| 1 | Dismantling of wall and ceiling boards( fibre pulp insulation etc) any thickness including cover fillets,complete all as specified and as directed. |
| 2 | S& F Non asbestos fibre cement buildingboards fixed orlaid/ inserted to timber/GI/Aluminium framework with screws for fixing 600mm x 600mm grid (frame work for celling shall be measured and paid separately) 06mm thick in celling fixed with screw as per manufactures's instruction and acoustic purpose 60x60 cm in size.fixed with snap grid by screw etc completed all as specified and as directed.NOTE: (The rate inclusive of scaffolding and necessary arrangements(ht of building shall be up to 10m complete all as specified and as directed. |
| 3 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified . NOTE: (The rate inclusive of scaffolding and necessary arrangements),complete all as specified and as directed. |
| 4 | S&F of prepainted anodised Aluminium snap grid frame work for flase celling complete all as specified and as directed. |
| 5 | M&L for preparing of surfaces plastered or unplastered ceiling surfaces and applying two coats of white wash over a coat of chalk whiting primer complete all as specified and as directed. |
| 6 | Dismantling Plain or corrugated steel sheeting of any gauge & any thickness, including Nainital or similar pattern of roof coverings including ridge complete all as specified and as directed. |
| 7 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 8 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in ridge/flusing/eves board of width or girth not less than 600mm complete all as specified and as directed. |
| 9 | S&F 1 mm thick Plain, galvanised, mild steel sheeting, in evege boarding, ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 10 | M&L Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc.for post (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming Fe-410W(GdeE-250) quality B includng welding or riveting etc complete all as specified and as directed . |
| 11 | Taking up or down water tank of capacity 500lt and removing to store,complete all as specified and as directed. |
| 12 | Taking up or down water tank of capacity 1000lt and removing to store,complete all as specified and as directed. |
| 13 | S&F Rotational moulded polyethylene water storage tank including, plastic lid cover, triple layered, white coloured, (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 ltrs including making connections, 20 mm dia ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic ballscrewed for iron pipe anf fixed (min wt 210 gram) complete all as specified in SSR Part I and as directed . |
| 14 | S&F rotational moulded polyethylene water storage tank triple layered, white coloured ( cylindrical vertical with closed top) hoisted and fixed in position of 1000 liters capacity confiring to IS specification, complete all as specified and as directed. |
| 15 | M&L Preparation old steel surfaces of any description not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paint etc complete all as specified and directed. |
| 16 | M&L Preparation of old wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and directed. |
| 17 | M&L Preparation of old plastered or unplastered surfaces of walls including cornices, pillasters by brooming down or steel wire smoke, root, moulds, moss and efforescent salts, and trading oil and greasy spot by using suitable chemical & removing nails, making good holes with birla white putty cracks and brooming to remove all dirt etc and applying one coat of Cement based paint on old prepared surfaces of walls complete all as specified and directed . |
| 18 | M&L for Preparation of old plastered or unplastered surfaces of walls including cornices, pillasters by brooming down or steel wire smoke, root, moulds, moss and efforescent salts, and trading oil and greasy spot by using suitable chemical & removing nails,filling cracks and making good holes with birla white putty, and brooming to remove all dirt etc and applying one coat of Oil bound distemper on old prepared surfaces of walls complete all as specified and directed. |
| 19 | Demolition of cement concrete (unreinforced) in ground floor and pavings, n exc 15 cm thickness (below or ground level) complete all as specified and as directed. |
| 20 | M & L for 40mm thick cement concrete (1:2:4) type B-1 ( using 20mm graded stone agg.) as in floor finishing/Plinth protection surface even and smooth with using extra cement all as specified and directed . |
| 21 | Demolition of brick/stone/boulder masonry, built in cement mortar including all quoins,arches,pillars,etc,but exceeding ashlar facings,dressed stone work and precast concrete complete all as specified and directed. |
| 22 | M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 23 | Taking down cement or cement plaster of any description on brick or stone walls or from concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc and removing unserviceable material outside cantt area complete all as specified and as directed. |
| 24 | M &L for Rendering 15 mm thick in CM 1:6 on fare faces of brick surface finished even and smooth without using extra cement etc all as specified (icluding necessay scafolding lifting arrangement) complete all as specified and as directed. |
| 25 | M&L for preparation of newely plastered wall surfaces and applying two coats of Oil bound distemper over a coat of alkali resistant primer over 1mm wall care putty complete all as specified and as directed. |
| 26 | Taking down chowkats or frames with shutters n.exc 1.50Sqm (without taking off shutters from the frames),complete all as specified and as directed. |
| 27 | All as per serial item No.26 above here in before but exc 1.50 Sqm and n.exc 4 Sqm each complete all as specified and as directed. |
| 28 | S&F Powder coated (Minimum thickness of powder coating 50micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed . |
| 29 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge etc complete all as specified and directed. |
| 30 | M&L for double action floor spring hydraulically regulated made up of min 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made up of brass, other parts made of mild steel heavy duty and fixed,complete all as specified and as directed. |
| 31 | S&F Door closer hydraulically regulated Aluminium (die cast body), designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed,complete all as specified and as directed. |
| 32 | S&F 4.8 mm thick plain glass of selected quality and securing in metal / aluminium frame, complete all as specified and as directed. |
| 33 | S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed . Please Enable Macros to View BoQ information |