cm dia piles of double under reamed of 75 cm dia bulb and 3.6 m deep below ground level consting of 12 mm dianbars and 6 mm dia 25 cm c/c rings filled with cc in 1:2:4 in 2 cm guage stone grit, coarse sand cement including supply of all materials labour T&P etc. required of the proper completion of the work.(new item 1 chapter -4) |
| 3 | P/L of C.C in 1:6:12 (1 cement :6 f.sand:12 stone ballast) including supply of all materials T&P etc labour required for the proper completion of the work. (As per S.i. No-273) |
| 4 | P/L of C.C in 1:11/2 :3 (1 -cement :11/2 c.sand. 3- 20 mm gauge stone grit ) including supply of all materials T&P etc labour required for the proper completion of the work.(As per S.i. No-279 b ) |
| 5 | RCC work width 1:1.5:3 cement, coares sand and 20mm guage stone grit.(As per S.I. No-288) |
| 6 | Mild steel In R.C.C. work. |
| 7 | Class -150 brick work in 1:4 cement and coares sand mortar.(As per S.I. No-305) |
| 8 | 12mm thick plaster on brick work in 1:4 cement and coare sand mortar.(As per S.i. No-583) |
| 9 | Supply & fixing of rolling shutter of approved make of 80x1.25 mm (3\\"x3,1/2\\") cold rolled M.S. laths inter locked throughout their entire length and jointed together at the end locks and mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and spring. (As per S.i. No-520) |
| 10 | providing & fixing 27.5 mm long wire springs grade 2 for rolling shutters.( As per S.i. No. 521) |
| 11 | providing & fixing top cover for rolling shutters.( As per S.i. No. 522) |
| 12 | providing & fixing ball bearing for rolling shutters.( As per S.i. No. 523) |
| 13 | Birla Putty all complete (As per S.I. No-662-13.8) |
| 14 | Painting two coat with primer.( As per S.I. No-1.47.1) |
| 15 | Painting & varnishing of gate.( As per S.I. N0-641) |
| 16 | P/L of 8 to 10 mm thick Vitrified tiles in flooring or skirting or dado laid with ratio1:3 cement & approved coarse sand.(As per S.I. No- add new item Chapter 14) |
| 17 | Installation, testing and commissioning of ceiling fan, including.wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (DSR- 1.45) |
| 18 | S/F of RCC bench.(As Market rate) |
| 19 | Sign Board Please Enable Macros to View BoQ information |