| 1 | Taking down carefully copper / aluminum point wiring of lights, fans, bell, sockets and power point complete all as specified and as directed.Note: Taking down of fittings and fixtures such as switches, sockets, ceiling rose, flush boxes etc. shall be measured and paid separately |
| 2 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC FRLS conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) incl cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing / plastering, applying wall putty incl 02 coat of distempering in disturbed surface with existing colour all as specified and directed complete all as specified and directed at site. |
| 3 | Description all as per ser item No. 2.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch. |
| 4 | Description all as per ser item No. 2.00 abovebut for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch. |
| 5 | Description all as per ser item No. 2.00 above but for one light point controlled by one, 2 way 5/6 Amps switch. |
| 6 | M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC FRLS conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour)with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, complete all as specified and directed. |
| 7 | S&F in repairs modular metal flush box 1 and 2 module complete incl cutting wall, fixing in replacement making good disturbed surfaces with plastering and painting to match with existing surface all as specified and as directed. |
| 8 | Description all as per ser item No. 7.00 above but of size 3 module Complete all as specified and directed. |
| 9 | Description all as per ser item No. 7.00 above but of size 4 module Complete all as specified and directed. |
| 10 | Description all as per ser item No. 7.00 above but of size 6 module Complete all as specified and directed. |
| 11 | Description all as per ser item No. 7.00 above but of size 8 module Complete all as specified and directed. |
| 12 | Description all as per ser item No. 7.00 above but of size 12 module Complete all as specified and directed. |
| 13 | S&F in repairs modular white cover plate with frame 1 and 2 module ISI marked complete all as specified and as directed. |
| 14 | Description all as per ser item No. 13.00 above but of size 3 module Complete all as specified and directed. |
| 15 | Description all as per ser item No. 13.00 above but of size 4 module Complete all as specified and directed. |
| 16 | Description all as per ser item No. 13.00 above but of size 6 module Complete all as specified and directed. |
| 17 | Description all as per ser item No. 13.00 above but of size 8 module Complete all as specified and directed. |
| 18 | Description all as per ser item No. 13.00 above but of size 12 module Complete all as specified and directed. |
| 19 | S&F in repair modular switch 1 way 6A, 1 module, ISI marked complete all as specified and directed. |
| 20 | S&F in repairs modular switch 2 way 6A, 1 module, ISI marked complete all as specified and directed. |
| 21 | S&F in repairs modular socket outlet, 6A - 2/3 pin combined 2 module, ISI marked complete all as specified and directed. |
| 22 | S&F in repair modular switch 1 way 16A, 1 module, ISI marked complete all as specified and directed. |
| 23 | S&F in repair modular socket multipurpose 6/16A, 2 module, ISI marked complete all as specified and directed. |
| 24 | S&F in repair modular bell push one way, 5/6 Amp, 240 V, ISI marked complete all as specified and directed. |
| 25 | S&F in repair modular fan regulator switch type 01 module, ISI marked complete all as specified and directed. |
| 26 | Description all as per ser item No. 25.00 above but of size 02 module. |
| 27 | S&F in repair blank plate 01 module for switch boards, ISI marked complete all as specified and directed. |
| 28 | S&F in repair TV socket 01 module, ISI marked complete all as specified and directed. |
| 29 | S&F in repair RJ 45 with shutter 1/2 module, ISI marked complete all as specified and directed. |
| 30 | S&F in repair mechanical key tag complete 2 module, ISI marked complete all as specified and directed. |
| 31 | Note for Item No 07.00 to 30.00 : Different Model Nos of Approved make as per list of makes shall be procured as per site requirement. |
| 32 | S&F in repair switch piano flush type single pole 01 way, 5 Amps, 230 Volts, ISI marked complete all as specified and as directed. |
| 33 | S&F in repair switch bell push flush type single pole 01 way, 5 Amps, 230 Volts, ISI marked complete all as specified and as directed. |
| 34 | S&F in repair switch piano flush type single pole 02 way, 5 Amps, 230 Volts, ISI marked complete all as specified and as directed. |
| 35 | S&F in repair switch piano flush type single pole 01 way, 15 Amps, 230 Volts, ISI marked complete all as specified and as directed. |
| 36 | S&F in repair socket multipurpose 2 in 1, 3 pin, 5 Amps, 230 Volts, ISI marked complete all as specified and as directed. |
| 37 | S&F in repair socket multipurpose 2 in 1, 3 pin, 5 & 15 Amps, 230 Volts, ISI marked complete all as specified and as directed. |
| 38 | S&F in repair switch socket combination multipurpose 2 in 1, 3 pin, 5 Amps, 230 Volts, ISI marked complete all as specified and as directed. |
| 39 | S&F in repair switch socket combination multipurpose 2 in 1, 3 pin, 15 Amps, 230 Volts, ISI marked complete all as specified and as directed. |
| 40 | S&F in repair switch socket combination multipurpose 5 in 1 combined 5 & 15 Amps, 230 Volts, ISI marked with mounting boxes complete all as specified and as directed. |
| 41 | S&F in repair electronic bell ding dong AC 230 volts, ISI marked single pole complete all as specified and as directed. |
| 42 | S&F in repair stepped type electronic fan regulator, flush type single pole, with 5 steps, AC 50 Hz, 230/240 volts grade, ISI marked complete suitable for BLDC fan all as specified and directed. |
| 43 | S&F in repair pendent holder bras body with GI holding hook for wall mounted fittings AC 230 volts, 50 Hz, ISI marked complete all as specified and directed. |
| 44 | S&F in repair batten holder AC 230 volts, 50 Hz ,ISI marked complete all as specified and directed. |
| 45 | S&F in repair modular type angle holder AC 230 volts, 50 Hz, ISI marked all as specified and directed. |
| 46 | S&F in repair ceiling rose 3 terminal AC 230 volts, 50 Hz all as specified and directed. |
| 47 | S&F in repair LED lamp 11 watt pin type,ISI marked complete all as specified and directed. |
| 48 | S&F in repair LED lamp 9 watt 5 star rated, pin type, ISI marked complete all as specified and directed. |
| 49 | S&F in repair LED lamp 9 watt 5 star rated, ISI marked complete all as specified and directed. |
| 50 | S&F in repair LED lamp 9 watt 5 star rated,warm white, ISI marked complete all as specified and directed. |
| 51 | S&F in repair LED lamp 9 watt threaded type, warm white, ISI marked complete all as specified and directed. |
| 52 | S&F in repair LED lamp 18 watt, ISI marked complete all as specified and directed. |
| 53 | S&F in repairs 20 W LED batten 4 feet long, wall mounted, with integrated electronic driver, ISI marked complete all as specified and directed. |
| 54 | S&F in repairs 10 W LED batten 2 feet long, wall mounted, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver with system efficiency 110 lumen/watt, ISI marked complete all as specified and directed. |
| 55 | S&F in repairs angle holder modular type with cord grip cap, ISI marked complete all as specified and directed. |
| 56 | S&F in repairs MCCB 3 pole 100 Amps breaking capacity 25 KA, Ics = 100% Icu, ISI marked including spreader link complete all as specified and directed. |
| 57 | S&F in repairs MCCB 3 pole 160 Amps breaking capacity 25 KA, Ics = 100% Icu, ISI marked including spreader link complete all as specified and directed. |
| 58 | S&F in repairs MCB TP 32 Amps, 10 KA breaking capacity, 'C' curve, ISI marked complete all as specified and directed. |
| 59 | S&F in repairs MCB TP 40 to 63 Amps, 10 KA breaking capacity, 'C' curve, ISI marked complete all as specified and directed. |
| 60 | S&F in repairs MCB TPN 32 Amps, 10 KA breaking capacity, 'C' curve, ISI marked , complete all as specified and directed. |
| 61 | S&F in repairs MCB TPN 63 Amps, 10 KA breaking capacity, 'C' curve, ISI marked complete all as specified and directed. |
| 62 | S&F in repairs Isolator 100 Amps current rating - 4 pole, ISI marked complete all as specified and directed. |
| 63 | S&F in repairs MCB SPN 32 Amps, 10 KA breaking capacity, 'C' curve, ISI marked complete all as specified and directed. |
| 64 | S&F in repairs MCB SPN 40 to 63 Amps, 10 KA breaking capacity, 'C' curve, ISI marked complete all as specified and directed. |
| 65 | S&F in repairs MCB SP 6 to 32 Amp, 10 kA breaking capacity, 240V 'C' curve, ISI marked complete all as specified and as directed. |
| 66 | S&F in repairs PVC insulated, PVC unsheathed multi stranded heavy duty copper conductor FRLSH cable of size 1.0 sq mm, ISI marked complete all as specified and as directed. |
| 67 | Description all as per ser item No. 65.00 above but of size 1.5 sq mm Complete all as specified and directed |
| 68 | Description all as per ser item No. 65.00 above but of size 2.5 sq mm Complete all as specified and directed |
| 69 | Description all as per ser item No. 65.00 above but of size 4.0 sq mm Complete all as specified and directed |
| 70 | Description all as per ser item No. 65.00 above but of size 6.0 sq mm Complete all as specified and directed |
| 71 | Description all as per ser item No. 65.00 above but of size 10.0 sq mm Complete all as specified and directed |
| 72 | S&F in repairs PVC insulated, flexible copper cable 23/0.0052, 3 core, 230 volts , ISI marked complete all as specified and as directed. |
| 73 | S&F in repairs PVC insulated, PVC unsheathed multi stranded heavy duty copper conductor 2 core cable of size 1.5 sq mm, ISI marked complete all as specified and as directed. |
| 74 | Description all as per ser item No. 72.00 above but of size 2.5 sq mm Complete all as specified and directed |
| 75 | Description all as per ser item No. 72.00 above but of size 4.0 sq mm Complete all as specified and directed |
| 76 | S&F in repairs PVC insulated, PVC unsheathed multi stranded heavy duty copper conductor 4 core cable of size 1.5 sq mm , ISI marked complete all as specified and as directed. |
| 77 | Description all as per ser item No. 75.00 above but of size 2.5 sq mm Complete all as specified and directed |
| 78 | S&F in repairs PVC insulated, flexible copper cable 23/0.0072, Flexible wire 2 core twisted , 230 volts,ISI marked complete all as specified and as directed. |
| 79 | S&F in repairs fan capacitor of 2.5 MFD for ceiling fan single phase, 230 Volts, ISI marked complete all as specified. |
| 80 | S&F in repairs fan capacitor of 4.0 MFD for exhaust fan single phase, 230 Volts , ISI marked complete all as specified. |
| 81 | S&F in repairs modular surface mounted plastic boxes 3 module for fixing of switch socket combination 16 Amps ISI marked complete all as specified and as directed. |
| 82 | S&F in repairs modular surface mounted plastic boxes 06 module for fixing of switch socket combination 6 Amps (02 Nos) ISI marked complete all as specified and as directed. |
| 83 | S&F in repairs plug top 15 Amps, 230Volt, 50 Hz, ISI marked complete all as specified and as directed. |
| 84 | Description all as per ser item No. 82.00 above but of 5 Amps complete all as specified and directed. |
| 85 | S&F in repairs 20 Amps starter switch, 230 V, 50 Hz, ISI marked complete all as specified and as directed. |
| 86 | S&F in repairs industrial plug and socket 20 Amps, 230 volts, 50Hz, ISI marked complete all as specified and as directed. |
| 87 | S&F wall mounted fan 400 mm sweep, single phase 230 volts including flexible copper cable for electric connections, ISI marked complete all as specified and as directed. |
| 88 | S&F air freshener fan 200 mm sweep, 900 RPM, PVC body AC single phase 230 volt, ISI marked with inbuilt louver complete all as specified and directed. |
| 89 | S&F air freshener fan 250 mm sweep, 900 RPM, PVC body AC single phase 230 volt, ISI marked with inbuilt louver complete all as specified and directed. |
| 90 | S&F air freshener fan 300 mm sweep, 900 RPM, PVC body AC single phase 230 volt, ISI marked with inbuilt louver complete all as specified and directed. |
| 91 | Supply only insulation tape 10 mtr length, ISI marked complete all as specified and as directed. |
| 92 | S&F in repairs metal plug and socket DB, double pole 240 volts and including one 20 Amp MCB SPN, C-Curve, ISI marked including taking down complete all as specified and directed. |
| 93 | S&F in replacement of PVC casing n caping where ever necessary of size 20 mm size, ISI marked incl screws, wooden/plastic packing complete all as specified and as directed. |
| 94 | S&F Modular Mini MCB 32 Amps for fixing in Modular plates,ISI marked complete all as specified and as directed. |
| 95 | M&L for MCB two way center off change over switch 40 Amps, for duel electricity supply management, ISI marked complete all as specified and directed. |
| 96 | S&F in replacement aluminum lugs of size 35 sq mm complete all as specified and directed. |
| 97 | Description all as per ser item No. 95.00 above but of size 50 sq mm complete all as specified and directed. |
| 98 | Description all as per ser item No. 95.00 above but of size 70 to 120 sq mm complete all as specified and directed. |
| 99 | S&F in replacement copper lugs of size 6 sq mm complete all as specified and directed. |
| 100 | Description all as per ser item No. 98.00 above but of size 10 sq mm complete all as specified and directed. |
| 101 | S&F VTPN DB, 06 way, IP-43, IK 09, double door type with metal door, suitable for fixing upto 3 pole 160 Amp MCCBs as incomer and SP/TP MCB/Isolator as outgoing, including taking down, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed. |
| 102 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed |
| 103 | S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 104 | S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 105 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 106 | M&L for Triple pole and earth encolsure with a three pin and earth plug with socket 415 Volts, 50 Hz complete with one triple pole MCB TP 32 Amps complete all as specified and directed. |
| 107 | S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal including writting the MES Number with synthetic enamel paint complete all as specified and as directed. |
| 108 | M&L for wall fans 450 mm sweep, 230 volts, 50 Hz complete with mounting brackets all as specified and directed |
| 109 | S & F flexible pipe 25 mm in repair for naked wire all as specified and directed. |
| 110 | S & F electrical round sheet for cover of conductor opening of size 4 inch white in colour all as specified and directed. |
| 111 | S & F electrical round sheet for cover of conductor opening of size 3 inch white in colour all as specified and directed . |
| 112 | S & F electrical round sheet for cover of conductor opening of size 3 inch white in colour all as specified and directed . |
| 113 | S & F Digital type single phase meter 10 to 30A , ac, 230 v, 50 Hz all as specified and directed . |
| 114 | S & F Digital type three phase meter 10 to 30A , ac, 230 v, 50 Hz all as specified and directed . |
| 115 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 116 | S & F for sheet metal enclosure MCB DB SPN 2 way 240 volts single door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 117 | S & F for LED luminaire 600 mm x 600 mm square LED panel 35/36 watts, 220 volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling, including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed. Please Enable Macros to View BoQ information |